| 1 | L1₹28.2 LAccepted-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹29.9 L+₹56,060 (1.91%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹29.9 L+₹63,260 (2.16%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹32.5 L+₹3.2 L (10.8%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹33.0 L+₹3.7 L (12.5%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
17 Jul 2024, 6:00 pmClosed
LT COL CHANDRAKANT JOSHI
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPLACEMENT OF EXISTING UG CABLES AND REPAIRS TO LT PANELS REPLACEMENT OF SMDB PANELS INCLUDING IMPROVEMENT OF SUBMAIN WIRING AND ALLIED CONNECTED WORKS AT DFRL MYSORE UNDER GE I R AND D EAST BANGALORE
2024_MES_659528_1
8515/E8
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY b (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹99,000
Yes
21 Sept 2024
20 Jun 2024
24 Jul 2024
20 Jun 2024
17 Jul 2024
5 Jul 2024
20 Jun 2024 - 4 Jul 2024
Amount
Excavation in trenches not.exc 1.5m wide and not exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in soft / loose soil complete all as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance not exceeding 50m and deposting where directed at a level not exceeding 1.5 m above the starting point complete all as directed.
Supply and spread dry river sand in trenches for cable cushioning on both top and bottom of cable including ramming complete all as specified and directed. NOTE :- Punned thickness will be considered for measurement purposes.
Supply and lay burnt bricks sub class 'B' of standard size best locally available laid in trenches for cable protection complete all as specified and directed.
Material and labour for XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor, 1100 volts grade cross sectional area of following sizes complete all as directed. NOTE : (a) The rate is inclusive of testing of cable at site after laying of cables in trenches / walls. (b) The cable may be laid manually and no other means shall be permitted. (c) The quoted rate is inclusive of clamping on walls / pole if required. (d) The earthwork will be measured and paid separately.
4 core x 10 sq.mm
4 core x 16 sq.mm
3.5 core x 25 sq.mm
3.5 core x 50 sq.mm
3.5 core x 70 sq.mm
3.5 core x 95 sq.mm
3.5 core x 120 sq.mm
3.5 core x 185 sq.mm
3.5 core x 240 sq.mm
Material and labour for cutting of road / PCC for laying of UG cables upto a length of 3m complete further laying of cables through GI pipe and filling with PCC and making the surface smooth with the existing surface complete all as specified and directed. NOTE : (a) The quoted rate is deemed to be inclusive of GI pipe of upto 100mm bore. (b) The depth of the cable after laid to be in the same plane as that of the connected earth work. (c) The sides of the GI pipe is required to be sealed properly to avoid moisture.
Material and labour for detecting LT fault upto 0.433 KV through cable fault locator, finding the fault and excavating the earth at that particular location, removing the existing cable and preparing for fixing new cable joints and re laying of cables in the original position and return filling the earth work to make the surface smooth in accordance with surroundings complete all as directed. NOTE : (a) Necessary labour for the earth work upto 10m is deemed to be included in the above quoted rate. (b) Necessary LT Joints will be measured under separate item. (c) Contractor has to commence the job within 3 hrs from the job card assigned to him, failing which penalty @ double the quoted rate will be recovered from the contractor.. (d) The quoted rate is deemed to be inclusive of the hiring of cable fault locator.
Supplying and jointing straight through cable end termination with cold jointing kit complete with all accessories including lugs suitable upto 95 sq.mm 3.5 core XLPE aluminium conductor cable of 1.1 KV grade as required complete all as specified and directed.
Taking down old serviceable cable of capacity upto 300 sq.mm and keeping it in safe custody and further re-laid in the existing trenches / walls as directed and specified. NOTE : (a) The rate is inclusive of testing of cable at site after laying of cables in trenches / walls. (b) The cable may be laid manually and no other means shall be permitted. (c) The quoted rate is inclusive of clamping on walls / pole if required. (d) The earthwork will be measured and paid separately.
Material and labour for scrapping out old wornout painted surfaces and painting with smoke grey epoxy paint to LT panels of any type and size complete all as specified and as directed. NOTE : (a) The quoted rate is deemed to be inclusive of labelling of the MCCBs on the LT Panel as per the existing model. (b) Shutdown for the particular panel needs to be specified well in time (at least a week time).
Material and labour for repairing of the sheet metal enclosure of LT panel complete through welding, screwing complete all as directed and as specified NOTE : (a) The quoted rate is inclusive of replacing of old sheet enclosure of upto 3.15mm thick with new one as required (b) Painting work will be measured and paid separately under relevant items
Material and labour for cleaning of LT panels, scrapping out mud, replacing of sleeves complete, tightening the lugs, insulating the wornout sleeves of cable / busbar with insulating tape complete including repairing of the sheet metal enclosure of LT Panel complete through welding, screwing complete all as specified and as directed. NOTE : (a) The quoted rate is inclusive of knobs, hinges and other locking arrangements required. (b) The quoted rate is excluded to the painting of the replaced sheet. (c) The LT panels needs to be cleaned on every quarterly basis. (d) The quoted rate is inclusive of aluminium / copper lugs required. (e) The quoted rate is inclusive of multistranded copper cable of upto 10 sq.mm (< 10 RM)
Supply and fix MCCBs with thermal magnetic release and terminal spreaders of following capacities in existing LT Panel including disconnecting and removal of old unserviceable ones complete all as specified and as directed. NOTE : (a) The MCCBs needs to be affixed in the existing mounting arrangement of the LT Panel. Any modification required needs to be carried out by the contractor and the quoted rate is deemed to be inclusive of the same. (b) The existing makes of MCCBs in the area are Standard, Havells, Indoasian, L&T (c) The quoted rate is deemed to be inclusive of necessary cable links and cable lugs if required for connections.
4 Pole 400 Amps 36 KA
4 Pole 250 Amps 36 KA
4 Pole 200 Amps 36 KA
4 Pole 100 Amps 36KA
3 Pole 250 Amps 36 KA
3 Pole 200 Amps 36 KA
3 Pole 160 Amps 36 KA
3 Pole 125 Amps 36 KA
3 Pole 100 Amps 36 KA
3 Pole 63 Amps 36 KA
Supply and fix ON-Load changeover switch of following capacities complete including removal of old u/s ones complete all as specified and as directed by Engineer-in-Charge. NOTE : (a) The Changeover switch needs to be affixed in the existing mounting arrangement of the LT Panel. Any modification required needs to be carried out by the contractor and the quoted rate is deemed to be inclusive of the same. (b) The existing makes of changeover switch in the area are Standard, Havells, Indoasian, L&T (c) The quoted rate is deemed to be inclusive of necessary cable links and cable lugs if required for connections
Changeover switch 400 Amps
Changeover switch 250 Amps
Material and labour for servicing of air circuit breaker after disconnecting the cables checking the lever, its tripping mechanism complete and setting the tripping value as directed by Engineer-in-Charge NOTE : The quoted rate is deemed to be inclusive of necessary cable links and cable lugs if required for connections
Material and labour for Air Circuit Breaker 4 pole, 415 V, with thermal magnetic release (manual drawout type) of capacity 630 Amps complete all as specified and as directed. NOTE :- (a) The ACB's needs to be affixed in the existing mounting arrangement of the LT panel. Any modification required needs to be carried out by the contractor and the quoted rate is deemed to be inclusive of the same. (b) The existing makes of ACB in the area are C&S. (c) The quoted rate is deemed to be inclusive of necessary cable links and cable lugs if required for connections.
Supply only the following miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB / LT Panel complete testing and commissioning etc as required.
SP 6A to 32A rating 240/415 V, 10KA 'C' curve.
SPN 32 A rating 240/415 V, 10KA 'C' curve
SPN 40A to 63 A rating 240/415 V, 10KA 'C' curve
TP 25A to 63 A rating 415 V, 10KA 'C' curve
TPN 16A to 32 A rating 415 V, 10KA 'C' curve
TPN 40A to 100 A rating 415 V, 10KA 'C' curve
Material and labour for clamps, angle iron frames for mounting LT Panels and MS duct covers including welding, grinding to make surfaces smooth and painting with two coats of red oxide and one coat of black enamel paint complete all as specified and as directed.
Supply and fix rectangular SMC junction box of size 240 x 130 x 110mm shock proof and rust proof, rot-proof and termite resistant cable entry from bottom and / or sides, 100% weather proof having pole mounting arrangement for street lights / boundary lights complete all as specified and as directed.
Supply and fix rectangular SMC junction box of size 140 x 140 x 95mm shock proof and rust proof, rot-proof and termite resistant cable entry from bottom and / or sides, 100% weatherproof having pole mounting arrangement for garden light all as specified and as directed. NOTE :- The box needs to be affixed in the existing mounting arrangement. Any modification required needs to be carried out by the contractor and the quoted rate is deemed to be inclusive of the same.
Material and labour for service wire (copper) 3 core 1.5 sq.mm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for service wire (copper) 3 core 2.5 sq.mm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for service wire (copper) 4 core 10 sq.mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix SMDB of capacity upto 250A double door 4 way - Main enclosure (with a provision to mount TP MCCBs as an outgoing*) with degree of protection IP-43 complete all as specified and as directed. NOTE :- (a) The quoted rate is deemed to be inclusive of necessary cable links and cable lugs if required for connections. (b) The quoted rate is deemed to be inclusive of necessary brick work and plaster to match with the existing surface complete if required.
Material and labour for aluminium bus bar with sleeves (of suitable colour) and of suitable size including removal of old worn out bus bar complete all as specified and as directed. NOTE : (i) Necessary nut bolt / fasteners and drilling of holes as required deemed to be included in the quoted rate. (ii) For measurement purpose weight of busbar needs to be certified by Engineer-in-Charge at site. The necessary weight measuring equipments needs to be supplied by the contractor as and when directed at site on no cost basis so as to facilitate proper and prompt response.
Supply and fix LT cable route indicator made up of MS with dimensions upto 100mm dia (approx) and embedded letters "433 KV LT MES" complete all as specified and as directed.
RRK PROJECTS
RAHUL ENTERPRISES
Meghana and Gowda Enterprises
Lucky Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .