Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
8 Sept 2026, 3:30 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less ; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. : Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any Signalling work involving trenching, cable laying, termination and outdoor wiring. Note 1: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/ 40 / 60% (as the case may be) criteria of similar nature of work.
22 conditions · 13 needing a document upload
PAN card Copy should be enclosed.
Please submit the copy of the registration certificate as applicable, GSTIN certificate should be enclosed.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Firm has to submit authorization letter for uploading documents on IREPS in case he/she is not an authorized person.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc.Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc. are not allowed.
Copy of PAN number and GSTIN number should be submitted.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void.
(i)Tenderers will examine various provisions of the Central Goods and Service Tax Act, 2017(CGST)/Integrated Goods and Service Tax Act,2017(IGST)/Union Territory Goods and Service Tax Act,2017(UTGST)/respective states State Goods and Service Tax Act(SGST) also, as notified by Central/States Govt. and as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit(ITC) likely to be availed by them is duly considered while quoting rates. (ii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iii) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism(RCM) and deposit the same to the concerned authority.
Tenderer should go through Annexure 1 & 2 of Tender Notice (attached in Tender Document)for list of documents required to be uploaded along with the offer.
Replacement of defective signalling cable and protection of signaling cable lying on bridges over LKO Division of Northern Railway.
106-Sig-Tender-31-2026-27~NR
106-Sig-Tender-31-2026-27
Open
Works - General
240 Days
Lucknow, Uttar Pradesh
₹0
₹3.0 L
18 Aug 2026
18 Aug 2026
25 Aug 2026
67 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,47,54,587.47 | ||
| — | 30000.00 | — | — | ||
| Excavating and refilling of trench to the level of ground with rammed earth asper Drg. No.(NR/S&T/Con/1.1/97A) so as not to form a drain 0.3 Mtrs wide & 1mtr deep on both side of the station along side thetrack. It shall conform to the safe distance as per signalling and cable plan in all type of soil, it also includes clearence of roots of trees and bushes. | — | — | — | 13,27,800 | |
| — | 160000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per attached guidelines (Drg. No.(NR/S&T/Con/1.1/97A) or latest on signalling cable laying and as per cable route plan approved by Railways through trenches, RCC pipe, DWC pipe, GI pipe etc and meggering of cable before and after its laying of all type of outdoor cables. Contractor have to transport cable from any store of LKO division to site carefully. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to Railways, as per instructions by Consignee. | — | — | — | 8,70,400 | |
| — | 240000.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/Con./1.1/97A) and as per instruction of the site Engineer | — | — | — | 13,99,200 | |
| — | 20.00 | — | — | ||
| Shifting of Exposed cables. The item includes Removal of exposed cable from existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe covered separately. | — | — | — | 1,48,369 | |
| — | 700.00 | — | — | ||
| Boring and trenchless cabling along with supply and insertion of HDPE/DWC self lubricated pipes as per RDSO Spec no. RDSO/SPN/204/2011 Ver 1.1 or latest of 120mm nominal dia in the bore at the depth of 1.4 meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and as directed by Engineer Incharge by trenchless technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. Inspection-RITES for Supply of DWC/HDPE pipe. The following required coupling arrangement should also be supplied: 1. Suitable snap fit couplers with rubber O ring, 2. Spacers, 3. Tees. 4. Bend. 5. End Cap(1 no. =6mtr ,Straightpipe). (A) The cost shall include horizontal boring through any intermediate obstruction, either natural or man made or any boundary etc. (B) The rate is inclusive of all the materials equipment and labour required for during trenchless horizontal boring under the railway track. Nothing extra shall be admissible on any account than the rate quoted above. (C) The Pipeis to be laid under railway track/road /culvert. All necessary arrangement are to be provideand all precautions are to be end is not deviated from the horizontal level line by more than 250mm in horizonta land vertical direction. (D) The rate shall be inclusive of direction and protection of underground utilities encountered during boring. (E) The payment for boring shall be made only when DWC/HDPE pipe are laid in the bore | — | — | — | 9,14,543 | |
| — | 1000.00 | — | — | ||
| HDD boring and trenchless of 120 mm bore dia without HDPE pipe for laying in the bore at the depth of minimum 1.4 meter from formation level (level of earth below ballast) as directed by Engineer Incharge by HDD technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. | — | — | — | 9,79,270 | |
| — | 1500.00 | — | — | ||
| Supply & fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 or latest with coupling on culverts bridges as per Drg. No. NR/S&T/CON/1.4/97 or latest drawing, or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection- RITES for supply portion | — | — | — | 18,32,775 | |
| — | 300.00 | — | — | ||
| Supply and fixing of GI Pipe as per specification No. IS:1239 (ISI Mark) make Jindal/Tata/Ajanta or Similar, size 75mm dia 3mm thick perforated at a distance of 20 cm or less of required length at culvert/bridges/along the cuttings, , suitably concreted at both ends as per drg. No. (NR/S&T/CON/1.4/97) to be filled with chattered compoun. GI pipe clamps of MS flats, bolts and nuts, chattered compound to be supplied by contractor. Inspection- Consignee for supply portion | — | — | — | 2,67,171 | |
| — | 250.00 | — | — | ||
| Supply & fixing of GI troughing & Channel on girder bridges for carrying cables. Fixing of channel with Girder to be done with hook/ 'J' bolts of suitable size to held the load of the troughing. Drg. as per SEM. This item also includes the filling one layer of Bitumen compound as per extant practice. (ii)Supply and fixing of GI troughing of size trough 150mm x 200 mm x 2000mm. Inspection: Consignee for supply portion | — | — | — | 2,49,180 | |
| — | 50.00 | — | — | ||
| Supply and installation of earth electrodes as per std.practice. The item includes digging of pitin earth, 3 Mtrs. deepand fixing earth electrode pipe.Casting of cement concrete enclosuresas per drg. No.(NR/S&T/CON/6.4/97)or latest. The soil treatment shall bedone as per std.practice. The item includes provision of mild steel flat of size35mm x 6mm (as per IRSEM) and nutbolted connection of MS flat with earth electrode. The otherend of mild steel flat to be connected to block instrument,cable sheath of power equipment, signal base, apparatus case,CT rack / relay racks,other equipments as per the instruction of Engr. at site & IRSEM.Earth connection Signal & location boxes to be doneDrg.No. 19-D6 of IRSEM App II orlatest. Complete materials such as earth electrodes asper Drg. No. (NR/S&T/CON/6.3/97)or latest , cement,wiring material, nutbolt for connection &mild steel flat of size minimum 35mm x6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection by - Consignee for supply of earth electrode. | — | — | — | 1,62,688.5 | |
| — | 500.00 | — | — | ||
| Supply & installation of HDPE Double Walled Corrugated (DWC) Pipe as per RDSO Specification No.RDSO/SPN/204/2011 Ver. 1.1 With Amndt-1 (outer dia 120 mm 6m st. length with one coupler for every 6m length). This include brick work and other arrangements required to secure the pipe as per specifications, drawings andstipulations of tender documents and as per approved cable route plan including road crossing/platform/trackcrossing and for bridges and culverts etc. Inspection by- Consignee for supply portion. | — | — | — | 2,62,390 | |
| — | 1000.00 | — | — | ||
| Earth work for excavation and refilling around location boxes and signals etc. where necessary including 50M lead and 1.5M lift. The lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. The earth work should be well rammed including breaking of clods, levelling and dressing etc. as per instruction of Engineer at site. | — | — | — | 1,55,900 | |
| — | 50.00 | — | — | ||
| Brick work with well burnt bricks in foundations and plinths with cement and sand (ordinary) mixture of 1:4 ratio. All material is to be supplied by the contractor. (Inspection: Engg representative of railway) | — | — | — | 1,32,222 | |
| — | 50.00 | — | — | ||
| Concreting unschduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand ratio. It also includes the excavation of earth as required at site and as per instruction of site incharge. The volume in cubic metres shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. Cement coarse sand and aggregate 25mm are to be supplied by the contractor. | — | — | — | 1,85,817.5 | |
| — | 25.00 | — | — | ||
| Supply of Apparatus case steel Single with 'E' type locks and key ward No 42 complete as per drawing No. RE/S&T/ALD/SK/219/82 & 221/82 or latest. Handle should be at the rate of one each 4 nos. appratus case. Inspection : Consignee | — | — | — | 4,71,393 | |
| — | 25.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of App. Case single as per Drg. No (NR/S&T/ Con/2.7/97). A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress of water in the base of location box.All material such as cement, sand, aggregate & anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting the cable for termination. | — | — | — | 1,06,291.25 | |
| — | 25.00 | — | — | ||
| Preparation of App. Case single not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials such as teakwood shelf, hylum board, salwood plank, angle iron, square bar, nuts & bolts etc. shall be supplied by the contractor and shall be as per the RDSO specn. (as applicable). ARA terminals & HRC fuse will be supplied by the Railway. | — | — | — | 1,15,220.5 | |
| — | 20.00 | — | — | ||
| Supply of apparatus case steel half with 'E' type locks and key ward No. 42 as per Drawing No. RE/S&T/ALD/SK/220/82 & 221/82 or latest. Handle should be at the rate of one each per 4 Nos apparatus case. Inspection: Consignee | — | — | — | 3,16,718 | |
| — | 20.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of app. Case half as per Drg, No (NR/S&T/ Con/2.8/97). A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, sand, aggregate & anchor bolts shall be supplied by the contractor.Contractor is required to execute all type of repair work of foundation if required during inserting the cable for termination. | — | — | — | 89,654 | |
| — | 20.00 | — | — | ||
| Preparation of App. Case half not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials such as teakwood shelf, hylum board, salwood plank, angleiron, square bar, nuts & bolts etc. shall be supplied by the contractor. ARA terminal & HRC fuse will be supplied by the Railway. | — | — | — | 66,886.8 | |
| — | 3000.00 | — | — | ||
| Termination of all the cores of all type of outdoor cables after its laying on both end.This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also includes dressing and lacing of cables on both ends.Proforma for testing and material for lacing to be supplied by the contractor. | — | — | — | 33,720 | |
| — | 7000.00 | — | — | ||
| Supply of terminal block M-6 (ARA terminals) Block 25mm centre small M-6 terminal made of PBT as per IRS spec. No.IRS-S-75/2006 (Rev.2) or latest & IRS drawing No.SA-23741/A (Alt. 4) or latest. Inspection: RDSO | — | — | — | 4,61,300 | |
| — | 800.00 | — | — | ||
| Fixing of ARA terminals / Wago terminals / fuse blocks with provision of holes on hylum sheets and fixing by galvanised nuts and bolts. This includes provision of two additional holes on hylum board on either side for cable conductor entry. The work shall be done as per the instructions of Railway representative at site. | — | — | — | 11,664 | |
| — | 2500.00 | — | — | ||
| Supply of 4 conductor dis-connect terminal block for test and measurement 0.8 sq.mm-2.5 sq.mm centre marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carreir rail DIN 35 front entry cage clamp connection Grey wago or similar as RDSO/SPN/189/2004 Rev. 3.0 or latest. Material to be supplied from RDSO approvedfirm. Inspection : RDSO | — | — | — | 3,26,875 | |
| — | 50.00 | — | — | ||
| Supply of Steel carrier Rail 35x7.5mm/0.039 in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection : Consignee | — | — | — | 7,173.5 | |
| — | 200.00 | — | — | ||
| Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection : Consignee | — | — | — | 3,628 | |
| — | 200.00 | — | — | ||
| Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection : Consignee | — | — | — | 3,050 | |
| — | 2.00 | — | — | ||
| Supply of cable fault locator for underground mettalic S&T cable of reputed make 3M Dynatel /Andig/Aplab/ Stanley /RD or similar reputed make specification similar to (Test signal output1/2 Sine, Pulse width 5nsec to 2500 nsec, Max Range:15000m, Filter cut-off Frequency:150 kHz (High Pass Filter), Gain:0 to 63dB), RDSO/TEC recommended.Item to be supplied after successful demonstration and approval of railways. Visual Inspection by RITES against test certificate & guarantee certifcate of OEM | — | — | — | 7,16,276.1 | |
| — | 1500.00 | — | — | ||
| Fabrication, supply and fixing of concrete cable marker as per RDSO drg. No. SDO/Cable Laying/020,dt.31.10.11 or as per SEM or latest drawing given by engineer The marker shall be fixed at various places of cable routeas per instruction of Eng. at site. | — | — | — | 19,75,635 | |
| — | 50.00 | — | — | ||
| Supply of Steel stool, 1 ft by 1 ft size, 1.5 ft height, laminated top. Inspection : Consignee | — | — | — | 53,178.5 | |
| — | 28.00 | — | — | ||
| Supply of lateral filing cabinet of size minimum 900 mm x 900 mm (3 ft x 3 ft) to store circuit diagrams, make Godrej/Durian/Methodex/ President or of similar reputed make. Inspection : Consignee | — | — | — | 4,17,630.92 | |
| — | 70.00 | — | — | ||
| Supply of self supported aluminium flatstep ladder (Confirming of ISI)10 ft.height. Make : Skyward/ Kalco/SJ Ladders/similar / superior. Inspection- Consignee | — | — | — | 4,76,774.9 | |
| — | 40800.00 | — | — | ||
| Loading, Leading & unloading of materials from store to another store as per instruction of consignee. All the material to be transported carefully without damage. Contractor have to do proper stacking of material and prepare list of material. | — | — | — | 2,13,792 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCACS1to6_compressed.pdf
ATTACHMENT
GCCACS7to12_compressed.pdf
ATTACHMENT
GCC_April-2022_1.pdf
ATTACHMENT
Tender doc
ATTACHMENT
TD-31-2026-27DefectiveSignallingCable_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].