Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC GE W COLABA MUMBAI | CHANDRAPUR | MAHARASHTRA | 441205 | ₹1.3 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.4 Cr+₹2.7 L (2.05%)Rejected-Finance 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | ₹1.4 Cr+₹2.7 L (2.05%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹1.5 Cr+₹18.5 L (13.8%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | ₹1.5 Cr+₹18.5 L (13.8%) | L3 | Rejected-Finance Other than being lowest |
| Sl No | Description | Qty | Unit | the bhimani group of companies L2 | SN CONSTRUCTION L1 | Bob Enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone /boulder masonry built in cement mortar, including all quoins, arches, pillars, etc | 45 | Cum | 10 ₹450 Lowest | 295 ₹13,275 | 360 ₹16,200 |
| 2.00 | M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. | 45 | Cum | 3,400 ₹1,53,000 | 2,975 ₹1,33,875 Lowest | 4,600 ₹2,07,000 |
| 3.00 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc including errection of double steel scaffolding covering with green cloth and all the safety measures/ precautions and remove the debries outside MD landcomplete all as specified and as directed. | 2,800 | Sqm | 10 ₹28,000 Lowest | 14 ₹39,200 | 18 ₹50,400 |
| 4.00 | Material and Labour for repair to Spalling of concrete, damaged surface of RCC elements like beams, columns, wall, slab by removing all loose cement plaster/concrete, dust, oil, paint, grease, waterproof coating etc, Expose fully any corroded steel in the repair area and remove all scale and corrosion deposits , apply rust remover for rust free bars, apply Dr. fixit Epoxy zinc primer over the cleaned rebars and allow it to dry before pouring of Dr Fixit micro concrete or equivalent approved availabale from list of manufacturers , appllying one coat of Dr fixit epoxy bonding agent or equivalent approved availabale from list of manufacturers before pouring of mix concrete, providing and laying of micro concrete at least upto 20mm thickness (average) by using the recommended water powder ratio mix the microconcrete with pan mixer as per manufacturer's instruction including watertight shuttering at any position including necessary curing and remocal of debris outside MD land complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rate of rust remover, Epoxy zinc primer, Epoxy bonding agent and micro concrete is included in this item. | 250 | Sqm | 325 ₹81,250 | 205 ₹51,250 Lowest | 600 ₹1,50,000 |
| 5.00 | M&L for 20mm thick plastering in cement & sand mortar 1:4 in 2 coats (15 mm thick backing coat and 5 mm thick setting coat mixed with water proofing compound) on fair faces of brick work or stone masonary surfaces, finished even and smooth without using extra cement and all necessary scaffolding etc complete all as specified and directed (WPC shall be mesured and paid seperately). | 1,000 | Sqm | 320 ₹3,20,000 | 255 ₹2,55,000 Lowest | 270 ₹2,70,000 |
| 6.00 | M&L for 15mm thick plastering in cement & sand mortar 1:6 on fair faces of brick work or stone masonary surfaces, finished even and smooth (w/o using extra cement) including all necessary scaffolding etc complete all as specified and directed. | 500 | Sqm | 200 ₹1,00,000 | 205 ₹1,02,500 | 160 ₹80,000 Lowest |
| 7.00 | M&L for 5mm thick rendering on concrete surfaces as in ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified | 1,300 | Sqm | 100 ₹1,30,000 Lowest | 125 ₹1,62,500 | 144 ₹1,87,200 |
| 8.00 | Supply only integral water proofing compound, ISI marked. | 75.3 | Kg | 50 ₹3,765 | 40 ₹3,012 Lowest | 45 ₹3,388.5 |
| 9.00 | M & L for applying rustic texture paint of 3mm thick of desired finish as approved by GE over a coat of exterior wall primer which includes preparation of old/new decorated surfaces, cleaning of loose paint , grease , growth of fungus, algae or moss by using wire brushing and watering and applying two coats of exterior emulsion paint complete all as specified and directed. | 1,000 | Sqm | 470 ₹4,70,000 Lowest | 475 ₹4,75,000 | 504 ₹5,04,000 |
| 10.00 | Material and Labour for preparation of newly plastered surfaces and applying two coats of oil emlusion distemper white or tinted over a coat alkali resistant priming paint over 3mm thick wall care putty on wall complete all as specified and as directed . | 500 | Sqm | 80 ₹40,000 | 47 ₹23,500 Lowest | 54 ₹27,000 |
Tender Value
₹1.4 Cr
EMD Value
₹2.0 L
Closing Date
3 Jul 2025, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
SPECIAL REPAIRS TO BUILDING NO. P 01 (PRONGSBAY) AT NOFRA, COLABA, MUMBAI
2025_MES_711726_1
8631/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
210 days
GE (NW) NOFRA
Class B
Category a(i)
7 documents required · 7 mandatory
₹1,000
GE (NW) NOFRA
₹2.0 L
Yes
25 Sept 2025
31 May 2025
5 Jul 2025
31 May 2025
3 Jul 2025
21 Jun 2025
31 May 2025 - 20 Jun 2025
Amount
Demolition of brick work or stone /boulder masonry built in cement mortar, including all quoins, arches, pillars, etc
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc including errection of double steel scaffolding covering with green cloth and all the safety measures/ precautions and remove the debries outside MD landcomplete all as specified and as directed.
Material and Labour for repair to Spalling of concrete, damaged surface of RCC elements like beams, columns, wall, slab by removing all loose cement plaster/concrete, dust, oil, paint, grease, waterproof coating etc, Expose fully any corroded steel in the repair area and remove all scale and corrosion deposits , apply rust remover for rust free bars, apply Dr. fixit Epoxy zinc primer over the cleaned rebars and allow it to dry before pouring of Dr Fixit micro concrete or equivalent approved availabale from list of manufacturers , appllying one coat of Dr fixit epoxy bonding agent or equivalent approved availabale from list of manufacturers before pouring of mix concrete, providing and laying of micro concrete at least upto 20mm thickness (average) by using the recommended water powder ratio mix the microconcrete with pan mixer as per manufacturer's instruction including watertight shuttering at any position including necessary curing and remocal of debris outside MD land complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rate of rust remover, Epoxy zinc primer, Epoxy bonding agent and micro concrete is included in this item.
M&L for 20mm thick plastering in cement & sand mortar 1:4 in 2 coats (15 mm thick backing coat and 5 mm thick setting coat mixed with water proofing compound) on fair faces of brick work or stone masonary surfaces, finished even and smooth without using extra cement and all necessary scaffolding etc complete all as specified and directed (WPC shall be mesured and paid seperately).
M&L for 15mm thick plastering in cement & sand mortar 1:6 on fair faces of brick work or stone masonary surfaces, finished even and smooth (w/o using extra cement) including all necessary scaffolding etc complete all as specified and directed.
M&L for 5mm thick rendering on concrete surfaces as in ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified
Supply only integral water proofing compound, ISI marked.
M & L for applying rustic texture paint of 3mm thick of desired finish as approved by GE over a coat of exterior wall primer which includes preparation of old/new decorated surfaces, cleaning of loose paint , grease , growth of fungus, algae or moss by using wire brushing and watering and applying two coats of exterior emulsion paint complete all as specified and directed.
Material and Labour for preparation of newly plastered surfaces and applying two coats of oil emlusion distemper white or tinted over a coat alkali resistant priming paint over 3mm thick wall care putty on wall complete all as specified and as directed .
M&L preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkaline resistent primer on ceiling any height including necessary scaffolding complete all as specified and as directed.
M&L complete removal of existing treatment, preparation of old plastered surfaces of wall and applying two coats of oil emlusion distemper over a coat wall care putty of 3mm thick and alkali primer on the existing surface, any height including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge.
M&L complete removal of existing treatment, preparation of old plastered surfaces on ceiling and applying two coats of oil bound distemper over a coat of alkaline resistent primer complete all as specified and as directed by Engineer-in-Charge.
Demolition of plain cement concrete of any description and in any position not other wise specifically provided for any description.
Roughening Surfaces of old Concrete Floor by picking, sweeping clean and washing down with water to remove dust etc brussing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified and as directed
M&L for PCC 1:2:4 type B0 (12.5 mm graded stone aggregate) as in roof kerbs/pading or mud stops, rounded or chamfered on edegs using Pidiproof LW+ water proofing chemical of Dr. Fixit or equivalent as per manufacturer's instruction, etc complete all as specified. (Water Proofing Chemical shall be measured and paid seperately).
Supply only Water proofing chemical Pidiproof LW+ of Dr. Fixit or Equivalent.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified
S&F Rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) of Fe-410-W(Gde-E-250) quality-B including distance pieces, cleats etc. complete all as specified
S&F Rolled mild steel as in Joist, channel, angle, or tee sections Fe 410 -W(Gde-E- 250) quality-A, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified
S&F for rolled mild steel plates of Grade Fe 410-W, (Gde- E-250) quality-A as in connecting pletes, base plate etc. welding etc complete all as specified and directed
M&L for preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified incl all necessary scaffolding etc. complete all as specified
Dismantling plain or corrugated steel sheeting any guage, thickness, including Nainatal or similar pattern roof coverings complete all as specified
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed.
All as per item No.24 above but plain sheets as in ridges/flashing.
Taking down eaves/valley gutter and rain water pipes/PVC pipes/CI pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-neck,etc. ( measured over all as fixed along the centre line over fittings and accessories)
M & L for 1.5 mm thick galvanised steel sheet as in Valley gutters fixed with rivets or other suitable arrangements over MS brackets Trapezoidal shape of required profile with desired slope etc at a height exceeding 10 metre but not exc 20 metre, complete all as specified and as directed.
Supply & fixing 160mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in wall of approved shape and size approved by GE at any height, any location, with dash through fasteners and rain water bracket suitable for 160mm pipes spacing 1.5 c/c as per CE Navy Mumbai TD/2023/01 including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge. (Note:- Measurment shall be taken along the centre line of the pipes.)
M & L for PCC 1:2:4 type B-2 type (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete including necessary formwork includig demolition complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M & L for Non skid coloured ceramic tiles 7 to 8 mm thick ( square/ rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of the tiles including 20mm thick screed bed in CM 1:4 complete all as specified.
M & L for Coloured glazed ceramic tiles in vertical surface 450 X350X7-8 mm thick , set and jointed in neat cement paste and pointed in coloured cement to match the shade of the tiles including 10 mm thick backing coat in CM 1:3 complete all as specified.
M&L full body vitrified tiles/slabs 14-16mm thick 2400mmX800mm dark shade in flooring and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 20mm thick screed bed in CM 1:4 all as specified and directed .complete all as specified.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar
M & L Machine cut mirror polished kota stone slab flooring 22-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl 15mm thick Screed bed or bedding layer in CM 1:4 complete all as specified complete all as specified.
M & L 18-20 mm thick mirror polished Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
M&L for 18-20 mm thick prepolished polished Green Marble slab (of any type) work (table rubbed and polished) in floors, steps, jambs, pillars, window-cills, cooking platforms over including bedding layer of 20mm thick in cement mortar (1:4) for laying floor finishes including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
S & F for extra over granite stone slabs for edge polishing/ chamfering/ noising/ grooves/ bevelling etc complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed
Providing & fixing false ceiling at any heights with semi perforated 12mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4) -1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per direction of the Engineer-in-Charge.
S&F powder coated aluminium frame/shutters for partition, doors, windows, ventilators etc. including joining cleat for fixing, PVC rollers, locking arrangement, rubber beading, rubber gasket, screws, handles, hinges, tower bolts etc. including dismantling complete all as specified. Note :- (i) Glazing and wire mesh shall be measured and paid separetely for supply only as the labour element included in this item. (ii) Item shall be paid as per weight of aluminium section. (iii) the rete quoted shall be inclusive of the cost of neoprene beading, glazing pin. screws and powder coated fittings such as hinges, handles, locking arrangement etc as required, which shall not be measured for arriving the weight. (iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area.
S&F 4 mm thick sheet glass, ordinary quality, in any size of pane complete all as specified and as directed
S&F 4 mm thick figured glass, pin headed type, in squares n exc 0.5 Sqm in each pan complete all as specified and as directed
S&F in repairs Sun control film, 50 micron non reflective type, sticked to glass as per manufacturers instructions and as directed by EIC
S&F 4 mm thick bakelite sheet with decoratve choice laminated on both side completion as specified and as directed
S&F 12 mm thick Medium density fibre board, exterior grade both side decorative choice laminations, fixed to timber/ Aluminium frame work with screws completion as specified and as directed
S&F aluminium (Die cast) body, door closer, hydraulically regulated, desig. No. 2, unversal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg completion as specified and as directed
S&F Aluminum alloy anodized sliding door bolt 300mm long with hasp and staple (bolt type) and fixing bolts and sliding bolts of extruded such or cast aluminum alloy complete all as specified and as directed
S&F stainless steel butt hinges of size 100mm all as specified and directed.
S&F Aluminium alloy anodised barrel tower bolt 100mm long complete all as specified and as directed
S&F Aluminium alloy anodised barrel tower bolt 150mm long complete all as specified and as directed
S&F extruded aluminium alloy handle fabricated type anodized 100mm long complete all as specified and as directed
S&F extruded aluminium alloy handle fabricated type anodized 150mm long complete all as specified and as directed
M&L for Steel rolling shutters 1.25mm thickness of lath sheet without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; gear operated type with bevel gear box and crank handle as in repair incl removal of old rolling shutter from the MoD land complete all as specified and directed.
S & F Safety lever locks mild steel with 4 levers for rolling shutters completion as specified and as directed
S & F 3 mm thick Aluminium composite panel cladding plain metallic of approved colour/ shade to beam/ column/ slab in circular/ rectangular shape including cutting, notching, bending to shape as required jointing with silicon gel of approved colour & Aluminum tubular hallow section 25 x 25 mm not exceeding 900 mm c/c on exceeding col/beam/ slab to hold APC cladding etc. including dismantling complete all as specified and as directed. (Note:- Colour/ Pattern of ACP sheet shall be given by GE)
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including dismantling complete all as specified and as directed
S&F 12mm thick toughened glass for door shutters, partitions, shelves etc with and including fitting and fixtures such as glass handles SS studs, fitting for door pivots etc including taking down complete all as specified.
S&F SS 202 Stain finish Handle D type, 25mm dia 600mm long for glass shutter Cat No. TDH102 or technocommercial equivalent Make given in Appx B completion as specified and as directed
S&F bottom/top patch fitting for pivot Cat No. TPF -10 or technocommercial equivalent Make given in Appx B completion as specified and as directed
S&F bottom lock patch fitting Cat No. TPF -50 or technocommercial equivalent Make given in Appx B completion as specified and as directed
S & F mortice lock, 4 lever vertical type, size 100mm or technocommercial equivalent Make given in Appx B completion as specified and as directed
S & F in repair double action floor spring hydraulically regulated made up of minium 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as per manufacturer's instruction.
S&F 50mm low density polyethylene pipes (LDPE) of pressure rating 6 kgf/Sqcm fixed complete to walls, ceilings or in floors etc in repairs completion as specified and as directed
Supply & fixing 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in wall of approved shape and size approved by GE at any height, any location, with dash through fasteners and rain water bracket suitable for 110mm pipes spacing 1.5 c/c as per CE Navy Mumbai TD/2023/01 including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in wall of approved shape and size approved by GE at any height, any location, with dash through fasteners and rain water bracket suitable for 75mm pipes spacing 1.5 c/c as per CE Navy Mumbai TD/2023/01 including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge.
M&L PVC SWR floor trap 75mm, plain with grating including setting and jointing with solvent cement fixed in repairs.
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified.
Material and Labour for concealed point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic conduit Concealed in wall of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular Cover plate concealed in wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :-
(a) One light point controlled by one switch SP one way.
(c) One Ceiling/Exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
Material and Labour for concealed point wiring complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic conduit concealed in wall of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular Cover plate concealed in wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly.
Supply and fix in repair Modular Switch, 6Amp, One way, 1 module.
Supply and fix in repair Modular blank plate, One way, 1 module.
Supply and fix in repair Modular Switch, 16Amp, One way, 1 module.
Supply and fix in repair ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified.
Supply and fix in repair Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module.
Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module.
Supply and fix in repair Modular white cover plate with Frame 1 Module.
Supply and fix in repair Modular white cover plate with Frame 2 Module.
Supply and fix in repair Modular white cover plate with Frame 3 Module.
Supply and fix in repair Modular white cover plate with Frame 4 Module.
Supply and fix in repair Modular white cover plate with Frame 6 Module.
Supply and fix in repair Modular white cover plate with Frame 8 Module.
Supply and fix in repair Modular white cover plate with Frame 12 Module.
Supply and fix in repair Modular metal flush box 1 module.
Supply and fix in repair Modular metal flush box 2 module.
Supply and fix in repair Modular metal flush box 3 module.
Supply and fix in repair Modular metal flush box 4 module.
Supply and fix in repair Modular metal flush box 6 module.
Supply and fix in repair Modular metal flush box 8 module.
Supply and fix in repair Modular metal flush box 12 module.
Supply and fixing Recess Mounting LED panel, 2'x2', 36 Watt (min 120 lumen/watt) capacity, fully diffused, white powder coated, with polymer diffuser complete with acessories all as specified and directed .
Supply and fix in repair Linear PVC Baten LED T/L 20W (min 120 lumen/watt) Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified.
Supply and fixing Recess Mounting LED panel, COB light, 18 Watt (min 120 lumen/watt) capacity, CRCA housing, white powder coated, with 36 degree beam angle, 3000K CCT complete with acessories all as specified and directed .
Taking down MCB DB of any type, single phase including disconnection of all circuits complete with MCBs etc.
Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-54, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :-
(a) MCB SPN 63 Amps, 240 Volts - 01 No
(b) MCB SP 6-32 Amps, 240 Volts.
S&F 8 way Double door type having protrection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :-
S & F MCB SPN 40 Amps, 240 Volts, C Series .
S & F MCB SP 6-32 Amps, 240 Volts, C Series .
Supply and fix in repair single phase sheet metal powder coated double door distribution board 4 way complete all as specified and directed. (a) MCB SPN 40Amps 240Volts, 10KA - 1 No ('C' Series) (b) MCB SP 6 - 32Amps 240Volts - 2No ('C' Series)
S&F in repairs sheet metal enclosure 2 way without bus bar with MCB (a) Isolator DP 63 Amps Breaking capacity 10 KA. (C series)
Taking down Ceiling / Exhaust fan of any size, sealing cable end, dismantling blades carefully and removing fan and blades including Painting of ceiling fans/exhaust fans complete and refifixing the same, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.to MES E/M Store for refixing at the same place all as directed by Engr-in- charge.
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces.
S&F 2 single core FRLS 1100 volts grade cable with stranded copper conductor of size 6 Sqmm in and including including PVC conduits of suitable size Concealed in Wall not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 6.0 sqmm (green colour) for earthing. Note : 3 runs of 6Sqmm cable, 1 run of PVC conduit and 1 run of 6.0 Sqmm cable shall be measured as 1 Run.
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of 3 Runs of size 4 Sqmm in and including PVC conduit concealed in wall of size not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. Note :- (i) Three runs of 4Sqmm cable, and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC Conduit
Supply, laying, commisssion & testing XLPE insulated armoured LT cable, 110 Volts grade with aluminium conductor of size 4 core 16 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc complete all as specified and directed.
Supply and fix submain wiring in repair 2 single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC conduit concealed in wall of size not less than 25mm dia including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing. Note :- (i) Two runs of 10 Sqmm cable, 1 run of PVC casing caping/ conduit and 1 run of 10 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping / conduit
Supply, laying including testing and commissioning PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 150 Sqmm laid in trenches/through pipe /ducts or fixed on wall etc complete all as specified & directed.
Supply and fixing Recess Mounting LED panel, 1'x1', 36 Watt capacity (min 120 lumen/watt), CRCA housing, white powder coated, with polymer diffuser complete with acessories all as specified and directed.
Supply & fix in repair MCB DB, TPN 8 way vertical type, 415 V with 200 Amps rated bus bar and double door connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed, comprising of the following : - (a) MCCB 4 Pole, 415 V fixed type, 160 Amps with breaking capacity 25 KA-01 Nos (incoming) (b) MCB TP 63 Amps, 10KA - 06 Nos (B Series) (Outgoing) (c) MCB SP 40 Amps, 10KA - 06 Nos (B Series) (Outgoing)
Supply & fixing in repairs LED Flood light fittings 70 Watt (min 110 lumen/watt) capacity in single die ceramic base high power LED, PDC Housing and unique flood optics (NB) to ensure uniform distribution , IP 65/66, 10KV SPD, including wiring complete including bracket to fixed the lights in positions all as specified & directed by Engineer - in - Charge.
S&F Rigid non-metallic PVC casing caping/conduit inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of medium grade, ISI mark, 25mm width cable TV, internet, telephone cable complete all as directed.
Supply, install, testing and commissioning of LT Feeder Pillar CPRI Approved mounted on angle iron frame and grouted on floor,cubical outdoor type, with both side opening and suitable for site with suitable fixing of all breakers and controls for 415V, 3 phase, made of 3.15 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 800 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmework and PCC foundation including shifting of existing of LT Panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following
(a) MCCB 400 Amps, 36 KA,(Incoming) FP - 01 Nos
(c) MCCB 160 Amps, 36 KA, FP(outgoing) - 04 Nos
(c)MCB 63 Amps,16 kA,FP(Outgoing)-04 Nos
(d)MCB 40 Amps,16 kA,DP(Outgoing)-02 Nos
(f) Aluminium Bus bar 800 Amps for phase & 600 Amps for neutral complete with bus bar insulator,nuts & bolts complete.
(g) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , single core ,1100 volts grade of appropriate size complete with copper lugs
the bhimani group of companies (BID ID -3332697)
Bob Enterprises (BID ID -3337753)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .