Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.5 L+₹7,227 (0.54%)Rejected-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-AOC Other than lowest Bidder | |
| 3 | L3₹13.7 L+₹27,367 (2.04%)Rejected-AOC 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L3 | Rejected-AOC Other than lowest Bidder | |
| 4 | L4₹14.7 L+₹1.3 L (9.84%)Rejected-AOC | L4 | Rejected-AOC Other than lowest Bidder | |
| 5 | L5₹15.8 L+₹2.4 L (18.1%)Rejected-AOC | L5 | Rejected-AOC Other than lowest Bidder |
Tender Value
₹18.8 L
EMD Value
₹37,500
Closing Date
11 Feb 2021, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR MAINT OF LT OH/UG CIRCUIT AND SWITCH GEAR, PANEL BOARD AND MCCBS AND OTHER CONNECTED ACCESSORIES AT ZONE-I AREA AT JAIPUR MIL STN
2021_MES_413085_1
GE (S)J-67P/2020-21 8626/ /E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAIPUR
Class E Cat b (i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹37,500
Yes
19 Feb 2021
16 Jan 2021
13 Feb 2021
16 Jan 2021
11 Feb 2021
29 Jan 2021
Amount
Excavation in trenches n.exc 1.5metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point
M & L Sand cushioning to PVC under ground cable with Tibba sand and punning to provide a required cover.
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm as directed by Engineer-in-Charge.
Dismantling of existing ACSR conductor of any size from insulators fixed on cracked / broken poles as directed by Engineer-in-Charge.
M&L for aluminium conductor steel reinforced (ACSR) straining properly on insulator and binding with aluminium tap/binding with connectors, jumpers etc.of any type and sizes complete all as specified and directed by Engineer-in-charge.
Straining only of existing ACSR conductor of any size tying on existing poles properly on insulators and binding with aluminium tap/binding with connectors, jumpers etc complete all as directed by Engineer-in-Charge. (each length of conductor measured separately) Note :- Measurement and payment shall be made by measuring horizontal distance between centre of two adjacent poles and adding 3% extra for sag, joints & jumpers etc.
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles / walls under road crossing etc of following sizes including dismantling & taking down existing pipe :-
100mm bore
80mm bore
50mm bore
M&L Earthing complete with galvanized steel plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground earth pit not less than 2.25 meter deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI strip 32 mm X 6 mm protection by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to continuous earth wire on pole all as specified and testing on completion, including provision of earth wire protected by 40mm dia GI light grade protection pipe from test point to main board and 20mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as directed at site.
M&L Earthing complete with galvanized steel plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground earth pit not less than 2.25 meter deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI strip 25 mm X 4 mm protection by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to continuous earth wire on pole all as specified and testing on completion, including provision of earth wire protected by 40mm dia GI light grade protection pipe from test point to main board and 20mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as directed at site.
Trimming of tree branches upto 75 mm dia to clear the route of HT/LT over head lines upto 3m from the conductor including removing the cut branches from site and depositing at places n exc 50m all as directed by Engineer-in-Charge. (Note :- 1. One span from pole to pole of distance not exceeding 30 metres shall be considered as one unit. 2. The frequency of trimming of tree branches shall not be less than 3 months)
Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc incliuding taking down of following size :-
240 Sqmm, 3½ Core
185 Sqmm, 3½ Core
120 Sqmm, 3½ core cable
95 Sqmm, 3½ Core
70 Sqmm, 3½ Core
50 Sqmm, 3½ core cable
35 Sqmm, 3½ core cable
25 Sqmm, 3½ core cable
M & L Painting to old steel surface Steel tubular pole 9.0 mtr long with attached accessories (cross arms, clamps, GI protection pipe etc) with one coat of aluminium paint after preparation of surfaces including painting to poles with two coats black & white paints in straps alternatively all round the poles from the bottom of the pole for indication of poles. Height of the strap shall be 30cm and number of straps shall be 5 Nos complete all as specified and directed by Engineer-in-Charge.
Supply and fixing cable jointing kit termenation for 1.1 KV grade cable for straight through joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing of following size:-
25 - 35 Sqmm 3½ Core
50 - 70 Sqmm 3½ Core
95 - 120 Sqmm 3½ Core
150 - 185 Sqmm 3½ Core
Supply and fixing cable jointing kit termenation for 1.1 KV grade cable for end termination joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing of following size:-
25 - 35 Sqmm 3½ Core
50 - 70 Sqmm 3½ Core
95 - 120 Sqmm 3½ Core
150 - 185 Sqmm 3½ Core
240 - 300 Sqmm 3½ Core
M&L for find fault locaton using fault locating machine for fault finding for LT/HT cables of any type/size complete all as specified and directed by Engr-in charge. Any No of fuault in single cable shall be considered to be one unit for payment purposes.
Disconnecting & taking out the existing Unserviceable MCCB 415V, 50 Hz, 3 Phase from panel S&F MCCBs including extension terminals and connecting using suitable fasteners, modification/fabrication if any complete all as required at site, as specified and directed.
S&F new MCCB 63 amp, 25 KA breaking cap of suitable frame size, 4 Pole,
-ditto- but 100 amp, 25 KA
-ditto- but 125 amp, 25 KA
-ditto- but 160 amp, 25 KA
-ditto- but 200 amp, 35/36 KA
-ditto- but 250 amp, 35/36 KA
-ditto- but 320 amp, 35/36 KA
-ditto- but 400 amp, 35/36 KA
S&F aluminium conductor cable of size 10 sq. mm, 2 core 1100 volts grade flat / round, heavy duty, PVC insulated and overall PVC sheathed as in service connections twin core cable flat / round incl taking out existing U/S service cable of any size
Surface Dressing/Cleaning of various 11 KV sub-stations free from vegetation of any type including trimming of tree branches, bushes, creepers, etc. complete all as specified & directed. Note: 1. The frequency of surface dressing shall not be less than 2 months
M&L for repairing of LT existing panel Doors welding, cutting, inches, nuts, bolts etc
Supply & fix LT panel out door (Kiosk type) type, weather & vermin proof MS sheet housing 3.15mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on 40x40x6 mm angle iron frame, floor mounted type with one MCCB, 4 pole, 100 Amp, 25 KA 415 volts as incomer, copper bus bar 200 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections, after due approval of panel drawing including PCC pedestals of suitable size, removal of old unsv panel, making good the area complete all as specified and directed by Engr-in-charge.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type IP-54, floor mounted,compertmantalised and suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 40x40x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete (at Officer Mess) Incoming (a) MCCB 250 amps, 4 pole, 50Hz ,415 V with rupturing capacity 35 /36 KA-01 No Outgoing b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400Amp, 4 pole, not less than 60cm long - 01 set. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands.
S & F Bus bar electrolytic grade copper 400 Amp,
Laying only LT UG cable 16X4 core , 25X3.5 core to 150 X3.5 core
Laying only LT UG cable 185X3.5 core to 300 X3.5 core Note for Item No. 26 & 27 : LT UG cable will be issued under Sch 'B' as free for fixing only
S&F Commissioning and testing of steel 9 mtr GI octagonal pole - Top dia -70 mm, Bottom dia - 155 mm, section 1 (section length-7000mm) thick- 3mm, base plate - 260mmx260mmx16mm,hole in pole at a height of 300mm above above the planting depth with single arm bracket 1 mtr with 33.7mm OD GI pipe and individuals spike earthing with 8 SWG wire inclusive of civil foundation work, foundation bolt-M24x750mm (4Nos) built in control box with flush cover, singlearm, (9mtr), including junction box suitable in side the control box comprising of 6A SP MCB with terminals suitable for terminating incoming and outgoing cable of up to 3.5 core 16 sqmm 1.1 kv grade armoured pvc insulated and covered cables including bolt, nut & screws, clamp , including earth work and PCC etc,including Taking down as complete and as directed by engr-in-Charge
M&L for lifting of LT existing panel to hight of 450mm from ground using 40X40X6mm angle iron all including dismantling electrical connections welding, cutting, inches, nuts, bolts etc and pcc footings all as specified and directed by Engr-in- Charge.
Dismantling of existing LT panel, disconnecting existing, serviceable MCCBs/ACB and depositing in MES storeyard all as directed by Engineer-in-Charge.
M&L for painting of LT feeder pillar box one coat of of synthetic enamel paint all including preparation of surface etc all as specified and directed by Engr-in- Charge.
SM CONSTRUCTION COMPANY
DIVYA ASSOCIATES
M/S TRADE LINKERS
S.R.Enterprises
Stuti Trading Company
AUTOMATION AND SWITCHGEAR PANELS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .