| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.4 L+₹2.2 L (7.86%)Rejected-Finance JAISALMER | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹31.0 L+₹2.8 L (9.96%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹31.5 L+₹3.3 L (11.8%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹33.3 L+₹5.1 L (18.1%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹42.5 L
EMD Value
₹85,060
Closing Date
26 Mar 2024, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
PROVN OF AN ADDITIONAL FRESH ISSUE SHED FOR LAYOUT AND ISSUE OF POTATO AND ONION AT CERTAIN UNIT AT MIL STN JAISALMER
2024_MES_643449_1
8361/23-24/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹85,060
Yes
27 Nov 2024
21 Feb 2024
28 Mar 2024
21 Feb 2024
26 Mar 2024
6 Mar 2024
Amount
Surface excavation not exceeding 15 cm deep and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and n exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exceeding 1.5 m in depth and in soft/loose soil complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as specified & directed by Engineer-in-Charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified & directed by Engineer-in-Charge
M&L plain Cement Concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by the Engineer-in-Charge.
M&L squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified & directed by Engineer-in-charge.
M & L plain cement concrete (1:2:4) type B0 (using 12.50mm graded stone aggregate) as in coping including necessary form work with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified & directed by Engineer-in-charge.
M&L for Keyed pointing to squared rubble masonry, coursed or uncoursed in CM 1:4 complete all as specified & directed by Engineer-in-charge.
M&L for precast cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in block masonry with solid blocks exceeding 10cm width and setting in cement mortar (1:6) complete all as specified & directed by Engineer-in-Charge.
M&L for rendering 15 mm thick plaster in cement mortar (1:4) on fair faces of brick work or concrete surfaces of walls finished the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick, plaster in cement mortar (1:6) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing finished the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of distempering oil emulsion over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified & directed by Engineer-in-charge.
M&L for 75 mm thick plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring/ hard standing & finished the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregates) as in floor finished even & fair without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for machine cut kota stone flooring 550 x 550x 20 to 25mm thick laid over and including screed bed or bedding layer of 15mm thick in CM (1:6) jointed and pointed with grey cement slurry mixed with pigment to match the shade of tiles including rubbing and mirror polishing complete all as specified & directed by Engineer-in-charge.
M&L for machine cut kota stone slab 18 to 20mm thick on in vertical surfaces in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in CM (1:4) jointed and pointed with grey cement slurry mixed with pigment to match the shade of tiles including rubbing and mirror polishing complete all as specified & directed by Engineer-in-charge.
M&L for 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) laid in alternative bays as in plinth protection including finished the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25, 3 parts of sand by weight complete all as specified and directed by Engineer-in-charge.
S&F mild steel rolled sections Fe 410W (Gde-E 250 quality B) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed by the Engineer in charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
M&L Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25 to 35cm wide, hoisted and set, jointed and grouted in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in levelling/ padding course over jodhpur stone roof slab surface including rounded or chamferred on edges etc., mixing with approved liquid water water proofing compound all as per manufacturer's instructuions on the roof surface to achieve requisite slope all as specified and directed. (Note :- Supply only liquid water proofing compound shall be measured & paid separately).
Supply only liquid water proofing compound complete all as specified & directed by Engineer-in-charge.
M&L for providing 3 mm thick APP modified memberane over RCC roof with the following specifiations :-
ITEM No. 29.00 CONTD... (a) Cleaning existing surface properly & rendering 15mm thick in CM 1:4 without using extra cement finishing surface even & smooth. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface. (c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :- (i) Membrane weight >3.6 Kg/Sqm . (ii) Net wooven polyster weight >160 gm/Sqm (iii) Softening point of membrane > 150o C (iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm (v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction
ITEM No. 29.00 CONTD... (vi) Elongation > 30 % (vii) Impermeability under water pressure > 3 Kg/Sq cm Note:- APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane.
M&L aluminium frame powder coated (minimum thickness of powder coating 50 micron) for doors, windows ventilators with one or more rebates including joining cleat for fixing etc complete all as specified & directed by Engineer-in-charge.
S&F powder coated aluminium door shutters (minimum thickness of powder coating 50 micron) aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified & directed by Engineer-in-charge.
S&F for aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified & directed by Engineer-in-charge.
S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified & directed by Engineer-in-charge.
S&F, glavanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tack or galvanised wire stapples complete all as specified & directed by Engineer-in-charge.
S&F plain sheet glass of 4.8mm thick ordinary quality and glazing with oil putty and clips in squares not exceeding 0.50 Sqm in each pane complete all as specified & directed by Engineer-in-charge.
M&L for Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.6 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano Type switches, sockets, fan regulators complete for the following :-
(a) One light/ceiling fan point controlled by one switch.
(b) One socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 36.00 here on before but with copper conductor cable of nominal class area 2.50 sq mm for phase, neutral & earth for One 2/3 pin socket outlet 5 Amps on independent board complete all as specified & directed by Engineer-in-charge.
All as per item No 36.00 here on before but with copper conductor cable of nominal class area 4.0 sq mm for phase, neutral & earth for power socket point 15 Amps complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 5/6 amp complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 16 amp complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-charge.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified & directed by Engineer-in-charge.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete all as specified & directed by Engineer-in-charge.
Supply and fixing of LED box type integrated batten 40 watt having aluminum extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 mm (Length) X 40 mm (Width) X 63 mm (Height ). Lumens output of the fitting shall be not less then 4000 lm, CCT 5700 – 6500 K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95, Separate detachable type Electronic constant current drivers for easy replacement and aintenance, THD < 10% , Necessary mounting arrangements .The fixture shall be suitable for wall mounting /suspension mounting as per site requirement . The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report as per PHILIPS Cat Part No. BN100C LED40S-6500 PSU L120 GR S4 or equivalent in Appx 'C' list of makes.
S&F building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as Lighting souce and PC cover having TOP opening sepreate drive compartment etc and connecting complete all as specified & directed by Engineer-in-charge.
S&F bracket of GI pipe medium grade of 40mm dia, 1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts, bolts & washers, painting and including taking down existing bracket complete all as specified & directed by Engineer-in-charge.
S&F fans ceiling fans complete with three blade, down rod, accessories 230 V, 1200 mm sweep necessary connecting cable recommended / provided by manufacturer complete all as specified & directed by Engineer-in-charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer including MCCB 100 A , and with SP/TP MCCB's as incoming MCCB FP 100 A, 25 KA complete all as specified & directed by Engineer-in-charge.
S&F for MCB DB SPN 12 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply & fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified & directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron wire 4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion and including taking down existing earthing complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 56.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing wire from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with GI wire 4 mm mm size complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 20 mm bore, 'light grade' galvanised, with all fitting and fixed to walls and ceilings or laid in floors in trench on pole for protection of cable etc complete all as specified & directed by Engineer-in-charge.
Supply, installing, commissioning and testing of hi wall split type air conditioner units of capacity 1.5 TR, indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality 5 star rating and EER 3.2 non CFC type with nominal cooling capacity system complete all as specified & directed by Engineer-in-charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified & directed by Engineer-in-charge.
M & L for XLPE insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,cross sectional area size 50 Sqmm x 3.5 Core complete all as specified & directed by Engineer-in-charge.
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment.
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 50 mm bore, 'light grade' galvanised laid in trench for protection of cable etc complete all as specified & directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom, burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground levl connected to galvanized iron strip 32 x6 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection all necessury earth work ,excavation ,earth chamber with PCC 1:3:6 type C2 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on completion complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 67.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply, installation, testing and commissioning LT Feeder pillar/Panel board cubical type outdoor conforming to IS 8623 Part 1 1993, factory fabricated out of 3.15 mm thick CRCA sheet & suitable size to accommodate all acceessories / fitting, compartmentalized in construction to accomodate incoming and outgoing, MCCB, MCB and TPN Aluminium Bus bar of rating not less 1.5 times the rated capacity of incomer MCCB/ACB and outdoor feeder. The TPN bud bar shall insulated with color coded heat shrinkable sleeve and shall be mounted on DMC/ Epoxy insulators of suitable size through out the length of TPN bus bar. The incoming as well as outgoing MCCBs shall have copper extension link of current carrying cap not lass than 1.5 times the rated capacity of individul feeders.
ITEM NO. 68.00 CONTD... The extension link shall be supported on DMC /Epoxy insulators having provision for termination of incoming and outgoing cables . All extension links / interconnection shall be insulated with heat shrinkable colour code sleeves. The cubical shall have a bottom channel of size 50x50X5 mm and and 45 cm height above the ground level duly fixed with PCC . a detachable predrilled gland plate of thickness not less than 3 mm thick should be used at a bottom for enrty of armoured cable of adequate size with glands. The above panel shall be front and back openable /lockable by the key from both side and shall have louvers and air vent gasket for natural floe of air.XLPE adhesive type gasket shall be used to make the panel weather , dust and vermin proof with IP 65 degree of protection ,complete as specified and consisting the following switchgears and accessories.:-
JASOL MAA ENTERPRISES
Bhawani Constructions
M/s Shree Construction Company
M/s Ramniwas Bishnoi
AMBEY MAA CONSTRUCTION COMPANY
Paliwal Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .