Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER CIVIL
1st floor old cto, telephone house rajbhavan road Bangalore 01
Replacement of damaged sanitary line along with additional man holes from T1 block to T2 block at WMS compound Jayanagara Bengaluru 560041
2022_BSNL_102208_1
35/EEC/BSNL/CD/BGL/2021-22
Open Tender
Civil Works - Buildings
Item Rate
30 days
BANGALORE
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts officer (CASH) HQ BSNL BGTD Bengaluru
₹4,700
29 Jan 2022
18 Jan 2022
29 Jan 2022
19 Jan 2022
25 Jan 2022
19 Jan 2022
19 Jan 2022 - 24 Jan 2022
30 days
Amount
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:
100 mm diameter S.W. pipe
150 mm diameter S.W. pipe
Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps:
100 mm diameter
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 100 to 250 mm diameter
Cutting tree roots hindering in laying/replacing damaged sanitary lines including disposal up to a lead of 200 mtr. Etc, complete as per directions of Engineer-in-Charge
Providing and Fixing PVC SWR grade pipes of approved brand and manufacture (FOR MAINTENANCE WORKS) including fixing it in position using solvent or cement mortar ,all complete as directed by Engineer-in-Charge
(a)110mm dia
Providing and fixing PVC SWR grade pipes of approved brand and manufacture (FOR MAINTENANCE WORKS) including fixing it in position using solvent or cement mortar ,all complete as directed by Engineer-in-Charge
160MM DIA (Outer dia)
Providing and fixing SWR grade fittings of approved make and manufacture
100mm dia bend
Extra charges for laying concree and SWR pipe under fould condition etc complete as directed by the Engineer in charge.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .