Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹50.6 L+₹5.1 L (11.3%)Rejected-Finance PURAMUFTI NEAR GURUDWARA G T ROAD ALLAHABAD UTTAR PRADESH 212208 | PRAYAGRAJ | UTTAR PRADESH | 212208 | L2 | Rejected-Finance Being L2 |
| Sl No | Description | Qty | Unit | vs construction L1 | NSA ENGINEERING WORKS L2 |
|---|---|---|---|---|---|
| 1.00 | M&L for prepainted coloured galvaniume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile stregnth of 550 mpa as in roof covering and cladding to wall fixed with self tapping screws complete all as specified and directed. | 220 | Sqm | 750 ₹1,65,000 | 700 ₹1,54,000 Lowest |
| 2.00 | M&L for prepainted coloured galvaniume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to roof wall, fixed with self tapping screws as specified | 22 | Sqm | 750 ₹16,500 | 600 ₹13,200 Lowest |
| 3.00 | M&L for structural steel work using rolled mild steel of grade Fe 410-W(Gde-E- 250)quality-A as in roof trusses (framed and trussed), purlins, crane gantries, rails and fastenings, heavy bracket framing (made from beam, tee, angle, channel or flat sections), including distance pieces, cleats, gusset plates etc., cut to required lengths, hoisted, fixed in position, including welding, bolting or riveting as required complete all as specified and directed. | 3,800 | Kg | 110 ₹4,18,000 | 100 ₹3,80,000 Lowest |
| 4.00 | M&L for two coats of synthetic enamel painting on new steel surfaces over a coat of red oxide primer including preparation of surfaces of any description over 10cm girth or width not other wise described complete all as specified and directed. | 50 | Sqm | 100 ₹5,000 | 80 ₹4,000 Lowest |
| 5.00 | Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc.complete all as specified and directed. | 9.5 | Cum | 500 ₹4,750 | 200 ₹1,900 Lowest |
| 6.00 | M&L for Brick work with fly ash (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6.complete all as specified and directd. | 9.5 | Cum | 5,000 ₹47,500 Lowest | 6,000 ₹57,000 |
| 7.00 | M&L PCC 1:4:8 Type D2 (using 40mm graded stone aggregate) in foundation ,fillings and mass concrete complete all as specified and directed. | 0.75 | Cum | 6,000 ₹4,500 | 4,500 ₹3,375 Lowest |
| 8.00 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. | 175 | Sqm | 50 ₹8,750 | 10 ₹1,750 Lowest |
| 9.00 | M&L for rendering 5 mm thick on ceiling surfaces in cement mortar 1:3 finisheing the surface even & fair complete all as specified and directed. | 50 | Sqm | 150 ₹7,500 Lowest | 180 ₹9,000 |
| 10.00 | M&L for rendering 15 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:6 finishing the surface even and smooth without using extra cement complete all as specified and directed. | 170 | Sqm | 140 ₹23,800 Lowest | 160 ₹27,200 |
Tender Value
₹47.8 L
EMD Value
₹95,700
Closing Date
24 Oct 2025, 6:00 pmClosed
Garrison Engineer (East) Prayagraj
Stanley Road, Teliyarganj, Prayagraj
SPL REPAIR TO BLDG AT AKSHAY VIHAR AND TOILET BLOCKS AT OFFICER MESS AND ISO OFFICE AT OD FORT CANTT AND SPL REPAIR/REPLACEMENT OF FANS AND STABILIZERS AGAINST BER AT OLD CANTT PRAYAGRAJ.
2025_MES_732867_1
8816/E8
Open Tender
Civil Works
Item Rate
120 days
Prayagraj
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE (East) Prayagraj
₹95,700
Yes
20 Jan 2026
26 Sept 2025
29 Oct 2025
26 Sept 2025
24 Oct 2025
10 Oct 2025
26 Sept 2025 - 3 Oct 2025
Amount
M&L for prepainted coloured galvaniume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile stregnth of 550 mpa as in roof covering and cladding to wall fixed with self tapping screws complete all as specified and directed.
M&L for prepainted coloured galvaniume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to roof wall, fixed with self tapping screws as specified
M&L for structural steel work using rolled mild steel of grade Fe 410-W(Gde-E- 250)quality-A as in roof trusses (framed and trussed), purlins, crane gantries, rails and fastenings, heavy bracket framing (made from beam, tee, angle, channel or flat sections), including distance pieces, cleats, gusset plates etc., cut to required lengths, hoisted, fixed in position, including welding, bolting or riveting as required complete all as specified and directed.
M&L for two coats of synthetic enamel painting on new steel surfaces over a coat of red oxide primer including preparation of surfaces of any description over 10cm girth or width not other wise described complete all as specified and directed.
Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc.complete all as specified and directed.
M&L for Brick work with fly ash (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6.complete all as specified and directd.
M&L PCC 1:4:8 Type D2 (using 40mm graded stone aggregate) in foundation ,fillings and mass concrete complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for rendering 5 mm thick on ceiling surfaces in cement mortar 1:3 finisheing the surface even & fair complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:6 finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound finishing the surface even and smooth without using extra cement complete all as specified and directed. Note: (i) Water proofing compound shall be mixed @ 200ml per 50Kg cement (min) or as per manufecturer's specification. WPC shall be measured & paid seprately under respective item here-in-under as 'SUPPLY ONLY'. (ii) The unit rates quoted shall be applicable for exicution of work up to 10m height and deemed included cost of all T&P ,scafolding and all safety precaution (i.e. Safety Jacket, Safety Shoes, Safety Masks, Safety Helmet, Safety harness, Safety Goggles etc) required for smooth exicution of work. Without safety precaution this work will not be allow to commence.
Supply only liquid integral crystalline water proofing compound complete all as specified and directed.
M&L for applying two coat of oil bound distemper on ceiling surface over a coat of primer including preparation of new plastered surface and complete all as specified and directed.
M&L for applying two coats of distemper oil emulsion over one coat of 1mm thick birla white putty and one priming coat including preparation of newly plastered wall surfaces complete all as specified and directed.
M&L for complete removal of existing treatment on wall/roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit), make surface clean, free from dust, loose paint etc complete all as specified and directed.
M&L for applying two coats of weather proof paint over one coat of 1mm thick birla white putty and one priming coat including preparation of newly plastered wall surfaces complete all as specified and directed. Note : Cost of applying one 1mm thick putty and primer coat deemed included in quoted rates.
M&L for applying two coat of oil bound distemper on ceiling over one coat of 1mm thick birla white putty and one priming coat including preparation of newly plastered ceiling surfaces complete all as specified and directed.
M&L for applying one coat of oil bound distemper on old treated walls surfaces including preparation of surface by required screping, filling drpessions, with wall care putty, removing nails etc complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:3:6, type C-1 (using 20 mm graded graded stone aggregate) in plinth protection, finished suface even and smooth witht using extra cement complete all as specified and directed.
Taking down Chowkats or frames, area of opening n'exc 1.5 Sqm each (without taking off shutters from the frame) complete all as specified and directed.
Taking down Chowkats or frames, area of opening exc 1.5 Sqm but n'exc 1.5 Sqm each (without taking off shutters from the frame) complete all as specified and directed.
M&L for providing and fixing factory made UPVC Sliding window (Three track white colour), area n'exc 2.0Sqm each, made of extruded profiles with wall thickness of 2.3 mm ( + 0.2mm) including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2+ 0.2mm thick, Touch Lock of zinc alloyed (white powder coated), roller system, wire cloth and/or plain glass in penal of shutters, fixed to the wall with 8mm x 100mm long fasteners complete all as specified and directed. Note: Window profile shall be hollow section with multi chamber. All sections shall be miterd cut and fusion welded at all corners. Size of profiles/ sections shall be as under :- (i) Frame - 88mm x 52mm duly inserted galvanised steel section having size 30mm x 18mm -2 nos, (ii) Sliding sash - 42mm x 67mm duly inserted galvanised steel section having size 30mm x 18mm (iii) Sliding mesh Sash - 42mm x 57mm , duly inserted galvanised steel section having size 26mm x 10mm (iv) Sliding interlock (One vertical length in each shutters-45.5mm x 28mm), (v) Glazing bead - 24.5mm x 16mm . (vi) The unit rate quoted by contractor excludes cost of glass and wire cloth but includes all other connected accessories. Net Opening will be measured for payment purpose.
M&L for providing and applying approved quality weather proof silicone sealant around the perimeter of UPVC window frames (internal and external sides) to seal the gap between frame and masonry/plaster surface, masking, and cleaning, complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F 5.5 mm thick plain sheet glass as in,shutters with and including rubber gasket and natural colour anodized aluminium snap beading/glazing, clips etc complete all as specified and directed.
S&F stainless steel wire mesh, 0.56mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed.
taking down drapery rod including bracket and cap, any discription and pattern complete all as specified and directed.
S&F 25 mm dia stainless steel drapery rod cut to size and fixed in position including brackets, cap both ends fixed to wall complete all as directed. Note : Drapery rod for each door/window/ventilator/opening shall contain one pair breacket and one cap on ceach side. Brakets and caps shall be strictly as per sample kept in GE's office.
S&F factory made single extruded WPC (Wood Polymer Composite) solid Frames/ Chowkhat for door/ window/ Ceosetory windows etc of size 100 x 50 mm, fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. NOTE : (i) The WPC shall comprising of virgin PVC polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms). (ii) The frame shall fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws. (iii) The WPC shall have minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant. (iv) The cost of M.S. hold fast/ lugs or SS dash fasteners shall deemed included in quoted unit rate. Each frame shall be fixed with min 06x holdfasts/ faster's.
All as per item No. 30 above but Frames/ Chowkhat of size 125 x 65 mm.
All as per item No. 30 above but Frames/ Chowkhat of size 45 x 70 mm
M&L for providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick and fixed with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws compete all as specified and directed Note : (i) WPC shall comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistureproof and fire retardant. (ii) WPCshall be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter. (iii) stainless steel butt hinges and necessary S.S screws shall be paid separately
All as per Item No.33 but 35mm thick shutter.
S&F 30mm thick plain WPC factory made glazed Skeleton door shutters (conforming as per IS-4020) having density not less than 600 Kg/cum, water prrof, termite proof, fire retardant and screw holding capacity. Door should be fixed with SS hinges and SS screws and panelled with Stainless steel mosquito mesh and XTN aluminium mesh for additional strength and safety purposeComplete all as specified and directed. Note- Stainless steel wire mesh and SS hinges shall be measured and paid separately.
S&F 150mm long SS handles, complete all as specified and directed.
S&F 200mm long SS barrel tower bolts complete all as specified and directed.
S&F 250 mm long SS sliding door bolt with hasp, staple (bolt type) and fixing clips complete all as specified and directed.
S&F 100 mm long SS butt hinges, complete all as specified and directed
S&F 300 mm long, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed
S&F 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed
Taking down Shutter of area exceeding 1.0 Sqm but n'exc 2.00 Sqm each complete all as specified and directed.
Taking down Shutter exceeding 2.0 Sqm each complete all as specified and directed.
S&F 150 mm Hasp and staple, stainless steel, wire type, including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F 50mm magnetic catches for cabinets with striking plate & magnetic stud as per sample kept in GE's offce and as approved complete all as specified and directed.
S&F 30mm wide stainless steel continuous (piano) hinges complete all as specified and directed.
M&L for 40 mm dia CP brass cuboard knobs fixed with nuts ,screws and washers, bright polished complete all as specified and directed.
M&L for providing and fixing 18mm thick factory made single extruded WPC (Wood Polymer Composite) solid board shutters for cup boards, work stations and bathroom/kitchen cabinet etc, one side white color and other side laminted fixed with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. Note : (i) WPC shall comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistureproof and fire retardant. (ii) WPCshall be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter. (iii) stainless steel butt hinges and necessary S.S screws shall be paid separately
M&L for providing and fixing 12 mm thick factory made single extruded WPC (Wood Polymer composite) solid plain both side white color board for backing of cup boards and bathroom/kitchen cabinets etc. with stainless steel screws etc. complete all as specified and directed Note : WPC shall comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistureproof and fire retardant.
M&L for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n'exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick cement mortar screed bed or bedding layer (1:4) for laying floor finishes complete all as specified and directed.
M&L for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.18 sqm but n'exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick cement mortar screed bed or bedding layer (1:4) for laying floor finishes complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including10mm thick plaster in cm 1:4 complete all as specified and directed.
M&L for heavy duty out door coloured ceramic tiles, area of each tile exc 0.11 sqm but n'exc 0.18 sqm, 12 mm thick, set and jointed in neat cement slurry & pointed with coloured cement to match in floor over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.laid bedded and pointed in any mortar including removing of rubish out side of MOD area complete all as specified and directed.
M&L for Baroda green marble 14 to 16 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed. Note : cost of screed bed deemed included in quoted unit rates.
M&L for rounding to one edge of stone slabs as in steps, cooking platform, and other similar situations etc complete all as specified and directed.
Taking down existing sink of any type, size and discription including it's assesories complete all as specified and directed.
S&F sinks without drainage board made of stainless steel 1.0 mm thick (kitchen or laboratory type) of overall size: 495 mm × 420 mm; bowl size: 410 mm × 330 mm × 160 mm, with plugs, washers and wastes; including bedding in cement mortar on / to dwarf wall or fixing with cantilever brackets, connecting union to pipe, PVC waste pipe , uPVC bottle trap, complete all as specified and directed
Taking up or down 15mm bore pipe water tubing and connection including cleaning for refixing or removal to store, any discription complete all as specified and directed
M&L for providing PP-R (Polypropylene Random Copolymer) pipe, 20 mm bore (outer dia), PN 16, three-layer construction, conforming to IS:15801, UV-stabilized and anti-microbial, fusion welded type, having thermal stability suitable for hot and cold water supply systems, fixed to walls and ceilings or laid in floors including all PP-R plain and brass-threaded fittings, complete all as specified and directed. Note : The pipe shall be fixed with suitable clamps at 1.00 metre spacing, and all joints shall be tested for leak-proofness to the satisfaction of the Engineer-in-Charge.The cost of the same shall be deemed included in unit quoted rate.
Taking up or down 15/20mm bore pipe water tubing and connection including cleaning for refixing or removal to store, any discription complete all as specified and directed
M&L for providing PP-R (Polypropylene Random Copolymer) pipe, 25 mm bore (outer dia), PN 16, three-layer construction, conforming to IS:15801, UV-stabilized and anti-microbial, fusion welded type, having thermal stability suitable for hot and cold water supply systems, fixed to walls and ceilings or laid in floors including all PP-R plain and brass-threaded fittings, complete all as specified and directed. Note : The pipe shall be fixed with suitable clamps at 1.00 metre spacing, and all joints shall be tested for leak-proofness to the satisfaction of the Engineer-in-Charge.The cost of the same shall be deemed included in unit quoted rate.
M&L for Cutting chases, pinning in brick walls not exc 10 cm girth, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc.complete all as specified.
S&F 1000 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed.
Dismantling water tanks exc 500 ltr but n'exc 1000 Ltrs capicity, any type and discription including removing from site complete all as specified and directed.
S&F PP-R Gate valves (brass insert), 20mm outer dia complete all as specified and directed.
S&F PP-R Gate valves (brass insert), 25mm outer dia complete all as specified and directed.
Taking down sanitary fittings like WHB/WC/Fushing cistern/ Urinal etc including all fitting and fixtures, any discription, size, type nd pattern including removing from site complete all as specified and directed.
S&F vitreous china wash hand basin with pedestal pattern, white, flat back, size 550 x 400 mm, excluding taps, waste chain and plug, but including bracket, 32 mm waste coupling, and flexible PVC waste pipe, complete all as specified and directed.
S&F Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including setting the trap and pan in concrete, complete all as specified and directed.
S&F 10 ltrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, aluminium brackets for bottom support fixing with gitties embeded in wall etc complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F 110 mm dia UPVC (SWR) bends any radius with oval access door complete all as specified and directed.
S&F 75 mm dia UPVC (SWR) bends any radius complete all as specified and directed.
S&F 110 mm dia UPVC (SWR) branch piece, (double Y) equal or unequal complete all as specified and directed.
S&F 75 mm dia UPVC (SWR) branch piece, (double Y) equal or unequal complete all as specified and directed.
S&F 75 mm dia UPVC (SWR) bends with access door any radius complete all as specified and directed.
S&F 110 mm dia UPVC(SWR) plain bends any radius complete all as specified and directed.
S&F 75 mm dia UPVC (SWR) pipes TYPE -B Conforming to IS 13592 single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 75 mm dia UPVC (SWR) pipes TYPE -B Conforming to IS 13592 single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F UPVC (SWR) 110 mm dia pipes TYPE -B Conforming to IS 13592 single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F UPVC (SWR) 110 mm dia pipes TYPE -B Conforming to IS 13592 single socketed, in any length with rubber ring joints, fixed on walls complete all as specified and directed.
Taking down 75/110mm dia pipes,including all fitting and fixtures, any discription, size and type and removing from site complete all as specified and directed.
Demolition of plain cement concrete(unreinforced), any description and in any position not otherwise specifically provided for as in sunken floor etc. complete all as specified and directed. Note : This item includes demolition of floor top (tiles etc) surface and all metrial undernith (up to top concrete surface of sunken floor/roof) like screed, subbase, lean concrete or filling meterial etc.
M&L for PCC 1:7:12 type F2 (using 40 mm graded stone aggregate) as in filling into sunken floor complete all as specfied and directed.
M&L for providing plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) in required thickness as in sub base for floor or pedding (for making concrete surface smooth before application of WPT layer), kerb etc complete all as specified and directed. Note : The thickness of concrete shall be decided by Engg-in-charge as per site reqirment. If mixing of liquid water proofing compound is ordered, the same shall be measured and paid seperatly. No extra payment shall be made for mixing the same.
M & L for Providing 25 mm thick, cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate in flooring in sunken slab complete all as specified and directed.
M&L for Treatment to sunken floor and sides as mentioned here after:- (Step-I) Cleaning of RCC surface to remove existing treatment to sides and base slab by using sand blasting with compressed air. (Step-II) M&L application of a coat to sides and base of sunken with glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal -107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika Fab-I and top coat with Sika Seal-107@ 1.50 Kg/Sqm or equivalent of Forsoc or pidilite. (Step-III) M&L 15 mm thick cement plaster on side and base slab of sunken part in cement mortar 1:3 mixed with appropriate integral water proofing compound with Sika Plastocree plus as specified. (Step-IV) M&L applying evenly a tack coat of industrial bitumen 85/25 @ 1.20 Kg/Sqm on plastered surface of sunken sides & base. Note:All debris obtained from site will be thrown away out side Def Land by contractor at his own expense.
Taking down plumbing fittings like bib tap/stop cock/ mixture/piller tap/health fausit// shower/looking mirror/cabinate mirror/plat rack/glass self/ peg stay/ soap dish/ towel rail etc, any disctiption type and pattern complete all as specified and directed.
S&F 15 mm bore bib taps cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete all as specified and directed. Make: Cat pat No. OPP-SSF-15037PM of Jaquar or eqiuvalent of grohe or Kohlar
S&F Sink Mixer with Swinging Spout (Wall Mounted Model) with Connecting Legs & Wall Flanges, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed both end for iron pipes complete all as specified and directed. Make: Cat pat No. CQT-CHR-23309 of Jaquar or eqiuvalent of grohe or Kohlar
S&F 15 mm size angular cock, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed both end for iron pipes complete all as specified and directed. Make: Cat pat No. OPP-SSF-15053PM of Jaquar or eqiuvalent of grohe or Kohlar
S&F angle cock, 2 way, with wall flange 15 mm dia cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed both end for iron pipes complete all as specified and directed. Make: Jaquar or eqiuvalent of grohe or Kohlar
S&F central hole basin mixer for WHB cast copper alloy with capstin heads chromimium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed shank and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and directed. Make: Cat pat No. CQT-CHR-23167B of Jaquar or eqiuvalent of grohe or Kohlar
S&F Health faucet (Hand shower) with 1 metre flexible tube and wall hook, chromium plated complete all as specified and directed. Make: Cat pat No. ALD-CHR-573 of Jaquar or eqiuvalent of grohe or Kohlar
S&F Overhead Rain shower SS 100 mm dia (4") with 200 mm (8") long shower arm and wall flange complete all as specified and directed. Make: Cat pat No. F7020109SS of CERA or eqiuvalent of grohe or Kohlar or Jaquarr
S&F Stailness steel plate rack of size 910mm x 780mm x 250mm (31'' x 36 " 10") with separators and 3 tier shelves, made out of 1.00mm thick stailness steel sheet of grade AI SI 304 including fixing arrangment complete all as specified and directed.
S&F 250 mm size mild steel peg stay of primium quality (as per sample kept in GE office) fixed to wall/ doors complete all as specified and directed.
S&F 15 mm bore stop valve fancy type chromium plated with long cup and shank (Concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed Make: Cat pat No. CAN-CHR-1185 of Jaquar or eqiuvalent of grohe or Kohlar
S&F polished black granite inauguration plate of size 600mm x 900mm x 18-20mm thick, with machine-cut edges, mirror finish, and engraving of text/logo as per approved design including gold paint filling in letters, fixing with stainless steel clamps and necessary adhesive, complete complete all as specified and directed.
S&F Cabinet Mirror PTMT 450 x 555 mm with sided shelves fancy type of with bracket and fittings (as per sample kept in GE office) fixed to wall complete complete all as specified and directed.
S&F corner glass shelf superior quality matt finished crromium plated (MCH/Colour CP ) with bracket and fittings (as per sample kept in GE office) fixed to wall complete all as specified and directed. Make: Cat pat No. ACN-CHR-1173 of Jaquar or eqiuvalent of grohe or Kohlar
S&F glass shelf matt finished chromium plated (MCH/Colour CP) with bracket and fittings (as per sample kept in GE office) fixed to wall complete all as specified and Make: Cat pat No. CAN-CHR-1171N of Jaquar or eqiuvalent of grohe or Kohlar
S&F Tubler towel rail 600mm Long, chromium plated, including brackets fixed to wall with stainless steel screws, complete all as specified and directed. Make: Cat pat No. CAN-CHR-35711PS of Jaquar or eqiuvalent of grohe or Kohlar
S&F SS soap dish primium quality (as per sample kept in GE office) fixed to wall/ doors complete all as specified and directed. Make: Cat pat No. AQN-CHR-7731 of Jaquar or eqiuvalent of grohe or Kohlar
S&F 75 mm dia UPVC floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/slabs/blankets/AC boards etc any thickness complete all as specified and directed.
M&L for providing false ceiling using non asbestos fiber cement ceiling board of size 600x600x6mm and Aluminium snap grid frame complete all as specified and directed Frame Work: (i) Aluminum angle of size 25x25mm screwed fixed to the parameter of the wall at a level/height as directed by Engineer-in-charge. (ii) Main ‘T’ runners: Aluminum sections (3600mm long) with ‘H’ slots at 150mm/300mm center in its vertical flange to hold the cross ‘T’ sections are suspended from the soffits with the help of rawl plug, soffits cleats and GI wire (4mm dia & up to 12mm length) at 1200mm c/c. These sections also have notch at it's both ends to increase the length. (iii) Cross ‘T’ runner: Aluminum sections of 1200mm length with ‘H’ slot in the center and notches at the both ends are inserted fixed into the main ‘T’ at 600mm c/c to form a regular grid of 600x1200mm cross ‘T’ section of 600mm length is inserted fixed into the 1200mm cross ‘T’ to form a regular grid of 600 x 600mm. Note : The cost of ceiling board,aluminum frame/grid, suspended wire and reqired fixing meterial shall deemed included in the unit quoted rates.
M&L for applying two coat of oil bound distemper on wall over one coat of 1mm thick birla white putty and one priming coat including preparation of new or old (compltly removed existing treatment) plastered surfaces complete all as specified and directed.
M&L for powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions/ frame) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed. Note : Only standard weight of aluminum sections used shall be measured for payment perpose.The cost of EPDM rubber/ neoprene gasket, snap beading, dash fasteners, screws etc shall deemed included in unit quoted rates.
M&L for powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed. Note : Only standard weight of aluminum sections used shall be measured for payment perpose.The cost of EPDM rubber/ neoprene gasket, snap beading, dash fasteners, screws etc shall deemed included in unit quoted rates.
S&F stainless steel Auto closing hinge, 35mm long, 'O' crank (KH-001) or '8' crance (KH-002), operable at 110 degree for kitchen/ cabinate shutters complete all as specified and directed
M&L for dark shade matt finished double charged vetrified tiles, 10mm thick, (square/ rectangular) area of each tile exc 0.36 sqm but n'exc 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick cement mortar screed bed or bedding layer (1:4) for laying floor finishes complete all as specified and directed.
M&L for Glazed matte finished ceramic tiles, 10mm thick, (square/ rectangular) area of each tile exc 0.36 sqm but n'exc 0.42 sqmin in vertical surface, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including10mm thick plaster in CM 1:4 complete all as specified and directed.
S&F under counter wash han basin with fixing accessories, sise 450x450x170mm, round shape, white in clour, excluding taps but including waste pipe, coupling etc complete all as specified and directed. Make: Cat pat No. LAS-WHT-91707 of Jaquar or eqiuvalent of grohe or Kohlar
S&F rimless single piece WC with UF sift close seat cover, hinge, dual flush flushing cistern including fixing accessories, 'P' trap, size 395x710x730mm, white in clour complete all as specified and directed. Make: Cat pat No. VGS-WHT-81853P180UF of Jaquar or eqiuvalent of grohe or Kohlar
S&F vitreous China urinal with sensor kit, speader and fixing accessories, size 360x350x710mm, white in colour complete all as specified and directed. Make: Cat pat No. URS-WHT-1267S of Jaquar or eqiuvalent of grohe or Kohlar
S&F 15 mm dia bib taps(long body) cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete all as specified & directed. Make: Cat pat No. FUS-CHR-29037 of Jaquar or eqiuvalent of grohe or Kohlar
S&F single lever basin mixer without Popup system with 450mm long braided hose pipe cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for 15mm bore iron pipes complete all as specified & directed. Make: Cat pat No. SOL-CHR-6001B of Jaquar or eqiuvalent of grohe or Kohlar
S&F toilet paper holder with flap, recessed type, chromium plated complete all as specified & directed. Make: Cat pat No. ACN-CHR-1135S of Jaquar or eqiuvalent of grohe or Kohlar
S&F Towel ring square with round flange, chromium plated complete all as specified & directed. Make: Cat pat No. AKP-CHR-1121 of Jaquar or eqiuvalent of grohe or Kohlar
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for point wiring for one light point/ fan point/ exhaust fan point controlled by one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed conduit, including non metallic PVC conduit of apropriate size (not less than 20 mm dia) with all accessories, fitting and fixtures, factory made ressessed terminal boxes of reqd size (made of pressed steel sheet not less than 1.6 mm thick) duly painted with two coats of block bituminous paint over a coat of red oxide primer (both side), top cover made of 3 mm thick Phenolic laminated sheet, earthing cable of same discription to common earth drawn in same conduit connected to earth dolly and making good disturbed surfaces and finished to match with existing complete all as specified and directed.
All as per item No 124 above but for One bell point controlled by one 5 Amps bell switch.
All as per item No 124 above but for One 5 amp socket outlet point on same board.
All as per item No 124 above for One 5 amp socket outlet point on an independent board.
All as per item No 124 above but for One 15 Amp socket outlet on Independant board with 2.5 sqmm (nominal area) cable.
S&F switch piano, flush butten, single pole one way 5 Amps 240 Volt complete all as specified and directed.
S&F switch piano fiush button single pole one way 15 Amp 240 volt complete all as specified and directed.
S&F Bell switch, piano type single pole one way 5 Amp complete all as specified and directed
S&F socket 5 amps 5 pin flush type , 230 volts complete all as specified and directed
S&F socket 15 amps 6 pin flush type , 230 volts complete all as specified and directed
S&F ceiling rose three terminals/PVC/ polycarbonate, isolated body complete all as specified and directed .
S&F calling bell ding dong type, AC 230 volts single pole complete all as specified and directed.
Taking down existing light fittings any discription, type, capicity and in any location including disconnection of all electric connection complete all as specified and directed.
S&F LED tube light fitting 1 x 20 watt, decorative , ultra slim round profile LED lighting fixture with co extruded polycarbonate body, environmental friendly , energy efficient complete with all accessories, prewired and making connection with and including 23/0.0076 flexible three core copper cabel (from connector to ceiling rose) not more than 1.2 mtr, fixed on wall firmly complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including making connection with and including 23/0.0076 flexible three core copper cabel (from connector to ceiling rose) not more than 1.2 mtr, complete all as specified and directed.
S&F lamp holder insulated body PVC/ Polycabonate type with back plate suitable for batten/ angular/pendent holder fittings including9Watt LED lamp/bulb complete all as specified and directed
S&F wall mounting light fitting polycarbonate body, decorative type unbreakable with LED lamp 9 Watt and making connection complete all as specified and directed.
S&F electronic fan regulator, step type hum free suitable to control speed of fan from 0 to 100% complete all as specified and directed.
Taking down existing Distribution boards (with MCB/MCCB/isolators etc), any discription, type and capicity including disconnection of all electric connection complete all as specified and directed.
S&F sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket and 1x 20Amp SP MCB complete all as specified and directed.
S&F sheet metal enclosure (distribution board), double door, single pole & neutral (SPN), 8 way 240 volt with appropriate size bus bar and neutral link having IP-43 IK-09 protection, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F MCB single pole(SP), 240 volt any rating from 6 to 32 amps , with rupturing capacity 10 KA, 'B' curve complete all as specified and directed.
S&F MCB single pole and nutral (SPN), 240 volt any rating from 6 to 32 amps , with rupturing capacity 10 KA, 'B' Curve complete all as specified and directed.
Taking down submain wiring, any disctption, size , in any location complete all as specified and directed.
M&L for sub main wiring with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable and 1 run of same discription cable as earth continuity conductor, drawn into existing conduit including necessary electric connecions and making good disturbed surfaces to match with existing complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor shall be measured as one unit length.
Taking down carefully ceiling fan/ exhaust fan/ gyser etc by disconnecting all electrical connection, painting with one coat of synthetic enamel paint and marking MES number and keeping in MES store/safe costody for reuse in the same work or in other work complete all as specified and directed.
Fixing only ceiling fan/ exhaust fan/ including electric connection with 23/0.0076 size faxible copper conductor 3 core cable complete all as specified and directed. Note : (i) ceiling fan/ exhaust fans obtained from item No. 100 above shall be used. (ii) Cost of flaxible cable deemed included in the unit quoted rates.
S&F BLDC ceiling fans of 1200 mm sweep 230 V complete with blades, down rods, electronic regulator and accessories, having minimum air delivery 210 CFM with service value 6.00 BEE. Five star rated complete all as specified and directed.
S&F electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories complete all as specified and directed.
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F GI pipe bracket on wall/pole suitable for fixing lightfittings, made of light grade GI pipe (25 to 40 mmdia), not less than 1.2 m long, bent to shape and fixed with necessary MS nuts, bolts and washers complete all as specified and directed.
M&L for earthing complete with steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron, steel earthwire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit made from PCC (1:2:4) type B-1(using 20mm graded stone aggregates) with 17mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 02 No and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom, 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 17mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in loose/ soft soil, ( excavation, returning filling in and removal of surplus soil to a distance not exceeding 50 metres), all as per electrical plate No.5 of SSR Part-I connected to earth test point all as specified or indicated including testing on complete all as specified and directed.
M&L for supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out soft loose soil complete all as specified and directed.
Returning filling in soft / loose soil including spreading leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated material (soil), n'exc 50m and depositing where directed at a level n' exc 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning to underground cable, provided in two layers i.e. 8cm before laying cable and 15cm after laying the cable complete all as specified and directed. Note: Punned thickness of sand shall be measured for payment perpose.
M&L for supply and laying old size sub class ‘B’ bricks, laid flat with width equal to length of brick (perpendicilar to cable) as cable cover complete all as specified and directed.
S&F 300mm sweep exhaust fan/ air ciculation fan made of sturdy Engineering plastic complete with louvers shutter,230V, 50 Hz, RPM 1200, copper winding complete all as specified and directed.
M&L for Cutting holes into or through brick walls brick walls built, in cement mortar or cement lime mortar, superficial area of hole exc 150 sq. cm but but n exc 400 Sqcm suitable for 300mm dia exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required, complete all as specified and directed.
Contd/... (vi) MCCB two pole 63 Amp, 415 volts AC 50 Hz, breaking capacity 25 KA, fixed magnetic and adjustable thermal releasetype - 04 No. (vii) Energy meter - 04 nos (viii) Name slip holder on each compartment for identification of Accn - 04 Nos (ix) Earthing terminals - 01 Nos (x) MCB SPN 20A 10 KA 'B' curve - 01 Nos
M&L for point wiring for one light point/ fan point/ exhaust fan point controlled by one modular switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed conduit, including non metallic PVC conduit of apropriate size (not less than 20 mm dia) with all accessories, fitting and fixtures, factory made ressessed modular terminal boxes of reqd size (made of pressed steel sheet not less than 1.6 mm thick) duly painted with two coats of block bituminous paint over a coat of red oxide primer (both side), cover plate with frame of required modules, earthing cable of same discription to common earth drawn in same conduit connected to earth dolly and making good disturbed surfaces and finished to match with existing complete all as specified and directed.
All as per item No 165 above but for One 5 amp socket outlet point on same board.
All as per item No 165 above for One 5 amp socket outlet point on an independent board.
All as per item No 165 above but for One 15 Amp socket outlet on Independant board with 2.5 sqmm (nominal area) cable.
S&F Modular switch, flush butten, single pole one way 6 Amps 240 Volt complete all as specified and directed.
S&F Modular socket outlet 6 Amps 3 pin flush type , 230 volts complete all as specified and directed
S&F Modular switch fiush button single pole one way 15 Amp 240 volt complete all as specified and directed.
S&F Modular socket 15 amps 6 pin flush type , 230 volts complete all as specified and directed
S&F sheet metal enclosure (distribution board), double door, single pole & neutral (SPN), 4 way 240 volt with appropriate size bus bar and neutral link having IP-43 IK-09 protection, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F 2'x2' CRCA LED deep drawn panel recess mounting luminaries suitable for grid/pop ceiling complete with separate electronic driver and high brightness SMD LEDs complete all as specified and directed
S&F wall fan, AC sinle phase, 230V, 400mm sweep wth blades including electric connections complete all as specified and directed
S&F automatic Voltage stablizer, single phase aircooled indoor type & designed for input variation 130 to 280V and Voltage stablized at 230V with acuracy of + 2.5% of capacity 4/5 KVA copper wound complete all as specified and directed.
NSA ENGINEERING WORKS (BID ID -3453193)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tender.pdf
Tender Documents • 1.57 MB
BOQ_820555.xls
BOQ • 1.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .