Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.9 LAccepted-Finance 19 RAMESH NAGAR LALIT APARTMENT JAI BHAVANI MATA ROAD VILLAGE TOWN AMBOLI VILLAGE CITY ANDHERI WEST MUMBAI | 1 | Accepted-Finance Accepted |
Tender Value
₹21.7 L
EMD Value
₹43,496
Closing Date
4 Jul 2023, 6:00 pmClosed
EE(E)
The Executive Engineer (E), BSNL Electrical Division, 1st floor, Cantonment Exchange Bldg., MHS Compound, Near Poona Club, Opp. ISKCON Temple, Camp, Pune-411001
Operation and Comprehensive maintenance of EMS at Telecom compound RTTC, Chinchwad, Pune. ( SH - Attending of defects at the Risk and Cost of Ms Abhay Airconditioning services Pune against agreement no. 80.EEE. BSNL. PN.2018-19
2023_BSNL_154850_1
05/EEE/BSNL/PN/2023-24
Open Tender
Electrical Works
Item Rate
60 days
RTTC Chinchwad Pune
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
AO (Cash) BSNL Pune
₹43,496
6 Jul 2023
22 May 2023
6 Jul 2023
22 May 2023
4 Jul 2023
22 May 2023
Amount
Subhead I- 22 KV Outdoor Substation
Carrying out painting of four pole structure complete as reqd.
S/F following Guages
a) Oil temperature guage
b) winding guage
Supplying & Laying of 3 ½ X 300 sq mm Aluminium Armoured cable from Transformer-II to Feeder pillar complete as reqd.
a) 3 ½ X 300 sq mm Cable
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.
a) 3 1/2 x 300 sq mm
Carrying out painting of feeder pillar, Stands (ms angle) i/c complete cleaning of feeder pillar making dust free etc complete as reqd.
Making proper alignment of incoming side AB Switch (GOD).
Supply & fixing of following accessories for four pole structure (TR-I side) complete as reqd.
a) AB switch Post insulator
b) AB switch Pin insulator
c) D.O. fuses
d) LA (1 set comprises 3nos)
e) ACSR conductor
Subhead II- MV/LT/Distribution Panels
Complete servicing and repairing of Air Circuit Breakers including draw out from existing panel including cleaning of Jaw contact & Arc chute by using CRC/WD40, proper alignment and testing etc as required
a) 800 to 1250 Amps
b) 1600 to 2500 Amps
c) 3200 to 4000 Amps
Supply & fixing of following accessories for MV/LT/Distribution Panels complete as reqd.
a) LM/AA/BB type latch assembly
b) DN1 switch / relay
c) Indicators lamp (Red/Yellow)
d) Indicators lamp (Blue)
e) Indicating lamps (Red/Green) ON/OFF
f) Multifunction/ Intelligent meter
g) 10 KVAR Capacitor (type- MD-02)
h) 15 KVAR capacitor ( Type-MDXL)
i) 20 KVAR capacitor ( Type-MDXL)
j) Reed Type Frequency Meter 440/115 V~ range-45-55 Hz (type-RFS 96)
k) AC Voltmeter (0-600V ~) Class 1.0 accuracy , (96 x 96 ) mm
l) AC Ammeter (0-600Amps ~) Class 1.0 , (96*96) mm
S/F operating handles for following capacity L & T Make MCCB/ ACB/ SFU
a) Operating handle (M/s Crompton make 800Amp ACB)
S/F following spares i/c testing as reqd.
a) MCCB 200 Amps M/s L&T make (type DT200/DTH200) 3Pole
b) MCCB 125 Amp TPN
c) Switch (M/s L&T make 250 Amp SFU) type- FA
d) Switch (M/s L&T make 100 Amp SFU) type- FA
e) Switch (M/s L&T make 63 Amp SFU) type- FA
f) TPN connectors 32 Amp
g) TPN connectors 63 Amp
h) TPN connectors 125 Amp
i) Fuse link with fuse 100 Amp
j) HRC fuse 200 Amp
k) HRC fuse 100 Amp
l) HRC fuse 63 Amp
m) SPN MCB C 32Amp
n) SP MCB C6 Amp
o) TPN MCB C63A
p) TPN MCB C32A
Subhead III- EI , Fans, Compound Lights & Pumps
Supply & fixing of following accessories for existing fittings complete as reqd.
Fiting type 2 X 36 W CFL MASTER PL-L 36W/865/4P 1CT/25)
a) CFL Lamp ( PL-L 4P Lamp 36W)
b) Electronic Ballast
Fiting type 2 X 18 W CFL MASTER PL-C 18W/865/4P 1CT/5X10CC
a) CFL Lamp ( PL-L 4P Lamp 18W)
b) Electronic Ballast
Fiting type 2 X 18 W CFL MASTER PL-C 18W/865/2P 1CT/5X10CC
a) CFL Lamp ( PL-L 2P Lamp 18W)
b) Electronic Ballast
Fitting type 4 X 14 W FL T5 TL5 Essential 14W/865 1SL/40
a) CFL Lamp (TL5 Essential Tube 14W)
b) Electronic Ballast
Fitting type 3 x 11 W CFL PL-S 11W/840/2P 1CT/25
a) CFL Lamp (11 W CFL PL-S 11W)
b) Electronic Ballast
Fitting type 28 W TL5 Essential 28W/865 1SL/40
a) CFL Lamp ( 28 W TL5 Essential 28W)
Fitting type 36 Watt Box type and MO type
a) 36 W Tube light rod
b) 36 W copper ballast
c) 36 W Tube light starter
d) Ding Dong Bell
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required
a) 5/6 amps switch (piano type)
b) 15/16 A switch (piano type)
c) 3 pin 5/6 A socket outlet (piano type)
d) 6 pin 15/16 A socket outlet (piano type)
e)15 Amp Switch socket Combine Board
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a) 5/6 A switch
b) 3 pin 5/6 A socket outlet
c)18 Module Modular plate
Supply & fixing of following accessories for existing ceiling fans complete as reqd.
a) Regulator (resistance type)
b) Capacitor - 2.5 Mfd
c) Bearing (6201/6202)
Rewinding of 1200mm/ 1400mm ceiling fans and testing the fans complete as reqd.
Rewinding of 450mm exhaust fans and testing the fans complete as reqd.
Rewinding of wall mounted fans and testing the fans complete as reqd.
Supply & fixing of 1400mm ceiling fans complete as reqd.
Repairing of 25/15Ltr Geyser and testing the Geyser complete as reqd.
SITC of following accessories for Compound lighing etc. with connections, testing etc. complete as reqd.
250W HPSV ballast
70/250W HPSV ignitor
Capacitor 33 mfd
Capacitor 15 mfd
250W HPSV lamp
70W HPSV lamp
70 W HPSV copper ballast
Acrylic cover for 70W/250W HPSV fitting
36W LED Bracket
Supply & fixing of following accessories for Water Pump set & Panels complete as reqd.
a) RYB indicator
b) 63Amp HRC fuse
c) 63 Amp Connector
d) Non Return Valve 3" (76mm dia.) brass
e) Wheel valve 3" (76mm dia.) brass
f) Foot valve 3" (76mm dia.) brass
g) Foot valve 2" (76mm dia.) brass
h) 32Amp Connector
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a)Single pole
b)Single pole and neutral ( 20 Amp & 32 Amp)
Sub-Head IV- E/A Set
EA set No-1 (600 KVA)
a) S/F Air filter element
b) Attending Engine head oil leakage
c) Repairing of Fuel injector pump
EA set No-2 (600 KVA)
a) S/F Air filter element
b) Attending oil leakage from Oil tank near coupler
c) Repalcement of radiator sensor and assembly
d) Attending damaged silencer
EA set No-3 (600KVA)
a) Replacement of Exhaust Temp Guage
b) Repalcement of radiator sensor and assembly
c) S/F Air filter element
EA set No-4 (600 KVA)
a) Replacement of Exhaust Temp Guage
b) Repalcement of radiator sensor and assembly
c) Supply & fixing of Battery charger 24 V , 20 Amp
d) Attending oil leakage from Oil tank near coupler
e) S/F Air filter element
Subhead V- Fire Detection & Fire Alarm System
Supplying, installation, testing & commissioning of following accessories for Fire detection and Fire Alarm Panels complete as reqd.
a) 12V 7Ah Battery
b) Smoke Detector with built in LED and mounting base complete
c) Response Indicator on surface/recess MS box having two LEDs metallic cover complete
d) Hammer & Chain
e) DC Ammeter
f) Manual Call point assembly (Make-M/s Morley)
g) FM200 cylinder interconnected pipe with valve
h) Zone card
Repairing & maintenance of following accessories for Fire detection and Fire Alarm System complete as reqd. [4 Loop Panel - Make: M/s Morley, LCP-5 FM 200 system, 4 Zone Panel - Make: M/s Agni, 12 Zone Panel - Make: M/s Naveen, Make: M/s Reliance]
a) Panel Display faulty.
b) Exit Sign board
Subhead VI- M/s Batliboi make Ductable AC unit
Supplying and fixing of Compressor (Type-Scroll) Model- ZR72KC-TFD-522 i/c testing and commissioning complete as required.
Carrying out Nitrogen pressure with attending leakage testing, flushing the sysytem, brazing / flaring the leak point & Vaccuming, purging and making the sytem leak proof the complete sysytem of 5.5 TR ductable AC unit, complete testing as required.
Supplying & Charging / topping of refrigerent gas ( R22 ) in existing 5.5 TR ductable AC units compete sa required
Supplying & fixing of Induction Motor (type- 3ph, 415V, HP/KW-0.5/0.37, Frame- V80, RPM-900) for Condensor fan motor incluiding connection, testing complete as reqd.
Supplying & fixing of Single phse Induction Motor (type- 1ph, 220-240V, Watt- 65W, 6pole) for Condensor fan motor incluiding connection, testing complete as reqd.
Supplying & fixing of HP/LP cutout
Replacement of Faulty PCB card
a) ( Outdoor Unit)
b) Indoor Unit
Replacement of Faulty contactor ( Make- Siemens , Model 3TF 33, 3 pole , 25 Amps
S/F Capacitor
a) For PCB -- 2.5 MFD, 440 V
b) For Condensor Motor , 5 MFD 440 V
S/F Blower motor, 3 Phase, 415 Volt, 550 Watt for indoor Unit
S/F drier filter for indoor unit
Replacement of Faulty contactor ( Make- Siemens , 3 pole , 16 Amps) For indoor Unit
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .