| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹38.6 L+₹6.1 L (18.9%)Rejected-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹43.0 L+₹10.5 L (32.4%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹43.2 L+₹10.7 L (32.9%)Rejected-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹44.9 L+₹12.4 L (38.3%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹42.6 L
EMD Value
₹85,200
Closing Date
8 Jan 2024, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI-88
REPAIRS TO DAMAGED PERIMTER SECURITY WALL, AREA DRAINAGE HARDSTANDING AT WED, DSRV AND DOOR TO DOOR AND CERTAIN MAINT WK AT SPDC, WED, NSD, DSRV AND CLEARNING OF SEWAGE LINE MANHOLE SEPTIC TANK AT SPDC, WED, NSD UNDER GE (NW) MANKHURD
2023_MES_625108_2
8253/E8
Open Tender
Civil Works
Item Rate
210 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹85,200
15 Feb 2024
23 Dec 2023
10 Jan 2024
23 Dec 2023
8 Jan 2024
23 Dec 2023
Amount
Excavation in trenches, not exceeding 1.5m wide and n.exc 1.5m in depth for sewage line and getting out in hard/dense soil.
-- Ditto -- all as per item No 1 above but exc 1.5 Mtr but n.exc 3.00 and getting out in hard/dense soil.
M & L for plain cement concrete 1:3:6 type C2 as in bed to drain pipe, 300mm bore including packing under and haunching against the sides of pipes after they are laid and tested including necessary shuttering and supports to concrete
M & L for plain cement concrete 1:3:6 type C2 as in bed to drain pipe, 200mm bore including packing under and haunching against the sides of pipes after they are laid and tested including necessary shuttering and supports to concrete
M & L for plain cement concrete 1:3:6 type C2 as in bed to drain pipe, 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested including necessary shuttering and supports to concrete
M&L reinforced concrete pipe class NP 2 laid and jointed complete with collars 300 mm dia
M&L reinforced concrete pipe class NP 2 laid and jointed complete with collars 200 mm dia
M&L reinforced concrete pipe class NP 2 laid and jointed complete with collars 150 mm dia
M&L in Repairs for 200mm internal dia sail glazed stone-ware drain pipe Grade'A' laid in trenches and jointed complete all as specified and directed.
M&L in Repairs for 150mm internal dia sail glazed stone-ware drain pipe Grade'A' laid in trenches and jointed complete all as specified and directed.
Returning, filling including spreading, leveling watering and well ramming in layers n.exc 25cm in hard/dense soil complete all as specified and directed by Engr-in-Charge..
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
Labour for cleaning /clearing of blockage of gully traps, floor traps, vertical and horizontal soils/ waste pipe of different dia and sewage lines( PVC/SGW/ CI/RCC of any dia) except cleaning of manholes including opening inspection eye door of bend/ branch pieces, rodding till smooth flow and refixing of door after cleaning and any other cleaning work as directed by engr-in-charge in the area of the SPDC,NSD MANKHURD, WED MANKHURD under GE (NW) Mankhurd Note: (a) Contractor's labour will report daily at 0845 hrs on all working days at online complain cell centre and attend complaints given by Engr -In- Charge . Complaints needs to be cleared within 24 hrs after receiving the complaints . The contractor will deploy requisite labour and supply all T&P ( mechanical Iron rods, knot ropes , bamboo etc) scaffolding ladders and necessary safety measures such as gas mask, use of safety belt and cell torch etc and any other materials required to clear the blockages at the site without any extra cost . In case any labour does not report to Engineer In Charge for the whole day or found missing more than half an hour on any day, Panel recovery @ RS.860/- per head per day shall be made proportionally from contractor's dues. b) The above item includes conveyance cost of labour with their tools to travel from one area/location to other area/location to attend complaints, plugging of sewer and diverting flow of sewage if necessary to carry out the work and removal of sludge from the site to outside MOD land (The department shall not be liable to provide any kind/form of transportation to the labour). (c) Registers of labour attendance and complaints shall be maintained by contractor at their own cost,which shall be kept in the custody of MES Department(complaint cell) duly signed by contractor's representative ,JE(civil) and Engineer in charge.
Cleaning manhole of size n.exc 1.50 Sqm by taking out sludge in semi liquid/solid stage (incl. all water etc) from inside of manhole of depth not exceeding 1.5 m and removing the sludge to a distance not exceeding 50m depositing in trenches including supply and sprinkling bleaching powder and covering sludge with earth to a thickness not less than 30 cm including all earth work, returning filling, removal of surplus soil & necessary temporary cleaning and necessary safety measures such as gas mask, use of safety belt etc as directed by the Engineer-in-Charge.
Opening cover of manhole/septic tank exc 1.5 m depth, dewatering and pumping out night sludge etc from septic tank by mechanical means and removing sludge outside MD land and cleaning the septic tank as per BMC rules and placing the cover in original position taking all precautionary and safety measures all as directed. Note: All T&P and transportation for carrying sludge shall be provided by the contractor at their own cost.
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc. and M&L for brick work with subclass 'B' bricks straight or curved on plan exceeding 6mtr mean radius built in CM 1:6 complete all as specified.
Taking down cement plaster of any description from brick or stone walls including raking out joints, hacking for key , scrubbing down with water etc complete all as specified
M & L for rendering 15 mm thick using polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provision of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements
M&L for Preparing surfaces plastered or unplastered and applying applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M & L for cement concrete 1:2:4 , type B-1 (using 20mm graded stone aggregate) as in coping including necessary form work.
M & L for precast reinforced cement concrete M-30 (20mm graded aggregates) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed. (Note :- Reinforcement shall be measured and paid separately).
S & F for CRSl deformed or twisted bars 10 mm dia and over, cut to length, bent to shape required including mild steel wire (annealed) not less than 0.9mm dia complete all as specified.
M&L for plain cement concrete 1:3:6 (type C2), using 40mm graded stone aggregates mixed with water proofing compound @3% by weight of cement for fixing of nahani or floor traps, bedding in manholes, sunken floor complete all as specified and directed by the Engineer-in-charge Note: Water proofing compound shall be measured and paid separately
Supply only intergal water proofing compound. (ISI marked).
M&L for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including removing the old one etc complete all as specified and directed.
Demolition of cement concrete in any description or in any position (below or above ground level).
M & L for 50mm thick cement concrete 1:3:6, type C -2 as in plinth protection and PCC path, finished the suface even & smooth without using extra cement including necessary form work finishing exposed edges fair complete all as specified.
M & L for PCC type D2 1:4:8 using 40 mm graded aggregate as in foundation, filling and mass concrete
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured 450x300x6mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with the colour of tiles, over and including 10mm thick cement mortar backing coat in CM 1:3, complete all as specified and directed.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with nthe colour of tiles, over and including 15mm thick cement mortar screed bed in CM 1:4, complete all as specified and directed.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.11 Sqm but not exceeding 0.16 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with nthe colour of tiles, over and including 15mm thick cement mortar screed bed in CM 1:4, complete all as specified and directed.
Preparation of old surfaces on walls (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
All as per item No 32 above but on ceiling.
Preparation of old surfaces on walls (plastered or unplastered or previously colour washed) and applying one coat of Colour wash complete all as specified.
Preparation of old surfaces on walls (plastered or unplastered or previously distempered ) and applying one coat of Oil bound distemper complete all as specified.
M & L for preparation of old wooden surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M & L for preparation of old steel surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M & L for preparation of old Steel surfaces of any description n.exc 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M&L for complete removal of existing treatment by washing, rubbing down and stopping of old decorated surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and levelling with minimum 1 mm thick white cement based wall care putty for obtaining plain surface complete all as specified and directed.
M & L for preparation of old surfaces for applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over old surfaces
M & L for complete removal of existing treatment and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over old surfaces
Removal of plant growth from wall/roof projection or along the soil /rain water down pipe at any level by injection with chemical Glyphospate solution (410 concentration) of 20mm or till rufuse by cutting or injection in stem of plants or roots at 30mm inclding scafolding upto any ht.
M&L for cement concrete type E-2,1:5:10 (using 40 mm graded aggregate) as in sunken portion of toilet and bathroom complete all as specified and directed.
M & L for special treatment for sunken portion of WC bath toilet kitchen etc executed in following stages stage 1 providing 15 mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr fixit or shalicrete R of STP ltd in the proportion/quantity all as per manufacturers instructions stage 2 Application of 1 st coat of tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces Stage 3 Application of 1 st coat of tarfelt LM of STP Ltd (without dilution with water) @ 1kg/sqm by brush all as per manufacturers instructions. Stage 4 Laying fibre glass cloth ( weight not less than 50 gm/sqm) over 1 st coat while the coated surface is still sticky Stage 5 After 6 to 7 hours iterval, apply second coat ie final coat of tarflet LM of STP ltd (without dilution with water) @ 1 kg/sqm by brush as per manufacturers instructions. Stage 6 Providing 10 mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250 ml/50Kg cement all as per manufacturer's instructions. Stage 7 Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion. Notes: (i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid.
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white with integral foot rests with flush pipe of 32mm dia including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete.
S&F in repairs vitreous China wash basin white, flat back size 550 x 400mm including 15mm dia fancy type pillar tap of Make ESSCO Model no DLX-507KN or equivalent of make Parko as approved by the GE, , chromium plated CP waste coupling, chain and plug, waste fitting, union and waste pipe 32mm dia of required length and all necessary 450mm long outlet and inlet PVC connections pipes with PTMT check nuts complete.
S&F in repairs vitreous coloured China Europeon water closet (Pedestal Pattern) including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete. Jaquar Essco Model No of EWC - ECS-WHT-551SNPP183LZ or ECS-WHT-551PNPP183LZ
S&F in repair Health faucet with 1 mtr tube & hook complete all as specified and directed.
S&F in repairs two way Bib cock long body with wall flange fitted by 15mm bore complete all as specified and as directed
S&F Bib tap standard of bore 15mm of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms)
S&F Pillar taps of bore 15 mm of PTMT any colour fancy type high pressure screwed for iron pipe and fixed.(Minimum weight 15gm-120gms)
S&F Stop valve of bore 15mm of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms/ 20mm 92gms)
S&F Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms)
S&F Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms)
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm and Supply & fixing 15 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm and Supply & fixing 20 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25mm and Supply & fixing 25 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 20mm bore complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 15 mm bore complete all as specified and directed.
S & F in repairs PVC (SWR) bend 75 mm with access door
S & F in repairs PVC (SWR) bend 75 mm without access door
S & F in repairs PVC (SWR) bend 110 mm with access doors
S & F in repairs PVC (SWR) bend 110 mm without access doors
S & F in repairs PVC (SWR) branch piece, single (single) Y equal or unequal,75 mm without access door
S & F in repairs PVC (SWR) branch piece, single (single) Y equal or unequal,75 mm with access door
S & F in repairs PVC (SWR) branch piece, double (double) Y equal or unequal,110 mm without access door
S & F in repairs PVC (SWR) branch piece, double (double) Y equal or unequal,110 mm with access door
S & F in repairs PVC (SWR) branch piece, single (single) Y equal or unequal, 75mm without access door
S & F in repairs PVC (SWR) branch piece, double (double) Y equal or unequal, 75mm with access door
S & F in repairs PVC (SWR) branch piece, single (single) Y equal or unequal, 110 mm without access door
S & F in repairs PVC (SWR) branch piece, double (double) Y equal or unequal, 110 mm with access door
S & F in repairs PVC (SWR) junction single (single T) equal or unequal,75mm without access door
S & F in repairs PVC (SWR) junction single (single T) equal or unequal,75mm with access door
S & F in repairs PVC (SWR) junction single (single T) equal or unequal, 110mm without access door
S & F in repairs PVC (SWR) junction single (single T) equal or unequal, 110mm with access door
S & F in repairs PVC (SWR) junction (double T) equal or unequal,75mm without access door
S & F in repairs PVC (SWR) junction (double T) equal or unequal,75mm with access door
S & F in repairs PVC (SWR) junction (double T) equal or unequal, 110mm without access door
S & F in repairs PVC (SWR) junction (double T) equal or unequal, 110mm with access door
S&F PVC (SWR) vent cowl 110mm bore with and including rubber ring joints, complete all as specified and directed.
S&F PVC (SWR) vent cowl 75 mm bore with and including rubber ring joints, complete all as specified and directed.
S&F PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors in repairs
S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors in repairs
S&F PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to walls in repairs
S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls in repairs
M&L PVC (SWR) floor trap with outlet dia 75mm, plain with grating including jointing with solvent cement
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm including exterior wall care putty over new surfaces Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provision of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour Preparation of new plastered surfaces on ceiling and applying three coat of white wash complete including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provision of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on concrete surfaces etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 5mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour Preparation of new plastered surfaces on ceiling and applying three coat of white wash complete all as specified. and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provision of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provision of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 15mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 4mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour Preparation of new plastered surfaces on ceiling and applying three coat of white wash complete all as specified. and directed. including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed.
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 4mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 5mm thick polymer modified ready mix cement based plaster on ceiling complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including Preparation of new plastered surfaces and applying three coat of white wash complete all as specified.
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 4mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed.
M&L for forming V grooves in plaster n exc 5 mm deep and n exc 5 mm on face and filling cracks with crack X paste of M/s Dr fixit or with eequivalent of M/s STP Ltd including necessary scaffolding upto 15mtr height
M&L for Providing waterproofing treatment as specified below and at any height of roof surface including removal of watertank, plumbing line during waterproofing making good if any holes and refixing the same as directed by Accepting officer and Engineer in charge complete 1) Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc outside MD land complete all as specified and directed by the Engineer-in-charge 2) M&L for averaging 50 mm thick PCC 1:2:4, type -B-1, using 20mm graded stone aggregated as in padding concrete of roof mixed with WPC in the proportion as recommanded by the manufacturer(s), complete all as specified and directed, 3) M&L 10 mm thick Screed bed or bedding layer in CM (1:3) with WPC when the concrete is still green complete all as specified and directed. 4) M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a). The roof surface shall be throughly wire brushed cleaned to eliminate all sharp projection, washed dried upto and cleaned overall foreign material and dust to receive primer. (b). The dry surface shall be primed with Torch shield primer as per manufacturer’s instructions, manufactured by the same agency as that of APP membrane. (c). Providing and laying APP modified polyester reinforced water proofing membrane with minimum weight of 3.5 Kg/Sqm, as specified here-in-before. (d). The APP membrane shall be laid using torch-on butane application with minimum 10 cm side overlap and 15 cm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane. (e). The APP membrane shall be taken up to minimum 200 mm on vertical surfaces. The edge of the membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant.
Petty repairs to wooden joinery / PVC doors/aluminium windows works such as Resecuring or easing and adjusting of doors, windows kitchen cabinets in any size, refixing hinges etc by providing glue nails and screws to the satisfaction of user and rectifying other misc minor carpentary works assigned by the Engineer In charge. (Note : Replacement of builders hardware if required shall be measured and paid separately under relevant item) Note item No 1 and 2 : (a) Rep of contractor will collect details of complint from departmant. The contractor will be alloted complaint on daily basis and sufficient resources will be deployed by him/her for completion of day to day comaplaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit suitable penalties as mentioned in relavant clause of Contract. (b) A detailed log of complaints with completion/ non-completion remarks from users/MES will be maintained by the contractor and same will be updated on daily basis in consulatation with Engr-in-Charge or JE detailed by him. (c) The contractor will make suitable arrangment for emergent complaints and will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The quoted rated deems to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Naval Depo. (e) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed peridically by Engr-in-charge to streamline complaints disposal system.
Petty repairs to plumbing/internal water supply works such as repair to leaking bib taps, pillar taps, mixers stop cocks by tightening and providing spindle,washer repairs to float valves, low leveled cistern to the satisfaction of user as assigned by the Engineer In Charge.
Suply only stainless steel butt hinges, 100mm, medium weight complete all as specified and directed
Supply only stainless steel butt hinges, 75mm, medium weight complete all as specified and directed
Supply only stainless steel butt hinges, 50mm, medium weight complete all as specified and directed
Supply only aluminium, anodised, barrel tower bolts of extruded section of size 200mm complete all as specified and directed.
Supply only aluminium, anodised, barrel tower bolts of extruded section of size 150mm complete all as specified and directed.
Supply only aluminium, anodised, barrel tower bolts of extruded section of size 100mm complete all as specified and directed.
Supply only extruded aluminium alloy handles, fabricated type of size 100mm in any position complete all as specified and directed.
Supply only extruded aluminium alloy handles, fabricated type of size 150mm in any position complete all as specified and directed.
Supply only floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring of length 140mm fixed in floor etc complete all as specified and directed.
Supply only stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with in wooden windows, doors etc and including M&L for fixing of teak wooden beading of suitable size all around complete all as specified and as directed by the Engineer-in-Charge.
Supply only for aluminium alloy anodised sliding door bolt with hasp and staple(bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolt of extruded section of size 300 mm fixed at any position all as specified and directed.
Supply only 4 levers aluminium Mortice lock size 100 mm
Supply only aluminium (Die cast body) hydraulically Door closer regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg all as specified and directed.
Supply only anodised aluminium alloy curtain rods with fixing brackets, stops, rollers etc all as specified.
Supply only10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, of suitable length as per site requirement connecting to WC etc, complete all as specified and directed.
Supply only CP stop cock 15mm bore fancy type chromium plated with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply only CP bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
Supply only CP pillar taps 15mm bore, cast copper alloy, chromium plated fancy type complete all as specified and directed.
Supply only waste fitting of 32 mm bore brass, chromium plated for glazed ware wash basin etc complete all as specified and directed.
Supply only waste fitting of 40 mm bore brass , chromium plated for glazed ware for sink coulpling etc complete all as specified and directed.
Supply only waste pipe for WHB 32mm bore fixed to wash hand basin coupling length pipe 0.90 mtrs each complete all as specified and directed.
Supply only waste pipe for kitchen sink 40mm bore fixed to sinks coupling length pipe 0.90 mtrs each complete all as specified and directed.
Supply only stainless steel grating in round shape 100mm dia complete all as specified and directed.
Supply only stainless steel grating in round shape 100mm dia with one hole for waste pipe complete all as specified and directed.
Supply only plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device etc complete all as specified and directed..
Supply only low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc.
Supply only chromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc.complete all as specified and directed.
Supply only soap dish complete all as specified and directed.
Supply only Health faucet with 1 mtr tube & hook complete all as specified and directed.
Supply only two way Bib cock long body with wall flange fitted by 15mm bore complete all as specified and as directed
S&F aluminum anodised grill DG- 104 of Deco grill or equivalent fixed with 'F'/'U' section approved make all as specified and directed. Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
Taking down plaster and M & L for rendering 10mm thick using polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provision of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements
M&L for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on old surfaces of walls etc, finished even and smooth, complete all as specified and directed.
Supply only 15 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
Supply only Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
Supply only 4.8mm thick Sheet glass, ordinary quality
Supply only 3mm thick pinhead type glass Note : A sum of Rs.19,067/- towards sch of credit shall be deducted to arrive the contract sum.
joshua construction
H R ENGINEERS
Vishal Builders
RAJU AND COMPANY
mp construction co
Joy builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .