Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹33.1 L+₹53,454.09 (1.64%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹35.0 L+₹2.5 L (7.62%)Rejected-Finance SUSHAMAPALLY PO NIMPURA KHARAGPUR DIST PASCHIM MEDINIPUR PIN 721304 W B | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹35.4 L+₹2.9 L (8.84%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹35.9 L+₹3.4 L (10.4%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹39.9 L
EMD Value
₹79,800
Closing Date
8 Jan 2024, 6:00 pmClosed
MAJOR M K YADAV, GE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REPAIR / MAINTENANCE OF MES INSTALLATION INCL MISC REPAIR WORK IN DSC POST AND DG SET ROOM AND REWIRING AND REPLACEMENT OF ELECTRICAL FITTINGS IN DOMESTIC AND TECHNICAL AREA AT AF STN KALAIKUNDA
2023_MES_630557_2
C/8916/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹79,800
Yes
29 Feb 2024
18 Dec 2023
9 Jan 2024
18 Dec 2023
8 Jan 2024
23 Dec 2023
Amount
Dismantling post of struts (Wood/Steel/RCC) any section,including taking out embedded portion in concrete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil.
Taking down and refixing the aluminium/copper earthing strips in same position with and including all new fittings and fixtures complete all as specified and as directed.
Taking up or down, steel tubing 15 mm bore, and connection including cleaning for re-fixing or removal from site of work complete all as directed.
Taking up or down, steel tubing 20 mm bore, and connection including cleaning for re-fixing or removal from site of work complete all as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including translucent sheet complete all as specified and as directed by Engineer-in-charge
Demolition cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. Note: All debris obtained from demolition shall be removed 1.5km to 2km complete all as specified and as directed.
Demolition cement concrete ( reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. Note: All debris obtained from demolition shall be removed 1.5km to 2km complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
Taking down shutters of any description exc 1 sq. m and not exc 2 sq. m each .complete all as specified and directed.
Plain cement concrete type B2 (1:3:6 )using 40 mm graded crushed stone aggregate) as in foundations fillings and mass concrete or embeding in fencing post complete all as specified and as directed.
Dismantling barbed wire, any type and in any position & separating them the serviceable & unserviceable materials and removing the unserviceable wire /barbed wire from work site as directed
Dismantling fencing wire mesh, any type and in any position & separating them the serviceable & unserviceable materials and removing the unserviceable wire mesh from work site as directed
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) disposing the rubbish to the out side of MD land complete all as specified
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as directed.
S & F galvanized steel barbed wire with two strands of line wire of dia 2.24 mm and barbed with point wire of dia 2 mm at 75 mm spacing straining and fixing to any type of standards, rails, straining bolts including securing or tying at crossings with and provision of galvanised iron binding wire, GI staples or steel pins, etc. complete all as specified and as directed (two strand of line wire will be measured as one unit).
S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed.
Supply and fixing galvanized steel chain link fence fabric of any mesh size , and dia of mesh wire as approved conforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). Make Tata or equivalent make as approved by GE
S&F flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal /square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long dia of shank 11 to 15 mm complete all as specified and as directed.
M & L for TMT Bars 10 mm dia and over cut to length,bent to shape required,including cranking,bending for securing chain link fencing complete all as specified and directed.
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed
S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed.
S&F Roof trusses (framed) trussed, purline crane gantries ,rails and fastenings and heavy brackeet framing (Beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde-E-250)quality-A complete all as specified and as directed.
Supply & Fixing for rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachment conforming to Fe:410-W(Gde-E-250 ) quality-A complete all as specified and directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
Preparation of newly or previously untreated steel surface of any description not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps complete all as specified and directed. (i) Complete removal of the existing water proofing treatment including padding (buid in cm/concrete) and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area) (iiii) Supply and Laying, chicken wire mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal construction including all laps, cutting and waste in fabric reinforcement to PCC roof padding including providing 40 mm thick plain cement concrete (1:2:4) type B0using 12.5 mm graded aggregates as in roof padding. (iv) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (v) Waterproofing treatment over smooth finished surfaces after application of bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384 (primer and membrane to be used shall be same manufacturer) prime shall be brand of Shalitex of STP or EmufalTE of M/s Texa Indian Ltd or cold stick bitumen primer of M/s IWL or equivalent make ,(vi) providing and laying APP polymer, modified, non-woven polyester fabric of 150 grams/square metre, reinforced membrane, 3.00 mm thick, weighing 3.60 Kg / Sq M, by torch on application method, with minimum 75 mm overlap on longitudinal direction and 100 mm overlap on the transverse direction and (vii)finally applying with one coat of bituminous based solar reflective aluminium paint @ 125 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed. Make of APP Membrane : M/s STP Ltd./M/s Texsa India Ltd./M/s IWL India Ltd 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be submitted. Requisite 10 years guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps up to 10 mtr height including necessary scalfolding and safety measures complete all as specified and as directed. (i) Complete removal of the existing water proofing treatment and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc and Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (iii) Applying bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384.(primer and membrane to be used shall be same manufacturer) prime shall be brand of Shalitex of STP or EmufalTE of M/s Texa Indian Ltd or cold stick bitumen primer of M/s IWL or equivalent make (iv) One layer of APP based polymeric membranes of approved manufacturers, 3 mm thick, weight not less than 3.6 kg/sqm, reinforced with non woven polyester fabric (weight not less than 160 gms/sqm). Polymeric membrane shall be taken to cover the thickness of slab and shall be finished by a membrane flushing. Note: (v) Laying of APP based membranes shall be done by torch application or as per manufacturer's instructions.(vi) Side overlaps shall be minimum 75 mm and the end taps shall be minimum 100 mm and sealing of all overlaps & joints as per manufacturer instruction. (vii) For parapets, membranes shall be taken to a height of minimum 60 Cm and then inserted to the parapet in a groove. The same shall be finished by a membrane flashing.(viii)finally applying with one coat of bituminous based solar reflective aluminium paint @ 125 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be sumitted. Requisite 10 years guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L brick work with fly ash bricks straight or curved on plan exec 6 M mean radius with old size bricks in CM (1:4) complete all as specified and as directed.
M & L for brick work with fly ash brick class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
M&L for rendering 5mm thick cement plaster CM 1:3 on chajja /soffits with integral water proofing compound on brick work or concrete surfaces finished even and smooth (without using extra cement) complete ll as specified and directed.
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, including all necessary scaffoldingand safety measures complete all as specified and directed Note: - (Water proofing compound will be deemed to be included in quoated rates
Material and Labour preparartion of new plastered surfaces of ceiling/chajja/soffits by means mechnical process / Machine as directed by manfucaturer through authorised applicator of manufacturer,s and applying two coat of100 % Acrylic Exterior Emulsion paint in camouflage pattern (Three colours as approved ) (Berger,Weather coat Advanced XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand painting over and including a coat of primer to new plastered or unplastered surfaces on walls including preparation of surfaces, complete all as specified and directed.
M&L for complete removal of existing treatment from walls, and applying two coats acrylic distemper on walls,over and including 1 mm thick white wall care putty premium quality over and including a coat of primer to old plastered or unplastered surfaces on walls plastered or unplastered surfaces on walls complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M & L for applying Two 100 % Acrylic Exterior Emulsion paint colours as approved by GE) (Berger,Weather coat Advanced XP long lifeBrand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand over a coat of exterior wall primer on new concrete/wall surfaces at any height including all necessary scaffolding complete all as specified and directed. (Work shall be exectuted through authorised applicator and shall be get approved by GE before commencement of work)
M&L for preparation of new plastered or un -plastered from walls, and applying two coats acrylic distemper on walls, over and including a coat of 1 mm thick white wall care putty and a coat of primer as per manufactrer,s instruction complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M & L for preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying Two coat of white washing on the wall all as specified and directed
Material and Labour for complete removal of existing treatment by means mechnical process / Machine as directed by manfucaturer through authorised applicator of manufacturer,s and applying two coat of100 % Acrylic Exterior Emulsion paint in camouflage pattern (Three colours as approved ) (Berger,Weather coat Advanced long XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand painting over and including a coat of primer to old plastered or unplastered surfaces on walls including preparation of surfaces, at any height including all necessary scaffolding and safety mesures complete all as specified and directed Note
Material and Labour for complete removal of existing treatment by means mechnical process / Machine as directed by manfucaturer through authorised applicator of manufacturer,s and applying two coat of100 % Acrylic Exterior Emulsion paint (Berger,Weather coat Advanced long XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand painting over and including a coat of primer to old plastered or unplastered surfaces on walls including preparation of surfaces, at any height including all necessary scaffolding and safety measures complete all as specified and directed
M&L 75 mm thick Cement concrete type B2 1:2:4 (using 40 mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and as directed.
Material & Labour for 100 mm thick Plain cement concrete ( 1:2:4 ), type B-1 (using 20 mm graded stone aggregate), as in flooring/ hard standing finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed
Supplying & fixing to walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls and ceiling 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S&F in repair Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed.
Supply and Fix,3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sq M in each pane with and including hacking out old broken glass (any thickness, size, quality or description) from frame including providing wooden beads painted with two coat of enamel paint over a coat of primer complete all as specified and directed.
Supply and Fix,4.8 mm thick tinted glass, superior quality and glazing with oil putty in squares not exceeding 0.50 Sq M in each pane with and including hacking out old broken glass (any thickness, size, quality or description) from aluminium frame work complete all as specified and directed.
S & F rotational moulded polyethylene multi layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes with and including 20mm Brass ball valves high pressure with polythene float and nut with and including dismantling exsiting unservieable tank one complete all as specified and directed .all as specified and as directed.
S & F rotational moulded polyethylene multi layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes with and including 25mm Brass ball valves high pressure with polythene float and nut with and including dismantling exsiting unservieable tank one complete all as specified and directed .all as specified and as directed.
Supply and Fix, solid PVC door frame of size 50 mm X 47 mm made out of 5 mm Prelam PVC sheet reinforced with MS square tube, fixed in opening all as specified and directed.
Supply and Fix, factory made solid panel Prelam PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded prelam PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail: Panelling of both sides pelam PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, fixed to door frame complete all as specified and directed.
Dismantling/taking down u/s parts of steel rolling shutters (self coiling types shutters i.e push pull with gear oprating type machnically or moter operated ) area n.exc 20.00 Sqm and for repairing and overhauling of rolling shutters and greading/oiling of members of rolling shutters. M&L for preparation of old painted iron and steel surfaces by scraping & rubbing down with sand paper, removing dense and scratches, if any and filling the same with paste filler and applying one coat of synthetic enamel paint complete all as specified. Note : (I) Refixing/welding of rolling shutters duly repaired/overhauled/welded/painted shall be included in the quoted rates of this item. (ii) Fixing of new parts of rolling shutters shall be included in the quoted rate of this item. (iii) Replacing of new parts of rolling shutters shall be paid and measured separately as supplying only under the relevent items. (iv) Makes/Size/Specifications of new parts of rolling shutters as per existing specificarion of rolling shutters. (v) Any damage or loss of rolling shutter during taking down/dismantling shall be made good by the contractor at his own cost.
Supply only safety lever locks and gear mild steel with 4 Levers for rolling shutters complete as per existing existing make
Supply only MS sheet 1.25mm thick for hood cover complete all as specified
Supply only curtain i.e interlocking lath sections formed from cold rolled steel strip 0.9mm thick complete all as specified
Supply only helical wire spring or flat spiral springs complete all as specified
Supply only ball bearing (ISI marked) size & make as per existing old type complete all as specified
Supply only MS 40mm bore pipes "heavy weight" for suspension shaft complete all as specified.
S&F in repair switch piano flush type single pole,5 Amp. AC, 230 V one way complete all as specified and directed by EIC.
S&F switch piano flush type single pole one way 5 Amps complete all as specified and directed (Note : Item to be measured if executed under new point wiring)
S&F in repair Polycarbonate Switch socket combination 5 Amps ,2 in 1, flush type complete all as specified and directed by EIC.
S&F Polycarbonate Switch socket combination 5 Amps ,2 in 1, flush type complete all as specified and directed by EIC.(Note : Item to be measured if execuated under new point wiring) .
S&F in repair Switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed.
S&F Switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose .complete all as specified and directed by EIC(Note : Item to be measured if executed under new point wiring)
S&F in repair ceiling Rose, surface,bakelite 65mm polycarbonate three terminals, AC, 230 Volts complete all as specified and directed by EIC.
S&F ceiling Rose, surface,bakelite 65mm polycarbonate three terminals, AC, 230 Volts complete all as specified and directed by EIC.(Note : Item to be measured if execuated under new point wiring)
S&F in repair bell push flush type single pole one way, 5 Amp, AC,230 V complete all as specified and directed by EIC.
S&F bell push flush type single pole one way, 5 Amp, AC,230V complete all as specified and directed by EIC.(Note : Item to be measured if execuated under new point wiring)
S&F in repair Bell, Ding dong type electric AC, 230V, Single phase,complete all as directed by EIC.
S&F bell ding dong type,AC, 230 volts, single pole on PVC box complete all as specified and directed by EIC. (Note : Item to be measured if executed under new point wiring)
S&F in repairs LED Bulb 12 watt with B22 base built in Rechargeable battery,cool day white, 1100 lumen 6500 K, surge protection upto 4 KV ,4 hrs battery backup ,AC 230V
S&F in repairs LED smart Bulb 9 watt with B22 base and wi-fi connectivity, colour changing , 806 lumen 6500 K,AC 230V ,complete all as specified and directed by EIC.
M&L in repair lamp holder , PVC/Poly carbonate type with back plate suitable for LED lamp fittings .including complete all as specified and directed
S&F LED 20 Watt tube light fitting intregated type, including, LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. (Note - Item to be measured if executed under new point wiring)
Taking down old unserviceable TPN / SPN MCB DB's incl MCB of any size and any discription complete all as specified and directed .
S & F sheet metal enclosure for MCB, DB, VTPN 415 Volts,IP-43, 100 amps rated copper busbar 4 way Double door ( Vertical DB with prov of MCB as incomer) Confirming to IS as per IEC 61439-3 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure for VT DB TPN, MCB DB TPN 4 way (with provision for MCCB as INCOMER and MCB as out going), Confirming to IS as per IEC 61439-3, IP 43,double door including 63 Amp, 25 kA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-Charge.
S&Fin repair sheet metal enclosure for VT DB TPN, MCB DB TPN 6way (with provision for MCCB as INCOMER and MCB as out going), Confirming to IS as per IEC 61439-3, IP 43,double door including 160Amp, 25 kA,250Amp rated busbar,TP MCCB as incomer (Vertical type double door, 160Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. (Note : DB and MCCB/MCB shall be of same make.)
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-Charge. (Note : DB and MCCB/MCB shall be of same make.)
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed.
S & F circuit breakers (MCB), three pole with one protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated Rated current 40 to 100 A,, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. (Note : DB and MCCB/MCB shall be of same make.)
S & F circuit breakers (MCB), three pole (TP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 25A to 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. Note: DB and MCCB/MCB shall be of same make.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. Note: DB and MCCB/MCB shall be of same make.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated Rated current 6A to 32 A,, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. Note: DB and MCCB/MCB shall be of same make.
S&F in repair of stepped type electronic fan regulator 100 watt flush type (mini) on the existing hylem laminated sheet etc as required complete all as specified and directed by EIC.
S&F stepped type electronic fan regulator 100 watt flush type (mini) on the existing hylem laminated sheet etc as required including taking down old u/s complete all as specified and directed by EIC.(Note : Item to be measured if executed under new point wiring)
S&F LED 2X18 Watt tube light fitting (T8 type) ,single/double side connection type including two nos LED retrofit tube lamp 2X18 W , LED tube light nominal power 18 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 housing with aluminium, life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.
S&F LED 22 Watt tube light fitting intregated type,colour changing, LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed.
S&F LED 20 Watt tube light fitting intregated type, colour changing, LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed.
S&F LED 9/10 Watt tube light fitting intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed.
S&F in repair LED 9/10 Watt tube light fitting intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ATHD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 housing with aluminium, life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. (NOTE - Item to be measured if executed under new point wiring)
S & F in repair LED bulkhead light with pressure die-cast housing light fittings nominal power 10/12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen efficiency of minimum 120 lumen per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 housing with aluminium, life span of minimum 50000 working hours complete all as specified and as directed.
S & F LED bulkhead light with pressure die-cast housing light fittings nominal power 10/12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen efficiency of minimum 120 lumen per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 housing with aluminium, life span of minimum 50000 working hours complete all as specified and as directed.. (Note : Item to be measured if execuated under new point wiring)
S & F LED flood lights nominal power 120 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110/120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours Make mentioned under particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 10 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge. Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services.
S & F in Repair LED wall mounted light Decorative type batten IP 20 with opal glass diffuser,B22 base type ,including 9 w LED bulb complete all as specified and directed by EIC.
S & F LED wall mounted light Decorative type batten IP 20 with opal glass diffuser,B22 base type ,including 9 W LED bulb complete all as specified and directed by EIC.(Note : Item to be measured if executed under new point wiring)
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor FRLSH cable as per IS 694: 2010 (with colour code), drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed.
M&L for concealed Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including PVC conduit pipe not less than 25 mm ISI marked including all accessories of conduit pipe as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continous earth conductor cable connected to earth dolly complete all as specified and directed by EIC.Note : Submain Wiring to be done as per approved colour code in IE rule.Rate includes chase cutting for concealed submain wiring.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable as per IS 694: 2010 drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continous earth conductor cable connected to earth dolly complete all as specified and directed. .
S&F for Sub main wiring with Four run of single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in with and including PVC casing capping not less than 32 mm ISI marked including all accessories of casing caping including one run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed by EIC. ( 4 x 6.0 sqmm + 1 x 6.0 Sqmm earth wire).
S&F in repair PVC casing caping of min 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping including taking down old u/s all as specified and directed by Engineer in charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants,regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.complete all as specified and directed by EIC.
S&F point wiring with 1.5 Sqmm FRLSH multi stranded copper conductor 1100 V grade,as per IS 694: 2010 , ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable duly painted with aluminium paint inside and anticorrosive paint out side with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets for the following:- Note :- (i) Contractor has to make the surface good after flushing the sunken box as per existing specification without any extra cost
One light/fan point controlled by one switch.
One bell/ buzzer point controlled by one push button on the same board with other switches or independent switches.
One 3 pin socket outlet, 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on independent board.
All as per item 113.00 here in before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed by EIC.
All as per item 113.00 here in before but power point wiring with 4.0 Sqmm FRLSH multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable & including PVC casing caping of 25 mm wide , including all accessories casing caping complete with PVC 4.0 sqmm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, for industrial metal clad socket power point.complete all as specified and directed by EIC.
S&F for concealed point wiring for one light/fan point with 1.5 sqmm (nominal area), FRLSH PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories including one run of 1.5 sqmm FRLSH muti stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box GI/MS/ pressed steel terminal box to be conclead in wall, duly painted with two coated of aluminium paint on internal and external surface , including laminated backlite sheet cover min 2.8mm thickness, ISI marked with CML No. for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer including making good as per existing complete all as specified and directed by EIC. Note : (i) Wiring to be done as per approved colour code in IE rule.Rate includes chase cutting for concealed wiring.
All as per item No. 120.00 here-in-before but for 3 pin 5 Amp switch socket combination on the same board with other switches.
All as per item No. 120.00 here-in-before, but for 3 pin 5 amp switch socket combination on independent board with other switches.
All as per item No. 120.00 here-in-before, but for bell/ buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 Sqmm.
All as per item No.120.00 here-in-before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
All as per item No.120.00 here -in- before but wiring with 4.0 Sq mm FRLSH mutistranded copper conductor cable for Industrial metal clad socket with 4.0 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete but excluding sunken box and backelite sheet cover all as specified and directed. .
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old u/s complete all as specified and directed by EIC.
S&F in repairs laminated bakelite sheet cover 2.8 mm thick, ISI marked with CM/L no.cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in loc with new galvanised screw and cup washer complete all as specified and directed by EIC,including taking down old u/s of following sizes.
11 x 13 inches
9 x 11 inches
5 x 8 inches
5 x 5 inches
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed .
S&F in repair modular switch 1 way 6A, 1 Module complete all as specified and directed
S&F in repair modular switch 1 way 16A, 1 Module complete all as specified and directed
S&F in repair modular bell switch 1 way , 1 Module complete all as specified and directed
S&F in repair modular socket 6A/16A 2/3 Pin combined -2 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings complete all as specified and directed by EIC
S&F in repair modular switch socket combination 16A , 6 Pin combined -3 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings complete all as specified and directed by EIC
Supply and fixing in repair of stepped type Modular electronic fan regulator 1- module , 100 watt flush type , on the existing hylam laminated sheet etc as required.complete all as specified and directed by EIC . including taking down old u/s Make: Anchor (Roma) cat No :- 289510 or equivalent of make : Legrand/ Havells (Crabtree)
S&F in repair Modular metal flush box of 1/2 module including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular metal flush box of 3 module including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular metal flush box of 4 module including taking out u/s including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular metal flush box of 6 module including taking out u/s including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 1 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 2 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 3 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 4 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 6 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 8 Module complete all as specified and directed by EIC.
S&F in repairs wall mounted bed side study lamp aluminium body, 3 W LED type warm white including LED driver with on /off button switch ,flexible pipe with lamp head 360 degree rotating type, 220 Volts, including taking down old u/s. Make : Philips cat No:-48042 or equivalent of make: Jaquar complete all as specified and directed by Engr- in- charge.
S & F LED downlight recess round shape nominal power 8/9 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die cast aluminium housing and ring, life span of minimum 50000 working hours complete all as specified and as directed.Make : :Wipro/Philips/Bajaj/GE
S&F in repair LED 18 watt round recess mounted LED edge lit slim downlightwith die cast aluminium housing,Efficacy > 100 lm/w including taking out old u/s complete all as specified and directed by EIC.
S&F in repair LED 18 watt round surface mounted LED edge lit slim downlight with PDC aluminium housing,Efficacy > 100 lm/w including taking out old u/s complete all as specified and directed by EIC.
S & F in repair LED street lights nominal power 25 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
M&L earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to GI wire of size 4 mm as earth lead by brass nut bolts washer and GI plate as shown in electrical plate No 3 connected to earth test point including necessary excavation in hard dense soil / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from out side defence land and construction of inspection pit of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :2: 4 , 12.5 mm aggregate A1 with MS sheet 3 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point,15 mm dia GI protection pipe light grade and 20 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of GI .including taking down old unserviceable earthing plate .complete all as specified and directed by Engr-in-charge (GI wire upto 7.5 RM will be included in the item rate and GI wire beyond 7.5 RM will be measured seperately (Note : (i) Contractor shall use Fresh agriculture soil for refilling the pit to achive the desired resistance. (ii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x GI nuts bolts and bringing argiculture soil from out side defence land deemed to be included in the item rate. (iii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.
S&F galvanised steel tubing light grade 15 mm dia for protection of GI wire fixed/ laid on floor/wall fixed with including G I clamps.including taking down old u/s complete all as specified and directed by Engr -in- charge
S&F for earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on batton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washer i complete all as specified and directed by Engr- In- charge
S&F decorative wall mounted light batten with B22D base , 240 Volt, PF > 0.90, colour Temp 6500 K, complete all as specified & directed by EIC.
S&F in repair LED bulb 12 watt with B22 base, lumen out put 1220 lumen per watt,6500 K complete all as specified and directed by EIC..
S& F in repair Rigid non-metallic PVC conduit pipe dia 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock,nuts, saddles, pipe hooks etc complete all as specified and directed by EIC.
SHARMA ENTERPRISES
M/S ELECTROVISION
M/S C C CONSTRUCTION
SUMAN CONSTRUCTION
M/s Antara
NATIONAL CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .