Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.5 L+₹2.8 L (36.2%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹11.0 L+₹3.3 L (42.7%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹12.2 L+₹4.5 L (58.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹15.0 L+₹7.3 L (94.3%)Rejected-Finance 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
8 Aug 2022, 11:00 amClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
COMPREHENSIVE MAINT TO INTERNAL ELECTRIFICATION SYSTEM OF SMQs OF SMQs SOUTH CAMP, HAPPY HOME, CERTAIN OTM ACCN AND NEW PROJECT AT AF STN BAMRAULI
2022_MES_537126_1
8727/E8
Open Tender
Electrical and Maintenance Works
Works
270 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹30,000
12 Sept 2022
11 Jul 2022
9 Aug 2022
11 Jul 2022
8 Aug 2022
26 Jul 2022
Amount
Attending complaint and rectifying any type of fault in internal electrification such as decarbonising connection in the DBs checking for disconnections any burning due to over loading in DBs and restoring electric supply,checking and repair of switch sockets, MCBs any type, repair/replacement of tube light fitting, any type, by replacement of worn out ballast, bipin holder, starter, worn out wire, repair of faulty fan by disconnecting and replacement of worn out part such as capacitor, fan regulator, worn outwire, repair of lamp by replacement of worn out holder wire, earthing, repair replacement of other internal accessories which needs to serviceable the electric supply. Note :- .(1). Contractor shall be provided necessary T&P such as ladder, Earth, tester, Insulation tester, drill machine during rectification fault and nothing extra shall be paid to him on this account (2). The cost of insulation tape shall be deemed to be included in the unit rate quoted against relevant item (3) Complaint will be attended immediately as and when noted day and night
(a) Description all as above in item No-1 here-in-before but location South camp
(b) Description all as above in item No-1 here-in-before but location Happy Home
(c) Description all as above in item No-1 here-in-before but OTM accn
(c) Description all as above in item No-1 here-in-before but new project
Supply and fix in repair Switch piano 6 amps, single pole, one way, 230 volts
Supply and fix in repairSwitch piano 16 amps, single pole, one way 230 volts
Supply and fix in repair Socket outlet 6 Amp 2pin & 3 pin, flush type
Supply and fix in repair Socket out let, 16 amp and 6 amp, flush type
Supply and fix in repair Electronic fan regulator 5 step 230 volts,switch type.
Supply and fix in repair Electronic fan regulator 5 step 230 volts, socket size module.
Supply and fix in repair Lamp holder, insulated body, with back plate 230 Volt suitable for batten fittings.
Supply and fix in repair Capacitor 230 volt, 2.5 Mfd for ceiling fans
Supply and fix in repair Capacitor 230 volt, 3.15 Mfd for ceiling fans
Supply and fix in repair Switch piano modular type, 230 volts, single pole, one way, 10 Amp, one module.
Supply and fix in repair Switch modular type, 230 volts, single pole, one way, 16 Amp one module.
Supply and fix in repair Socket out let 5 pin, 10 Amp, 230 volts modular type.
Supply and fix in repair Socket out let 5 pin, 10 amp & 20 amp, 230 volts modular type.
Supply and fix in repair Halogen dichroic lamp 230 volt 50 watt with reflector.
Supply and fix in repair two 2-way switch 240 volt
Supply and fix in repair modular type regulator as per existing 120 watt.
Supply and fix in replacement calling bell ding dong type 220 volt 50 Htz
Supply and fix in replacement Switch socket combination 2 IN 1 3 PIN 6/16 Amp 220 Volt flush type.
Supply and fix in replacement of driver for 2x2 feet LED panel of 36 watt of any model any make as par existing 240 volt 50 Htz 120 watt/lumen 6500k/2700k.
Supply and fix in replacement Rope light complete with adaptor.
Supply and fix in replacement driver/ballast suitable for LED light 18 Watt
Supply and fix in repair LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2200 systems lumen outputwith lifetime of 50000 burning including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in repair LED batten luminaire surface mounted, 2 feet system wattage of 10 Watts, > 1000 systems lumen outputwith lifetime of 50000 burning including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in repair 2x2 LED fitting recess mounting flate panel 36 watt, down light 240 volt 50 Htz 150 luumen/watt comprising driver locking arrangement prewired completely.
Supply and fix in repair adore LED lamp 3 star rating 5 watt lumen out put 500 Lm all as specified and directed by Engr-in-Charge.
Supply and fix in replacement 18 Watt LED tube 4 pin type ultra bright LED PL-L with high efficacy suited for installation in existing 2G11 lamp holder Havells cat part No-PLL419TL18WLED865SPC of equivelent from list of makes.
Supply and fix in repair 2x2 occupancy sensor based recess mounted 36 watt 240 volt 50 Htz 150 watt/lume based hnigh transmitive diffuser suitable for indoor spaces aluminium housing.
supply and fix in repair LED Tube rod fittings inbuilt sensor based 4 feet long surface / wall mounted LED batten extruded aluminium/polycarbonate housing provided for efficiant heat dissipation with polycarbonate diffuser and intigrated electronic driver 20 watt including tube rod Havells cat part Endura liniar BS20WLED830SPCWH or equivelent from list of makes.
Supply and fix in repair wall mounted decorative facy type bedroom light LED type with frosted glass mounted on metalic frame with holder including 12 watt LED bulb Philips cat part No-45617 or equivelent from list of make.
Supply and fix in replacement LED flood light fitting high way 150 watt with surge protection 4KV inbuilt in driver and minium 10 KV seperate, IP 66 having pressure die cast aluminium housing with heat resistent toughened glass individual LED lenses complete making connection with suitable in size 3 core of wire and suitable for sustain 440 volt for 2-4 hour (ii) LM-79 and LM-80 test report with 50000 burning hrs LED life from NABL lab shall be provided (iii) CRI (Colour rendering index of fixtures shall be greater then 70) (iv) System lumen efficiancy shall be 150 lumen/watt complete all as specified and directed.
Supply and fix in replacement LED flood light fitting high way 200 watt with surge protection 4KV inbuilt in driver and minium 10 KV seperate, IP 66 having pressure die cast aluminium housing with heat resistent toughened glass individual LED lenses complete making connection with suitable in size 3 core of wire and suitable for sustain 440 volt for 2-4 hour (ii) LM-79 and LM-80 test report with 50000 burning hrs LED life from NABL lab shall be provided (iii) CRI (Colour rendering index of fixtures shall be greater then 70) (iv) System lumen efficiancy shall be 150 lumen/watt complete all as specified and directed. Make Philips/Havells/wipro/syska
Supply and fix in replacement 4.0 Sqmm FR PVC insulated stranded copper conductor cable 1100 volts grade all as specified and directed.
Supply and fix in replacement 6.0 Sqmm FR PVC insulated stranded copper conductor cable 1100 volts grade all as specified and directed.
Supply and fix in repair 10.0 Sqmm FR PVC insulated stranded copper conductor cable 1100 volts grade all as specified and directed.
Supply and fix in repair PVC gang box ISI marked three module for mounting one 5 amp socket & switch.
Supply and fix in repair PVC gang box ISI marked three module for mounting one 15 amp socket & switch.
Supply and fix in repair PVC gang box ISI marked six module for mounting two 5 amp socket & three switch.
Supply and fix in repair PVC gang box ISI marked 8 module for mounting three 5 amp socket & three switch
Taking down carefully aluminium batten point, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iv) Exhaust fan and ceiling fan shall be taken down in under separate item of this schedule.
M & L for point wiring with PVC insulated, PVC unsheathed cable single core, nominal area 1.5 sq mm FRLS with stranded copper conductor 1100 volts grade drawn into and incl rigid PVC conduit (concealed) 19 mm internal dia with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sq mm unsheathed copper conductor earth wire connected to earth dolly incl CI/MS boxes 1.6 mm thick with two coats of anticorrosive paint outside and aluminum paint inside sunk in wall with 3 mm thick laminated bakelite Hylam/Arkay light brand sheet cover (white) for mounting of switches, sockets and switch sockets, regulators as required complete all as specified and directed for the following Note :- The rates of chase cutting on wall concealing conduit and steel terminal boxes are included in the unit rates.Note- colour code of wire will be strictly followed , Red for Phase , Black for neutral and green for earth wire
(a) One light/fluorescent tube light/fan/bell point controlled by one switch single pole one way.
(b) One 3 pin 5 amp switch socket out let independent .
(c) One 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by engineer incharge.
(d) One 3 pin 5 Amps socket out let independent but below the switch board of light point in the same vertical plane
All as per item No 41 here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4.0 sq mm size as earth conductor for one 16 amp switch socket outlet on independent board.
Supply & fix switch piano flush type, single pole one way, 5 Amp.
S&F socket out let 2/3 pin 5 Amps flush type.
S&F socket out let 2 in 1, 3pin5 & 15 Amps flush type.
Supply & fix switch piano flush type, single pole one way, 15 Amp.
S & F ceiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed.
Supply and fix bell push AC 220 volt single phase
Supply and fix in repair bulkhead fitting enviornmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulkhead edgelit LED luminaire comprising of highbrightness LEDs of 10 watt Havells cat part No- Rugby Neon 10WLED760SSYMBOPC or equivalent from list of make.
S&F in repair Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 6.0 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Supply and fix in repair Factory made sheet metal enclosure distribution boards, (protection class IP-65) double door, vertiical type suitable for mounting isolator fixing MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, SP and N, 12 ways, 240 volts, Note : MCBs shall be measured and paid for separately under respective item of this schedule.
Supply and fix in repair Factory made sheet metal enclosure distribution boards, (protection class IP-42) double door, verticle type suitable for mounting MCCBS/ MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, triple pole and neutral, 8 ways, 415 volts. Note :- MCBs and MCCB shall be measured and paid for separately under respective item of this schedule.
Supply and fix in repair Factory made sheet metal enclosure distribution boards, (protection class IP-65) double door, vertiical type suitable for mounting isolator fixing MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, SP and N, 8 ways, 240 volts, Note : MCBs shall be measured and paid for separately under respective item of this schedule.
Supply and fix in repair Factory made sheet metal enclosure distribution boards, (protection class IP-42) double door, verticle type suitable for mounting isolator fixing MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, triple pole and neutral, 4 ways, 415 volts Note :- MCBs shall be measured and paid for separately under respective item of this schedule.
Supply and fix MCCB, four pole, 415 Volt ,100 Amp rating, 10 KA ultimate breaking capacity fixed in DBs catered herein before.
Supply and fix MCB, tripple pole and neutral, 415 volts, 35 to 63 Amps rating, 10KA, "C" series fixed in DBs catered herein before.
Supply and fix in replacement MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs catered herein before.
Supply and fix in replacement MCB, SP, 230 volts, 35 to 63 Amp rating, 10 KA, C series fixed in DBs catered herein before.
Supply and fix MCB, single pole and neutral, 230 volts, 40 to 63 Amp rating, 'C' series fixed in DBs catered here-in-before.
M&L for Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
Supply and fix connecting and testing LED street light 25 watt 6000k new generation energy saving and enviornmental friendly long life versatile pressure die cast aluminium housing IP-66 roadway luminaries with high power LED as light source and electronic driver complete with connection and accessories for fixing with with including grade 40mm dia GI pipe as bracket in appropriate length complete including taking down old light fitting.
Supply and fixing in repair Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz including louvers and for fixing of Exhaust fan and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge
Supply and fixing in repair Exhaust fan 230 mm sweep(steel Body) , 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz including louvers and for fixing of Exhaust fan and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge
S&F in repair Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply suitable for 250/200 mm size Fresh air fan as per sample complete all as spd and directed.
S&F exhaust fan motor capacity 1/4 HP 230 volts suitable for 230/300 mm size exhaust fan complete all as directed.
Supply and fixing in repair ventilating Fan 150 mm sweep, non metallic resin body, single phase 240 volts AC 50 Hz including louvers, and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge. Note : Old material deposited to MES store Yard
Supply and fixing in repair ventilating Fan 200 mm sweep, non metallic resin body, single phase 240 volts AC 50 Hz including louvers, and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge. Note : Old material deposited to MES store Yard
Supply and fixing in repair Ventilating Fan 250 mm sweep, non metallic resin body, single phase 240 volts AC 50 Hz including louvers, and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge. Note : Old material deposited to MES store Yard
Supply and fix in repair wall mounted fan 400mm size, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system complete all as specified and directed.
M & L in replacement twin core PVC insulated unarmoured cable 6 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor all as specified and directed by Engr-in-Charge.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
M/S A M ENTERPRISES
gangotri enteriprises
Ambrish Builders
chauhan construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .