| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC ASHIRBAD APARTMENT GANDHI S HOUSE RAMKRISHNA ROAD ASHRAMPARA SILIGURI 01 | ₹43.4 L Quoted ₹44.6 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹46.9 LRejected-Finance HAKIMPARA NEAR PAKURTALA MORE SILIGURI 734 001 HQ 136 WE | JALPAIGURI | WEST BENGAL | 734001 | ₹46.9 L | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹47.2 LRejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | ₹47.2 L | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹47.2 LRejected-Finance KHAPRAIL BAZAR PO NEW CHAMTA DIST DARJEELING WEST BENGAL PIN 734 009 | DARJEELING | WEST BENGAL | 734009 | ₹47.2 L | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | L5₹47.3 LRejected-Finance MILITARY ROAD OPP RHYTHM SHIVMANDIR PO KADAMTALA DARJEELING 734 011 | DARJEELING | WEST BENGAL | 734011 | ₹47.3 L | L5 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | ELECTRO WIR WAY L6 | MS ORIENT ENGINEERING WORKS L3 | SHRI N.DAS L2 | Janata Enterprises L9 | G C DUTTA N CO L5 | R N De L1 | PAUL CONSTRUCTION L7 | M/S. KARMAKAR ENGINEERING COMPANY L8 | D K SARKAR L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and installation of advance encapsulated compound based CPRI tested maintenance free,pipe-in-pipe technology upgrade (zinc & alloy coated),zinc coated (80-100) microns with pure zinc (99.9%) & alloy coating (200-250) microns and this system confirming to IS 3034.The outer and inner pipe of model ASEEL 19 should be 48.3 mm & 26.4 mm dia,3 mtrs length ,zinc coated with additional special alloy coating 300 mm on the topside for additional protection of the terminal.The annular space between the pipes being filled up with compact crystalline conductive compound.The compact fill (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes.The inner pipe should be extended with terminals for connectivity the job includes digging the pits and refilling the same by Electrodite back fill compound (ground enhancer),the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS certification from NAB accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals.In areas where soil condition is bad ,good earth is to be arranged to fill the excavated pits by mixing the same with BFC 2 or 4 bags (as per soil condition) extra per pit/unit.As the earth electrode is the main component of the earthing system which is in direct contact with the ground and thus provides a means of releasing or collecting earth leakage currents.The material should have good electrical conductivity & anti corrosion property in wide range of soil conditions.(All the above given dimensions may vary +/- 1 mm) .Make :- ASHLOK MODEL-ASEEL-19,3 mtr length (ZC & AC) or equivalent | 10 | Each Job | 42,000 ₹4.2 L | 32,000 ₹3.2 L | 31,257 ₹3.1 L | 31,000 ₹3.1 L | 31,636 ₹3.2 L | 28,500 ₹2.9 L | 31,900 ₹3.2 L | 31,500 ₹3.1 L | 29,500 ₹3.0 L |
| 2.00 | M&L in replacements for Earthing complete with copper earth plate electrode 60cm x 60cmx 3.15 mm thick electrode buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the earth plate not less than 1.5 meter below normal ground level connected to copper strip 20 x 3 mm as earthing lead by means of bolt and nut, check nuts and washers of brass material all as shown in electrical plate No 3 of MES Schedule part I with and including excavation & earth work in any type of soil, providing charcoal dust and common salt upto 15 cm above top edge of earth plate, construction of PCC pit in cement concrete 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 reinforced with 8 mm dia MS deformed bars @ 100mm center to center both ways watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 40mm dia medium grade pipe for earth lead protection and testing on completion complete all as specified and directed. | 10 | Each Set | 36,000 ₹3.6 L | 26,000 ₹2.6 L | 25,752 ₹2.6 L | 25,000 ₹2.5 L | 25,513 ₹2.6 L | 26,200 ₹2.6 L | 25,600 ₹2.6 L | 25,500 ₹2.5 L | 27,500 ₹2.8 L |
| 3.00 | Supply and fixing in repairs of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw with copper busbar mounted on porcelain insulators inside the terminal box for connection to copper strip incl necessary brass type nuts/bolts/washers complete all as specified and as directed. | 20 | Each | 1,500 ₹30,000 | 632 ₹12,640 | 618 ₹12,360 | 630 ₹12,600 | 643 ₹12,860 | 445 ₹8,900 | 750 ₹15,000 | 700 ₹14,000 | 600 ₹12,000 |
| 4.00 | Supply & fixing in repairs of copper strip 20x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified & directed. | 50 | RM | 1,100 ₹55,000 | 1,452 ₹72,600 | 1,442 ₹72,100 | 1,450 ₹72,500 | 1,480 ₹74,000 | 390 ₹19,500 | 1,600 ₹80,000 | 1,500 ₹75,000 | 1,400 ₹70,000 |
| 5.00 | Supply and fixing earthing continuty conductor or main earthing lead fixed to pole or burried in ground or at any other situation for loop earthing extra as required of GI wire 4 sqmm complete all as specified & directed. | 150 | RM | 30 ₹4,500 | 75 ₹11,250 | 72 ₹10,800 | 70 ₹10,500 | 71 ₹10,650 | 21 ₹3,150 | 75 ₹11,250 | 80 ₹12,000 | 68 ₹10,200 |
| 6.00 | Supply and fixing earthing continuty conductor or main earthing lead fixed to pole or burried in ground or at any other situation for loop earthing extra as required of GI strip 25x4 mm complete all as specified & directed. | 40 | RM | 90 ₹3,600 | 210 ₹8,400 | 207 ₹8,280 | 210 ₹8,400 | 214 ₹8,560 | 145 ₹5,800 | 200 ₹8,000 | 230 ₹9,200 | 202 ₹8,080 |
| 7.00 | Supply and fixing in repairs of glow sign board printed on flex sheet , size of board not less than 2.0 mtr X 1.0 X 0.20 mtr with contents written as details of power house in and the size of the letter not less than 20mm height , on 6mm thick polysheet on front and GI sheet backing on rear, sides, top and bottom including fabrication with necessary clamps and necessary arrangement including providing 10 nos 20 watt LED tubes with necessary wiring with copper wire, duly fixed on GI pipe of 40 mm dia (04 legs) with PCC for fixing on ground complete all as specified & directed. | 5 | Each Job | 7,000 ₹35,000 | 23,600 ₹1.2 L | 23,145 ₹1.2 L | 23,500 ₹1.2 L | 23,982 ₹1.2 L | 14,500 ₹72,500 | 25,000 ₹1.3 L | 24,000 ₹1.2 L | 24,200 ₹1.2 L |
| 8.00 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / loose soil complete all as specified and directed. | 140 | Cum | 160 ₹22,400 | 126 ₹17,640 | 133 ₹18,620 | 125 ₹17,500 | 128 ₹17,920 | 125 ₹17,500 | 180 ₹25,200 | 130 ₹18,200 | 120 ₹16,800 |
| 9.00 | Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed. | 50 | Cum | 130 ₹6,500 | 310 ₹15,500 | 307 ₹15,350 | 300 ₹15,000 | 306 ₹15,300 | 95 ₹4,750 | 140 ₹7,000 | 320 ₹16,000 | 289 ₹14,450 |
| 10.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. | 80 | Cum | 100 ₹8,000 | 160 ₹12,800 | 157 ₹12,560 | 150 ₹12,000 | 153 ₹12,240 | 95 ₹7,600 | 100 ₹8,000 | 180 ₹14,400 | 141 ₹11,280 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Mar 2026, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist-Darjeeling, WB-734009
REPAIR AND REPLACEMENT OF PVC BUSBAR TRUNKING SYSTEM INCLUDING TRUNKING ACCESSORIES AND CONNECTED ITEMS LIKE MCCBS DISTRIBUTION BOARDS, LT FEEDER PILLAR BOX, LT PANELS, CHANGEOVER SWITCHES AND CONNECTED ALLIED WORKS AT CAMP AREA AND OTHER CERTAIN LO
2026_MES_755122_1
GE Sukna/9017
Open Tender
Civil Works
180 days
SUKNA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SUKNA
₹80,000
27 Apr 2026
3 Mar 2026
28 Mar 2026
4 Mar 2026
26 Mar 2026
19 Mar 2026
4 Mar 2026 - 26 Mar 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GARRISON ENGINEER SUKNA
Name of Work : REPAIR AND REPLACEMENT OF PVC / BUSBAR TRUNKING SYSTEM INCLUDING TRUNKING ACCESSORIES AND CONNECTED ITEMS LIKE MCCB'S, DISTRIBUTION BOARDS, LT FEEDER PILLAR BOX, LT PANELS, CHANGEOVER SWITCHES AND CONNECTED ALLIED WORKS AT CAMP AREA AND OTHER CERTAIN LOCATIONS UNDER AGE E/M OF GE SUKNA AT MIL STN
Contract No: GE/SUK/ OF 2025-26
Supply and installation of advance encapsulated compound based CPRI tested maintenance free,pipe-in-pipe technology upgrade (zinc & alloy coated),zinc coated (80-100) microns with pure zinc (99.9%) & alloy coating (200-250) microns and this system confirming to IS 3034.The outer and inner pipe of model ASEEL 19 should be 48.3 mm & 26.4 mm dia,3 mtrs length ,zinc coated with additional special alloy coating 300 mm on the topside for additional protection of the terminal.The annular space between the pipes being filled up with compact crystalline conductive compound.The compact fill (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes.The inner pipe should be extended with terminals for connectivity the job includes digging the pits and refilling the same by Electrodite back fill compound (ground enhancer),the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS certification from NAB accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals.In areas where soil condition is bad ,good earth is to be arranged to fill the excavated pits by mixing the same with BFC 2 or 4 bags (as per soil condition) extra per pit/unit.As the earth electrode is the main component of the earthing system which is in direct contact with the ground and thus provides a means of releasing or collecting earth leakage currents.The material should have good electrical conductivity & anti corrosion property in wide range of soil conditions.(All the above given dimensions may vary +/- 1 mm) .Make :- ASHLOK MODEL-ASEEL-19,3 mtr length (ZC & AC) or equivalent Each Job Excess(+) Full Conversion INR
M&L in replacements for Earthing complete with copper earth plate electrode 60cm x 60cmx 3.15 mm thick electrode buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the earth plate not less than 1.5 meter below normal ground level connected to copper strip 20 x 3 mm as earthing lead by means of bolt and nut, check nuts and washers of brass material all as shown in electrical plate No 3 of MES Schedule part I with and including excavation & earth work in any type of soil, providing charcoal dust and common salt upto 15 cm above top edge of earth plate, construction of PCC pit in cement concrete 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 reinforced with 8 mm dia MS deformed bars @ 100mm center to center both ways watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 40mm dia medium grade pipe for earth lead protection and testing on completion complete all as specified and directed. Each Set Excess(+) Full Conversion INR
Supply and fixing in repairs of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw with copper busbar mounted on porcelain insulators inside the terminal box for connection to copper strip incl necessary brass type nuts/bolts/washers complete all as specified and as directed. Each Excess(+) Full Conversion INR
Supply & fixing in repairs of copper strip 20x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified & directed. RM Excess(+) Full Conversion INR
Supply and fixing earthing continuty conductor or main earthing lead fixed to pole or burried in ground or at any other situation for loop earthing extra as required of GI wire 4 sqmm complete all as specified & directed. RM Excess(+) Full Conversion INR
Supply and fixing earthing continuty conductor or main earthing lead fixed to pole or burried in ground or at any other situation for loop earthing extra as required of GI strip 25x4 mm complete all as specified & directed. RM Excess(+) Full Conversion INR
Supply and fixing in repairs of glow sign board printed on flex sheet , size of board not less than 2.0 mtr X 1.0 X 0.20 mtr with contents written as details of power house in and the size of the letter not less than 20mm height , on 6mm thick polysheet on front and GI sheet backing on rear, sides, top and bottom including fabrication with necessary clamps and necessary arrangement including providing 10 nos 20 watt LED tubes with necessary wiring with copper wire, duly fixed on GI pipe of 40 mm dia (04 legs) with PCC for fixing on ground complete all as specified & directed. Each Job Excess(+) Full Conversion INR
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / loose soil complete all as specified and directed. Cum Excess(+) Full Conversion INR
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed. Cum Excess(+) Full Conversion INR
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. Cum Excess(+) Full Conversion INR
M&L for sand cushioning to under ground cable using locally available fine clean dry river sand over,under ground UG cable laid in treches and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. Note : For the purpose of payment only punned thickness will be measured. Cum Excess(+) Full Conversion INR
M&L for brick protection cover of size 230x115x75 mm to LT underground cables with sub class 'B' over burnt brick, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed. Per 1000 Nos Excess(+) Full Conversion INR
Supply and fixing in repairs of GI tubing light grade 40mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall complete all as specified and directed . RM Excess(+) Full Conversion INR
Supply and fixing in repairs of GI tubing light grade 80mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall complete all as specified and directed . RM Excess(+) Full Conversion INR
Boring/Drilling (horizontally) manually under min 0.5 to 2 m deep in soil below existing road suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty), aluminium stranded conductor 1100 volts grade, laid through duct/ pipe / in trench etc.connected to LT panel/poles with cable glands & lugs including taking down old unsv cable from trennches/ducts/floors/poles complete all as specified and directed of following sizes:- (Note: Excavation and earth work will be measured & paid separately)
25 sqmm 4 core RM Excess(+) Full Conversion INR
50 sqmm 3 1/2 core RM Excess(+) Full Conversion INR
95 sqmm 3 1/2 core RM Excess(+) Full Conversion INR
Supply, laying connecting and testing of XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty), aluminium stranded conductor of 10 sqmm 4 core 1100 volts grade (for electric supply to LED garden Lights & Bollards) laid through in the ground by excavating the trench at the depth of min 30 cm & returning filling of soil including taking down old unsv cable from trennches/ducts/floors/poles complete all as specified and directed. (Note: Excavation and earth work shall be deemed to be included in the quoted rates) RM Excess(+) Full Conversion INR
Dismantling of insulator of any size/type and setting aside the serviceable insulator for reuse at site and removing unserviceable insulators from site of work complete all as directed. Each Excess(+) Full Conversion INR
Supply & fix insulator pin type porcelain , vitreous , white ,brown or green 150 mm height and 150 mm dia including one galvanised mild steel spindle , two galvanised washers and one galvanised iron nuts for conductor working pressure 11000 Volts grade complete all as specified and directed. Each Excess(+) Full Conversion INR
Supply & fix single disc assembly insulator for tension with tension clamps to the conductors porcelain type , vitreous , white ,brown or green 145 mm height and 255 mm dia ball and socket type, working pressure 11000 Volts grade complete all as specified and directed. Each Excess(+) Full Conversion INR
Opening the binding wire from pin / shackle/Disc insulator on HT/LT pole for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the Pin/Shackle/Disc insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- Charge. Note-: (i) The above work includes clearing/ prooning of tree branches falling around the conductors.(ii) Cost of binding wire deemed to be included in the quoted rate ,No extra amount will be paid. RM Excess(+) Full Conversion INR
M&L of aluminium conductor steel reinforced (ACSR) on pole ,stringing properly on insulators and binding with aluminium binding wire , jumpers etc complete for any size ( Mink , Dog ,Ferret ,Weasel ,Squirel of conductor complete all as specified and directed. Note : - Measurement & Payment shall be made by measuring horizontal distance between centre of two adjaacent pole and adding 3% extra for sag , joints and jumper etc . Per Qtl Excess(+) Full Conversion INR
Supply & fix insulator pin type porcelain , vitreous , white ,brown or green 100 mm height and 65 mm dia including one galvanised mild steel spindle , two galvanised washers and one galvanised iron nuts for conductor working pressure 1100 Volts grade complete all as specified and directed. Each Excess(+) Full Conversion INR
Supply & fix insulator shackle type porcelain , vitreous , white ,brown or green 75 mm height and 90 mm dia including galvanised mild steel straps os size 31mm x 3mm, washers,insulator bolts, washers and nuts complete for conductor working pressure 1100 Volts grade complete as specified and directed. Each Excess(+) Full Conversion INR
M&L for painting steel tubular poles 11 mtr height with one coat of aluminium paint from bottom to top including cross arms,GI brackets etc after cleaning and preparing the surface and marking alternate red and black strips 30 cm height total 5 Nos with two coats of synthetic enamel point over a coat of primer incl writing Pole No with black paint complete all as specified and as directed. Each Job Excess(+) Full Conversion INR
M & L for Painting of HT 2-pole structure complete with cross arms,channels, clamps,nut bolts of any length and shape for HT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia RED circle with yellow colour numbering with synthetic enamelled paint and strip marking of THREE RED AND THREE BLACK alternatively of width 15 cm by fluorescent paint, from bottom of pole to 90 CM height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed. Each Job Excess(+) Full Conversion INR
M & L for Painting of HT 4 -pole structure complete with cross arms,channels, clamps,nut bolts of any length and shape for HT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia RED circle with yellow colour numbering with synthetic enamelled paint and strip marking of THREE RED AND THREE BLACK alternatively of width 15 cm by fluorescent paint, from bottom of pole to 90 CM height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed. Each Job Excess(+) Full Conversion INR
M & L in repair for PCC earth pit chamber of internal dimension 300x300x300 mm and having wall thickness 100 mm using PCC 1:2:4 type B1 alongwith RCC 1:2:4 type B1 precast cover 50mm thick reinforced with 8 mm TMT bars both way & 100mm C/C including one lifting handle and dismantling of old one complete all as specified and directed. Each Job Excess(+) Full Conversion INR
Testing of earth resistance of transformer installations after disconnecting from body / neutral of the transformer and from the lightening arresters / HT / LT panels / 2 pole / 4pole structures and the earth continuity of OH earth wire including writing the results in the existing earthing after removing the existing letters by applying one coat of black paint complete all as specified and directed. Note :- (a) Test results obtained shall be recorded and produced to the Engr-in-Charge and the same will be marked on earth pit indicator/earth pit cover.(b) Measuring equipments and T&P required shall be arranged by the contractor.(c) Writing of letters shall be carried out by engaging highly skilled artist. Each Job Excess(+) Full Conversion INR
M & L for cleaning , scraping out old rubbed paint / rust & Painting of transformer complete of capacity up to 63 to 250 KVA 11/.433 KV outdoor / Indoor type with one coat of spray painting with synthetic enamelled gray paint (first grade) by sprey painting machine on transformer & Making SM NO on surface of transformer complete all as specified and directed. Each Excess(+) Full Conversion INR
M & L for cleaning , scraping out old rubbed paint / rust & Painting of transformer complete of capacity up to 300 to 500 KVA 11/.433 KV outdoor / Indoor type with one coat of spray painting with synthetic enamelled gray paint (first grade) by sprey painting machine on transformer & Making SM NO on surface of transformer complete all as specified and directed. Each Excess(+) Full Conversion INR
Supply and fixing in repair Switch air break, gang operated triple pole mechanically operated mounted on with 9 insulator and steel frame with operating mechanism working from ground level current rating upto 400A, 11000 V grade having nine insulators, vertical type including dismantling of existing air break gang operated switch and removal the same from site complete all as specified and directed. Each Set Excess(+) Full Conversion INR
Supply and fixing in repair expulsion drop out fuse carrier assembly outdoor type 400 Amps capacity including fuse element up to 60 Amps and insulator suitable for HT 11 KV complete and dismantling of existing fuse carrier assembly and removal the same from site all as specified and as directed. Each Excess(+) Full Conversion INR
S&F in repair MCCB,200 Amps 36kA, four pole, 415 volt adjustable overload setting 0.8-1.0 x In and adjustable thermal & Magnetic release all as specified and directed by Engineer-in- Charge. Each Excess(+) Full Conversion INR
S&F in repair MCCB,250 Amps 36kA, four pole, 415 volt adjustable overload setting 0.8-1.0 x In and adjustable thermal & Magnetic release all as specified and directed by Engineer-in- Charge. Each Excess(+) Full Conversion INR
S&F in repair MCCB,400 Amps 36kA, four pole, 415 volt adjustable overload setting 0.8-1.0 x In and adjustable thermal & Magnetic release all as specified and directed by Engineer-in- Charge. Each Excess(+) Full Conversion INR
Supply & fixing Aluminium lugs suitable for UG cable of size 3.5/4 core, 50 to 95 sqmm and making connection to MCCB/MCB including respective size of lugs for the neutral cable complete all as specified and as directed. Each Excess(+) Full Conversion INR
Supply & fixing Aluminium lugs suitable for UG cable of size 3.5/4 core, 120 to 240 sqmm and making connection to MCCB/MCB including respective size of lugs for the neutral cable complete all as specified and as directed. Each Excess(+) Full Conversion INR
M&L in repairs for jumper connection between OH line to GOD and GOD to drop out fuses with ACSR conductor 6/1X3.35 mm (rabbit) not exe. 2 mtr long including necessary lugs where ever required/aluminum heavy duty PG clamps contact all as directed after removing the old jumpers including PVC sleeve not more than 1.70 Rm complete all as specified and directed. Each Excess(+) Full Conversion INR
M&L in replacements for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 5 of MES Schedule part I with and including excavation & earth work in any type of soil, providing charcoal dust and common salt upto 15 cm above top edge of earth plate, construction of PCC pit in cement concrete 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 reinforced with 8 mm dia MS deformed bars @ 100mm center to center both ways watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed. Each Set Excess(+) Full Conversion INR
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized iron wire 4 mm dia as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 5 of MES Schedule part I with and including excavation & earth work in any type of soil, providing charcoal dust and common salt upto 15 cm above top edge of earth plate, construction of PCC pit in cement concrete 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 reinforced with 8 mm dia MS deformed bars @ 100mm center to center both ways watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed. Each Set Excess(+) Full Conversion INR
Supply and fixing in repair of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm incl taking down old unsv complete all as specified and as directed. Each Excess(+) Full Conversion INR
S&F for 32 mm dia GI tubing light grade bracket over all 1.2 mtr length bent to shape 120 degree with cutting as required and bend to shape with flat iron clamp of size 32x6 mm, 2 Nos, suitable size of nut bolts and washers complete for fixing street light fittings on electric poles/bldgs for security complete including taking down old unsv complete all as specified and directed. Make :- Nezone/Surya/Jindal poles/Bansal Each Job Excess(+) Full Conversion INR
S & F in repair of Pole mounted Junction box with terminals of size 210 x 260 x 117 mm ,made of high quality thermoplastic polycarbonate, dust & jet water proof, chemical, acid corrision, impact IK-09, insulated & shock proof IP 66, grey RAL 7035 color with internaly embedded gasket (PUR) , along with cover and metric knockout all sides including back of the base must including terminals 4Nos including fixing arrangement with MS flat of size 40X4mm , nuts , bolt and washers and MCB SP 6-32 Amps 01 No including taking down old unsv complete all as specified and as directed. Make : Hensel Cat Part No CJB008PS/ Sintex /Emitter Each Excess(+) Full Conversion INR
M&L for Weather proof flat three core PVC insulated and PVC sheathed industrial round 3 core PVC sheathed copper cable of size 2.5 Sqmm 1100 volts grade for connection of lights to Pole Box, after dismantling old one complete as specified and directed. RM Excess(+) Full Conversion INR
Supply and fixing of GI tubing light grade 15mm dia fixing to pole from JB to security light complete incl fixing arrangement to pole with the help of 03 pairs of clamps and nut bolts complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply and fixing in repair of LED street light luminaire 60 Watt (System Lumen output should not be less than 7200 Lumen) Energy saving and environmental friendly long life made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP-66 protection and Impact resistance of IK07 with 10 KV Built-in Surge Protection device with high performance LEDs,System Lumen Efficacy- > 120 Lm/Watt,power factor >=0.95, polyester powder coated with toughened glass having IP-66 protection, tempered protective polycarbonate diffuser, integrated high efficiency electronic driver with lower THD ,Colour Temp (CCT)- 6500 K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including LEDs with certification LM 79 for luiminare, LM 80 for LED source including all necessary internally pre-wired and connecting up incl taking down old unsv fittings from bracket of pole with repair/replacement warranty of 5 years of OEM complete all as specified and as directed. Make :- Philips/Crompton/Surya/Havells Each Excess(+) Full Conversion INR
Supply and fixing in repair of 3-phase Main Switch in sheet steel enclosure type FN (TPN) S-D-F of rated current 160 Amps including DIN type fuse links type HN incl taking down old unsv complete all as specified & as directed. Make :- L&T FN 160 TPN/Legrand/Havells Each Excess(+) Full Conversion INR
All as per Sl. item No. 48.00 above but for of rated current 200 Amps complete all as specified and directed. Make :- L&T FN 200 TPN/Legrand/Havells Each Excess(+) Full Conversion INR
All as per Sl. item No. 48.00 above but for of rated current 100 Amps complete all as specified and directed. Make :- L&T FN 100 TPN/Legrand/Havells Each Excess(+) Full Conversion INR
Supply and fixing in repair of busbar chamber 4 way of current rating 200 Amps, wall mounted made of ETP grade copper incl cable connection with suitable aluminum lugs & glands complete all as specified & as directed. Make :- Havells Cat No IHBC020004/Legrand/ABB Each Excess(+) Full Conversion INR
All as per Sl. item No. 51.00 above but for 4 way of current rating 400 Amps. complete all as specified and directed. Make :- Havells Cat No IHBC040004/Legrand/ABB Each Excess(+) Full Conversion INR
Supply, installation, testing and commissioning of Panel board not less than 1.70m x 1.70 m x 0.50 m , outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 400 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :- Each Excess(+) Full Conversion INR
INCOMING :- Aluminium busbar 400 Amps rated capacity-04 Nos. 250A 4P 36KA MCCB with O/L, S/C Thermal Mag Release-02 Nos MCCB Extended Rotary Handle-02 Nos Spreader Link-02 Nos MCCB Aux+Trip Unit-01 No Chang over switch 250A 4P-01 No C T Coil 250/5-03 Nos R,Y,B,On,Off,Trip indicator lamps LED-06 Nos Digital Ammeter inbuilt selector switch (M1V3)-01 No Digital Voltmeter inbuilt selector switch(M1A3)-01 No Fuse/ MCB 6A SP for meter Protection-03 Nos OUTGOING :- 200A 4P 36KA MCCB with O/L, S/C Thermal Mag Release-01 Nos MCCB Extended Rotary Handle-01 No Spreader Link-01 No 100A 4P 25KA MCCB with O/L, S/C Thermal Mag Release-02 Nos MCCB Extended Rotary Handle-02 Nos Spreader Link-02 Nos 63A 4P 25KA MCCB with O/L, S/C Thermal Mag Release-06 Nos MCCB Extended Rotary Handle-06 Nos Spreader Link-06 Nos MCB 63A 4P 10KA-02 Nos Terminal 63A 4P-02 Nos Danger Notice plate - 02 No. Panel control wiring complete with suitable size copper wire - 01Job.
Supply and fixing in repair of Ultra Heavy duty capacitor box oil filled type of capacity 10 KVAr, 440 volt 3 phase incl making connection to existing MCCB/Contactors incl taking down old unsv complete all as specified & as diretced. Each Excess(+) Full Conversion INR
Supply and fixing in repair of Ultra Heavy duty capacitor box oil filled type of capacity 15 KVAr, 440 volt 3 phase incl making connection to existing MCCB/Contactors incl taking down old unsv complete all as specified & as diretced. Each Excess(+) Full Conversion INR
M& L for on site repair of front and rear doors LT Panel of size 500mm x 500mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed Each Job Excess(+) Full Conversion INR
M& L for on site repair of front and rear doors LT Panel of size 1000mm x 800mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed Each Job Excess(+) Full Conversion INR
M& L for on site repair of front and rear doors LT Panel of size 1200mm x 800mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed Each Job Excess(+) Full Conversion INR
M& L for on site repair of front and rear doors LT Panel of size 1500mm x 1000mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed Each Job Excess(+) Full Conversion INR
M& L for on site repair of front and rear doors LT Panel of size 2000mm x 1000mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed Each Job Excess(+) Full Conversion INR
Supply and fixing in repair of Manual Changeover switch 200 Amps ,4 Pole ,I-O-II operation supplied with bridging bars,extended shaft and IP65 pistol type handle with SS Enclosure and make electric connection complete all as specified and as directed. Each Excess(+) Full Conversion INR
Supply and fixing in repair of Manual Changeover switch 400 Amps ,4 Pole ,I-O-II operation supplied with bridging bars,extended shaft and IP65 pistol type handle with SS Enclosure and make electric connection complete all as specified and as directed. Each Excess(+) Full Conversion INR
Dismantling and taking down old unserviceable LT busbar panel and Supply, installation, testing and commissioning of LT busbar Panel board not less than 0.5m x 0.6 m x0.50 m , outdoor cubical type factory made (CPRI approved) with canopy,double door , front & back both side openable type fixed with Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 400 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers with danger notice plate. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate complete all as specified & as directed. Each Excess(+) Full Conversion INR
M&L repairs to existing LT panel / bus bar chamber / feeder pillar box of any size by excavation of all loops and removing damaged UG cable, connecting new thimbles / lugs / cable glands and fixing of new neoprene rubber gasket to make it completely dust and vermin proof, fixing of new locking arragement and replacement of LT panel wiring with appropriate size of copper conductor, repairing of rusted parts of panel frame and shutter with necessary welding works including preparation and applying one coat of synthetic enamel paint on both internal and external surface of panel, PCC (1:3:6) type C2 (using 40mm crushed stone aggregate) work in foundation complete all as specified and directed. Note:-The unit rate quoted is deemed to include cost of earth work, PCC in foundation, new thimbles / lugs / cable glands, neoprene rubber gaskets, locking arrangement, Wiring, welding works, painting. Each Job Excess(+) Full Conversion INR
Supply & fixing in repair of ACB 4 Pole, 415 V, 50kA with Thermal Magnetic Release (Manual Drawout type) of capacity 630 Amps including taking down old unsv complete all as specified and as directed. Each Excess(+) Full Conversion INR
Supply & fixing in repair of ACB 4 Pole, 415 V, 50kA with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps including taking down old unsv complete all as specified and as directed. Each Excess(+) Full Conversion INR
Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV at the gap of 2.5 mm and refilling the same all as specified and directed by Engineer-in-Charge. Note:-(a) Dehydration plant to be brought at site by the contractor. (b)Dehydration and filteration to be carried out when the transformer is on load at site and rate quoted shall deemed to be included the cost of arrangement of plant by the contractor and its transportation at site. Ltr Excess(+) Full Conversion INR
Supply and topping up / filling of fresh transformer oil conforming to ISD-335/BS of dielectric strength 50 KV at the gap of 2.5 mm minimum for transformer complete all as specified & directed by Engineer-in-charge. Ltr Excess(+) Full Conversion INR
Supply and fixing in repairs of MCCB TPN DB 4 way vertical type double door ,IP-43 protection, isolated neutral bar,insulated busbar assembly,mechanical impact strength of IK08,suitable for MCCB's upto 160 Amps as incomer incl taking down old unsv complete all as specified and directed by Engr-in-charge. Each Excess(+) Full Conversion INR
Supply and fixing in repairs of MCCB TPN DB 6 way vertical type double door ,IP-43 protection, isolated neutral bar,insulated busbar assembly,mechanical impact strength of IK08,suitable for MCCB's upto 250 Amps as incomer incl taking down old unsv complete all as specified and directed by Engr-in-charge. Each Excess(+) Full Conversion INR
Supply and fixing in repair of MCB DP 40 Amps 'C' series 10kA 240 volts complete all as specified and directed. Each Excess(+) Full Conversion INR
Supply and fixing in repair of MCB SP 6-32 Amps 'C' series 10kA 240 volts complete all as specified and directed. Each Excess(+) Full Conversion INR
Supply & fixing in repairs of LED post top lantern IP-65 energy saving environment friendly with high power LED (white/warm white on redquired basis) as light source with opal cover soothing uniform illumination of capacity 25 Watt,230 Volt AC complete incl 40 mm dia GI Pipe light grade not less than 1 mtr length and formation of PCC block not less than (0.30mx0.30mx0.30 m) for groutiing of GI pipe in the foundation complete all as specified & as directed. Make:- Havells RUBY LED/Philips/Bajaj Each Excess(+) Full Conversion INR
Supply & fixing in repairs of LED bollard light fitting IP-65 designed as aluminium landscape for diffused lighting of capacity 9 Watt,230 Volt AC (white/warm white on redquired basis) incl formation of PCC block not less than (0.30mx0.30mx0.30 m) and suitable size nut bolts & washers for groutiing complete all as specified & as directed.Make:- Philips Pylon Pedestal Black 9W WW Each Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.