Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC | L1 | Accepted-AOC valid | |
| 2 | L2₹35.0 L+₹3.3 L (10.5%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹35.8 L+₹4.1 L (13.1%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹40.9 L+₹9.2 L (29.1%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Feb 2022, 6:00 pmClosed
GE (AF) SURATGARH
GE (AF) SURATGARH
REPAIR MAINT MOTOR AND PUMPS SETS AND OTHER MISC WORK AT WATER SUPPLY INSTALLATION REPAIR REPLACEMENT CEILING FANS EXHAUST FANS WALL MOUNTED FANS AND INTERNALWIRING AND ALLIED EM WORK OF WSA AT AF STATION SURATGARH
2021_MES_495037_2
8917/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
as per tender documents
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹70,000
Yes
1 Apr 2022
14 Jan 2022
7 Feb 2022
14 Jan 2022
4 Feb 2022
21 Jan 2022
Amount
BOQ (REPAIR/MAINT MOTOR AND PUMPS SETS AND OTHER MISC WORK AT WATER SUPPLY INSTALLATION, REPAIR/REPLACEMENT CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS AND INTERNALWIRING AND ALLIED E/M WORK OF WSA AT AF STATION SURATGARH)
(A) REPAIR/MAINT MOTOR AND PUMP SETS OF WATER SUPPLY INSTALLATION AND MAINT OF CHLORINE PLANTS AND OTHER MISC WORKS AT WATER SUPPLY INSTALLATION AT AF STATION SURATGARH
Disconnecting, dismantling and taking out the defective centrifugal pump set of capacity 75 HP Motor of Make “KIRLOSKAR" from foundation by opening of coupling, foundation bolts and spray painting with one coat of existing colour paint and writing SM/MES No with white paint including replacement of parts as per Item No 2 here-in-after and repair of parts as per item No 3 here-in-after including installing, commissioning and testing on full load, complete all as specified and directed by Engineer-in-Charge. Note : Spare parts and repair of parts shall be measured and paid seperately.
Supply only spare parts as under required in Srl item No.1.00 here-in-before complete all as specified and directed by Engr-in-charge:-
Supply only Centre ring.
Supply only ball bearing existing size. Make : NBC/ SKF/ ABL
Supply only pump motor coupling assembly with tyre.
Supply bearing bowl with ball bearing plate.
Repair to parts of pump required in Ser item No-01 above here-in-before, complete all as specified and directed.
Remetalling, Turning and grinding to pump shaft.
Repairing to bearing housing.
Repair to impeller seat.
Cutting to impeller shaft key way and fixing of lock nut.
Repair to motor cooling fan shaft.
Disconnecting, dismantling and taking out the defective centrifugal pump set of capacity 20HP to 30 HP Motor of Make “KIRLOSKAR" from foundation by opening of coupling, foundation bolts and spray painting with one coat of existing colour paint and writing SM/MES No with white paint including replacement of parts as per Item No 5 here-in-after and repair of parts as per item No 6 here-in-after including installing, commissioning and testing on full load, complete all as specified and directed by Engineer-in-Charge. Note : Spare parts and repair of parts shall be measured and paid seperately.
Supply only spare parts as under required in Srl item No.4.00 here-in-before complete all as specified and directed by Engr-in-charge:-
Supply only CI Impeller
Supply only CI Gland plate.
Supply only Centre ring.
Supply only ball bearing existing size. Make : NBC/ SKF/ ABL
Supply only pump motor coupling assembly with tyre.
Supply bearing bowl with ball bearing plate.
Repair to parts of pump reqired in Ser item No-04 here-in-before, complete all as specified and directed.
Remetalling, Turning and grinding to pump shaft.
Repairing to bearing housing.
Repair to impeller seat.
Cutting to impeller shaft key way and fixing of lock nut.
Repair to motor cooling fan shaft.
Disconnecting, dismantling and taking out the defective centrifugal pump set of capacity 7.5/10 HP Motor of Make “KIRLOSKAR" from foundation by opening of coupling, foundation bolts and spray painting with one coat of existing colour paint and writing SM/MES No with white paint including replacement of parts as per Item No 8 here-in-after and repair of parts as per item No 9 here-in-after including installing, commissioning and testing on full load, complete all as specified and directed by Engineer-in-Charge. Note : Spare parts and repair of parts shall be measured and paid seperately.
Supply only spare parts as under required in Srl item No.7 here-in-before complete all as specified and directed by Engr-in-charge:-
Supply only CI Impeller
Supply only CI Gland plate.
Supply only Centre ring.
Supply only ball bearing (existing size) : NBC/ SKF/ ABL
Supply only pump motor coupling assembly with tyre.
Supply bearing bowl with ball bearing plate.
Repair to parts of pump required in Ser item No-07 here-in-before, complete all as specified and directetd.
Remetalling, Turning and grinding to pump shaft.
Repairing to bearing housing.
Repair to impeller seat.
Cutting to impeller shaft key way and fixing of lock nut.
Repair to motor cooling fan shaft.
Note : Any other small items required to make functional, such as nut bolts, washers, gaskets etc are deemed to be included in item rate.
Disconnecting & dismantling the defective single phase/Three phase induction motor squirrel cage of any make and of capacity up to 3 HP 415 Volts, 50 HZ, 2850 RPM and rewinding the motor with super enamelled copper wire of first quality of existing size/gauge and weight including replacement of all insulation materials, varnish and all other petty items required to make motor functional and re-assembling the motor including installation commissioning and testing on full load complete all as specified and directed. Note:-(a) Transportation charges from installation to contractor works shop and back after repair are included in the rates quoted against the above items. (b) Cost of nuts, bolts, washers, connection plate, grease/ lubrication to bearing bushes etc, are deemed to be included in this item. (c) Old dismantled winding wire will be contractor property for which credit has been considered under schedule of credit.
Disconnecting & dismantling the defective single phase/Three phase induction motor squirrel cage of any make and of capacity up to 5 HP 415 Volts, 50 HZ, 2850 RPM and rewinding the motor with super enamelled copper wire of first quality of existing size/gauge and weight including replacement of all insulation materials, varnish and all other petty items required to make motor functional and re-assembling the motor including installation commissioning and testing on full load complete all as specified and directed. Note:- (a) Transportation charges from installation to contractor works shop and back after repair are included in the rates quoted against the above items. (b) Cost of nuts, bolts, washers, connection plate, grease/ lubrication to bearing bushes etc, are deemed to be included in this item. (c) Old dismantled winding wire will be contractor property for which credit has been considered under schedule of credit.
Disconnecting & dismantling the defective single phase/Three phase induction motor squirrel cage of any make and of capacity up to 7.5 HP 415 Volts, 50 HZ, 2850 RPM and rewinding the motor with super enamelled copper wire of first quality of existing size/gauge and weight including replacement of all insulation materials, varnish and all other petty items required to make motor functional and re-assembling the motor including installation commissioning and testing on full load complete all as specified and directed. Note:- (a) Transportation charges from installation to contractor works shop and back after repair are included in the rates quoted against the above items. (b) Cost of nuts, bolts, washers, connection plate, grease/ lubrication to bearing bushes etc, are deemed to be included in this item. (c) Old dismantled winding wire will be contractor property for which credit has been considered under schedule of credit.
Disconnecting & dismantling the defective single phase/Three phase induction motor squirrel cage of any make and of capacity up to 10 HP 415 Volts, 50 HZ, 2850 RPM and rewinding the motor with super enamelled copper wire of first quality of existing size/gauge and weight including replacement of all insulation materials, varnish and all other petty items required to make motor functional and re-assembling the motor including installation commissioning and testing on full load complete all as specified and directed. Note:- (a) Transportation charges from installation to contractor works shop and back after repair are included in the rates quoted against the above items. (b) Cost of nuts, bolts, washers, connection plate, grease/ lubrication to bearing bushes etc, are deemed to be included in this item. (c) Old dismantled winding wire will be contractor property for which credit has been considered under schedule of credit.
Disconnecting & dismantling the defective single phase/Three phase induction motor squirrel cage of any make and of capacity up to 20 HP 415 Volts, 50 HZ, 2850 RPM and rewinding the motor with super enamelled copper wire of first quality of existing size/gauge and weight including replacement of all insulation materials, varnish and all other petty items required to make motor functional and re-assembling the motor including installation commissioning and testing on full load complete all as specified and directed. Note:-(a) Transportation charges from installation to contractor works shop and back after repair are included in the rates quoted against the above items. (b) Cost of nuts, bolts, washers, connection plate, grease/ lubrication to bearing bushes etc, are deemed to be included in this item. (c) Old dismantled winding wire will be contractor property for which credit has been considered under schedule of credit.
Disconnecting & dismantling the defective single phase/Three phase induction motor squirrel cage of any make and of capacity up to 25 HP 415 Volts, 50 HZ, 2850 RPM and rewinding the motor with super enamelled copper wire of first quality of existing size/gauge and weight including replacement of all insulation materials, varnish and all other petty items required to make motor functional and re-assembling the motor including installation commissioning and testing on full load complete all as specified and directed. Note:- (a) Transportation charges from installation to contractor works shop and back after repair are included in the rates quoted against the above items. (b) Cost of nuts, bolts, washers, connection plate, grease/ lubrication to bearing bushes etc, are deemed to be included in this item. (c) Old dismantled winding wire will be contractor property for which credit has been considered under schedule of credit.
Disconnecting & dismantling the defective single phase/Three phase induction motor squirrel cage of any make and of capacity up to 30 HP 415 Volts, 50 HZ, 2850 RPM and rewinding the motor with super enamelled copper wire of first quality of existing size/gauge and weight including replacement of all insulation materials, varnish and all other petty items required to make motor functional and re-assembling the motor including installation commissioning and testing on full load complete all as specified and directed. Note:-(a) Transportation charges from installation to contractor works shop and back after repair are included in the rates quoted against the above items. (b) Cost of nuts, bolts, washers, connection plate, grease/ lubrication to bearing bushes etc, are deemed to be included in this item. (c) Old dismantled winding wire will be contractor property for which credit has been considered under schedule of credit.
Disconnecting & dismantling the defective single phase/Three phase induction motor squirrel cage of any make and of capacity up to 75 HP 415 Volts, 50 HZ, 2850 RPM and rewinding the motor with super enamelled copper wire of first quality of existing size/gauge and weight including replacement of all insulation materials, varnish and all other petty items required to make motor functional and re-assembling the motor including installation commissioning and testing on full load complete all as specified and directed. Note:-(a) Transportation charges from installation to contractor works shop and back after repair are included in the rates quoted against the above items. (b) Cost of nuts, bolts, washers, connection plate, grease/ lubrication to bearing bushes etc, are deemed to be included in this item. (c) Old dismantled winding wire will be contractor property for which credit has been considered under schedule of credit.
Dismantling/taking out defective submersible pump set of capacity 15 HP from bore well/open well for repair by means of chain pully block or other T&P, transporting to workshop opening the pump set including repair/replacement of worn out parts, oiling/greasing, lubricating the parts and reassembling, shifting back to bore well, lowering commissioning and testing on full load complete all as specified and directed.
Rewinding of defective submersible motor of 15 HP with PVC copper winding wire of existing gauge and weight including replacement of all insulation material, "O" rings and other petty items required for making motor functional complete all as specified and directed.
Supply only spare parts as under required in Srl item No.18 here-in-before complete all as specified and directed by Engr-in-charge:-
Supply only water seal.
Supply only cable seal.
Supply only Gun metal bearing bush.
Supply only thrust bearing complete
Supply stainless steel distance sleeve.
Supply steel impeller bowl.
Supply stainless steel motor coupling with seal.
Supply packing sheet.
Supply Guide bush.
Supply cast iron stage bowl.
REPAIR TO PARTS OF SUBMERSIBLE PUMP SET required under item No-18 above:-
Straightening of pump shaft by re-meting welding.grinding etc.
Repair/refixing of distance pieces.
Repair to pump stage housing by seat cutting and bush Fixing.
Dismantling/taking out defective submersible pump set of capacity 7.5HP from bore well/open well for repair by means of chain pully block or other T&P, transporting to workshop opening the pump set including repair/replacement of worn out parts, oiling/greasing, lubricating the parts and reassembling, shifting back to bore well, lowering commissioning and testing on full load complete all as specified and directed. Note : Spare parts & repairs as required will be measured and paid seperately
Rewinding of defective submersible motor of 7.5 HP with PVC copper winding wire of existing gauge and weight including replacement of all insulation material, "O" rings and other petty items required for making motor functional complete all as specified and directed.
Supply only spare parts as under required in Srl item No.22 here-in-before complete all as specified and directed by Engr-in-charge:-
Supply only water seal.
Supply only cable seal.
Supply only Gun metal bearing bush.
Supply only thrust bearing complete
Supply stainless steel distance sleeve.
Supply steel impeller bowl.
Supply stainless steel motor coupling with seal.
Supply packing sheet.
Supply Guide bush.
Supply cast iron stage bowl.
REPAIR TO PARTS OF SUBMERSIBLE PUMP SET reqired under item No-22 above:-
Straightening of pump shaft by re-meting welding.grinding etc.
Repair/refixing of distance pieces.
Repair to pump stage housing by seat cutting and bush fixing.
Dismantling/taking out defective submersible pump set of capacity 5HP from bore well/open well for repair by means of chain pully block or other T&P, transporting to workshop opening the pump set including repair/replacement of worn out parts, oiling/greasing, lubricating the parts and reassembling, shifting back to bore well, lowering commissioning and testing on full load complete all as specified and directed. Note : Spare parts & repairs as required will be measured and paid seperately
Rewinding of defective submersible motor of 5 HP with PVC copper winding wire of existing gauge and weight including replacement of all insulation material, "O" rings and other petty items required for making motor functional complete all as directed.
Supply only spare parts as under required in Srl item No.26 here-in-before complete all as specified and directed by Engr-in-charge:-
Supply only water seal.
Supply only cable seal.
Supply only Gun metal bearing bush.
Supply only thrust bearing complete
Supply stainless steel distance sleeve.
Supply steel impeller bowl.
Supply stainless steel motor coupling with seal.
Supply packing sheet.
Supply Guide bush.
Supply cast iron stage bowl.
REPAIR TO PARTS OF SUBMERSIBLE PUMP SET reqired under item No-26 above:-
Straightening of pump shaft by re-meting welding.grinding etc.
Repair/refixing of distance pieces.
Repair to pump stage housing by seat cutting and bush Fixing.
Demolition of brick work or stone/boulder masonary built in cement mortar including all, quions, arches, pillars, etc, but excluding ashlar facings dressed stone work and precast concrete articles, complete all as specified and directed.
M&L for brickwork with subclass B bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6, complete all as specified and directed.
Taking down old LT outdoor panel of any size and description with accessories including disconnecting all cable connections from the panel and Supply, installation, testing and commissioning of LT outdoor type, factory made, fabricated CPRI approved panel board cubical type, front cover with screwed knobs bending of edge at front cover with providing suitable rubber gasket of size (1.50 mtr x 1.20 mtr x 0.6 mtr ) double door weather, dust and vermin proof, both front & rear openable made out of 3.15 mm thick CRCA sheet supported with 50x50x6mm MS angle iron support, welded with extended legs embedded in and including PCC 1:3:6 including cable entry /exist through gland at bottom including powder coated factory painting on both outer and inner surface of panel internal connection of bus bar (of rating 400 Amp 3 phase 4 wire) to MCCB with lugs complete all as specified and as directed including the following accessories :- INCOMING:- (a) MCCB 4 Pole,with thermal and magnetic Release, 25 KA breaking capacity, 160-200 AMP with over load setting , Make:L&T Type DN1-250C cat no.CM90642OONO-01Nos (b) Copper bus bar of capacity 400 AMP- 4 Nos (c) LED lamp RYB-01 Set (d) Volt meter 0-500 Volts -01 No OUTGOING:- (a) MCCB Four Pole with thermal release phase 80-100 Amps, 18 KA breaking capacity - 03 Nos Make L&T Type DU100D cat No.CM90518OOKO (b) AMP meter with suitable size LT CT Coil 0-200 AMP - 01 No
S & F GI column pipe medium grade ISI marked of size 80 mm bore each of three mtrs length and both end flanged including making cut mark in flanges for smooth lowering into the tubewell alongwith suitable size nuts, bolts and washers etc, in replacement of existing u/s pipes complete all as specified and directed.
S & F GI column pipe medium grade ISI marked of size 100 mm bore each of three mtrs length and both end flanged including making cut mark in flanges for smooth lowering into the tubewell alongwith suitable size nuts, bolts and washers etc, in replacement of existing u/s pipes complete all as specified and directed.
Labour for servicing of LT starter panel in pump houses for safety checking and setting of relay and removing unserviceable copper cable and rewiring of existing size of copper cable removing burned contactors,single phase preventer,stadared operating coil and over load relay and fixing,commissioning and testing contactors,single phase preventer,standard operating coil and over load relay complete all as specified and as directed. Note: 1.Contactors,single phase preventer and over load relays are paid seperately. 2.Any other items required to make functional is deemed to be included in this quoted rate.
Supply only single phase preventor suitable for 3 phase, 415 Volts including all necessary wiring.
Supply only 3 pole power contactor ML-2. 32A Including sidemounting Add-on-aux.Contact block of existing sizeMake : L&T cat no. SS90701 or equivalent.
Supply only 3 pole power contactor ML-3 40 AMP. Including sidemounting Add-on-aux.Contact block of existing size Make : L&T cat no. SS90721or equivalent.
Supply only 2 pole power contactor MNX-50. Including side mounting Add-on-aux.Contact block of existing size Make : L&T cat no. CS94061or equivalent.
Supply only 2 pole power contactor MNX-70. Including sidemounting Add-on-aux.Contact block of existing size Make : L&T cat no. CS94062or equivalent.
Supply only stadard operating coil ML1.5 for voltage 440 Make : /L&T cat no.SS90873POOO or equivalent.
Supply only overload relay range 13-22Amp, Make: L&T cat part No.CS90207OODO or equivalent.
Supply only overload relay range 13-21/20-32 Amp 230 Volt. Make : L&T cat no.SS91859OOCO/SS91859OOEO or equivalent.
Supply and fix in replacement of overload relay range 28-42 amp. Make : L&T/BCH
Removing old unserviceable starter of any type and supply and fixing testing and commissioning DOL starter, AC 3 phase, 415 Volt, 50 Hz with sheet metal enclosure with wide band coil heavy duty with single phase preventer suitable for 10 HP motor including making connection with suitable size of copper cable complete all as specified and as directed. Make: L&T TYPE MU-G10H DOL HSN CODE 8536 CAT NO OF COIL VOLTAGE 360 VOLTAGE SS95974COFO OAND CAT NO. OF COIL VOLTAGE 415 V IS SS95974DOFO
Removing old unserviceable starter of any type and supply and fixing testing and commissioning of single phase submersible pump controller, 230 Volt, 50 Hz with sheet metal enclosure with ammeter and volt meter, heavy duty suitable for 5 HP submersible pump including making connection with suitable size of copper cable, Relay range 20-32 Amp,start capacitor 275V,50HZ MFD and run capacitor 440 V,50Hz MFD complete all as specified and as directed. Make: L&T TYPE MR-G3 FASD HSN CODE 8536 CAT NO CS96167BEEJ
Demolition of cement concrete of any description and in any position, complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 Type D2 using 40mm graded aggregate for base foundation for all around row water storage tanks ,water supply installation complete all as specified and as directed.
Repair excluding spares of the Automatic water supply system installed at AF Stn Suratgarh including carrying out complete maintenance/serving/repairs as required of all the sub systems viz. PLC based control panels (with all the accessories), Mimic Panel, breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts / new parts if any including the followings and all as specified and directed by Engineer-in-Charge:-
Equipments:- (i) Automation Master Panel at water supply treatment plant. (ii) Automation Slave Panel each at all OHTs. (iii) Automation Master Panel at Booster PH No. Clear Sump (iv) Automation Slave Panel for Borewell each at ATC OHT. (v) Mimic panel Notes:- (i) New parts if any shall be paid under separate items as supply only. (ii) The scope of work includes the charges required for removing, repairing, refixing, carrying out electrical termination and fixing/installing, testing, commissioning, etc and all as directed.
Servicing of Pressure Switch i.e Cleaning checking for wear and tear, checking electrical termination, testing as directed by the Engineer-In-Charge. (once every month) and Breakdown maintenance and replacement of unserviceable parts if any all as specified and directed by the Engineer-in-Charge:- Note:- (i) The scope of work includes only labour charges required for removing, repairing, refixing of serviceable old parts / new if any carrying out electrical termination and fixing/ installing, testing, commissioning etc. (ii) New parts if any shall be paid under separate item as supply only.
Servicing of Solenoid Valves of size 10mm/15mm i.e Cleaning checking for wear and tear, checking electrical termination, testing as directed by the Engineer-In-Charge. (once every month) and Breakdown maintenance and replacement of unserviceable parts if any all as specified and directed by the Engineer-in-Charge:- Note:- (i) The scope of work includes only labour charges required for removing, repairing, refixing of serviceable old parts / new if any carrying out electrical termination and fixing/ installing, testing, commissioning etc. (ii) New parts if any shall be paid under separate item as supply only.
Servicing of Motorised Butterfly Valves and connected items of Size200/ 150mm/100/80mm i/e cleaning, greasing, checking for wear and tear, checking electrical termination, testing as directed by the Engineer-In-Charge (once every one month) and Breakdown maintenance and replacement of unserviceable parts, refixing of serviceable parts / new parts if any testing, commissioning etc and all as specified and directed. Note : (i) The scope of work includes only labour charges required for removing, repairing, refixing carrying out electrical termination, and fixing/ installing, testing and commissioning etc. (ii) New parts if any shall be paid under separate item as supply only.
Servicing of Magnetic switch sensor i.e. cleaning, checking for wear and tear, checking electrical termination, testing, as directed by the Engineer-In-Charge. (once every month) and Breakdown Maintenance and replacement of unserviceable parts, refixing of old serviceable parts / new parts if any testing, commissioning etc and all as specified and directed. Note : (i) The scope of work includes only labour charges required for removing, repairing, refixing carrying out electrical termination, and fixing/ installing, testing and commissioning etc. (ii) New parts if any shall be paid under separate item as supply only.
Supply only Relay - 4 C/O, 220V Make : LEONE / IDEC/L&T
Supply only Relay– 4 C/O, 240 V Make : LEONE / IDEC/L&T
Supply only Indicator lamp of Colour : Red / Yellow / Green Make : ESBEE / Telemacnique /L&T
Supply only Push Button with LED Indicator - 240V A.C. (Colour : Red / Yellow / Green) Make : ESBEE / Telemacnique / L&T
Supply only Rust Proof Maintenance free Mangentic Float Switch Sensor. Make : RDS or equivalent.
Supply only Coil for Solenoid Valve - 10mm / 15mm 230 V AC. Make : AVCON or equivalent.
Supply only Pressure Switch 0 – 10 Kg/sq.cm. Make: Indfos/Danfoss/L&T
Supply only Electric motor suitable for actuator for 200 mm dia. Butterfly valve Make : Ritetork or equivalent.
Supply only Electric motor suitable for actuator for 150 mm dia. Butterfly valve Make : Ritetork or equivalent.
Supply only Electric motor suitable for actuator for 100 mm dia. Butterfly valve Make : Ritetork or equivalent.
Supply only Electric motor suitable for actuator for 80 mm dia. Butterfly valve Make : Ritetork or equivalent.
Supply only Capacitor for Actuator suitable for80mm/ 100mm / 150mm / 200mm dia. Butterfly Valve Make : Ritetork or equivalent.
Supply only Resistor for Actuator suitable for 50mm / 80 mm/ 100mm / 150mm / Butterfly Valve Make : Ritetork or equivalent.
Supply only Limit Switch for Actuator suitable for 50 mm/80mm/ 100mm / 150 mm/200mm dia Butterfly Valve Make : Ritetork or equivalent.
Supply only 5 pair 0.5 mm dia. armoured copper cable for sensor. Make: Havells/Nicco/Plaza/Polycab
Supply only 6 Core 1.5 sq. mm PVC sheath PVC insulated copper armoured cable.Make: Havells/Nicco/Plaza/Polycab
Supply only 4 Core 1.5sq.mm. PVC sheath PVC insulated copper armoured cable. Make: Havells/Nicco/Plaza/Polycab
Supply only 2 Core 1.5sq.mm. PVC sheath PVC insulated copper armoured cable. Make: Havells/Nicco/Plaza/Polycab
Supply, installation, testing and commissioning of Motor actuated Butterfly valve with the following specifications including all accessories as required:- (a) Valve size : 100 mm bore. (b) Designed line pressure : 1- 10 Kg/ Sq.cm. (c) Operating Angle : 90 degrees. (d) Disc material : Cast iron with nylon coating. (e) Limit switches : 02 Nos for opening and closing. (f) Mounting : Splash proof. (g) Input power supply : 230 Vots, AC, 50 Hz. (h) In built wireless modren compatibility for remote communication. (j) Valve position indicator with an output of 4 – 20 mA. (k) The actuator should be capable of accepting 4-20mA of input for regulating purposes. (l) Manual operation : Hand wheel. Make: MARSH(emtork)/RITETORK/ HASSEL HOFENER/ RECKTRONIC DEVICES & SYSTEMS or equivalent as approved by Accepting Officer
Supply, installation, testing and commissioning of Motor actuated Butterfly valve with the following specifications including all accessories as required:- (a) Valve size : 150 mm bore. (b) Designed line pressure : 1- 10 Kg/ Sq.cm. (c) Operating Angle : 90 degrees. (d) Disc material : Cast iron with nylon coating. (e) Limit switches : 02 Nos for opening and closing. (f) Mounting : Splash proof. (g) Input power supply : 230 Vots, AC, 50 Hz. (h) In built wireless modren compatibility for remote communication. (j) Valve position indicator with an output of 4 – 20 mA. (k) The actuator should be capable of accepting 4-20mA of input for regulating purposes. (l) Manual operation : Hand wheel. Make: MARSH(emtork)RITETORK/ HASSEL HOFENER/ RECKTRONIC DEVICES & SYSTEMS or equivalent as approved by Accepting Officer
Supply, installation, testing and commissioning of Motor actuated Butterfly valve with the following specifications including all accessories as required:- (a) Valve size : 200 mm bore. (b) Designed line pressure : 1- 10 Kg/ Sq.cm. (c) Operating Angle : 90 degrees. (d) Disc material : Cast iron with nylon coating. (e) Limit switches : 02 Nos for opening and closing. (f) Mounting : Splash proof. (g) Input power supply : 230 Vots, AC, 50 Hz. (h) In built wireless modren compatibility for remote communication. (j) Valve position indicator with an output of 4 – 20 mA. (k) The actuator should be capable of accepting 4-20mA of input for regulating purposes. (l) Manual operation : Hand wheel. Make:MARSH(emtork)/ RITETORK/ HASSEL HOFENER/ RECKTRONIC DEVICES & SYSTEMS or equivalent as approved by Accepting Officer
Removing old unserviceable MCCBS and supply and fixing MCCBs 100 Amp 16 KA 4 pole 415 volt complete all as specified and as directed.
Removing old unserviceable Pressure switch and supply and fixing, testing of pressure switch for 0.5 HP booster pump made in Cropmton, Range :-0.2/+7.5 bar Pe and Diffrential :0.7/4bar, contact type: SPDT complete all as specified and as directed. Make :Danfoss/equivalent approved by GE
M&L of Earthing complete with galvanized iron or steel plate earth electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 25 x 4mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 50 x 50 x 60 mm, complete all as specified and directed by Engr-in-Charge.
Removing old unserviceable carbon bushes from Furculator and supply and fixing and testing of carbon bushes with holder of existing size complete all as specifed and as directed.
(B) REPAIR/MAINTANANCE OF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, PEDESTAL FANS AND AIR CIRCULATORS ALONG WITH ALLIED E/M WORKS AT AF STATION SURATGARH
Taking down unserviceable ceiling Fan of following sizes of any make dismantling cutting and removing of old burnt windings and rewinding with super enamelled copper winding wire of required size including allied insulation material, varnish, sleeves etc. greasing, oiling, re-assembling testing and refixing in the same position , complete all as specified and directed by the Engineer-in-Charge.
1200 mm sweep
1400 mm sweep
All as per description of serial item no 80 above but Exhaust Fan of following size and any make, complete all as specified and directed by the Engineer-in-Charge.
450 mm size
300 mm size
230 mm size
All as per description of serial item no. 80 but wall Fan of following size and any make, complete all as specified and directed by the Engineer-in-Charge.
450 mm size
600 mm size
All as per description of serial item no. 80 but Air circulator of following size and any make ,complete all as specified and directed by the Engineer-in-Charge.
450 mm size
600 mm size
750 mm size
Supply and fixing in replacement of capacitor of 3.15 Mfd including fixing complete and including necessary items such as sleeves etc, complete all as Specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of bush / bearing of suitable size in ceiling Fan of following size, complete all as specified and directed by the Engineer-in-Charge.
Ceiling Fan of 1200 mm sweep
Ceiling Fan of 1400 mm sweep
Supply and fixing in replacement of bush / bearing of suitable size in Exhaust Fan of following size, complete all as specified and directed by the Engineer-in-Charge.
Exhaust Fan of 450 mm sweep
Exhaust Fan of 300 mm sweep .
Exhaust Fan of 230 mm sweep
Supply and fixing in replacement of bush / bearing of suitable size in wall fans of following size, complete all as specified and directed by the Engineer-in-Charge.
Wall mounting fans of 450 mm sweep.
Wall fans of 600 mm sweep.
Supply and fixing in replacement of bush / bearing of suitable size in Air circulators Fan of following size, complete all as specified and directed by the Engineer-in-Charge.
Air circulator Fan of 450 mm sweep
Air circulators Fan of 600 mm sweep
Air circulators Fan of 750 mm sweep
Supply and fixing in replacement of Metallic clamps for hanging of ceiling Fan with bolts & nuts,, split pin etc., complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of starter of Ceiling Fan of following size, complete all as specified and directed by the Engineer-in-Charge.
Ceiling Fan of 1200 mm sweep
Ceiling Fan 1400 mm sweep
Supply and fixing in replacement of Rotor of ceiling Fan of following capacity, complete all as specified and directed by the Engineer-in-Charge
Ceiling Fan of 1200 mm sweep
Ceiling Fan 1400 mm sweep
Supply and fixing in replacement of PVC canopy for ceiling Fan (upper & lower) of following capacity, complete all as specified and directed by the Engineer-in-Charge.
Ceiling Fan of 1200 mm sweep
Ceiling Fan of 1400 mm sweep
Supply and fixing in replacement of Blade set for ceiling Fan of following capacity with bolts etc., complete all as specified and directed by the Engineer-in-Charge.
Ceiling Fan of 1200 mm sweep
Ceiling Fan of 1400 mm sweep
Supply and fixing in replacement of cast Aluminium Body cover for ceiling Fan of following capacity with bolts etc., complete all as specified and directed by the Engineer-in-Charge.
Ceiling Fan of 1200 mm sweep
Ceiling Fan of 1400 mm sweep
Supply and fixing in replacement of rubber reel/pad of suitable size for ceiling Fan of any size and make, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of MS down rod of length 450 mm for ceiling Fan of any size and make, complete all as specified and directed by the Engineer-in-Charge.
M&L for spray painting with synthetic enamel paint of (shade as approved by Engineer – in – Charge) after preparation of old surface of ceiling Fan/ exhaust Fan of any make/model/sweep and marking MES No with synthetic enamel paint, complete all as specified directed by the Engineer-in-Charge.
Supply and fixing in replacement of Metallic Blade set for Exhaust Fan of following size with bolts etc., complete all as specified and directed by the Engineer-in-Charge.
Exhaust Fan of 450 mm sweep .
Exhaust Fan of 300 mm sweep .
Exhaust Fan of 230 mm sweep
Supply and fixing in replacement of Metallic louvers for Exhaust Fan of following size with bolts etc., complete all as specified and directed by the Engineer-in-Charge.
Exhaust Fan of 450 mm sweep .
Exhaust Fan of 300 mm sweep .
Exhaust Fan of 230 mm sweep
Taking down ceiling Fan of any size, any make fixed/hanged at different location in Air Force area, dismantling the Fan and servicing, greasing, oiling and cleaning complete and re-assembling the same including replacing split pins flexible copper cable of size 23/0.0076 twin core, 70cm long and refixing the ceiling Fan on the same location in original position, testing and commissioning of Fan for smooth running, as per entire satisfaction of Engineer-in-Charge. Note:- (i)Quoted rate by tenderer of any item of the schedule is inclusive of taking down the ceiling Fan from the position for carrying out servicing repair transportation to work shop & back, changing any component and re-fixing/hanging in position connecting and testing complete.
All as per description of serial item No. 100 here-in-before but wall mounted Fan of any size and any make.
All as per description of serial item No. 100 here-in-before but Exhaust Fan of any size and any make
All as per description of serial item No.100 here-in-before but Air circulator fan of any size and any make
S&F in replacement sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amps , 240 Volts in replacment , complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminum point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and directed by Engineer-in-Charge. Note :- Temporary power supply shall be provided by contractor.
S&F Angle holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stepped type (0-4 step) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single plole, complete all as specified and directed.
S&F MCB SPN 32 amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc.,taking down old unserviceable MCBs, complete all as specified and directed by Engineer-in-Charge.
S & F in replacement circuit for single phase temperproof digital meter equipped with 6 digit ultra bright LED counter, direct operation upto 5-30 Amp (without CT), operating on 220 Volt single phase, direct read without multiplication factor, latest microcontroller based technology, Mains LED to indicate presence of auxillary supply, error indication for faulty/reverse connections etc, complete all as specified and directed by Engineer-in-Charge. Make:- HPL/L&T/Siemens.
(C) REPAIR AND MAINTENANCE OF INTERNAL WIRING AND ALLIED E/M WORKS WSA AT AF STATION SURATGARH
Taking down carefully copper/aluminium submain wiring of any size including conduit etc and making good disturbed surfaces of walls and floors complete all as specified and directed.
S&F in replacement Sub-main wiring with two single core 6 sq mm (nominal area) FRLS PVC insulated unsheathed stranded copper conductor cable in PVC conduit (concealed) including one run of 6 sqmm copper earth continuity wire, complete all as specified and directed by Engineer-in-Charge. Note :- 2 runs of 6 Sqmm & 1 run of 6 Sqmm cable and conduit shall be measured as single unit length.
S&F in replacement Sub-main wiring with four single core 6 sq mm (nominal area) FRLS PVC insulated unsheathed stranded copper conductor cable in PVC conduit (concealed) including one run of 6 sqmm copper earth continuity wire, complete all as specified and directed by Engineer-in-Charge. Note :- 4 runs of 6 Sqmm & 1 run of 6 Sqmm cable and conduit shall be measured as single unit length.
S&F in replacement Sub-main wiring with two single core 4.00 sq mm (nominal area) FRLS PVC insulated unsheathed stranded copper conductor cable in PVC conduit (concealed) including one run of 4 sqmm copper earth continuity wire, complete all as specified and directed by Engineer-in-Charge. Note :- 2 runs of 4 Sqmm & 1 run of 4 Sqmm cable conduit shall be measured as single unit length.
S&F sheet metal enclosures DB's for MCB TPN 4 Way, 415 volts with 200 amps rated busbar double door, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement isolator TPN of capacity 63 Amps 415 V, breaking capacity 10 KA, complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosures MCB SPN, DB's 8 way 240 Volts, with 200 Amps rated busbar double glazed door for incorporating MCB's, IP-43, complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 40 to 63 amps rating 240 volts, 10KA, 'C' curve complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 6 to 32 Amp rating 240 voltts, 10KA 'C' curve complete all as specified and directed.
S&F for LED light fitting 2x16 watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engr-in-Charge.
S&F for switch flame proof rotary type with termination box in LM6, 16A single pole 250 Volts, complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with copper conductor cables FRLS in stove enamelled steel conduit for flame proof fiting for one light point or one fan point controlled by one switch with 1.5 Sqmm size PVC single core unsheated cable, complete all as specified and directed.
Materail & Labour for earthing complete with glavanized steel earth plate electrode size 600x600x6mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal gorund level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including GI wire 4.00mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanized steel including GI pipe light grade of size of 15mm dia for protection and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No.6 connected to earthing test point all as specified or indicated including, complete all as specified and directed.
Dismantling existing unserviceable/deteriorated panel & removal from site and Supply, installation, testing and commissioning of LT panel indoor type dust & vermin proof self supporting fabricated out of CRCA steel sheet of 2mm thick base and 1.6mm thick other parts, suitably grouted minium 30 cm deep with PCC (1:3:6) cubicle type floor mounting suitable for 3 phase 4 wire, 415 volts, 50 Hz, AC supply, duly painted with powder coating, cables lugs are to be used to terminate calbes. All existing connections are to be re-done as directed by Engr-in-Charge. Following fitments shall deemed to be included in the cost of panel:- (A) INCOMING:- (i) TPN MCCB 400 Amps, Icu: 36KA therma magnetic and microprocessor based release. (ii) Phase indicating lamps LED type RYB. (iii) Panel mounted multi function energy meter for measuring voltage (0-500 volts) current (0-500Amps), frequency and power factor including resin dia cast CT of CT ratio 500/5 - 01 Nos (B) Bus Bar:- Electrolytic high conductivity insulated aluminium bus bar of capacity 600 Amps 04 Nos. (C)OUTGOING:- (i) MCCB TPN 250 Amps, Icu 25KA- 01 Nos. (ii) MCCB TPN 160 Amps, Icu 25KA - 02 No (iii) MCCB TPN 100 Amps, Icu 25KA - 02 No
S&F for PVC junction box of size 333x233x120mm (or nearest size) outdoor type with three phase and neutral, aluminium bus bar 25x4mm size and one MCB 6 Amps SP 10 KA including fixing with two nos flat iron 25x4mm clamps of suitable size with necessary mild steel nuts & bolts, complete all as specified and directed by Engr-in-Charge.
Taking down existing old unserviceable street light any type complete with bracket, complete all as specified and directed by Engr-in-Charge.
Dismentling existing old unserviceable cross arms of MS channel or angle section etc, complete with bracket, complete all as specified and directed by Engr-in-Charge.
Taking down existing old unserviceable LT cable of any type or size, complete all as specified and directed by Engr-in-Charge.
S&F for street light bracket made out of 60cm long 40mm dia light grade GI pipe welded to 200mm long 100mm GI pipe with provision of nut and bolts for fixing on top of the pole duly painted with two coats of silver paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
S&F for LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth in soft/loose soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches, complete all as specificed and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm thick in soil, complete all as specificed and directed by Engineer-in-Charge.
Removal of surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point , complete all as specificed and directed by Engineer-in-Charge.
M&L for sand cushioning 8cm before laying of cables and 15cm after laying of cables in sub staiton ducts/trenches and punned down, complete all as specificed and directed by Engineer-in-Charge. Note:- Punned down thickness shall be measured.
M&L for brick of common burnt clay, sub class 'B' old size bricks laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other, complete all as specified and directed by Engineer-in-Charge.
S&F XLPE insulated, armoured (Heavy duty), electric power cables with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 25 Sqmm 4 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles, complete all as specified and directed by Engineer-in-Charge.
S&F XLPE insulated armoured (Heavy duty), electric power cables with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 16 Sqmm 4 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles, complete all as specified and directed by Engineer-in-Charge. Note:- Earthwork and excavation shall be paid separately.
S&F XLPE insulated armoured (Heavy duty), electric power cables with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 70 Sqmm 3.5 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles, complete all as specified and directed by Engineer-in-Charge. Note:- Earthwork and excavation shall be paid separately.
S&F XLPE insulated armoured (Heavy duty) electric power cables with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 95 Sqmm 3.5 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles, complete all as specified and directed by Engineer-in-Charge. Note:- Earthwork and excavation shall be paid separately.
M&L for earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below ground levels with top edge of the earth plate not less than 1.5 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to galvanised iron strip 32x6mm earth lead by means of bolts, nuts, check nuts and washers, galvanized steel including GI pipe light grade 20mm dia bore for watering, funnel with wire mesh. CI cover with frame PCC chamber, pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical palte No.3 connected to earthing test point, complete all as specified and as directed by Engineer-in-Charge.
S&F for LT feeder piller box of size 450x300x200mm deep, 415 Volts, 3 phase, 4 wire 50Hz having 04 Nos aluminum bus bar of capacity 200 Amps mounted on porcelain insulators with suitable number of holes for making connections of cables, made out of 2mm thick sheet steel CRCA and mounted on frame of suitable size made out of angle iron 40x40x6mm with 4 nos legs embeded in PCC foundation 200mm below ground level and 300mm above ground level, duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, dust and vermin proof, front door with locking arrangement and two earth points by side of the box, cubical type with cabe glands, sockets etc and with provision of cable entry from bottom, including painting steel frame and taking out old unserviceable feeder piller box, complete all as specified and directed by Engineer-in-Charge. Note:- Drawing for LT feeder piller box shall be recommended by AGE E/M got approved by GE before fabrication.
S&F submain wiring in steel conduit with two run of single core 1.5 Sqmm FR PVC insulated copper conductor cables with one run of 1.5 sqmm cable for earth continuity complete all as specifed and directed.
M&L for point wiring (concealed) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick and 1.5 Sq mm copper earth continuity wire connected to earth dolly complete for the following , complete all as specified and directed by Engineer-in-Charge. Note : The disturbed surfacesof wall for concealing the wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate for point wiring shall be deemed to include the cost of making good surface.
One light/fan/exhaust fan point controlled by one switch.
One 3 pin switch socket outlet 6 amp on same board.
One 3 pin switch socket outlet 5 amp on indepndent board.
All as per item No 142 but one 3 pin socket outlet 15 Amps independent with size of cable 4 Sqmm, complete all as specified and directed.
S&F socket outlet, flush type 2 in 1,3 pin, 6 Amps, 240 Volts complete all as specified and directed.
S&F switch piano flush type single pole one way 6 Amps, 240 Volts complete all as specified and directed.
S&F socket outlet flush type 2 in 1,3 pin, 6 and 16 Amps, 240 Volts complete all as specified and directed.
S&F switch piano flush type single pole one way 16 Amps, 240 Volts complete all as specified and directed.
M&L ceiling rose, 3 phase/PVC polycarbonate, isolated body, complete all as specified and directed.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 16 of tender documents.
SHARMA CONSTRUCATION COMPANY
M/s JUGAL KISHORE MISHRA AND SONS
DASHMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .