Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.4 L+₹62,117 (1.52%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹42.4 L+₹1.6 L (3.96%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹42.9 L+₹2.2 L (5.31%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹44.2 L+₹3.5 L (8.57%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹47.4 L
EMD Value
₹94,800
Closing Date
26 Dec 2024, 6:00 pmClosed
GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
PROVISION OF DEFI GEYSERS TO JCO/OR MD ACCN, 10 KVA UPS FOR SAFETY PROTECTION AT AUDITORIUM AND PROVN OF 1 X SPLIT AC 2 TON FOR NFS PROJECT IN NEW CANTT PRAYAGRAJ UNDER GE WEST PRAYAGRAJ
2024_MES_686085_1
8798/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NEW CANTT PRAYAGRAJ
As per tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹94,800
Yes
17 Mar 2025
28 Nov 2024
2 Jan 2025
28 Nov 2024
26 Dec 2024
12 Dec 2024
Amount
Supply, Fixing & testing Geyser electric water heater, storage type steel body with heating element upto 2KW, BEE 5 star rated, 25 Ltr capacity with all accessories such as safety valve, thermostat, NRV, PVC connection pipe heavy duty hot water supply (wired)-01 No and inlet cold water pipe complete of size 600mm length-01 No incl grouting of suitable anchor nuts, bolts not less than 10mm dia and 100mm long as per site requirement and all other accessories for fixing of geyser electrically, plumbing complete all as specified and directed.
S&F 15mm bore GI Steel water tubing 'medium grade', laid / fixing concealed on wall, surface on tiles / floor etc with all fittings like elbow, tee, socket, bend etc and making good surface match with existing complete all as specified and directed.
S&F angle stop valve copper alloy , fancy type, high pressure, chromium plated with long shank and cup (Concealed type) with crutch or butterfly handles screwed down both ends for iron pipe or for unions for 15mm dia of pipe complete all as specified and directed.
S&F 15 mm bore bib taps, cast copper alloy, fancy type brass chromium plated with screwed down, screwed for iron pipe or for brass ferrule including all accessories complete all as specified and directed.
M&L for concealed sub main wiring using FRLSH PVC insulated, unsheathed stranded copper conductor cable two single core of size 6.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm as earth continuity conductor complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
S&F modular socket 16 Amp with 20 Amp SP MCB 'B' series including 3 M metal enclosure with grade with cover plate white colour complete all as specified and directed.
S&F modular switch 16 Amp 1 module with 2 M metal box and grade with cover plate white colour complete all as specified and directed.
Supply, installation and testing of microprocessor control online UPS of 10 KVA capacity with output voltage rating 10000VA, 8000 Watt and DC volts 196 V, ± 3% variation and nominal out put voltage 230V, nominal input voltage 380/400/415 V with minimum 16 Battery required as per capacity required, no load, high line to low line frequency 50 Hz ± 0.5 Hz sine wave output from protected with internal electronic overload protection, 30 min battery backup including maintenance free (AGM), battery of 12V including interconnection complete all as specified and directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used TPN 4 ways, 415 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surface near DBs of cables/wires complete all as specified and directed. (For UPS connection only)
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & Neutral, 40 to 63 Amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB Triple pole & neutral 100 Amp, 415 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC casing and caping not less than 20mm wide med grade ISI marked with all fixing accessories , using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surfaces complete for one 3 pin 5 Amp socket outlet, independent, with cables 1.5 Sqmm earth wire complete all as specified and directed :- Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire
All as per Srl item No. 13 above but for one 3 pin socket outlet 15 amps, independent, with cables 2.5 sq. mm size on independent board with 2.5 Sqmm earth wire.
S&F modular Switch piano flush type single pole one way 6 amps complete all as specified & directed.
S&F modular Switch piano flush type single pole one way 16 amps complete all as specified & directed.
S&F modular socket outlet 2 in 1, 2/3 pin, 2 module 6 Amps flush type universal complete all as specified & directed.
S&F modular Socket out let 2 in one, 5/3 pin 5 & 16 Amp 2 module complete all as specified & directed
S&F Modular white cover plate with frame of 3 module complete all as specified & directed
S&F Modular metal flush box of 3 module complete all as specified & directed
S&F HDMI cable with standard size of minimum length 5-7 mtr from control panel to projector, CPU, Monitor etc complete all as specified and directed.
S&F PVC/ Polycarbonate box / Gang box of suitable size for 3 pin 5 / 15 Amp socket with switch - 03 Nos and 5 Amp switch with socket - 03 Nos complete one board all as specified and directed.
M&L for concealed sub main wiring using FRLSH PVC insulated, unsheathed stranded copper conductor cable two single core of size 4.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm as earth continuity conductor complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
M&L for concealed sub main wiring using FRLSH PVC insulated, unsheathed stranded copper conductor cable two single core of size 10.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor of size 10.0 Sqmm as earth continuity conductor complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
M & L for earthing complete with Galvanized Steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to and including GI iron strip of size 32x6 mm flat by means of GI bolts, nuts, and washers, protected by 40mm bore GI light grade ISI marked pipe upto and including test points. Earthing plate shall be surrounded by alternate layers 15cm thick of charcoal or coke and common salt all around bottom and top, 20mm dia GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C2 (using 20mm graded crushed store aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceed ing 50 M, pit cover 40 mm thick made with RCC (1:2:4) type B-1 (using 20mm graded crushed store aggregate) including TMT reinforcement 80 mm dia @ 75 mm C/C both way, MS handle of 12 mm dia, cover rest on MS angle iron frame 40x40x6mm embedded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, including frame funnel, wire mesh GI earth wire, 8 SWG under the earth fixed upto 7.5 Mtr length protected by 15 mm GI pipe (light grade) fixed to UPS on roof top of auditorium building complete all as specified and as shown in electrical plate No-3 of SSR Part-I and all as directed.
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit pipe complete all as specified & directed
Supply, installation, testing and commissioning of hi wall split AC units 2.0 TR indoor/outdoor unit comprising of inverter type complete with cordless remote control unit with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2. of capacity as shown and the indoor units shall be mounted at a suitable height and outdoor unit shall be mounted on wall bracket or on a raised platform of suitable length and width as per site condition and contractor shall be supplied along with the required length of refrigerant piping and drain piping and control cable etc and all finishing works like packet filling, wall surfacing work or any other Civil work from inside or outside of building shall be completed all as specified and directed.
S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 20 amps, C series 240 volts AC complete all as specified & directed.
S & F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250 V with out put voltage stabilizer at 230 V with accuracy of +/- 2.5% and of capacity 5 KVA complete all as specified & directed.
Krishna Enterprises (BID ID -3193352)
M/S MALHOTRA ENGINEERING WORKS (BID ID -3193151)
Avion Industries (BID ID -3193503)
P S TRADERS (BID ID -3193270)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .