GEMC-511687720375506
Awarded to THE SERVICE POINT
₹1.6 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| PORTABLE X RAY MACHINE 100 MA | X RAY MACHINE | - | 1 NOS | ₹1.6 L | 159,800 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.6 LQualified Make: BPL
Model: X RAY MACHINE D 6 BDA DUPLEX NEAR RAILWAY TRACK ZONE 1 M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | Make: BPL
Model: X RAY MACHINE | L1 | Qualified | |
| 2 | Qualified Make: BPL
Model: X RAY MACHINE F 354 1ST FLOOR NARAYANI COMPLEX TRANSPORT NAGAR TRANSPORT NAGAR LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | Make: BPL
Model: X RAY MACHINE | - | Qualified | |
| 3 | L2₹2.7 L+₹1.2 L (72.1%)Disqualified Make: Medilux
Model: Medilux F 354 1ST FLOOR NARAYANI COMPLEX TRANSPORT NAGAR TRANSPORT NAGAR LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | Make: Medilux
Model: Medilux | L2 | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Sept 2018, 2:00 pmClosed
COMPUTED RADIOGRAPHY SYSTEM Experience with Gov. Required 3 Year (s) COMPUTED RADIOGRAPHY SYSTEM ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TYPE Type of computed radiography (CR) System Multi Loading Computed Radiography System (MLCRS) Single Loading computed radiography System (SLCRS)
Multi Loading Computed Radiography System (MLCRS) COMPATIBILITY CR System compatible with standard X-ray Machine consisting of Digitizer Patient Identification System
Preview And Processing Server with Workstation Yes * C R System to be supplied with compatible Cassettes & Imaging Plates for Recording Yes * ACCESSORIES FOR MULTI LOADING CR Imaging plate and Cassette 14x17
14x14
10x12
8x10sizes-Img.Plate & 14x17
8x10sizes-Img.Plate & 1/9 SYSTEM (dimensions in inch x inch) set offered with Multi loading computed radiography system Castt.-3 units each
8x1 0
10x12sizes- Img.Plate& Mammo.Castt-2 units each Castt.-3 units each
10x12sizes- Img.Plate& Mammo.Castt-2 units each
14x17
8x10sizes- Img.Plate & Castt.-6 units each
8x10
10x12 sizes-Img.Plate& Mammo.Castt-3 units each
8x10sizes- Img.Plate & Castt.-9 units each
10x12 sizes-Img.Plate& Mammo.Castt-4 units each
NA for Single loading CR System ACCESSORIES FOR SINGLEI LOADING CR SYSTEM Imaging plate and Cassette (dimensions in inch x inch) set offered with Single loading computed radiography system 14x17
sizes- Img.Plate & Castt.-3 units each 14x17
sizes- Img.Plate & Castt.-3 units each
sizes-Img.Plate & Castt.-6 units each
sizes- Img.Plate & Castt.- 9 units each
NA for Multi Loading CR System IMAGE READER For the largest Imaging plate/Cassette size
the Images Reading (CR Reader)/Digitizer is able to process >= 30 Imaging Plates/hour (for offered single loading computed radiography system) * CR Reader/Digitizer should have Pre-set Anatomical Processing facility
acquisition and Image transfer at a resolution 12 Bits/pixel Yes * CR Reader/Digitizer should have Status Display facility preferably on a LCD Display Indicating Error Status etc Yes * CR Reader/Digitizer should have Scanning Resolution of (5-10 Pixels/mm Or More) Yes * If multi loading computerised system
CR Reader/Digitizer to be supplied along with an Input and Output Yes * 2/9 Cassette Buffer/stacker for >=4 Cassettes each CR Reader/Digitizer should have a scanning resolution >= 5-10 Pixels/mm for General Cassette Reading for the offered single loading radiography system. * CENTRALISED PATIENT STUDY MANAGEMENT (CPSM) UNIT Processing Server And Workstation With 21 Inch LCD Monitor for Centralized Patient Study Management (CPSM) unit Yes * CPSM unit should have features: (i) Work Station must be able to receive CR Images From Digitizer (ii) DICOM Ready For Sent
Receive And Print Facility Protocol Yes * CPSM unit should have features: (iii) Possible To Multi-formatting The Images On Film For Printing (iv) 21 Inch LCD Monitor For Patient Study Management (v) Possible To Write Images On A CD/DVD Yes * CPSM unit should have features: (vi) Ready To Accept Images From Work List And Patient Data And Images Another RIS/HIS (DICOM PROTOCOL) (vii) Black Border Facility Yes * CPSM unit should have features: (viii) Software For Printing And To Create Various Film Layouts And Multiple Formats On Single Film For Optimum Utilization Of Film And Presentability Yes * CPSM unit should have The Capability To Customise User Defined No of Formats And Layouts On The Single Film Yes * 3/9 CPSM unit should have capability of Printing the Zoomed Image along with The Overview of the Main Image on same film Yes * CPSM unit should have capability of Printing Multiple Patient Images on one Film And Multiple Images of same Patient on One Film Yes * CPSM unit should have features: Image Gray Scale Reversal
Image Flipping And Rotating
Image Zooming Yes * CPSM unit should have features: Edge Enhancement
Latitude Reduction
Image Noise Reduction
Gray Scale Saturation Feedback Yes * CPSM unit should have provision For Adding Markers Yes * Patient Identification Preview (i) Separate Or Inbuilt Patient Identification System (ii) Cassette Identification And Demographics Should Be Standard (iii) It Should Be Possible To Identify The Multi X-ray Units Separately Yes * DRY IMAGER Dry Imager (For Film Printing) to be supplied with offered Single Multi loading CR System
should be with a Spatial Resolution >= 500 PPI/DPI
Contrast Resolution of >= 12 Bits/Pixel
Preferably with Standard Film Sorter at the Output for sorting the Films Bases On Modality Connected Access Time For First Film Should Be 90 Seconds Or Less The Yes * 4/9 Dry Imager should be DICOM Compatible for Receive Sent And Print Facility and it should allow (for multi loading CR System) at least Allow Three Sizes From the Five Sizes To Be Loaded at Any Time Printer Status Should Be Displayed For Any Error Status Etc Dry Imager should be with Preferably with Standard Film Sorter at the Output for sorting the Films Bases On Modality Connected Access Time For First Film Should Be <= 90 Seconds Yes * Dry Imager should be DICOM Compatible for Receive Sent And Print Facility
Printer status should Be Displayed For Any Error Status Etc Yes * Dry Imager should allow (for MLCRS) >= 3 sizes from the 5 Sizes to be loaded at any time Yes * Number of online sizes (at least) out of 8 x10
10x 12
14x 14
14x17 sizes
available in the Dry Imager 2 online sizes for offered single loading computed radiography system * For the largest size
Dry Imager (For Film Printing) have a normal through put (Films Per Hour) of at least of >= 30 for offered single loading computedradiography system * CONNECTIVITY & SCALABILITY Interconnectivity Between Various CR Modules Should Be Ethernet Based Yes * Scalability : The CR System Should Have Scope Of Adding Advanced Quality Software For Image Processor
Workstations Yes * 5/9 Connectivity To Any DICOM Archive Or Image Management Systems (PACS) ADVANCED QC VIEWER Advanced QC Viewer shall be with 19 Inch High Resolution Medical Grade Monitor for reviewing of the Images Yes * Advanced QC Viewer should be a separate Module For being able to be kept away From The Digitizer/CR Reader In the room of choice NA-Advance QC Viewer Not offered with CR System * Advanced QC Viewer should have features; (i) Window leveling
Annotation
Printing
Rotating
Flipping
Panning
Zooming All Image Post Processing NA-Advance QC Viewer Not offered with CR System * Advanced QC Viewer should have features; (ii) Should Have Hospital Information System (HIS) Connectivity (iii) There Should Be Provision For Adding Marker On The Film NA-Advance QC Viewer Not offered with CR System * Advanced QC Viewer should have features; (iv) It should be possible To Write Images On A CD/DVD: NA-Advance QC Viewer Not offered with CR System * POWER BACK UP The Entire Equipment Should Be Supplied With UPS of The Required Rating And Sufficient To Provide At Least 30 Minutes Back Up For The Whole System Yes * CERTIFICATION Should be US FDA/CE (European)/BIS approved product OEM should have ISO certificate for quality standard Yes
CE(European) approved * Copy of US FDA/CE YES * 6/9 (European)/BIS approval to be kept in Seller online locker and also made available to buyer on demand Please specify link to document in Seller Locker Availability Of Type Test Reports(TTRs) of The Product From Central Govt/NABL/ILAC Accredited Lab Showing Compliance To The Specification No * Test Report No NA * Test Report Date NA * Name Of The Labs NA * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Renu Pratap 462038
Raisen By Pass Road Karond Bhopal 1 15
544034
GEM/2018/B/77145
GeM Contract
COMPUTED RADIOGRAPHY SYSTEM
GeM Contract
15 days
Madhya Pradesh; Bhopal
PRODUCT
Awarded to THE SERVICE POINT
₹1.6 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| PORTABLE X RAY MACHINE 100 MA | X RAY MACHINE | - | 1 NOS | ₹1.6 L | 159,800 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| COMPUTED RADIOGRAPHY SYSTEM Experience with Gov. Required 3 Year (s) COMPUTED RADIOGRAPHY SYSTEM ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TYPE Type of computed radiography (CR) System Multi Loading Computed Radiography System (MLCRS) Single Loading computed radiography System (SLCRS) | - | - | - |
| Multi Loading Computed Radiography System (MLCRS) COMPATIBILITY CR System compatible with standard X-ray Machine consisting of Digitizer Patient Identification System | - | - | - |
| Preview And Processing Server with Workstation Yes * C R System to be supplied with compatible Cassettes & Imaging Plates for Recording Yes * ACCESSORIES FOR MULTI LOADING CR Imaging plate and Cassette 14x17 | - | - | - |
| 14x14 | - | - | - |
| 10x12 | - | - | - |
| 8x10sizes-Img.Plate & 14x17 | - | - | - |
| 8x10sizes-Img.Plate & 1/9 SYSTEM (dimensions in inch x inch) set offered with Multi loading computed radiography system Castt.-3 units each | - | - | - |
| 8x1 0 | - | - | - |
| 10x12sizes- Img.Plate& Mammo.Castt-2 units each Castt.-3 units each | - | - | - |
| 10x12sizes- Img.Plate& Mammo.Castt-2 units each | - | - | - |
| 14x17 | - | - | - |
| 8x10sizes- Img.Plate & Castt.-6 units each | - | - | - |
| 8x10 | - | - | - |
| 10x12 sizes-Img.Plate& Mammo.Castt-3 units each | - | - | - |
| 8x10sizes- Img.Plate & Castt.-9 units each | - | - | - |
| 10x12 sizes-Img.Plate& Mammo.Castt-4 units each | - | - | - |
| NA for Single loading CR System ACCESSORIES FOR SINGLEI LOADING CR SYSTEM Imaging plate and Cassette (dimensions in inch x inch) set offered with Single loading computed radiography system 14x17 | - | - | - |
| sizes- Img.Plate & Castt.-3 units each 14x17 | - | - | - |
| sizes- Img.Plate & Castt.-3 units each | - | - | - |
| sizes-Img.Plate & Castt.-6 units each | - | - | - |
| sizes- Img.Plate & Castt.- 9 units each | - | - | - |
| NA for Multi Loading CR System IMAGE READER For the largest Imaging plate/Cassette size | - | - | - |
| the Images Reading (CR Reader)/Digitizer is able to process >= 30 Imaging Plates/hour (for offered single loading computed radiography system) * CR Reader/Digitizer should have Pre-set Anatomical Processing facility | - | - | - |
| acquisition and Image transfer at a resolution 12 Bits/pixel Yes * CR Reader/Digitizer should have Status Display facility preferably on a LCD Display Indicating Error Status etc Yes * CR Reader/Digitizer should have Scanning Resolution of (5-10 Pixels/mm Or More) Yes * If multi loading computerised system | - | - | - |
| CR Reader/Digitizer to be supplied along with an Input and Output Yes * 2/9 Cassette Buffer/stacker for >=4 Cassettes each CR Reader/Digitizer should have a scanning resolution >= 5-10 Pixels/mm for General Cassette Reading for the offered single loading radiography system. * CENTRALISED PATIENT STUDY MANAGEMENT (CPSM) UNIT Processing Server And Workstation With 21 Inch LCD Monitor for Centralized Patient Study Management (CPSM) unit Yes * CPSM unit should have features: (i) Work Station must be able to receive CR Images From Digitizer (ii) DICOM Ready For Sent | - | - | - |
| Receive And Print Facility Protocol Yes * CPSM unit should have features: (iii) Possible To Multi-formatting The Images On Film For Printing (iv) 21 Inch LCD Monitor For Patient Study Management (v) Possible To Write Images On A CD/DVD Yes * CPSM unit should have features: (vi) Ready To Accept Images From Work List And Patient Data And Images Another RIS/HIS (DICOM PROTOCOL) (vii) Black Border Facility Yes * CPSM unit should have features: (viii) Software For Printing And To Create Various Film Layouts And Multiple Formats On Single Film For Optimum Utilization Of Film And Presentability Yes * CPSM unit should have The Capability To Customise User Defined No of Formats And Layouts On The Single Film Yes * 3/9 CPSM unit should have capability of Printing the Zoomed Image along with The Overview of the Main Image on same film Yes * CPSM unit should have capability of Printing Multiple Patient Images on one Film And Multiple Images of same Patient on One Film Yes * CPSM unit should have features: Image Gray Scale Reversal | - | - | - |
| Image Flipping And Rotating | - | - | - |
| Image Zooming Yes * CPSM unit should have features: Edge Enhancement | - | - | - |
| Latitude Reduction | - | - | - |
| Image Noise Reduction | - | - | - |
| Gray Scale Saturation Feedback Yes * CPSM unit should have provision For Adding Markers Yes * Patient Identification Preview (i) Separate Or Inbuilt Patient Identification System (ii) Cassette Identification And Demographics Should Be Standard (iii) It Should Be Possible To Identify The Multi X-ray Units Separately Yes * DRY IMAGER Dry Imager (For Film Printing) to be supplied with offered Single Multi loading CR System | - | - | - |
| should be with a Spatial Resolution >= 500 PPI/DPI | - | - | - |
| Contrast Resolution of >= 12 Bits/Pixel | - | - | - |
| Preferably with Standard Film Sorter at the Output for sorting the Films Bases On Modality Connected Access Time For First Film Should Be 90 Seconds Or Less The Yes * 4/9 Dry Imager should be DICOM Compatible for Receive Sent And Print Facility and it should allow (for multi loading CR System) at least Allow Three Sizes From the Five Sizes To Be Loaded at Any Time Printer Status Should Be Displayed For Any Error Status Etc Dry Imager should be with Preferably with Standard Film Sorter at the Output for sorting the Films Bases On Modality Connected Access Time For First Film Should Be <= 90 Seconds Yes * Dry Imager should be DICOM Compatible for Receive Sent And Print Facility | - | - | - |
| Printer status should Be Displayed For Any Error Status Etc Yes * Dry Imager should allow (for MLCRS) >= 3 sizes from the 5 Sizes to be loaded at any time Yes * Number of online sizes (at least) out of 8 x10 | - | - | - |
| 10x 12 | - | - | - |
| 14x 14 | - | - | - |
| 14x17 sizes | - | - | - |
| available in the Dry Imager 2 online sizes for offered single loading computed radiography system * For the largest size | - | - | - |
| Dry Imager (For Film Printing) have a normal through put (Films Per Hour) of at least of >= 30 for offered single loading computedradiography system * CONNECTIVITY & SCALABILITY Interconnectivity Between Various CR Modules Should Be Ethernet Based Yes * Scalability : The CR System Should Have Scope Of Adding Advanced Quality Software For Image Processor | - | - | - |
| Workstations Yes * 5/9 Connectivity To Any DICOM Archive Or Image Management Systems (PACS) ADVANCED QC VIEWER Advanced QC Viewer shall be with 19 Inch High Resolution Medical Grade Monitor for reviewing of the Images Yes * Advanced QC Viewer should be a separate Module For being able to be kept away From The Digitizer/CR Reader In the room of choice NA-Advance QC Viewer Not offered with CR System * Advanced QC Viewer should have features; (i) Window leveling | - | - | - |
| Annotation | - | - | - |
| Printing | - | - | - |
| Rotating | - | - | - |
| Flipping | - | - | - |
| Panning | - | - | - |
| Zooming All Image Post Processing NA-Advance QC Viewer Not offered with CR System * Advanced QC Viewer should have features; (ii) Should Have Hospital Information System (HIS) Connectivity (iii) There Should Be Provision For Adding Marker On The Film NA-Advance QC Viewer Not offered with CR System * Advanced QC Viewer should have features; (iv) It should be possible To Write Images On A CD/DVD: NA-Advance QC Viewer Not offered with CR System * POWER BACK UP The Entire Equipment Should Be Supplied With UPS of The Required Rating And Sufficient To Provide At Least 30 Minutes Back Up For The Whole System Yes * CERTIFICATION Should be US FDA/CE (European)/BIS approved product OEM should have ISO certificate for quality standard Yes | - | - | - |
| CE(European) approved * Copy of US FDA/CE YES * 6/9 (European)/BIS approval to be kept in Seller online locker and also made available to buyer on demand Please specify link to document in Seller Locker Availability Of Type Test Reports(TTRs) of The Product From Central Govt/NABL/ILAC Accredited Lab Showing Compliance To The Specification No * Test Report No NA * Test Report Date NA * Name Of The Labs NA * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Renu Pratap 462038 | - | - | - |
| Raisen By Pass Road Karond Bhopal 1 15 | - | - | - |
Exempted
13 Oct 2018
6 Sept 2018
contract_GEMC-511687720375506.pdf
GEM_CONTRACT • 0.03 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_544034.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .