Office of the General Manager Pandaveswar Area , P.O. Pandaveswar, Dist.-Burdwan, West Bengal-713346
Supply and Installation of Solar Operated Submersible Pumps in Pandaveswar Area.
2024_ECL_303796_1
GM-PND/EandM/23-24/176/3832 dated 04/03/2024
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Pandaveswar Area
Please refer Tender documents.
3 documents required · 3 mandatory
₹7,500
23 Mar 2024
5 Mar 2024
16 Mar 2024
5 Mar 2024
15 Mar 2024
5 Mar 2024
5 Mar 2024 - 8 Mar 2024
Amount
Supply and Installation of Solar Operated Submersible Pumps in Pandaveswar Area. (Inclusive of CMPF and Contractor Profit)
Solar Module: Supply, transport, installation and commissioning of MNRE (Ministry of Renewable Energy,Govt. of India)/ IECapproved Solar Module of multicrystaline cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA)and high transmissivity 3.2 mm tempered glass, framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC,should be a minimum of 300 Watt peak,with adequate provision for measurement tolerances.Modules supplied with the Spy system should have certificate as per IEC61215 specification or equivalent National or International standards. Modules must qualify to IEC 61730 part I and part II for safety qualification testing and Salt Mist Corrosion Testingasper IEC61701/IS 61701 and having warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied for Monocrystalline / Monocrystalline PERC/bifacial spv modules
Module Mounting Structure ( For 2 nos. of 2HP Solar Water Pumping System): Supply , transportation & installation of G.I manual tracking structure made of MS hollow sections, pipes, plates, angles etc as per IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Module as per drawing and specification of MNRE . The steel structure is to be protected with minimum 80 micron galvanisation(hot dip). 2 sets of Model mounting structure one will be on roof top and another on ground with height of more than 20 feet.
Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking Spy Module structure as per approved drawing : For 6 module structure having maximum capacity of 2700Wp and roof top foundation for 6 module structure
Powerconditioning unit including MPPT, Data logger and IP54enclosure: Supply , transport , installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 600682-Environment Standard , safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology,to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure.Inverter should have protection against Dry run, Overcurrent, Under current, Overvoltage, Undervoltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation exceptfor dry run. Inverter should be providedwith a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc. The system should be capable to store the data at a set Interval and transfer it in a pendrive through USB port. It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRS based data transmission for 2 sets of 2 HP capacity Pump-motor set
Cable and Accessories: Supplying,fitting and fixings of UV rated Copper Cable aid inside HOPE conduit and other accessories as per MNRE standards with necessary connection with the Solar PV Module, MPPTetc. I. 4.0 Sq mm three core multi studs - 100m II. Lugs,HOPE Pipe,Flexible Pipe,Saddle,Cabletie etc III. For 2 sets of 2 HP per structure
Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWGGI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S& F 15 mm dia GI pipe protection (1 Mt. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an averagedepth of 3.65 Mts. below the ground level as below: By lSI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S &F 20' mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddlesas required and connection to equipments incl. drilling holes,with bolts, nuts, washers etc complete.
Lightning protection (Pole mounted): Lightning protection with 3" X1.5" G.I pipe of 4 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (lSI Medium) having five discharge prongs of 4 SWGGI (Hot Dip) wire at top duly soldered with 7/16 stranded GI(Hot Dip) wire and 85 mrn dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/thimbles and S & F 40 mm dia GI pipe (lSI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure).
Supply and installation of 3 phase electro motor pump set suitable for Solar operation and AC operation also covering 5 years warranty for the following conditions including loading, unloading,transportation etc. One Submersible Pump-motor set for LDTW ISI marked as per IS:8034 with dischargeof 7.5 lps- 5.83 Lps at 20 mts.- 30 mts. total head with bends,cover plate, Socket,flanged, Nipple, Rubber Insertion, Nuts & bolts and all other accessories
Supply and installation of 3 phase electro motor pump set suitable for Solar operation and AC operation also covering 5 years warranty for the following conditions including loading, unloading,transportation etc. One Submersible Pump-motor set for LDTW ISI marked as per IS:8034 with discharge of 7.5 lps- 5.83 Lps at 60 mts.- 80 mts. total head with bends,cover plate, Socket,flanged, Nipple, Rubber Insertion, Nuts & bolts and all other accessories
Testing and commissioning of scheme after completion of all work.
Supply and Laying of 2 inches Suction
Supply and Laying of 1.5 inches Delivery Pipeline
Cleaning of existing well (40 Feet Deep) and covering the same with enclosure with oxygen support
Supplying P.V.C. water storage tank of approved quality with closed top 14 with lid (Black) - Multilayer 500 ltr
Total impact of GST for the purpose of CTC
GBS NEOTECH
ENTER CONSTRUCTION
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .