Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.5 Cr | L1 | Accepted-AOC Accepted being lowest |
| 2 | L2₹1.5 Cr+₹4.5 L (3.03%)Rejected-Finance SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.5 Cr+₹4.5 L (3.03%) | L2 | Rejected-Finance Rejected being other than lowest |
| 3 | L3₹1.6 Cr+₹14.1 L (9.48%)Rejected-Finance | ₹1.6 Cr+₹14.1 L (9.48%) | L3 | Rejected-Finance Rejected being other than lowest |
| 4 | L4₹1.6 Cr+₹15.1 L (10.1%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹1.6 Cr+₹15.1 L (10.1%) | L4 | Rejected-Finance Rejected being other than lowest |
| 5 | L5₹1.7 Cr+₹16.1 L (10.8%)Rejected-Finance | ₹1.7 Cr+₹16.1 L (10.8%) | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹1.7 Cr
EMD Value
₹2.5 L
Closing Date
18 Apr 2023, 6:00 pmClosed
Cheif Engineer Pathankot Zone
HQ Cheif Engineer Pathankot Zone Pathankot
ADDN ALTN TO MD ACCN OF SHIVALIK ENCLAVE AND DHAULADHAR ENCLAVE UNDER GE NORTH MAMUN
2023_MES_581301_1
CA NO CEPZ-28/2022-23
Open Tender
Civil Works
Item Rate
365 days
Mamun Pathankot
Class B Category a(i)
7 documents required · 7 mandatory
₹1,000
GE North Mamun
₹2.5 L
22 Jul 2023
16 Feb 2023
25 Apr 2023
17 Feb 2023
18 Apr 2023
11 Apr 2023
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each work and removing from the site of work complete all as specified and as directed by Engr-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site of work complete all as specified and as directed by Engr-in-Charge.
Taking down shutters of any description exc 1 Sqm and n exc 2 Sqm each including refixing in same opening after easing and adjusting complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work built in cement mortar including all quoins arches pillars etc but excluding ashlar facing dressed stone work & precast concrete article and removing rubbish to out side the MoD land complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and paving (un reinforced) not exceeding 15 cm, thickness, below or above ground level and removing rubbish to outside the MoD land complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (Unreinforced) of any description and in any position not othewise specifically provided for and removing rubbish to outside the MoD land complete all as specified and as directed by Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality, or description) from metal frame glazed with putty or fixed with beads/ clips complete including removing broken glasses to outisde the MoD land all as specified and as directed by Engr-in-Charge.
Taking down cement plaster on brick walls or stone walls any description etc including raking out joints, hacking for key, scrubbing down with water etc complete including removing rubbish to outisde the MoD land all as specified and as directed by Engr-in-Charge.
Taking up or down steel water tubing and connections including cleaning for refixing or removal to store for bore of pipe 15mm dia all as specified and as directed by Engr-in-Charge.
Taking up or down steel water tubing and connections including cleaning for refixing or removal to store for bore of pipe 20mm dia all as specified and as directed by Engr-in-Charge.
Taking down eaves gutters and rainwater pipes 100 mm dia (any size or pattern) including all fitting, head, shoes, bend, swan-nacks etc., including cleaning or refixing or removal to store complete all as specified and as directed by Engr-in-Charge.
Dismantling of brick tiles, terracing tiles, single layer from roof laid, bedded and pointed in any mortar complete including removing unserviceable tiles and rubbish to out side the MoD land all as specified and as directed by Engr-in-Charge.
Repair to old steel window shutter of area not exceeding 1 sqm each including replacement of hinges, handle and necessary welding to shutter and chowkhat for making window in serviceable condition, including two coats of synthatic enamal paint complete all as specified and as directed by Engr-in-Charge.
Repair to old steel window shutter of area exceeding 1.00 sqm but not exceeding 2 sqm each including replacement of hinges, handle and necessary welding to shutter and chowkhat for making window in serviceable condition, including two coats of synthatic enamal paint complete all as specified and as directed by Engr-in-Charge.
M&L 35 mm thick single piece factory made wire gauge door shutter and including of wire cloth ( steel & aluminium XPM) manufacturing by PVC sheets printed 5 mm thick on both side on frame made out of M.S. tube 19 SWG, of size 19mmx19 mm complete in all respect with lock rail & beautified by PVC beading all around fixed with PVC solvent cement including all requisite necessary accessories complete all as specified as per Drg No. CEPZ/TD-378/11, Sheet 1/1 dated 27/12/2011 and as directed by Engineer-in-Charge.
Supply and fixing of Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65mm x 125 mm(double rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position including with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified & as directed by Engineer-in-charge. Note: (i) For WPC solid door/window frames minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed.
Supply and fixing of Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65mm x 100 mm ( Single rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position including with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed.
Supply and fixing of Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 50mm x 100 mm ( Single rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position including with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed.
Supply and fixing of Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45mm x 70 mm ( Single rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position including with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel but hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified & as directed by Engineer-In-Charge. (Note : Stainless steel butt hinges shall be measured and paid separately under respective item of BOQ)
S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws all as specified & as directed by Engineer-In-Charge. (Note : Stainless steel butt hinges shall be measured and paid separately under respective item of BOQ)
Material and labour for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including two coat of synthetic enamel paint over a coat of red oxide primer etc all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair for stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples and beads to frame complete all as specified & directed by Engr-in-Charge.
Material and labour for 3 mm thick sheet glass ordinary quality fixed in glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
Material and labour for 3 mm thick Frosted / Pinned type glass, pin head type & glazing with oil putty in squares of size not exceeding 0.5 sq.m in each pane complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of 100 mm long Stainless steel Butt hinges, medium weight, cold rolled, and fixed complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of size 300mm long Aluminium alloy, powder coated, sliding door bolt with haspe and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of size 200mm long aluminium powder coated barrel tower bolts of extruded section and fixed complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of size 150 mm long powder coated alloy handles, fabricated type anodised extruded section (ISI marked) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of mild steel stove enameled door spring not less than 200 mm long ordinary rat tail rod pattern spring fixed to pressed steel frame / MS frame / wooden chowkhats and necessary welding work etc (if required), including roller and rolling plate complete all as specified and as directed by Engr-in-Charge
Supply and fixing of 100 mm long hasp and staple, mild steel wire / plate type stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair curtain rod of 20 mm dia bore size (wall thickness not less 01mm) made out of stainless steel with fixing brackets fancy type, stops, end bulbs etc. The curtain rod shall be projecting 150mm outer side from the clear opening of doors/windows including necessary fittings complete all as specified and as directed by Engr-in-Charge.
Material and Labour for Brickwork with Fly Ash Bricks (old size bricks) having crushing strength not less than 75kg/Sqm straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed by Engr-in-Charge.
Material and Labour for Brickwork with Fly Ash Bricks (old size bricks) having crushing strength not less than 75kg/Sqm straight or curved on plan exceeding 6m mean radius built in CM (1:4) complete all as specified and as directed by Engr-in-Charge.
Material and labour for Rendering 10mm thick in cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
Material and labour for Rendering 05 mm thick in cement plaster on faces of brick work or concrete surfaces in cement mortar (1:3) as in ceiling finished even and fair without using extra cement complete all as specified and as directed by Engr-in-Charge.
Material and labour for Rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) in two layers i.e. first layer 10mm thick and second layer of 5mm thick shall be mixed with liquid water proofing admixture as per manufacturer's instructions finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge Note : Water proofing compound shall be measured and paid for separately under respctive item.
Material and labour for rendering 10mm thick in cement mortar 1:3 on edging / ceiling of Chajjas, roof projections etc, including taking out peeled off plaster / concrete and making the line in true shape and finishing the surface without using extra cement complete all as specified and as directed by Engr-in-Charge.
Material and labour for 75mm thick Plain Cement concrete (1:3:6), type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection and paving and laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen of grade 85/25 and sand in ratio 1:2 by weight including use & waste of necessary form work complete all as specified and as directed by Engr-in-Charge.
Material and labour for joint free non skid ceramic coloured tiles 7 to 8 mm thick and area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in skirting/dado/riser of steps etc set and jointed in neat cement slurry and pointed in coloured cement to match the finish laid over 10mm thickness rendering as backing in C.M (1:4) including dismantling existing floor tiles of any type & pattern including cement mortar bedding & removing debries/tiles out of the premises etc all as specified and as directed by Engr-in-Charge
Material and labour for joint free non skid ceramic coloured tiles 7 to 8 mm thick and area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the finish including dismantling existing floor laid over 15mm thickness scread bed in CM (1:4) tiles of any type & pattern including cement mortar bedding & removing debries/tiles out of the premises etc complete all as specified and as directed by Engr-in-Charge.
Material and labour for double charged vitrified tiles (light shade) 8-9mm thick (square or ractangular) polished and area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match the finish, over 15mm thick screed bed or bedding layers of mortar in Cement motar 1:4 for laying floor finishes complete including dismantling existing floor tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and as directed by Engr-in-Charge.
Material and labour for double charged vitrified tiles (light shade) 8-9mm thick (square or ractangular) polished and area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm as in skirting/dado/riser of steps etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match the finish, over 10mm thick screed bed or bedding layers of mortar in Cement motar 1:4 for laying floor finishes complete including dismantling existing floor tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and as directed by Engr-in-Charge.
Material and labour for glazed ceramic coloured tiles on vertical surface of size 450mmx350mmx7mm thick or 450mmx300mmx7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering 10mm thick in CM (1:4) finished rough including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) & removing serviceable tiles from site and rubbish off the premises complete all as specified and as directed by Engr-in-Charge
Material and labour for single piece 18mm to 20mm thick green Marble work (table rubbed and polished) as in cooking plateform, window cill, steps etc and set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Bhaislana Zebra over and including 15mm thick screed bed in cement mortar (1 : 4) and making hole for gas pipe including dismantling of existing tiles/stones and removing debris/tiles out off the premises etc complete all as specified and as directed by Engr-in-Charge.
Material and labour for single piece 20mm thick Granite (of any type) work (table rubbed and primer polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed or bedding layers of mortar in Cement motar 1:4 including making hole for gas pipe & dismantling of existing tiles/stones including removing debris/tiles out off the premises etc complete all as specified and as directed by Engr-in-Charge.
Material and labour for Round chamfering, to the edges of marble slabs complete all as specified and as directed by Engr-in-Charge.
Material and labour for preparation of Old wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint on wooden surface complete all as specified and as directed by Engr-in-Charge.
Material and labour for two coats of synthetic enamel paint on old steel surfaces of any description, n.exc 10 cm in width or girth, including preparation of surfaces, all as specified and as directed by Engr-in-Charge.
Preparation of new plastered surface of external wall and chajjas and making the surface smooth with sand paper and priming the surface with alkali resistance primer paint on external surface and applying two coat of exterior emnlsion (weather coat) paint over primed surface all as specified and as directed by Engr-in-Charge.
Material and labour for Preparation of new plastered surface of wall, applying 02 mm thick wall care putty and making the surface smooth and applying two coats of distemper oil emulsion on new surfaces of walls over a coat of primer complete all as specified and as directed by Engr-in-Charge.
Material and labour for three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and as directed by Engr-in-Charge.
Material and labour for three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and as directed by Engr-in-Charge.
Material and labour for Preparation of old surface by complete removal of existing treatment and making the surface smooth including applying 02 mm thick wall care putty and two coats of Oil bound distemper on old surface of wall surface over a coat of primer complete all as specified and as directed by Engr-in-Charge.
Preparation of old Wall surface after complete removal of existing treatment and making the surface smooth and applying two coat of exterior emulsion paint (WEATHER COAT) over a coat of alkali resistance priming paint on old surface of walls complete all as specified and as directed by Engr-in-Charge.
Material and labour for two coats of white wash on old surface of a wall including preparation of old plastered wall surface complete all as specified and as directed by Engr-in-Charge.
Material and labour for two coats of white wash on old surface of ceiling including preparation of old ceiling plastered surface complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing for 15mm bore Galvanised steel water tubing, medium grade with all fittings (ISI Marked), fixed complete concealed to walls, ceiling or laid in floors complete all as specified and as directed by Engr-in-Charge. (Note : Cutting chases for concealed piping shall be measured and paid for separately under respective items).
Refixing of 15mm bore old steel water tubing medium grade galvanized (ISI marked) with all fittings short pieces such as and fixed complete concealed in walls, floor etc complete all as specified and as directed by Engr-in-Charge.
Material and labour for Cutting chases in Brick walls, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing for 20mm bore GI steel water tubing surface/ concealed, medium grade galvanized with all fittings (ISI Marked) (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor all as specified and as directed by Engr-in-Charge. (NOTE:- Cutting chases for concealed piping shall be measured and paid separately under respective items).
Refixing of 20mm bore old steel water tubing medium grade galvanized (ISI marked) with all fittings such as short pieces and fixed complete to walls, floor etc all as specified and as directed by Engr-in-Charge.
Supply and fixing for Stop valve/ Angle valve cast copper alloy (ISI Marked) chromium plated Fancy type including suitable flange screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of size 15mm bore dia as fixed in reapirs all as specified and as directed by Engr-in-Charge.
Supply and fixing for Stop valve concealed cast copper alloy capstan head (ISI Marked) fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with screwed both ends for iron pipe of size 15mm bore dia as fixed in repair complete all as specifed and as directed by Engr-in-Charge.
Supply and fixing Bib tap for 15 mm bore dia pipe, cast copper alloy cromium plated fancy type including suitable flange screwed down crutch or butterfly handle with brass furrele as fixed in repairs complete all as specifed and as directed by Engr-in-Charge.
Supply and fixing Bib tap for 15 mm bore dia pipe, cast copper alloy cromium plated fancy type long body screwed down crutch or butterfly handle with brass furrele complete all as specifed and as directed by Engr-in-Charge.
Supply and fixing for Vitreous china wash hand basin, white flat back of size 550mm x 400 mm including waste pipe, brackets and cutting for and pinning in ends of brackets or errecting stand fixed including 32 mm dia bore PVC waste pipe of minimum size 600 mm long and waste coupling (PTMT) of 32mm dia bore (min weight 32mm-45gms) size full thread as in Repair complete all as specifed and as directed by Engr-in-Charge.
Supply and fixing for of Brass CP suitable for centre hole basis mixer for mixing hot & cold water screwed down for 15mm bore dia of pipe & 450mm long iron pipe and fixed cast copper alloy, with capstan heads, chromium plated, crewed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specifed and as directed by Engr-in-Charge.
Supply and fixing for three in one wall mixer with over head and telescopic brass chromium plated shower rose of 125mm size brass CP mixer for mixing hot & cold water screwed down for iron pipe of size 15mm bore pipe with or without swivel joints , any size, inclding fixing to steel pipe or union complete all as specifed and as directed by Engr-in-Charge.
Supply and fixing for health faucet hand shower 8mm dia of size 1metre with long flexible hook and wall mounting stand complete all as specifed and as directed by Engr-in-Charge.
Supply and fixing as in repair Brass chromium Plated Tubular Towel rail (minimum weight shall not be less than 600 gms),20mm dia 'D' type plated of size 600 mm long between flanges fixed wih chromium plated screw & PVC cleats complete all as specifed and as directed by Engr-in-Charge.
Supply and fixing as in repair Brass Chromium Plated Shower rose with or without swivel joints, 125mm long including fixing to steel pipe or union complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Vitreous China squatting pan of orissa pattern, of size 580mmx440mm white with Intergral foot rest & CI ‘P’ or ‘S’ trap, front or back inlet any pattern (including fixing of flush pipe) and making connection to trap and to flushing pipe antisyphonic pipe including demolition of existing pan and as fixed in repair complete all as specified and as directed by Engr-in-Charge. (Note :- P.C.C in bedding shall be measured and paid sepratelly under respective item of BOQ).
Supply and fixing for Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Pedestal pan and trap and connection to drain (or outgoing pipe) and to the flushing pipe, antisyphonage pipe, etc. and including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engr-in-Charge.
Material and labour for Plain Cement Concrete (1:5:10) type E2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete (sunken floors etc.) complete all as specified and as directed by Engr-in-Charge.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 using liquid water proofing compound to sunken portion with proper slope towards outside and finishing cement concrete or brick work surface even and smooth using extra cement including application of 90 micron polythene film and applying bitumen coating @ 3.00 Kg/Sqm all as specified and as directed by Engr-in-Charge. Note : Water proofing compound shall be measured and paid for separately under respctive item.
Supply and fixing as in repair Low level PVC flushing cistern of 10 litres capacity including PVC connection and integrated Ball Valve, inlet and outlet connections, brackets, PVC flush pipe with bend of size 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for PVC connections for pipe of 15mm bore dia size with PTMT nuts of length 450mm as in repair complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing for Rotational moulded polyethlene water storage tanks of capacity 500 litres three layers (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float and including dismantling of existing RCC/ PVC tank of any capacity and removing rubbish to outside the MoD land in case of RCC tank complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing for Rotational moulded polyethlene water storage tanks of capacity 1000 litres three layers (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float and including dismantling of existing RCC/ PVC tank of any capacity and removing rubbish to outside the MoD land in case of RCC tank complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed cast copper alloy, (ISI marked) with crutch or butter fly handles screwed down screwed for iron pipe of size 20mm dia bore complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for PVC (SWR) pipes of size 110mm bore, single socketed, in any length with rubber ring joints fixed to walls with and including clamps complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair PVC (SWR) pipes of size 75mm bore, single socketed, in any length with rubber ring joints fixed to walls with and including mild steel clamps all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair PVC (SWR) pipes of size 75mm bore, single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 110mm PVC (SWR) bends any radius complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 75mm PVC (SWR) bends any radius complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair PVC (SWR) pipes of size 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair PVC (SWR) pipes of size 110mm bore, single socketed, in any length with rubber ring joints, fixed to walls or in floors complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 110mm PVC (SWR) reducers complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 75mm dia PVC (SWR) vent cowl complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal, provided with oval access door (ISI Marked) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 75mm dia PVC (SWR) branch piece, double (double Y) equal or unequal, provided with oval access door (ISI Marked) complete all as specified and as directed by Engr-in-Charge.
Material and labour as in repair PVC(SWR) floor trap 75 mm dia with grating including jointing with solvent cement complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair 100 mm dia bore sand cast iron soil waste and vent pipes (spun pipes) (ISI marked) in any length with or without ears as laid in floor with cement joints complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair 100mm dia bore sand cast iron soil waste and vent pipes (spun pipes) (ISI marked) in any length with or without ears fixed to walls with clamps and cement joints complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair in 75 mm dia bore sand cast iron soil waste and vent pipes (spun pipes) (ISI marked) in any length with or without ears laid in floor with cement joints complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair 75mm bore sand cast iron soil waste and vent pipes (spun pipes) (ISI marked) in any length with or without ears fixed to walls with clamps and cement joints complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair 50mm dia bore sand cast iron soil waste and vent pipes (spun pipes) (ISI marked) in any length with or without ears fixed to walls with clamps and cement joints complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair 100 mm dia bore CI bends (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair Cast Iron Branch peices, single (ISI Marked) (equal or unequal) ordinary or inverted (spigot or socket type), or with parrallel branches fitted with oval access door of 100 mm bore dia complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair 75 mm dia bore Cast Iron bends (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair Cast Iron Branch peices, Double (ISI Marked) (equal or unequal) ordinary or inverted (spigot or socket type), or with parrallel branches fitted with oval access doors of 75 mm bore dia complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair CI floor trap 75 mm dia bore of outlet with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) with CP grating with or without hole for waste pipe complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair cast iron cowl for 50 mm dia bore & fixing to pipe complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for stainless steel sink with drainage board made of stainless steel sheet of 1mm thick for kitchen with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe with overall size of 915mmx460mm and bowl of size 410mm x 330mm x 160mm including 32 mm dia bore PVC waste outlet pipe of single length up to grating complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for stainless steel kitchen plate rack of size 750mm x 900 mm made of stainless sheet of 1mm thick of approved make fixed with mild steel screw and PVC cleats on wall surface complete all as specified and as directed by Engr-in-Charge.
Material and labour for mild steel TMT bars (Fe-500D) 10mm dia & over cut to length bend to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge.
Material and labour for mild steel TMT bars (Fe-500D) 6 to 8mm dia & over cut to length bend to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge.
Material and labour for Plain Cement Concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregates) as in levelling course/padding using water proofing compound laid over existing roof, surface finished rough to receive cement mortar including necessary use and waste of formwork including demolition of exisitng cement concrete padding of any description and any thickness complete all as specified and as directed by Engr-in-Charge. Note: (WPC shall be measured and paid separately under respective items of BOQ )
Material and labour for plain cement concrete (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) as in seismic, plinth and similar bands, coping, kerbs, cills, steps, parapets, apex stones, bed plates, kerbs, railings up to 60 cm in height, water troughs and the like rounded or chamfered on edges and situation like broken RCC Chajjas, Roof projection including necessary use and waste of form work all as specified and as directed by Engr-in-Charge.
Material and labour for Rendering 20mm thick in cement mortar 1:4 on concrete surface finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 litre in 50 Kg of cement complete all as specified and as directed by Engr-in-Charge. (Note:- Water proofing compound shall be measured and paid separately under respective items of BOQ)
Material and labour for APP modified roof treatment over existing accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as specified and as directed by Engr-in-Charge:- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 litre/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under: (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gms/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.
Material and labour for APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as specified and as directed by Engr-in-Charge:- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 litre/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gms/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
Material and labour for Plain Cement Concrete tiles of size 300mm x 300mm x 22mm-25mm thick shall be laid over 10mm thick in screed bed or bedding layer of cement mortar 1:4 and jointed and pointed in cement mortar 1:3 etc complete all as specifed and as directed by Engr-in-Charge.
Material and labour for 40mm thick serviceable brick tile (Except brick tile) as laid on cement mortar & joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement over and including 15mm thick screed bed or bedding layer of cement mortar in CM 1:6 etc complete all as specifed and as directed by Engr-in-Charge. (Note:-Servicable brick tiles shall be used as retrived from serial item no-12 here-in-before. Furhter, quoted rates for this item shall include shifting of brick tiles including its lead from one block to another block. No claim whatsoever shall be admissible on this account at the later stage.)
Supply only Polymer liquid water proofing compound of approved make complete all as specified and as directed by Engr-in-Charge.
Material and labour for cleaning, breaking of loose concrete and cleaning of reinforcement and providing rust coating of PH RB-167 / rust free / SHEILDOXY over old reinforcement and welded with new reinforcement, if required and applying bonding adhesive chemical of STP / Fosroc over old concrete including filling the same with plain cement concrete 1:1.5:3, type A0 (using 12.5mm graded crushed stone aggregate) at places as per site requirement complete all as specifed and as directed by Engr-in-Charge (Note:- The cost of scaffolding including use and waste of form work shall deemed to be included in the quoted rate for this item). (Note :- Reinfoircement shall be measured and paid seprately under respective item of BOQ)
Material and labour for cleaning, breaking of loose concrete and cleaning of reinforcement and providing rust coating of PH RB-167 / rust free / SHEILDOXY over old reinforcement and welded with new reinforcement, if required and applying bonding adhesive chemical of STP / Fosroc over old concrete incuding filling the same with plain cement concrete 1:1.5:3, type A1 (using 20mm graded crushed stone aggregate) at places as per site requirement complete all as specifed and as directed by Engr-in-Charge (Note:- The cost of scaffolding including use and waste of form work shall deemed to be included in the quoted rate for this item). (Note :- Reinfoircement shall be measured and paid seprately under respective item of BOQ)
Material and labour for Providing and injecting chemical emulsion for post constructional anti-termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litre per linear meter including drilling and plugging of holes with Cement Mortar 1:2 to match the exisiting finish etc as in apron/plinth protection complete all as specified in IS-Code 6313 Part (3) : 2001 and as directed by Engr-in-Charge.
Material and Labour for Providing and injecting chemical emulsion for post constructional anti-termite treatment of soil under existing floors using chemical emulsion @ one litre per hole at a distance 300 mm apart along the junction of floor and wall, along joints in floors including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floor complete all as specified in IS code-6313 Part (3) : 2001 and as directed by Engr-in-Charge.
Material and Labour for writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high and the colour of paint and dimension of letter to be used complete all as specified and directed by Engr-in-Charge.
Material and Labour for writing Stops, commas, short lines, dashes, hyphens, brackets, etc and the colour of paint and dimension of characters to be used as approved by Engr-in-Charge.
Material and labour for Providing precast cement concerete (1:2:4) type B-1 using 20mm graded crushed tone aggregate as in cover slabs and similar articles inclduing necessary moduls/formwork set in cement mortar (1:6) complete all as specified & as directed by Engineer-in-Charge.
Supply and fixing factory made 18mm thick WPC (wood polymer composite) sheet one side prelam sheet and other side wood nature colour for cupboard shutter of density 600 Kg / Cum bent to 90° including 100% termite/water proof, fire rertradent, Eco friendly and finish at all edges at level for making edges lining using binding tap etc as in Kitchen cupboard Cabinet etc complete all as specified as per Manufacture specififaction and as per direction of Engr-in-Charge.
Supply and fixing factory made 18mm thick WPC (wood polymer composite) sheet both side plain borad without printed for cupboard shutter of density 600 Kg / Cum bent to 90° including 100% termite/water proof, fire rertradent, Eco friendly and finish at all edges at level for making edges lining using binding tap etc as in Kitchen cupboard Cabinet etc complete all as specified as per Manufacture specififaction and as per direction of Engr-in-Charge.
Supply and fixng for factory made 5mm thick WPC board one side prelam sheet for kitchen cabinet/cupboard of density 600 Kg / Cum bent to 90° including 100% termite/water proof, fire rertradent, Eco friendly etc complete all as specified as per Manufacture specififaction and as per direction of Engr-in-Charge.
Supply and fixng for 150mm size stainless steel bright finish handle, fixed with Nut and bolt complete all as specified & as directed by Engineer-in-Charge.
Supply and fixng for telescopic type side channel of drawer of standard size including roller for moving drawer made out of mild steel bright finish or electro gallvanised (soft close ball bearing runners) with width of flap 30mm & 60mm long complete all as specified & directed by Engineer-in-Charge.
Supply and fixng for stainless steel of Grade 304 plate basket of size 17" x 20" x 6", complete (ISI marked) all as specified and dirceted by Engineer-in-Charge.
Supply and fixng for stainless steel of Grade 304 plain pertition of size 17" x 20" x 6", complete (ISI marked) all as specified and dirceted by Engineer-in-Charge.
Supply and fixng for stainless steel of Grade 304 plain cutlery of size 17" x 20" x 4" (plate type), complete (ISI marked) all as specified and dirceted by Engineer-in-Charge.
Supply and fixng for stainless steel of Grade 304 plain cup & soucer of size 17" x 20" x 4", complete (ISI marked) all as specified and dirceted by Engineer-in-Charge.
Supply and fixng for stainless steel of Grade 304 plain basket of size 17" x 20" x 6", complete (ISI marked) all as specified and dirceted by Engineer-in-Charge.
Supply and fixng for stainless steel of Grade 304 auto zero crank hinges, fancy type with concealed pattern fitted to shutters complete (ISI marked) all as specified by Engineer-in-Charge.
Supply and fixng for Magnetic catcher for shutter of approved pattern fitted with suitable screws (ISI marked) complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and not exc 10 Sqm on plan in any type of soil or all kind of Soil and getting out, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil or all kind of Soil complete all as specified and as directed by Engr-in-Charge.
Removal of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point and disposal outside the premises complete all as specified and as directed by Engr-in-Charge.
Material and labour for 75 mm thickness Plain cement concrete (1:4:8) (type D-2) (Using 40mm graded crushed stone aggregates) as in sub base for Flooring complete all as specified and as directed by Engr-in-Charge.
Material and labour for 60mm thick factory made machine pressed Precast Cement concrete (Rubberised coloured, Laminated) interlocking Paver block (using Vibro compaction method) (Topping thickness not less than 5mm) with Grey cement & pigment (non fadable glossy Pigment) of approved shade of any shape and size conforming to IS-15658-2006 of M-35 Grade laid over 25mm thick sand cushion under floor including watering and Consolidering complete all as specified and as directed by Engineer-in-Charge.
Demolition / breaking / cutting of existing cement concrete (reinforced) as in kitchen chimney / chulla hood and the similar including making good the disturbed surface of wall with cement mortar (1:3) finished even & smooth without using extra cement complete all as specified and directed.
Supply and Fixing as in repair glass corner shelf of shape quarter round of size (225mm dia) with CP Brass Bracket of approved make and fixed to wall surface with requisite fitting arrangements complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in reapir sheet glass assembly of size 18" (inches) x 5.5 (inches) consisting of chromium plated bracket guard and railing of approved make and fixed to wall surface with requisite fitting arrangements complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, with plastering in CM (1:6) inclduing application of colour wash to match the exisitng surface finishes etc complete all as specified and as directed by Engr-in-Charge.
Material and labour for Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable of size 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor cable of 1100 volts grade as earth wire drawn through and including concealed PVC conduit (ISI Marked) of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box including sunken modular metal flush gang box (16 guage) of approved makes and suitable support frame and cover plate (inner & outer) of required modules for mounting modular switch/socket etc connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible) (With proper colour code will be used for wiring as per the electrical rule), For one light point controlled by one way switch, 240 volts SP complete all as specified and as directed by Engineer-in-Charge (Note : (i) Switch/bell push/fan regulator etc shall be measured and paid separately under respective items. (ii) Cutting chases for point wiring concealed PVC rigid conduit shall deemed to be included in the quoted rate of this item.)
Material and labour for Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable of size 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor as earth wire drawn through and including concealed PVC conduit (ISI Marked) of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box including sunken modular metal flush gang box (16 guage) and suitable support frame and cover plate (inner & outer) of required modules for mounting modular switch/socket etc connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible) (With proper colour code will be used for wiring as per the electrical rule), For One light point controlled by two 2-way switch complete all as specified and as directed by Engr-in-Charge (Note : (i) Switch/bell push/fan regulator etc shall be measured and paid separately under respective items. (ii) Cutting chases for point wiring concealed PVC rigid conduit shall deemed to be included in the quoted rate of this item.)
Material and labour for Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable of size 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor as earth wire drawn through and including concealed PVC conduit (ISI Marked) of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box including sunken modular metal flush gang box (16 guage) and suitable support frame and cover plate (inner & outer) of required modules for mounting modular switch/socket etc connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible) (With proper colour code will be used for wiring as per the electrical rule), for socket point on same board controlled by one way switch complete all as specified and as directed by Engr-in-Charge (Note : (i) Switch/bell push/fan regulator etc shall be measured and paid separately under respective items. (ii) Cutting chases for point wiring concealed PVC rigid conduit shall deemed to be included in the quoted rate of this item.)
Material and labour for Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable of size 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor as earth wire drawn through and including concealed PVC conduit (ISI Marked) of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box including sunken modular metal flush gang box (16 guage) and suitable support frame and cover plate (inner & outer) of required modules for mounting modular switch / socket etc connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible) (With proper colour code will be used for wiring as per the electrical rule), for one socket outlet point on Independent board controlled by one switch, Single pole, One way, 6 Amps, 240 Volts complete all as specified and as directed by Engr-in-Charge (Note : (i) Switch/bell push/fan regulator etc shall be measured and paid separately under respective items. (ii) Cutting chases for point wiring concealed PVC rigid conduit shall deemed to be included in the quoted rate of this item.)
Material and labour for point wiring using FRLS PVC insulated unsheathed/multi stranded copper conductor cable 2.5 sqmm including 2.5 sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20mm dia and 1.8 mm thick including all fittings viz tees, bends, juction box including sunken modular metal flush gang box (16 guage) and suitable support frame and cover plate (inner & outer) of required modules for mounting modular switch / socket etc for one socket multi purpose independent point controlled by one way switch connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles of pin/u type etc (conduit shall be fixed on surface of ceilng with necessary saddles where concealing of conduit is not feasible), complete all as specified and as directed by Engr-in-Charge . (Note : (i) Switch/Socket etc shall be measured and paid separately under respective items. (ii)Cutting chases for point wiring concealed PVC rigid conduit shall deemed to be included in the quoted rate of this item.)
Material and labour for Submain wiring with 2 run of single core, 10 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 volts FRLS (using colour code as per IS) with and including 1 x 10 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through and Including cutting groove for conclead wiring and concealed PVC rigid conduit of 25mm bore dia size, heavy grade (ISI marked) having thickness not less than 1.8mm with and including all accessories, complete including taking down old submain wiring (any type any size) complete all as specified and as directed by Engr-in-Charge. Note : (i) Two runs of single core cable with one run of earth cable and conduit shall be measured as one RM. (ii) Cutting chases for sub main wiring concealed PVC rigid conduit and making good the disturbed surfaces of wall to match the existing surface shall deemed to be included in the quoted rate of this item.
Material and labour for Submain wiring with 2 run of single core, 4 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 volts FRLS (using colour code as per IS) with and including 1 x 4 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through and Including cutting groove for concealed wiring and concealed PVC rigid conduit of 20mm bore dia size, heavy grade (ISI Marked) having thickness not less than 1.8mm with and including all accessories, complete all as specified and as directed by Engr-in-Charge. Note :(i) Two runs of single core cable with one run of earth cable and conduit shall be measured as one RM. (ii) Cutting chases for sub main wiring concealed PVC rigid conduit and making good the disturbed surface shall deemed to be included in the quoted rate of this item.
Supply and fixing for modular Switch single pole, one way, not less than 6 Amp, one module, front operated AC 240 volts (ISI marked) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for modular Switch flush button single pole, one way, not less than 16 Amp AC 01 module240 volts (ISI marked) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for modular Socket outlet 2 /3 pin multipurpose type, 2 module, not less than 6 Amp/16 Amp AC, 240 Volts (ISI Marked ) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for modular Socket outlet 2 /3 pin multipurpose type, 2 module, not less than 6 Amp AC, 240 Volts (ISI Marked ) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for modular switch 2 way 10A 1 module, AC 240 volts complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for modular Switch bell push flush type not less than 6 Amp 1 module AC, 230 volts complete all as specified and as directed by Engr-in-Charge
Supply and fixing for Ding dong door bell electric suitable for AC 230 Volt, single pole complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Ceiling rose polycarbonate isolated body surface bakelite not less than 65mmx50mm dia three terminals AC, 240 volts complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for modulor Ceiling fan regulator electronic type or BLDC type 5 stage (step type) speed variation not less than 100 W, 2 module socket type in size, suitable for 1200 mm sweep Ceiling fan hum free including necessary connections complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including 15 Watt LED lamp of approved make and Cat part No and PVC round/square block etc complete all as specified and as directed by Engr-in-Charge.
M&L for SPN MCB DB 12 way, sheet metal enclosures double door 230 Volts AC, 50 Hz AC with copper bus bar of rating not less than 100 Amps including insulated neutral and earth link and polyurethane gasket including taking down old unserviceable DB complete as specified and as directed by Engr-in-Charge.
Supply and fixing for MCB SP 240 Volt, 50 Hz, 10 KA, 'B' curve of rating 6 Amp to 32 Amp complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing for MCB SP 240 Volt, 50 Hz, 10 KA, 'B' curve of rating 40 Amp to 63 Amp complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing for MCB SPN 240 Volt, 50 Hz, 10 KA, 'B' curve of rating 40 Amp to 63 Amp complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing of LED light fitting 10 Watt (IP-66 Protection) bulk head, energy efficient, wall mounted pressure die cast aluminium housing and enclosed with polycarbonate cover with all accessories and clear prismatic diffuser CCT 5700K+/-300K complete with all accessories and including connecting up with flexible PVC insulated over all sheathed copper conductor cable of suitable size of 230 V, 50 Hz as in repair complete all as specified and as directed by Engr-in-Charge.
Supply and fixing LED building / street light fitting of capacity 1x30 watts, 230 volt, energy saving and environmental friendly long life versatile pressure die cast aluminium (IP- 65 Protection), IK-07 rating road way luminary high power LED street light with electronic driver including heat resistance toughened glass with lens as light source complete mounted on wall/pole with and including GI bracket made out of suitable dia as per light fitting bore and 0.8 mtr long light grade GI Pipe bent to shape mounted on wall with the help of 02 Nos suitable size of FI holding clamp with nuts, bolts and washers and making electrical connection with three core cord flexible PVC insulated over all sheathed copper conductor cable of suitable size from ceiling rose to light fittings, with all accessories internally pre wired as in repair complete all as specified and as directed by Engr-in-Charge. NOTE:- 1. LM-79 and LM-80 test report from NABL lab shall be povided. 2. CRI (Coulour Rendring Index) of fixture shall be > 80. 3. CCT (Colour Corelated temprature) of fixture shall be 5700+/-300K. 4. System Lumen Efficacy shall be > 120Lm/W. 5. The defect liability period of LED light shall be 02 years from the certified date of completion & the Contractor shall replace/repair the defective fitting within 07 Days after handing over to Contractor. 6. CA No shall be written on each fitting before installation. 7. The name of manufacturer to be embossed on the fitting. 8. The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.
Supply and Fixing for mirror light fitting 10 watt 2 feet LED type with all accessories including inbuilt lamp connecting electrically to ceiling rose using cord flexible PVC insulated over all sheathed copper conductor of suitable size as in repair complete all as specified and as directed by Engr-in-Charge. Notes :- 1. CCT (Colour Corelated temprature) of fixture shall be 5700+/-300K. 2. System Lumen Efficacy shall be > 100Lm/W 3. The defect liability period of LED light shall be 02 years from the certified date of completion & the Contractor shall replace/repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 4. CA No shall be written on each fitting before installation.
Supply and Fixing for round shaped surface mounted 18 watt LED luminaire with dome shaped high quality opal diffuser, inbuilt driver with efficacy 100Lm/W, CRI>80 with 5700+/-300 K CCT with high efficiency long life, complete with all accessories innternally prewired and including conecting up with cord flexible PVC insulated over all sheathed copper conductor of suitable size to connector of LED fitting as in repair complete all as specified and as directed by Engr-in-Charge NOTE:- 1. The defect liability period of LED light shall be 02 years from the certified date of completion & the Contractor shall replace/repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 2. CA No shall be written on each fitting before installation. 3. The name of manufacturer to be embossed on the fitting.
Supply and Fixing for decorative wall mounting LED bed side light of capacity 3 watt, 3000K fitting having flexible neck and mounting arrangements with all accessories including inbuilt lamp connecting electrically to ceiling rose using cord flexible PVC insulated over all sheathed copper conductor of suitable size as in repair complete all as specified and as directed by Engr-in-Charge. Notes :- 1. CCT (Colour Corelated temprature) of fixture shall be 3000K. 2. System Lumen Efficacy shall be > 100Lm/W 3. The defect liability period of LED light shall be 02 years from the certified date of completion & the Contractor shall replace/repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 4. CA No shall be written on each fitting before installation.
Supply and Fixing for surface mounted decorative, fancy light fitting with decorative diffuser alongwith mounted clips and lamp holder with wall mounting arrangements inclduing 09 Watt LED lamp with all accessories connecting electrically to ceiling rose using cord flexible PVC insulated over all sheathed copper conductor of suitable size as in repair complete all as specified and as directed by Engr-in-Charge. Notes :- 1. CCT (Colour Corelated temprature) of fixture shall be 5700+/-300K. 2. System Lumen Efficacy shall be > 100Lm/W 3. The defect liability period of LED light shall be 02 years from the certified date of completion & the Contractor shall replace/repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 4. CA No shall be written on each fitting before installation.
Supply and fixing of 20W surface/wall mounted box type batten LED luminaire comprises with inbuilt 20 watt LED strip, extruded aluminium housing with PC diffuser and integrated electronic driver with high efficiency long life, CRI=80 (Minimum), PF>0.95, luminous efficacy>100 lumens/Watt operating voltage 140V-240V, CCT (K) shall be 5700+/-300, THD<10% complete with all accessories innternally prewired and including conecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and as directed by Engr-in-Charge NOTE:- 1. The defect liability period of LED light shall be 02 years from the certified date of completion & the Contractor shall replace/repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 2. CA No shall be written on each fitting before installation.
Material and labour for Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to Galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore dia including 40mm thick cover of RCC (1:2:4) Type B-1 (using 20mm graded crushed stone Aggregate) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made of shape, GI medium grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil or all kind of soil including returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I (specification) and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and as directed by Engr-in-Charge
Material and labour for Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to Galvanized earth strip of size 32mm x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore dia including 40mm thick cover of RCC (1:2:4) Type B-1 (using 20mm graded crushed stone Aggregate) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made of shape, GI medium grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil or all kind of soil including returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I (specification) and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and as directed by Engr-in-Charge.
M&L for distribution board iron clad vertical TPN DB double door made out of CRCA power coated sheets with IP-43 protection and mechanical strength as IK-09 suitable for MCCB as incomer and MCB as outgoing 415V 3 Phase 50Hz 4 way complete with appropriate size bus bar, insulated neutral and earth link, polyurethane gasket on door link complete with one MCCB 4 pole 415 V 100 Amps rating, 16 KA with fixed thermal and fixed magnetic release of the same make as of distribution board complete all as specified and as directed by Engr-in-Charge. Note: (MCBs will be measured and paid separately under respective items)
Supply and fixing wall mounted three blade, copper wounded fan AC single phase 230/240 volts of size 400mm sweep 1400±100 RPM with an air delivery rate of up to 65±5 cubic metres per minute with three speed control and pull cord mechanism including wall mounting arrangements and connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fixing of heavy duty of 230 mm sweep, double ball bearing copper wounded metallic exhaust fan AC single phase 230/240 Volts having 1400+/-50RPM and power consumption not more than 50 watt with minimum air delivery 700 CMH including box type square shaped metallic louvers made out of powder coated CRCA sheet of thickness not less than 01 mm alongwith Aluminium flaps and fixed with grouting nut bolts and making the suitable hole of suitable size by breaking the existing wall and making good the disturbed surface by plastering and matching with existing specifications with suitable finishes as per site requirement complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for modular TV socket outlet, 1 module (ISI marked) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for PVC rigid concealed conduit (ISI Marked) heavy duty 20mm dia having thickness not less than 1.8mm with all accessories including cutting chases in existing wall for fixing conduit and making good disturbed surface of walls, floors etc with exisitng surface finishes complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 70 Sqmm 3.5 core as per IS-7098 Part-I, XLPE insulated Aluminium conductor heavy duty served with an inner sheathing PVC tape galvanized steel strip or wire armoured with an overall PVC sheathing laid under ground, fixed along wall, through GI pipe under floor/Road including dismantling of existing service cable of any size from electric pole to building, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 50 Sqmm 3.5 core as per IS-7098 Part-I, XLPE insulated Aluminium conductor heavy duty served with an inner sheathing PVC tape galvanized steel strip or wire armoured with an overall PVC sheathing laid under ground, fixed along wall, through GI pipe under floor/Road including dismantling of existing service cable of any size from electric pole to building, complete all as specified and as directed by Engr-in-Charge.
Material and labour for Sand cushioning for underground cable 8cm before laying the cable and 15cm after laying and stretching the cable laid and punned down to form a bed to a minimum 18 cm thickness. The punning shall be done by hand complete all as specified and as directed by Engr-in-Charge (NOTE:- Punned thickness of 18cm shall be considered for measurement purpose only)
Material and labour for well burned bricks, laid flat (old size) sub class B designation 75 for cable protection complete all as specified and as directed by Engr-in-Charge
Material and labour for 50mm dia bore size galvanized steel water tubing pipe (light grade) for protection of cable including suitable size clamps with all fitting and fixed complete to walls and ceilings or laid in floors/fixed to poles/or passing under road crossing, complete all as specified and as directed by Engr-in-Charge
Note: The schedule of credit in Pdf format has been attached with tender and amount of credit schedule i.e. Rs 1,61,933.00 shall be deducted from the total quoted amount of BOQ to arrive at the contract sum.
KEWAL SONS
KULBHUSHAN AGGARWAL
SATISH AND CO
M/S Satpal and co.
D R CONTRACTORS
M/S DUGGAL CONSTRUCTION CO
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .