| 1 | L1₹36.1 LAccepted-AOC 580 INDRA COLONY JAISALMER RAJASTHAN 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | ₹36.1 L Quoted ₹38.1 L | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹43.6 LRejected-Finance | ₹43.6 L | L2 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | Manisha Enterprises L2 | HINGLAZ ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down carefully existing unserviceable/perished conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/ conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators etc and making good the disturbed surfaces of wall/ceiling complete all as specified & directed. | 797 | Per Point | 6 ₹4,782 | 10 ₹7,970 |
| 2.00 | M&L for concealed conduit point wiring controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 25 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLSH copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly including sunken box for modular fitting complete all as specified and directed.(a) One light / fan point controlled by one, one way switch | 150 | Per Point | 690 ₹1.0 L | 590 ₹88,500 |
| 3.00 | All as per serial item No. 2.00 here-in-before but for one 3 Pin, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on independent board complete all as specified and directed. | 50 | Per Point | 690 ₹34,500 | 590 ₹29,500 |
| 4.00 | All as per serial item No. 2.00 here-in-before but for one 3 Pin, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on same board complete all as specified and directed. | 55 | Per Point | 90 ₹4,950 | 50 ₹2,750 |
| 5.00 | M&L for concealed conduit point wiring for controlled by one switch with PVC unsheathed single core multistranded FRLSH copper conductor cable of size 4 Sqmm (nominal area) in and including PVC conduit 25 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC cassing capping on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling including one run of PVC insulated FRLSH copper conductor cable of 4 Sqmm with green insulation as earth dolly for 6 pin, 16 Amp socket outlet on Independent board. | 50 | Per Point | 790 ₹39,500 | 500 ₹25,000 |
| 6.00 | Modular switch 6 Amps, 240 Volt, AC, one way, one module (ISI Marked) fixed as in repair complete all as specified and directed. | 255 | Each | 16 ₹4,080 | 90 ₹22,950 |
| 7.00 | Modular switch 20 Amps, 240 Volt, Single Pole, AC, one way with indicator one module (ISI Marked) fixed as in repair complete all as specified and directed. | 50 | Each | 75 ₹3,750 | 150 ₹7,500 |
| 8.00 | Modular Socket shuttered, 6 Amps, 240 volts, 2/3 Pin combined, Single Pole, universal India two module (ISI Marked) complete all as specified and directed. | 105 | Each | 38 ₹3,990 | 120 ₹12,600 |
| 9.00 | Modular Socket shuttered, 6/16 Amps, 240 volts, 2/3 Pin combined, Single Pole, two module (ISI Marked) complete all as specified and directed. | 50 | Each | 85 ₹4,250 | 250 ₹12,500 |
| 10.00 | Modular Fan Regulator, step type, 120 Watt, 2 module, 240 volts grade, (ISI Marked) fixed as in repair complete all as specified and directed. | 25 | Each | 230 ₹5,750 | 150 ₹3,750 |
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Dec 2025, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR/MAINT/REPLACEMENT TO INTERNAL ELECT, LIGHTING PROTECTION SYSTEM, EARTHING AND ALLIED WORKS AND E/M MISC ITEMS AT 3 AFRU UNDER GE (AF) JAISALMER
2025_MES_738692_1
8380/GE/E8
Open Tender
Miscellaneous Works
120 days
GE (AF) Jaisalmer
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹90,000
Yes
17 Dec 2025
7 Nov 2025
6 Dec 2025
7 Nov 2025
4 Dec 2025
20 Nov 2025
Amount
Taking down carefully existing unserviceable/perished conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/ conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators etc and making good the disturbed surfaces of wall/ceiling complete all as specified & directed.
M&L for concealed conduit point wiring controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 25 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLSH copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly including sunken box for modular fitting complete all as specified and directed.(a) One light / fan point controlled by one, one way switch
All as per serial item No. 2.00 here-in-before but for one 3 Pin, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on independent board complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 Pin, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on same board complete all as specified and directed.
M&L for concealed conduit point wiring for controlled by one switch with PVC unsheathed single core multistranded FRLSH copper conductor cable of size 4 Sqmm (nominal area) in and including PVC conduit 25 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC cassing capping on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling including one run of PVC insulated FRLSH copper conductor cable of 4 Sqmm with green insulation as earth dolly for 6 pin, 16 Amp socket outlet on Independent board.
Modular switch 6 Amps, 240 Volt, AC, one way, one module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular switch 20 Amps, 240 Volt, Single Pole, AC, one way with indicator one module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Socket shuttered, 6 Amps, 240 volts, 2/3 Pin combined, Single Pole, universal India two module (ISI Marked) complete all as specified and directed.
Modular Socket shuttered, 6/16 Amps, 240 volts, 2/3 Pin combined, Single Pole, two module (ISI Marked) complete all as specified and directed.
Modular Fan Regulator, step type, 120 Watt, 2 module, 240 volts grade, (ISI Marked) fixed as in repair complete all as specified and directed.
MCB Protected Socket (Modular AC Box, Metal clad box) Two Module, with Single Pole, MCB 20 Amps, repturing capacity 10 kA and neutral enclosure in sheet steel with a two pin and earth plug and socket including taking down old unserviceable complete all as specified and directed.
White colour modular blanking plate, one module blank complete all as specified and directed.
Ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC /Polycarbonate ,isolated body complete all as specified and as directed.
M&L for point wiring with PVC insuleted unsheathed 1100 Volts grade single core FRLSH multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC casing capping and accessories of size 25mm, fixed on wall/ ceiling etc with necessary fixing accessories and earth continuity conductor cable of size 1.5 Sqmm green colour Connected to common earth and earth dolly including cast iron/pressed steel terminal/wooden boxes(as per site requirment) Covered with laminated sheet top cover switches/ sockets/ fan regulators fixed with cadmium plated machine screws all as specified for the following:(a) One light / fan point controlled by one way switch
All as per serial item No. 14.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 14.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on same board complete all as specified and directed.
All as per serial item No. 14.00 here-in-before but for One one 3 pin 5 Amps socket outlet independent but below the switch board of light points in same vertical plane.
All as per serial item No. 14.00 here-in-before but one light point controlled by one 2 way switch
All as per SI No 14.00 here-in-before but with multi stranded copper conductor FRLSH cable, 1100 volts grade (ISI marked), PVC insulated and unsheathed of size 4 Sqmm single core and with and including 4 Sqmm PVC insulated unsheathed single core copper conductor cable as earth continuity conductor to common earth and earth dolly for one 15 Amp socket outlet point on the independent board complete all as specified and as directed
Switch piano, flush type, Single Pole, one way, 5/6 Amp, 240 Volts (ISI Marked) f complete all as specified and directed.
Switch piano, flush type, Single Pole, one way, 15/16 Amp, 240 Volts (ISI Marked) complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 5/6 Amps, flush type, 240 Volts (ISI Marked) complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 15/16 Amps, flush type, 240 Volts (ISI Marked) complete all as specified and directed.
Electronic fan regulator,Stepped type , flush type and connecting up, 120 watt, 230 volt (ISI marked) complete all as specified and directed.
Surface and wall mounted 10 watt LED bulk head fitting in engineering plastic housing with clear prismatic diffuser complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 including taking down old unserviceble LED fittings complete all as specified and directed.
Decorative ultra slim round profile LED tube light fittings of capacity 9 watt/10 watt LED 6000 K, basic all purpose surface and wall mounted LED batten with extruded polycarbonate housing & integrated electronic driver including taking down old unserviceble LED fittings complete all as specified and directed.
Decorative ultra slim square profile LED tube light fittings of capacity 18watt/20 watt four feet,LED 6500 K, basic all purpose surface and wall mounted LED batten with extruded polycarbonate housing & integrated electronic driver including taking down old unserviceble LED fittings complete all as specified and directed.
Cygnus series Recess mounting LED 36watt/40 watt 2' x 2' LED Slim Panel - 595x595 mm cat Part No CCR-126-50-40-SL-NWH of make- CG electric or equivalent in Philips/Havells/CG/Bajaj white powder coated aluminium extruded housing with LEDs including LED driver and fixing in recess ceiling suitable size of aluminium strip size as required for fixing of LED fitting complete with all accessories prewired fixed on ceiling and connecting up complete with 3 core flexible cable of size 23 / 0.0076 including taking down old unserviceable fitting complete all as specified and directed.
Sub main wiring with two single core 6.00 sqmm, PVC insulated unsheathed multistranded copper conductor FRLSH 1100 volts grade conforming to IS 694 including and 6.00 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLSH cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 25mm dia PVC conduit incl taking existing complete all as specified and directed. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor and one run 25mm dia PVC conduit shall be measured & paid as one unit (running metre).
Sub main wiring with two single core 4.00 sqmm, , PVC insulated unsheathed multistranded copper conductor FRLSH 1100 volts grade conforming to IS 694 including and 4.00 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLSH cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 25mm dia PVC conduit incl taking existing complete all as specified and directed. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and one run 25mm dia PVC conduit shall be measured & paid as one unit (running metre).
Sub main wiring with 2.50 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volts grade conforming to IS 694 including 2.50 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 2.50 sqmm cable and one run of 2.50 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
Sheet metal enclosure powder coated single phase DB SPN (2 +6 way) 8 ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 12 ways (2 +10) way)and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 4 ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure for VPTN DBs 4 way , double door, (IP-43) built in bus bars complete suitable for 415 Volts AC, 50 Hz , supply , suitable for incoming MCCB and outgoing MCBs and fixed in recess in brick masonary wall complete all as specified and directed.
MCB, Single Pole, 6 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles including complete, all as specified & directed.
MCB, SPN, 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
MCB, SPN, 40 to 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
MCB, TPN, 40 to 100 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to and including galvanized earth lead wire 4mm dia upto 7.5 metre by means of GI nuts, bolt, check nuts, washers thimbles, etc as shown in electrical plate No 03 SSR Part I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exc 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 15mm bore meter long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25mm x 3mm, bolts, nuts and washers 75mm thick RCC cover 1:2:4 type B-1 shall be provided on CI frame etc complete all as specified. Note - (i) PCC chamber shall be constructed at least 1.5m away from the earth electrode. The pipe for watering shall be provided in slanting manner. The cost of 7.50m GI pipe for protection of earth wire/strip .(ii) Quoted amount deemed to include the cost of excavation /earthwork , PCC pit , funnel , cover GI medium grade protectiom pipe.
MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC supply, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
Galvanized steel water tubing light grade of 40mm bore with clamp of 25x3mm flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors, complete all as specified and directed.
Galvanized steel water tubing light grade of 50mm bore with clamp of 25x3mm flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors, complete all as specified and directed.
Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 25mmx4mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No. 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 50mm bore GI pipe light grade for earth wire protection fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/Sqm in lieu of CI cover etc including taking down old earth complete all as specified and directed. Note : (i) The unit rate shall be deemed to included for Test point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the contractor.
GI strip 25mm X 4mm buried in ground and connected with aluminium strip by means of brazing fixed as in repair complete all as specified.
Supply, fixing and connecting of copper strip 20 x 3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete in and including taking down of existing strip complete all as specified and directed at site
Air termination, single pointed, copper rod 12mm dia and 300mm longand fixing to GI pipe with clamps, nuts, bolts and washers complete in and including taking down of existing complete all as specified and directed
Test point terminal block made of gun metal or phosphorus bronze 75mm x 75mmx 25 mm, drilled and screwed including 3 No. 8 mm dia 25 mm long hexagonal in and including dismantling of existing test point complete all as specified and directed
Ceiling Fan 1200mm sweep, BLDC (Brush less direct current), min air delevery 210 CFM with service value 6.00 BEE,five star rated ,single phase, AC supply, 240 Volt, including canopies, three number blades, down rod, double ball bearing with capacitor of 2.5 mfd, and including PVC insulated PVC sheathed copper conductor flexible cable 3 core of suitable size from ceiling rose or connector to fan including marking of MES number and taking down old unsv fan and deposited to MES store complete all as specified and directed.
Exhaust Fan 300mm sweep, BEE approved, ISI Marked with mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn in flexible PVC conduit from ceiling rose or connector to fan including marking of MES number and fixed by using 4 Nos, bolts, nuts and washers and grouted in wall in CM 1:3 complete all as specified and directed.
Pedestal fan, sprint Hi speed, stand along unit with base and stand AC single Phase. 230V of size 400mm sweep with, blades, frame and protection arrangement including taking down of old unserviceable fan and deposition of the same in MES store yard at Jaisalmer complete all as specified and directed at site.
Supply, laying, jointing and testing 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor cable 10 sqmm, twin core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire including taking down old unserviceable cable complete all as specified and directed.
Lamp holder angular type,PVC/Polycarbonate type with cord grip cap suitable for pendent fitting B-22 base including taking down old unserviceable Lamp holder complete all as specified and directed .
Wooden board for mounting of switches/sockets or other switches of sizes 190x240mm, thickness of wood wall shall not be less than 13mm thick, the board shall be enclosed from all sides and back including taking out existing complete all as specifed and directed
Wooden board for mounting of switches/sockets or other switches of sizes 300x300mm, thickness of wood wall shall not be less than 13mm thick, the board shall be enclosed from all sides and back including taking out existingcomplete all as specifed and directed
Acrelic sheet, electric grade for fixing of switches/sockets or other similer nature items of sizes 190x240mm, 3mm thick, dully cutting for mounting of switches/sockets as required in and including necessary screws for fixing on wooden board complete all as specifed and directed
Acrelic sheet, electric grade for fixing of switches/sockets or other similer nature items of sizes 300x300mm, 3mm thick, dully cutting for mounting of switches/sockets as required in and including necessary screws for fixing on wooden board complete all as specifed and directed
PVC elastomer insulated and flat, sheathed, multcore industrial flexible cable with bright annealed copper conductor of flat cable size 1.5 sqmm, 3 core for electric connection from feeder /looping box /street light over head line to street light fittings including taking out old unserviceable cable from pole all as specified and directed.
PVC elastomer insulated and flat, sheathed, multcore industrial flexible cable with bright annealed copper conductor of flat cable size 2.5 sqmm, 3 core for electric connection from feeder /looping box /street light over head line to street light fittings including taking out old unserviceable cable from pole all as specified and directed.
Street light of capacity 30 watt with inbuilt driver having pressure die cast aluminium housing IP-66 having efficiency of > 100 Lumens / watt , operating voltage -120-270- Volts, P.F >0.95, T.H.D < 10%, suitable for 30 to 40 mm O.D mounting pipe and suitable for mounting on wall/ pole with necessary Mounting arrangement including connecting up with three core flexible copper conductor cable with suitable size , Mounting pipe/ brackets , nut bolt and accessories inclusdin diconnecting & taking down old unserviceable light complete all as specified and as directed . Crompton Cat part No TPR-400-30-57 SL-LM- NSR or Equivalent to Philips.
Decorative water proof Up Down 2 way LED Wall Lamp of capacity up to 6 watt , 6 ray warm colour with IP 65 water proof rating, made from weather resistant aluminium and plastic, the lamp is built to withstand outdoor elements while the multi color light creates a welcoming ambiance including taking down old unserviceble LED fittings complete all as specified and directed.
Servicing and maintenance of Storage type Electric, Water Heater (Geyser) of storage capacity 25/ 35/50 Ltrs comprising of the following work at different locations of any make complete all as specified and directed. (a) Inspection, taking down , opening (dismantling), brushing, cleaning of storage tank and painting internally with one coat of proprietery bituminous composition not liable to impart test or otherwise contaminate the water. (b) Examining water tightness of storage tank after cleaning. (c) Carryout operation of all stock cocks, pressure reducing valves etc to ensure free movement of the working parts. (d) Replace washers and glands of all taps and ball valves to ensure water tightness. (e) Inspect overflow/ vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check maintain and refitting the thermostat and test its functioning. (h) Checking and adjustment of pressure reducing valves. (j) Checking of dead weight type high pressure release valves (PRV) by removing dead weight protection , cleaning the seat and ensuring that the vest hole is not blocked/ choked. (k) Visual examination of fusible plug to ensure its intactness. (l) Descaling of immersion type heating element and cleaning with diluted hydrochloric acid or clear pedette. (m) Replacement/ Repair of neon lamp/ indicator lamp. (n) Testing of Geyser after repairs.
Supply, installation and testing electric water heater, horizontal type, steel body with copper inner tank and heating element 2 KW, capacity 25 litre BEE 5 star rated complete with all assessories such as safety valve, thermostate, NRV, PVC connection pieces etc including taking down old unserviceable complete all as specified and directed.
Supply, installation and testing electric instant water heater, with copper inner tank and heating element 3 KW, capacity 5 litre complete with all assessories such as safety valve, thermostate, NRV, PVC connection pieces etc including taking down old unserviceable complete all as specified and directed.
supply and fixing of wooden box with sunmica top switch board alongwith one 5 Amp and 15 Amp switch socket combination including one battern holder with one LED bulb 9 watt alongwith internal 4 Sqmm wiring with extension cable 3 mtr length all as specified and directed
supply and fixing of motion sensor led light works great for home indoor environmental production with auto mode instant on off switch with inbuilt in 400mAh lithium battery including taking down old unserviceble LED fittings complete all as specified and directed.
Supply and fixing of PVC insulated Two core flexible copper cable 1.5 Sqmm FRLSH category type all as specified and directed
M&L for maintenance and servicing of DG Set of capacity 10 KVA to 75 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, top up coolant & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing rubber hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed by Engineer-in-Charge.
M&L for scraping the peeled oil Paint on DG set including alternator, engine and fuel tank, preparing the surfaces, cleaning the dust, dirt and applying the two coat of synthetic enamel paint of approved shade all as directed by Engineer-In-charge.
S & F in repair fuel pipe hand feed pump to fuel suitable for diesel engine, of following capacities and all as specified and directed by Engineer-In-Charge.
M&L for servicing of self starter 12/24 volts DC from DG set, dismantling complete and replacement of solonide field coil
M&L for in replacement, turbo kit of DG Set
Repairs of radiator assembly by dismantling from engine and removing the sediments and scales, corrosion etc by means of descaling chemical cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality material for stopping the leakage etc, re-assembling the same with new gaskets, fixing to the engine with hoses, clips complete to the entire satisfaction of engineer-in-charge
M&L for rewinding of alternator field coil with super enamelled copper winding wire insulated complete of suitable size of copper wire with 10-75 KVA DG set
M&L for rewinding and refixing of armature winding with super enamelled copper winding wire insulted complete of suitable size of copper wire with 10-75 KVA DG set
M&L for alternator bearing suitable for DG sets, all as specified and directed.
S&F in repair of engine start relay, 12/24 V DC for Gen Set 3 cranks on & off 0-30 sec each stable
M&L for repair/overhauling of self starter ic, replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc and warnishing complete all as directed of the following capacity:-(a) 12 Volts
-ditto- all as per item No.80 but 24 Volts
M&L for repair/overhauling of battery charging alternator 12/24 Volts, replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc and warnishing complete all as directed
Supply & fix Hose pipe set & Clips of water / coolant cooled radiator system etc all as specified and as directed
M&L for DG set control wiring of existing gauge with lugs and connecting accessories complete all as specified and directed
Repair & Maintenance of existing canopy of eco friendly DG Set of any capacity, cleaning of internal & external parts, tightening of loose parts, painting of rusted inside area, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations, Replacement/Welding of damaged MS hinges suitable for Canopy door etc complete all as specified and directed .
Dismantling the fly wheel coupling between engine and alternator and Supply and replace complete set of rubber bushes, coupling nuts & bolts including proper alignment of engine & alternator for smooth running for DG set of capacity complete all as specified and directed by Engineer-in-Charge
S&F in repair, PCB assy complete with display and update software including wring work suitable for DG Se of capacity 15 to 75 KVA.
M&L for servicing of alternator of any make suitable for DG set by opening the end cover, cleaning the dust and rust formed over the terminals, cleaning with CTC liquid, checking of diodes, winding, isolating transformer and AVR panel and applying Dr. beck paint for insulation improvement over the strips/ winding and drying till getting sasfactory insulation resistance complete, refixing the covers including testing complete all as specified and directed.
M&L in repair Flexible rubber coupling star type alongwith accessories suitable for Dg set of capacity 10 to 75 KVA
Supply and fix in repalacement of battery,12 V 180 AH including testing for its proper functioning as specified and directed by Engr-in-Charge. Make:-Exide,Amron,Luminuos Note :- Battery shall be original make accepted No substitute of battery.
Supply and fix in repalacement of battery,12 V 150 AH including testing for its proper functioning as specified and directed by Engr-in-Charge. Make:-Exide,Amron,Luminuos Note :- Battery shall be original make accepted No substitute of battery.
Supply and fix in repalacement of battery,12 V 80 AH including testing for its proper functioning as specified and directed by Engr-in-Charge. Make:-Exide,Amron,Luminuos Note :- Battery shall be original make accepted No substitute of battery.
M&L for dismantling of existing DG set by disconnecting LT outgoing cables, disconnecting of earthings, and complete acessories, Loading, unloading with the help of suitable crane/hydra shifting the same to Chandan location and vice versa as the case may be including providing transportation from one sub station to another substation or workshop (as directed) and fixing, connecting, commissioning and testing the DG Set at location as directed by making all arrangements at location and connecting the outgoing cables as required and connecting the earthings etc and making functional complete all as specified and directed by Engr-in-charge at site. Note :Any damage caused to the DG set during tranportation is off the contractor responsibility.
M&L for repair to water cooler by taking out existing unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat, vaccumising the system, gas charging and spray painting with one coat of synthetic enamel paint (smoke grey) and testing complete all as directed by Engineer-in-charge.
M&L for repair to refrigerator of make Kelvinator / LG / Godrej / Whirlpool /Samsung of capacity 165 ltr / 286 ltr / 300 ltr / 310 ltr by taking out old unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat and gas charging in system & testing complete and spray painting with one coat of synthetic enamel paint of approved shade/tint all as directed by Engineer-in-charge.
M&L for repair to Deep Freezer any make upto 500 ltr capacity by taking out old unserviceable compressor unit, replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat and gas charging in system with R-12/R-22/R-134a gas & testing complete and spray painting with one coat of synthetic enamel paint of approved shade/tint all as directed by Engineer-in-charge.
Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Litres including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking/ testing (if considered repairable on testing) then repair the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., checking/ testing (if considered repairable on testing) then repair and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed . Note :- 1. Replacement of defective spares as float valve, overload relay ,starting relay ,condenser fan blade & motor,capacitor ,waste water tray,drain out pipe,waste water adopter,pvc Connection,condeser coil etc. for making the water cooler units in satisfactory working condition , Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above.
S & F in replacement chromium plated push taps suitable for 40/80/120/150 Litre capacity water coolers all as directed.
M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, submersible pump, fan blade, front grill, wiring, capacitor, cleaning or any other repair work ,greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers as specified and re-fixing to existing place after repair work/overhauling preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers complete all as specified and directed. Note :- (i) The rates quoted by the contractor shall deemed to include the cost of T&P. (ii) The items required to be replaced shall be deemed to be included in unit rate quoted above.
Supply and fixing in repairs of desert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and as directed.
Disconnecting from mains and taking down for servicing of Refrigerator,cleaning of cooling coil, condenser with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed . Note :- 1. Replacement of defective spares as capilary tube, overload relay ,thermostate ,defrost tray,door gasket etc. for making the Refrigerator units in satisfactory working condition , Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above.
Disconnecting from mains and taking down for servicing of Deep freezer including detecting the leakage of gas and bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and topping of refrigerant up to the required level , cleaning of cooling coil, condenser, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed . Note :- 1. Replacement of defective spares as starting relay, overload relay ,thermostate ,capacitor ,Axial fan etc. for making the Deep freezer units in satisfactory working condition , Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above.
Supply and fixing 2 TR capacity split type Air Conditioner outdoor kit with latest refrigerant gas compatible including condenser coil with protection fins, blower motor and its fan blade, chassis & base plate with outdoor covering without compressor, suction and discharge valve, capillary tube of expansion valve, contactor with PCB card, capacitors and copper pipes & PVC wires of suitable size for internal connection, etc. complete all as specified & as directed.
Disconnecting from mains and taking out existing unserviceable resive sealed compressor unit , supply & fixing in replacement sealed compressor unit with latest refrigerant gas compatible, suitable for 2 TR window type AC/ Split AC of existing capacity and make complete including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc and commissioning complete all as specified & as directed.
Supply & fixing new indoor unit with remote control and with latest refrigerant gas compatible complete set suitable for 2 TR capacity complete all as specified & as directed. (Note for :- Outdoor and indoor unit of AC shall be compatible either with each other or existing units)
Supply and fixing in repairs 1.5 TR capacity window type AC kit (without compressor) including condenser coil & evaporator coil (copper), copper wounded blower motor, cooling coil, front grill blower motor, chassis, base plate, reverse valve, capacitors and copper pipes & PVC wires of suitable size for internal connection etc including taking down old one complete all as specified and as directed .
Disconnecting from mains and taking out existing unserviceable resive sealed compressor unit ( Model no:CR 22) and supply & fixing in replacement sealed compressor unit with latest refrigerant gas compatible, suitable for 1.5 TR window type AC/ Split AC of existing capacity and make complete including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc and commissioning complete all as specified & as directed.
Supply & fixing wall mounted digital Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed. Make: V-Guard model No-VND 500 or equivalent model of Bluebird, Emerson or any other Make mentioned in PS.
Shifting, installation, and re-commissioning of Split Air Conditioner (1.5/2.0 TR) from one location to another by completely dismantling the existing unit without any damage, shifting it to the new site, and reinstalling it, including gas charging to the required level, the work includes drilling holes by using core cutting into brick/stone walls for connecting indoor and outdoor unit pipes, cutting chases for concealed conduit wiring and water tubing, and making good the surfaces with cement mortar (1:3) at ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc., as required. Additionally, connecting indoor and outdoor units with copper pipes, installing drainage pipes, fixing the outdoor unit on a separately provided stand, carrying out temperature and gas pressure testing, and complete installation and commissioning are part of the scope. Necessary carpentry, plumbing, masonry work, and white cementing are also included complete all as specified and directed.. Note: Drain pipe, copper pipes of required size, refrigerant gas, outdoor stand, power plug, MCB, and copper wire will be paid under the relevant item.
Supply & fixing in replacement of Split / Window A/C air blower motor copper wounded for 1.5 TR & 2 TR capacity AC complete all as specified & as directed..(Make as per site requirement.)
Supply & fixing in replacement of copper wounded motor for outdoor of Split type AC of 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make as per site requirement.)
Supply & fixing in replacement heavy duty copper pipe 12mm (1/2") dia/ bore complete including brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed.
ditto- all as per item No. 114 above but copper pipe 6mm (1/4") dia/ bore.
ditto- all as per item No. 114 above but copper pipe 15mm (5/8") dia/ bore.
ditto- all as per item No. 114 above but copper pipe 10mm (3/8") dia/ bore.
Taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia with coupler Joint for Split/window AC complete all as specified & as directed.
M&L for Carryout the pressure test with nitrogen gas of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed.
M&L for complete topping up the refrigerant gas( R32/ R410A/R407) in split/window/Tower AC type 1.5/2 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
M&L for wiring from indoor unit to outdoor unit of size 2.50 sqmm PVC insulated multistranded FRLS four core round cable including fixing of thimbles for fixing in compressor terminals for split type Air Conditioner 1.5/2.0 TR capacity inclduing taking down old unserviceable complete all as specified and directed.
Taking down unserviceable insulation for copper pipe, supply and fixing new nityrile rubber insulation for copper pipes suitable for Split AC of capacity from 1.5 to 4.0 TR complete all as specified & as directed.
S&F in replacement remote control of existing make including battery for split/window /tower AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as specified & as directed
Supply & fixing in repair PCB, suitable for inverter/non-inverter type, split type AC/ window type AC of any capacity and model complete all as specified and as directed.
Supply, fixing, connecting and testing in repair energy efficient LED Post top light fittings made in die cast aluminium bottom and spun aluminium to reflector with decorative clear acylic diffuser and IP65 protection, with higher efficiency lighting of capacity not less than 25 Watt, range 140-280 volts with surge protection inbuilt in driver for maximised protections, driver should be potted type for viberation proof performancein and includings making electrical connections and taking down of old unserviceable light fitting of any type complete all as directed.
Supply and fixing in replacement of 25 watt, Non integral flexible LED strip light with high brightness professional for outdoor application, suitable to cut and joint for desired length, IP 65, Warm /cool white light complete all as specified and directed
Supply and fixing in replacement of 25 watt, Non integral flexible LED strip light with colour output suffron,white and green (tiranga colour with same sequence) professional for outdoor application, suitable to cut and joint for desired length, IP 65, complete all as specified and directed
Supply and fixing in replacement LED driver suitable for LED strip rope of capacity 25 watt, IP 65, suitable for outdoor application complete all as specified and directed
Supply and fixing in replacement aviation obstraction lights not less than 10 watt, 230 volts, 50 Hz comprising of aluminium housing with Polycarbonate enclosure, suitable for outdoor application complete all as specified and directed
Supply and fixing of decorative LED Wall / Spot Lights suitable for outdoor or indoor architectural lighting, made of powder-coated aluminum housing with integrated LED driver, ensuring glare-free and uniform illumination. All fixtures shall be IP65 weatherproof, suitable for 230V AC supply, and installed complete with all necessary accessories, wiring connections, and proper mounting/grouting arrangements as required for safe and efficient operation.Following types of fixtures shall be used complete all as specified and directed (a) Down Lighter Type – Power rating minimum 3W (Down light), emitting warm white light (3000K) directed downward only.
(b) Up–Down Lighter Type – Power rating minimum 6W (3W up + 3W down), emitting warm white light (3000K) both upward and downward.
(c) Adjustable LED Spot Light/Picture lights – Power rating 6W to 12W, with adjustable beam direction &rotating type, suitable for accent or façade highlighting, complete with heavy-duty mounting base and grouting in wall or floor as required.
Supply, fixing and connecting Pressure pump with motor of capacity 01 Hp, 220 volts suitable for boosting of water supply in bathrooms with automatic operation complete in and including taking down of unserviceable pressure pump all as specified and directed,
Supply, fixing and connecting Pressure pumpwith motor of capacity 0.5 Hp, 220 volts suitable for boosting of water supply in bathrooms with automatic operation complete in and including taking down of unserviceable pressure pump all as specified and directed,
Taking down old unserviceable sub main wiring and M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 2.50 Sq mm 1100 volts grade including and 2.50 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in PVC casing incl. Note : Two run of 2.50 Sqmm cable and one run of 2.50 Sqmm cable as earth continuity conductor and 25 mm PVC conduit shall be measured & paid as one unit.
Taking down old unserviceable sub main wiring and M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 4.00 Sq mm 1100 volts grade including and 4 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in PVC casing caping conduit incl. Note :- Two run of 4.00 Sqmm cable and one run of 4 Sqmm cable as earth continuity conductor and 25 mm PVC conduit shall be measured & paid as one unit.
Taking down old unserviceable sub main wiring and M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 6.00 Sq mm 1100 volts grade including and 6.00 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in PVC casing caping conduit incl Note : Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm cable as earth continuity conductor shall be measured & paid as one unit.
S&F Sheet Metal enclosure for VTPN DBs, 4 Ways, Double Door(IP-43), built- in bus bars complete suitable for 415 Volts, AC, 50 Hz supply, suitable for incoming MCCB and outgoing MCBs and fixed in recess in brick masonary wall complete all as specified and directed by the Engr-in-charge. Make - Legrand, C&S, Hevells
(a) S & F MCB, 6 to 32 Amp, SP, 240 Volt. complete all as specified and directed.
(b) S&F MCB 63 Amp, TPN 240 volts 10 KA, 'C' curve complete all as specified and directed.
M&L 4 Pole MCCB 63, 50 Hz, 415 V with rupturing capacity 16 KA.complete including connecting to MCB DB all as specified and directed. Make/brand: Havelle/ABB/Legrand
S & F MCB 6-40 Amp, single pole 240 Volt complete all as pecified & directed.
S&F weather proof lighting distribution Panel SPN 4 way, with incoming MCB 2P, 25 Amps-01 Nos, Outgoing MCB , 1 Pole, 6A to 10 Amps-02 Nos with complete with internal Bus Bar & wiring upto terminal complete all as directed
Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral including taking down complete all as directed by Engineer-in-Charge.
Supply, fixing and connecting elastomer insulated, round cable,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size 2.5sqmm, 4 core, confirming to IS 694-1990 complete all as specified and directed
Supply, fixing and connecting elastomer insulated, round cable,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size 4sqmm, 4 core, confirming to IS 694-1990 complete all as specified and directed
Supply, fixing and connecting elastomer insulated, round cable,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size 6sqmm, 4 core, confirming to IS 694-1990 complete all as specified and directed
(b) -ditto- all as per item No.148 above but Street light/Perimeter light pole
(c ) -ditto- all as per item No.148 above but Bollard light/building security lights
Supply only BIS registered potted driver with "R" number for LED street light fitting 45-150 watt. Make : Bajaj/Philips/Shakti/CG.
Supply only BIS registered potted driver with "R" number for LED bollard light 9-20 Wt. Make : Bajaj/Philips/Shakti/CG.
Supply surge protection device (SPD) for LED street light fitting 45-150 watt. Make : Bajaj/Philips/Shakti/CG.
Supply and fix SMC junction box with IP 55/IP 65 protection of size not less than 200 x 160 x 98 mm , 5 way having terminals for termination of cable with necessary nuts and bolts including -02 Nos cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete all as specified and directed at site
Material and Labour in repositioning/ realigning directional changes of Security lights affected by High speed wind / Desert Storm over the same existing poles in specific locations as directed by Engineer in Charge. Material consumed will be measured and paid Separately. Note: Skilled Labour, Tools as required will be provided by Contractor.
Supply and fix SMC junction box with IP 55/IP 65 protection of size not less than 350 x 250 x 140 mm , 5 way having terminals for termination of cable with necessary nuts and bolts including -02 Nos cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete all as specified and directed at site
Material and Labour in altering height of security light elevation over the same existing poles in specific locations as directed by Engineer in Charge. Note: Skilled Labour, Tools as required will be provided by Contractor.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable 10SQMM flat or circular. Make - Plaza/Polycab/ Finolex
S&F 20mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded olypropylene random fittings fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete all as specified and directed
Taking out existing PCC/steel tubular LT electric poles of any length including breaking of cement concrete, necessary excavation and earth work, dismantling cross arms, M.S. clamps, insulators etc and carefully taking down existing over head conductors.
Supply and erecting steel tubular poles complete with cast iron base plate finial taper plug , bolts Nuts & screws complete all as specified type 410SP 55 of 11 mtr long including painting of pole with one coat red oxide primer & two coat of aluminum paint & embeded portion shall be painted with two coat of black paint all as psecified in IS including the following:- (a) Excavation in post holes in any types of soil ,return filling , well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points.(b) PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundation up to ground level all as specified and directed .(c) PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in coping including necessary form work. (d) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work. (e) M&L for writing letters of figures ( Black, Roman, Itallicor Indian) with thick enamel paint of approved shade mn exc 5cm height in numbering of pole in and including dismantling of old unsv steel tubular poles complete all as specified and directed .
Supply and fixing in replacement , street/security light bracket made out of 40/32/25 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete.(Rates quoted by the contractor shall deemed to include for nut and bolts).
Supply, fixing and connecting elastomer insulated, flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed
Supply, fixing and connecting elastomer insulated, round or flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size 2.5sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed
S&F LED street light fitting 45 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete. Make : Havells/HPL/Bajaj/Shakti.
M&L for MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and directed by Engr in charge.
Checking/testing of Earth resistance value of earthing pits as requirement basis as directed by Engr in Charge or as schedule and , all as specified and directed by Engr-in-Charge. Note: (i) Testing and correction action is to be done within seven days from date of commencement .The contractor has to deploy electrician with helper and testing equipment and all the resources to complete the task within one month. (iii) Digital Earth tester will be arrange by the contractor his own. (iv) Recording of earth test results in register as per format given by Engr-in-charge and submitting the same to Engr-in-charge after test complete all as directed at site.
Supply and fixing in replacement of earth resistance marking plate fabricated from MS plate not less than 3mm thick, in square shape of size 200x200mm, fixed to equal angle of size 20x20x3mm of length 0.75 mtr, 0.30 mtr shall be embedded in PCC of 1:2:4, type B-1, using 15mm stone aggregate of size 200x200x300mm below ground level in and including necessary earth work duly writing of earthing No and details of earth, painted with applicable colour code for conventional/ chemical earthing complete all as specified and directed
Supply and fixing in repair of Galvanised iron earth electrode plate of size 600x600x6mm complete all as specified and directed at site.
S&F GI Funnel with wire mesh on existing 20 mm dia pipe for earthing complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair GI Pipe light grade, 20mm dia , galvanized, with all fittings complete all as specified and directed
Supply and fixing in repair GI Pipe light grade, 40mm dia , galvanized, with all fittings complete all as specified and directed
Supply and fixing in repair GI Pipe light grade, 50mm dia , galvanized, with all fittings complete all as specified and directed
M&L for taking down of copper earth strip of any size and kept aside for schedule of credit or refixing at site
M&L for refixing of serviceable copper earth strip of any size retrived from site on wall/ roof/ buried in ground through pipe/ on insulator complete all as specified and directed
M&L for copper strip 20 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
M&L for taking down of aluminium earth strip of any size and kept aside for schedule of credit or refixing at site
Refixing of serviceable aluminum strip of any size complete as obtain with on saddle / insulators, including straightning and fixing screws/accessories fo ron wall/ roof/ buried in ground complete all as specified and directed by Engr-in-Charge. Note: 1.Fixing of serviceable insulators will be deemed to be included with quotade rate. 2.New insulators will be measured and paid separetly
M&L in repair aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground comnplete all as specified and directed
M&L for taking down of GI earth strip of any size and kept aside for schedule of credit or refixing at site
M&L in repair galvanised iron (GI) strip 32mm x 6 mm buried in ground/ fixed on wall/ Passed through pipe/wall including connected by means of exothermic brazing, nuts and bolts where required complete all as specified and directed
Re-fixing of serviceable galvanised iron (GI) strip of any size complete as obtain with on saddle / insulators, including straightning and fixing screws/accessories for roof and down conductor complete all as specified and directed by Engr-in-Charge. Note: 1.Fixing of serviceable insulators will be deemed to be included with quotade rate. 2.New insulators will be measured and paid separetly
M&L for porceiline insulator suitable for fixing earthing strip to the wall / floor etc complete with necessary nuts, bolts and fixing material complete all as specified and as directed
Demolition of cement concrete (un-reinforced) of any description and any position n.exc 15 cm thickness (below or above GL) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles, making base for fixing of earth strip, Air termination rod on roof top, or indicated site , path to LT panels, bollard light(bollard lights to be refixed after repair to base) and other indicated work including necessary form work and finished the surface and including dismantling of old unseerviceable PCC complete all as specified and directed by Engr in charge.
Material and labour for providing cement concrete block size (Lxbxh) 30 x 30 x 30cm , 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for making base for fixing of earth strip, Air termination rod on roof top to be refixed after remove of old base) and other indicated work including necessary form work and finished the surface and including dismantling of old unserviceable PCC block complete all as specified and directed by Engr in charge.
M&L for Earthing pit of PCC 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar of inner size 300 x 300x 300 mm depth with wall thickness 120mm , watering arrangement with funnel and wire mesh complete all as specified and directed.
Dismantling of existing broken PCC earth chambers of any description and M&L providing earth chamber of size 300 mm x 300mm (Internal size),and depth 280mm and 75mm thick with PCC 1:3:6 type C1 using 20mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
M&L for cutting of bitumanous road or PCC upto 30cm deep and 20cm wide for laying of pipe lines for protection of GI strip and making good surface by PCC 1:2:4 type B-1,20mm grade complete all as specified and as directed by Engineer-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Material & Labour in rectification of LT cable, fault existing / as and when occurs with diagonising equipments as applicable, and by joining with suitable LT cable joint kit. Note:- (a) Diagonising equipments, Skilled labour, Machinaries for excavation and refilling earth work are to be provided / arranged by the contractor at his expenses. (b) If LT cable fault occurs in Road crossing then Road cut surface to be made good after rectification work. (c) GI pipe utilized fo cable protection under Road/ Over wall will be measured and paid separately.
Disconnecting and Taking out of old LT armoured PVC cables from trenches of any size/core/any voltage grade from trenches for replacement all as directed by Engr in charge
Supply, laying or fixing or passing through GI pipe, HDPE (DWC pipe) commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs including taking out /dismantling of existing cable. (a) 10 Sqmm 2 core Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
(b) -ditto- all as per item No.196 above but 10 Sqmm 4 core
(c) -ditto- all as per item No.196 above but 16 Sqmm 4 core
(d) -ditto- all as per item No.196 above but 25 Sqmm 4 core
(e) -ditto- all as per item No.196 above but 70 Sqmm 3.5 core
M&L for GI Tubes, of following size, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road for protection of LT cables or earth strips etc complete all as specified and as directed.(a) 40 mm bore
(b) -ditto- all as per item No.201 above but 50 mm bore
Drilling (Horizontally) existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80/100mm complete all as specified and directed.
Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation & getting out in for laying of cable complete as specified. (a) Soft/loose soil
(b) -ditto- all as per item No.204 above but Hard soil
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
M&L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
M&L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
M&L for tibba sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
M&L for 40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable complete including taking up of old protection material all as specified and directed.
Manisha Enterprises (BID ID -3483985)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
8380TenderDocuments.pdf
Tender Documents • 1.40 MB
BOQ_827141.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid