Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹19.6 L+₹3.5 L (22.0%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Mar 2021, 6:00 pmClosed
Maj Rahul Rawat
GE Utility Bathinda Mil stn
REPAIR / MAINTENANCE OF STPS AT DIFFERENT LOCATIONS UNDER GE (UTILITY) BATHINDA.
2021_MES_424362_1
8540/2020-21/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda MIil Stn
class E cat a ii
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility Bathinda
₹40,000
Yes
27 Mar 2021
22 Feb 2021
24 Mar 2021
22 Feb 2021
22 Mar 2021
8 Mar 2021
Amount
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of diameter 3.6 mtr at a depth of upto 6 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer-in-charge. ( Pocket -01 & Pocket -08)
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of diameter 3.8 mtr at a depth of upto 8 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer-in-charge.(Pocket No:05)
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of diameter 3.6mtr at a depth of upto 6 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer-in-charge.(Pocket No:10)
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of diameter 3.6mtr at a depth of upto 6 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer-in-charge.(Pocket No:12)
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of diameter 3.8mtr at a depth of upto 6 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer-in-charge.(Jadunath STP)
Cleaning and removing sludge from walls /floor of one Nos Equilization tank & Treated water open tank of dia 5.5 mtr & 6.2 mtr with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed by Engineer - in -Charge.(Pocket No:10)
Cleaning and removing sludge from walls /floor of one Nos Equilization tank & Treated water open tank of dia 8.2 mtr & 4.4 mtr with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed by Engineer - in -Charge.(Pocket No:01 & 08)
Cleaning and removing sludge from walls /floor of one Nos Equilization tank & Treated water open tank of dia 5.5 mtr & 4.0 mtr with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed by Engineer - in -Charge.(Pocket No:012)
Cleaning and removing sludge from walls /floor of one Nos Treated water open tank of size 5.90 x 5 x 6.0 mtr with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed by Engineer - in -Charge.(Pocket No:05)
Cleaning and removing sludge from walls /floor of one Nos Treated water open tank of size 8.20 x 8.20x10mtr with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed by Engineer - in -Charge.((Jadunath STP)
Cleaning,removing and bailing out stagnated sewage or sludge from walls/floor and any light particle with the help of wire brushes ,steel patti and emery paper from two Nos MBBR reactor inner surface of size 3.5 x 3.5 x 5.0 meter and taking out damaged and unbroken MBBR media without any damage and refilling it in each MBBR with old unbroken media and New media alongwith cleaning of inner and outer surface of MS pipe placed in MBBR and removing any sludge particle from it to entire satisfaction of Engineer-in-Charge. (Pkt-01 & Pkt-08) Note:- New media for topping up will be paid and mesaured separately under respective item of BOQ.
Cleanin,removing of sludge from walls/floor with the help of wire brushes ,steel patti and emery paper from two Nos MBBR reactor inner surface of size 2.8 x 2.8 x 5.0 meter and taking out damaged and unbroken MBBR media without any damage and refilling it in each MBBR with old unbroken media and New media alongwith cleaning of inner and outer surface of MS pipe placed in MBBR and removing any sludge particle from it to entire satisfaction of Engineer-in-Charge.(Pkt-10) Note:- New media for topping up will be paid and mesaured separately under respective item of BOQ.
Cleanin,removing of sludge from walls/floor with the help of wire brushes ,steel patti and emery paper from two Nos MBBR reactor of size 2.0 x 2.0 x4.30 meter and taking out damaged and unbroken MBBR media without any damage and refilling it in each MBBR with old unbroken media and New media alongwith cleaning of inner and outer surface of MS pipe placed in MBBR and removing any sludge particle from it to entire satisfaction of Engineer-in-Charge.(Pkt-12) Note:- New media for topping up will be paid and mesaured separately under respective item of BOQ.
Cleaning and removing of sludge from walls/floor of two Nos MBBR/FAB REACTOR of size 2.8 x 3.15 x 6.1 meter each with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - n - Charge at a distance 100 meter away from outer wall of STP including after cleaning painting to MS pipe two nos of size 200 mm dia , 6.1 m length each fixed in vertical position by using black bitumen paint and white wash to walls of MBBR/FAB REACTOR complete all as directed by Engineer - in - Charge.(Pocket No:05)
Cleaning and removing of sludge from walls/floor of two nos MBBR/FAB REACTOR of size 4.8 x 4.8 x 6.1 mtr each with the help of wire brushes, steel patti/emery paper and depositing where directed by Engr-in-Charge at a distance of 100 mtr away from outer wall of STP including after cleaning painting to MS pipe two nos of size 300 mm dia, 6.1 mtr length each fixed in vertical position by using black bitumen paint and white wash to walls of MBBR/FAB REACTOR complete all as directed by Engineer - in -Charge.(Jadunath STP)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 6.0 x 2.40 x 2.75 mtr each after taking out the tube settler media with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed by Engineer - in -Charge.(Pocket No:10)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 4.5 x 1.75 x 2.75 mtr each after taking out the tube settler media with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed by Engineer - in -Charge.(Pocket No:12)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 7.5 x 2.70 x 2.75 mtr each after taking out the tube settler with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed by Engineer - in -Charge.(Pocket No:01 & 08)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 8.0 x 3.5 x 2.75 mtr each after taking out the tube settler media with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed by Engineer - in -Charge.(Jadunath STP)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 7.10 x 2.50 x 2.75mtr each after taking out the tube settler media with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed by Engineer - in -Charge.(STP-05)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank and chlorine contact tank of dimension 3.65 x2.4 x2.4 mtr with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer - in -Charge. (Pkt-01&08)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank and chlorine contact tank of dimension 2.0 x2.0 x1.9 mtr with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer - in -Charge.(Pkt-12)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank and chlorine contact tank of dimension 2.875 x1.8 x2.5 mtr with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer - in -Charge.(Pkt-10)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank of dimension 7.10 x 1.375 x 1.8 mtr with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer - in -Charge.(Pkt-05)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank and chlorine contact tank of dimension 8.0 x 1.75 x 2.0 mtr with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer - in -Charge.(Jadunath STP)
Cleaning of existing DMF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.30m dia and height 1.65m complete all as directed by Engineer - in -Charge.(Pocket No:01 & 08)
Cleaning of existing ACF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.30m dia and height 1.65m complete all as directed by Engineer - in -Charge.(Pocket No:01 & 08)
Cleaning of existing DMF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 1.82m dia and height 1.60m complete all as directed by Engineer - in -Charge.(Pocket No:10)
Cleaning of existing ACF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 1.82m dia and height 1.60m complete all as directed by Engineer - in -Charge.(Pocket No:10)
Cleaning of existing DMF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 1.24m dia and height 1.60m complete all as directed by Engineer - in -Charge.(Pocket No:12)
Cleaning of existing ACF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 1.24m dia and height 1.60mm complete all as directed by Engineer - in -Charge.(Pocket No:12)
Cleaning of existing DMF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.4m dia and height 1.85m complete all as directed by Engineer - in -Charge.(Pocket No:05)
Cleaning of existing ACF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.4m dia and height 1.85 m complete all as directed by Engineer - in -Charge.(Pocket No:05)
Removing silt sludge and other raw material from kaccha drain with the help of JCB/Tractor and removing the sludge and depoisiting the same 50 mtr away from the starting edge of drain complete all as required at site .Note - All cost of T&P and other safety measures should be taken by the contractorwith out any extra cost complete all as directed by Engineer - in -Charge.(STP-5) & Jadunath STP
Taking out mud, coarse sand, fine sand, grit and gravel from 06 Nos sludge beds and removing to a distance not exc 50 mtr fromouter edge of Sewage treatment plant. cleaning the filter media with water and restacking as per original complete all as directed by Engineer - in -Charge.Note :- Cleaning of filter media, channels, drains etc shall be included in the quoted rate.
Taking out solid dry sewage waste from sludge beds of size 5.0x5.0x1.0 mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed by Engineer - in -Charge.(Pocket No:10)
Taking out solid dry sewage waste from sludge beds of size 6.7x6.7x1.0 mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed by Engineer - in -Charge.(Pocket No:01 & 08)
Taking out solid dry sewage waste from sludge beds of size 3.7x3.7x1.0 mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed by Engineer - in -Charge.(Pocket No:12)
Taking out solid dry sewage waste from sludge beds of size 5.40 x5.40 x 1.0 mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed by Engineer - in -Charge.(Pocket No:05)
Taking out solid dry sewage waste from sludge beds of size 5.60 x 5.60 x1.0mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed by Engineer - in -Charge.(Jadunath STP)
M&L for filling/laying the layer of naturally rounded graded gravel (white or yellow/grey/brownish) free from clay, dirt, vegetable and organic matter and should be hard, durable and superior quality of graded 50 mm first bottom layer of sludge bed in depths as per original pattern complete all as directed by Engineer - in -Charge.(Jadunath STP)
M&L for filling/laying sand free from clay, dirt, vegetable and organic matter over the second layer of rounded graded gravel of sludge bed in depths as per original pattern complete all as directed by Engineer - in -Charge.(Jadunath STP)
M&L for area cleaning under pumphouse premises as cutting/scraping of grass, unwanted trees, plant, levelling of earth surfaces, filling of digs etc complete all as directed by Engineer - in -Charge. (Dimension of concerned area 60 m x 40m) .(Jadunath STP)
Supply and fixing in repair Cast Iron butterfly valves of size 100 mm dia complete all as directed by Engineer - in -Charge. Make: LEADER / KIRLOSKAR / UPADHYA / L&T / ZOLOTO / NORMEX VALVES PVT LTD, PUNE.
Supply and fixing in repair Cast Iron butterfly valves of size 80 mm dia complete all as directed by Engineer - in -Charge Make: LEADER / KIRLOSKAR / UPADHYA / L&T / ZOLOTO / NORMEX VALVES PVT LTD, PUNE.
Supply and fixing in repair Cast Iron butterfly valves of size 50 mm dia complete all as directed by Engineer - in -Charge. Make: LEADER / KIRLOSKAR / UPADHYA / L&T / ZOLOTO / NORMEX VALVES PVT LTD, PUNE.
Dismantling the electric induction motor AC 3 Phase, capacity 3.0 HP, 440 V, 1440 RPM, 50 Cycle of any make and type from the foundation and pump after disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repair/rewinding, strip opening the motor and removing of defective burnt winding, rewinding the motor after cleaning the rotor and stator with super enameled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class ‘B’ varnish for insulation, re-assembling the complete motor and installing at site with electric cable connection, earthing and testing the motor on full load at site after coupling the pump for its serviceability up to entire satisfaction of Engineer-in-charge.
All as per srl item No. 47 here-in-before but electric motor of capacity 5 HP.
All as per srl item No. 47 here-in-before but electric motor of capacity 7.5 HP.
All as per srl item No. 47 here-in-before but electric motor of capacity 12.5 HP.
All as per srl item No. 47 here-in-before but electric motor of capacity 20 HP.
All as per srl item No. 47 here-in-before but electric motor of capacity 40 HP. Note for serial item No. 47 to 52 :- (i) Super enameled copper winding wire shall be measured and paid separately under appropriate item of this BOQ as supply only. (ii) Ball bearing if required shall be measured and paid separately under appropriate item of this BOQ as supply only. (iii) The T & P/vehicles etc.will be arranged by the contractor and the cost deemed to be included in the quoted rates. (iv) Any minor repairs such as re-matling/filling,grinding,welding and minor spares such as nuts,bolts,washers,'O' rings etc are deemed to be inclusive of the quoted rates.
Disconnecting the centrifugal/monoblock pumping sets of capacity 3 HP any make and model from motor and all water connections and removing/taking up from foundation transporting to civil workshop for repair/strip opening and repairing of pumping sets by changing defective/unserviceable parts such as bearing,shaft,impeller,bush,gland plate etc complete.Re-assembling including oiling greasing replacement of worn out nuts,bolts gasket etc,and installing in its original position at site making all connection ,commissioning and testing etc complete all as directed by Engr-in-charge.
All as per srl item No. 53 here-in-before but centrifugal/monoblock pumping set of Capacity 5HP.
All as per srl item No. 53 here-in-before but centrifugal/monoblock pumping set of Capacity 7.5HP.
All as per srl item No. 53 here-in-before but centrifugal/monoblock pumping set of Capacity 12.5HP.
All as per srl item No. 53 here-in-before but centrifugal/monoblock pumping set of Capacity 20HP.
All as per srl item No. 53 here-in-before but centrifugal/monoblock pumping set of Capacity 40HP. Notes for serial item No. 53 to 58: (i) Ball bearing shaft impeller bush gland plate & stuffing box packing etc replaced as per requirement shall be measured and paid separetly under appropriate item of this BOQ as supply only. (ii) The rates for minor repair of all other minor items essential for functioning the pump are deemed to be included in quoted rates. (iii) The T & P /vehicles etc will be arranged by the contractor and cost deemed to be included in the quoted rates.
Supply only steel distance pieces suitable upto 40 HP centrifugal/monoblock pumping sets complete all as directed by Engineer-in-charge. Make :- Kirloskar / As per Sample
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of Capacity 3 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of Capacity 5 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of Capacity 7.5HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of Capacity 12.5 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of Capacity 20 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only gland plates with studs/ eye bolt suitable for for centrifugal/monoblock pumping set of Capacity 40 HP pumping set of any make complete all as directed by Engineer-in-charge.
Supply only carbon steel shaft high tensile strength with key suitable for centrifugal/monoblock pumping set of Capacity 3HP Make- Kirloskar, complete all as directed by Engineer-in-charge.
Supply only carbon steel shaft high tensile strength with key suitable for centrifugal/monoblock pumping set of Capacity 5 HP Make- Kirloskar, complete all as directed by Engineer-in-charge.
Supply only carbon steel shaft high tensile strength with key suitable forcentrifugal/monoblock pumping set of Capacity 7.5HP Make- Kirloskar, complete all as directed by Engineer-in-charge.
Supply only carbon steel shaft high tensile strength with key suitable forcentrifugal/monoblock pumping set of Capacity 12.5HP Make- Kirloskar, complete all as by Engineer-in-charge.
Supply only carbon steel shaft high tensile strength with key suitable for centrifugal/monoblock pumping set of Capacity 20HP Make- Kirloskar, complete all as directed by Engineer-in-charge.
Supply only carbon steel shaft high tensile strength with key suitable for centrifugal/monoblock pumping set of Capacity 40 HP Make- Kirloskar, complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set of Capacity 3HP , Make- Kirloskar as per Sample complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set of Capacity 5HP , Make- Kirloskar as per Sample complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable forcentrifugal/monoblock pumping set of Capacity 7.5 HP , Make- Kirloskar as per Sample complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set of Capacity 12.5 HP , Make- Kirloskar as per Sample complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set of Capacity 15 HP , Make- Kirloskar as per Sample complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set of Capacity 40 HP , Make- Kirloskar as per Sample complete all as directed by Engineer-in-charge.
Supply only super enameled copper winding wire for rewinding the electric motors complete all as directed. Note :- Labour for motor winding shall be inclusive in respective items of rewinding.
Supply and fixing in repair MCCB, 63 Amp, 415 Volts, 4Pole , 50 cycle, breaking capacity 35KA complete all as directed by Engineer-in-charge.
Supply and fixing in repair MCCB, 100 Amp, 415 Volts, 4Pole , 50 cycle, breaking capacity 36 KA complete all as directed by Engineerin-charge.
Supply and fixing in repair MCCB, 125 Amp, 415 Volts, 4Pole , 50 cycle, breaking capacity 36 KA complete all as directed by Engineerin-charge.
Supply and fixing in repair MCCB, 200 Amp, 415 Volts, 4Pole , 50 cycle, breaking capacity 35KA complete all as directed by Engineerin-charge.
Supply and fixing in repair MCCB, 250 Amp, 415 Volts, 4Pole , 50 cycle, breaking capacity 36 KA complete all as directed by Engineerin-charge. Makes for serial item No. 79 to 83: HPL / HAGER / BENTEC INDIA LIMITED (BENTEC/BENLO) / LEGRAND / L&T / C&S ELECTRIC LIMITED (C&S) / BCH ELECTRIC LIMITED / UNIVERSAL SWITCH GEAR CONTROL/ POLY CAB WIRES PVT LIMITED / SCHNEIDER / MDS / HAVELLS INDIA LTD / SHALABH (INDIA) LTD (SHALABH SWITCHGEAR) / INDO ASIAN / NOVATEUR ELECTRICAL & DIGITAL SYSTEMS PVT LTD (INDOASIAN) / HPL ELECTRIC & POWER PVT LIMITED / ABB / SIEMENS.
Supply and fixing in repair ball bearing of DE & NDE for electric motor of capacity 3.0 HP 6305zz & 6308zz complete all as directed by Engineer-in-charge.
Supply and fixing in repair ball bearing of DE & NDE for electric motor of capacity 5.0 HP 6306zz complete all as directed by Engineer-in-charge.
Supply and fixing in repair ball bearing of DE & NDE for electric motor of capacity 7.5 HP 6305zz & 6308zz complete all as directed by Engineer-in-charge .
Supply and fixing in repair ball bearing of DE & NDE for electric motor of capacity 12.5 HP 6312zz complete all as directed by Engineer-in-charge.
Supply and fixing in repair ball bearing of DE & NDE for electric motor of capacity 20 HP 6309zz complete all as directed by Engineer-in-charge.
Supply and fixing in repair ball bearing of DE & NDE for electric motor of capacity 40 HP 63012zz complete all as directed by Engineer-in-charge. Make for serial item No. 84 to 89 :- SKF/NBC.
Lifting the submersible pump and motor of capacity upto 3 HP complete after disconnecting electric cable connection and transportating to civil workshop and back for repair and rewinding the submersible electric motor 3 HP by using PVC insulated copper conductor winding wire of suitable turn and gauge as per the original,reassembling the complete submersible pump and motor lowering including reconnecting the electric cable connection and testing complete all as directed by Engr-in-charge.
All as per srl item No. 90 here-in-before but submersible pump and motor of capacity 3.5 HP.
All as per srl item No. 90 here-in-before but submersible pump and motor of capacity 4.0HP.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 1.5 HP complete all as directed by Engineer-in-charge
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 3.5 HP complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 4.0 HP complete all as directed by Engineer-in-charge.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 7.5 HP complete all as directed by Engineer-in-charge.
Supply and fixing in repair Relay range of (1.6 -2.5 Amps ) for 1.5-2.0 HP starter(Dol/Star delta) complete all as directed by Engineer-in-charge.
Supply and fixing in repair fixing in repair Relay range (4.0-6.0 Amps ) for 3.0 HP starter(Dol/Star delta) ocomplete all as directed by Engineer-in-charge.
Supply and fixing in repair Relay range (5.5-8.0 Amps ) for 3.5 HP starter(Dol/Star delta) ocomplete all as directed by Engineer-in-charge.
Supply and fixing in repair Relay range (5.5-8.0 Amps ) for 4 HP starter(Dol/Star delta) ocomplete all as directed by Engineer-in-charge.
Supply and fixing in repair Relay range (5.5-8.0 Amps ) for 5 HP starter(Dol/Star delta) ocomplete all as directed by Engineer-in-charge.
Supply and fixing in repair Relay range (9.0-14.0 Amps ) for 7.5 HP starter(Dol/Star delta) ocomplete all as directed by Engineer-in-charge.
Supply and fixing in repair Relay range (14.0-22.0 Amps ) for 12.5 HP starter(Dol/Star delta) ocomplete all as directed by Engineer-in-charge.
Supply and fixing in repair Relay range (23.0-32.0Amps ) for 20 HP starter(Dol/Star delta) ocomplete all as directed by Engineer-in-charge.
Supply and fixing in repair Relay range (23.0-32.0 Amps ) for 40 HP starter(Dol/Star delta) ocomplete all as directed by Engineer-in-charge. Make for serial item No. 98 to 106: C & S/L & T/Equivalent
Supply only PVC copper winding wire as per exixting for submersible pump and motor complete all as directed.
Supply and fixing in repair Belts of suitable size B-56 for Air Blower electric motor complete all as directed by Engineer-in-charge.
Supply and fixing in replacement Belts of suitable size B-48 for Air Blower electric motor complete all as specified and as directed by Engineer-in-charge
Supply and fixing in repair Belts of suitable size B-57 for Air Blower electric motor complete all as directed by Engineer-in-charge.
Supply and fixing in repair power Contactors 415 volts ,50 cycles,3 phase, MNX-A2 complete all as directed by Engineer in-charge.
Supply and fixing in repair power Contactors 415 volts ,50 cycles,3 phase, MNX A1 complete all as directed by Engineerin-charge.
Supply and fixing in repair power Contactors 415 volts ,50 cycles,3 phase MCX 33 complete all as directed by Engineerin-charge. Make for serial item No. 111 to 113:- L & T/ Havells/ Siemens/BCH/Legrand/Indo Asian
Supply and fixing in repair ball bearing of DE/NDE 6305zz/6308zz for Air blower of capacity upto 7.5HPcomplete all as directed by Engineer-in-charge. Make :- SKF/NBC
Supply and fixing in repair ball bearing of DE/NDE 6305zz/6308zz for Air blower of capacity upto 10HP complete all as directed by Engineer-in-charge.
Supply and fixing in repair ball bearing of DE/NDE 6309zz for Air blower of capacity upto 15HP complete all as directed by Engineer-in-charge.
Supply and fixing in repair ball bearing of DE/NDE 6309zz for Air blower of capacity upto 20HP complete all as directed by Engineer-in-charge. Make for serial item No. 114 to 117: SKF/NBC.
Supply only chlorine dioxide powder (SCS 10K) chemical for treatment of raw sewage treated water complete all as directed. Make: M/S Bharti Waters Pvt. Ltd. or equivalent.
Material & labour for cleaning and preparation of old painted surface of street light steel tubular pole 9.00 mtr long and painting with one coat of aluminium paint including brackets and making alternative black & white strips on pole with two coats of synthetic enamel paint (each strip 30 cm height) upto 1.5 m height from top of PCC foundation block and numbering of poles complete all as directed by Engineer-in-charge.
Supply and fixing in repair energy efficient LED street light fitting of 60 Watt seasonal RTC control with dimmable type, includig No. of LED bulbs as per manufacturers istructions for lighting of 60 watt, epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens/ watt individual LED's should have lenses for better throw across and along road PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 10 KV minimum surge protection, short circut and over voltage protection facility for Driver and fitting complete all as specified and directed by Engineer in Charge. Make HALONIX CAT NO HLCGRFSL 1004/ WIPRO LR0260W/HPL CCMSSL60W/HAVELLS CCMSLS60W/C&S INDUS-560W/PHILIPS CCMSSL60W/CROMPTION SMARSL60W. Note:- (i) Cable for connection of LED light fitting shall be measured and paid separately under suitable item of schedule.
Supply and fixing service wire PVC insulated stranded aluminium conductor, served with inner sheating of PVC tape and overall PVC sheathed of size 2.5 Sqmm twin core flat, 1100 volts complete all as specified and directed by Engineer-in-charge.(from Junction box to fittings terminals)
Supply and fixing in repair LT cable junction box shall be insulated and made out of polycarbonate with glass fiber reinforced and size should be not less then 260x210x116 in mm the polycarbonate JB shall be environment friendly, recyclable, helogen & silicon free anti acid & anti corrosive the JB shall be rated for degree of ingress protection IP 66 in accordance with IEC 60529. The gasket material shall be polyurethane and the gasket shall be internally embedded the JBs shall be complies with requirement of the stedarda IEC 60998, IEC 60670.22 & IEC 60670 2.5 the JB colour according to RAL 9011. The manufacturer of JB/ Enclosure shall submit a copy of IEC certificate for better safety the Polycarbonate encl shall be fire reterdant & extinguishing in accordance with IEC 60695-211 DIN VDE 0304 Part 3, UL subject 94 for flammablity V-2 it should be tested at Glove Wire test for 960 deg cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298 for IK 08 including 4 Pole connector MCB SP 'C' curved 2.5 A and cromium plated clamps and nut bolts complete. Note: Manufacturer should submit routine test certificate for CJB/PJB. Make: Hensel, Cat Part K 9350 / Siemens/ GE Power/ Rittal.
Supply only pebbles 40-25 mm - As per site requirement. Pebbles 12-6 mm-1050 kg , Crushed Gravel 10.3 mm -1000Kg, Crushed Gravel 6.2 mm-950 Kg, Fine filterate-3050 Kg & Antracite 0.6 -0.8 mm-2250 Kg for Dual Media Filter (DMF) Complete all as directed by Engineer-in-charge.( At Jaduath STP Pocket No:09)
Supply only pebbles 40-25 mm - As per site requirement, crushed Gravel 10.3 mm-1050 Kg Fine filterate,antracite 16/32 mm-850 Kg & Activate carbon-5000 Kg For Activated carbon Filter (ACF) Complete all as directed by Engineer-in-charge.( At Jaduath STP Pocket No:09)
M/S KIRT ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .