Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.6 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹25.9 L+₹90,119.27 (3.61%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹27.7 L+₹2.7 L (10.7%)Rejected-Finance FLAT NO 104 SARITA ELEGANCE SINHAGAD ROAD PUNE DIST PUNE | PUNE | MAHARASHTRA | 410301 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹29.7 L+₹4.7 L (18.7%)Rejected-Finance | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹29.7 L+₹4.7 L (18.9%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L-5 | Rejected-Finance L-5 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
4 Sept 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR TO DRAIN, PATH, CULVERT, FENCING, SEWAGE LINE, MANHOLE, SEPTIC TANK, SOAKAGE WELL AND REPAIR TO EARTHING PITS, LIGHTENING ARRESTORS, FLAME PROOF FITTING, SUMMER APPLIANCES, HOT WATER APPLIANCES AND OTHER MISC WORKS AT AF STN NARAINA
2024_MES_664640_1
GE (FBD)/AF-28/2024-2025
Open Tender
Civil Works
Item Rate
180 days
Naraina
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹98,000
Yes
10 Dec 2024
8 Jul 2024
6 Sept 2024
8 Jul 2024
4 Sept 2024
22 Jul 2024
8 Jul 2024 - 13 Jul 2024
Amount
Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 02 above but except bricks.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L, Rendering in foul position (Shaft Area),15mm thick in CM 1:4 on of brick work or concrete surface upto G+3 story of building finish even and smooth (w/o using extra cement) incl WPC @3% by weight of cement complete all as specified and directed by Engineer-in-Charge. Note:- Site for application is at various locations in patches and height varies up to 12 Meter Proper stable Scaffolding is must for working for the safety of resident of bldg and worker. Cost of all types of formwork, scaffolding and welded mesh shall deemed to be included in quoted rate.
M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directed by Engineer-in-Charge.
M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone agg. ) as in plinth protection / path/ any paved area complete all as specified and directed by Engineer-in-Charge.
M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, M-35 grade with grey cement, pigment incl 25mm thick sand filling complete all as specified and directed by Engineer-in-Charge.
M&L for 60 mm thick machine cut precast concrete interlocking paver block except tile ,(M-35) grade any clours as approved by GE complete all as specified and directed by Engineer-in-Charge.
M&L for 80 mm thick machine cut precast concrete interlocking paver block with grey cement and pigment ,(M-40) grade any clours as approved by GE complete all as specified and directed by Engineer-in-Charge.
M&L for 80 mm thick machine cut precast concrete interlocking paver block except tile ,(M-40) grade any clours as approved by GE complete all as specified and directed by Engineer-in-Charge.
M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by GE with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed by Engineer-in-Charge.
M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor/sub base finishes ccomplete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises and incl demolition complete all as specified and directed by Engineer-in-Charge.
Cleaning /removal of blockage 150 mm bore SWG pipes of depth not exc 1.50 mtr with mechnical process incl removing RCC man hole covers and refixing the same as before complete all as specified and directed by Engineer-in-Charge.
Cleaning /removal of blockage 300 mm bore SWG pipes of depth exc 1.50 mtr but not exc 3.00 mtr with mechnical process incl removing RCC man hole covers of any size, and refixing the same as before complete all as specified and directed by Engineer-in-Charge.
Dewatering/desilting of existing manholes of any size depth and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system or using suction pump where ever required up to any depth )and incl removing RCC manhole Covers and refixing the same after making the manhole fully functional, complete all as specified and directed by Engineer-in-Charge.
Dewatering/desilting for the septic tank of any capacity exc1.50 m and n.exc 4.5 m deep solid/semi-solid matter of silt residue both organic or inorganic in nature ( mechanical system or using suction pump where ever required up to any depth by working under foul conditions and disposal of the same in out of MoD area, complete all as specified and directed by Engineer-in-Charge. Note for Item : The Septic tank shall be measured more than one time as per requirment
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft or loose soil for shafts, wells,drains, manholes etc n exc 10Sqm on plan for sewage line & foundation etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 22 above but exceeding 1.5 M depth and not exceeding 3 M for foundation, etc., and getting out in Soft/ Loose soil.
Demolition and breaking up drain pipes 100mm dia ( Salt Glazed ware, AC or reinforced concrete) set in cement mortar including PCC bed and haunching and removal of debris outside the MD land complete all as specified and directed by Engineer-in-Charge.
Demoltion and breaking up existing sewag(SWR/ AC pipes and the like, 150mm bore set in cement mortar and removing demolished material to a distance exc 50m and n exc 100m complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm PVC (SWR ) , pipes single socketd , in any length with rubber ring joints , laid in trenches or in floor complete all as specified and directed by Engineer-in-Charge.
S & F for salt glazed stoneware, 150 mm bore drain pipes laid and jointed complete with collars complete all as specified and directed by Engineer-in-Charge.
S & F for salt glazed stoneware, 150 mm bore drain pipes laid and jointed complete with collars complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100 mm bore complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and directed by Engineer-in-Charge.
S & F in repair for precast factry made reinforced cement concrete Manhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty (size of the cover will be itimated by the EIC) complete all as specified and directed by Engineer-in-Charge.
Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed by Engineer-in-Charge.
M&L for Plain cement concrete (1:2:4) Type B-1, (using 20mm graded crushed stone aggregate), as in copings, kneelers , apex stones,bed plates, including weathering ,slightly rounded /benching or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge. ( Rates include for use of formwork)
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 100mm dia pipe complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and foRMing branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and refoRMing benching as required, 150mm dia pipe complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in surface channels, drains and bed of manhole complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc complete incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm bore CI bends fitted with oval access doors (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore CI bends fitted with oval access doors (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm branch pieces/T section fitted with oval access doors, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches/ Tee etc complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm branch pieces/T secction fitted with oval access doors, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches/ Tee etc complete all as specified and directed by Engineer-in-Charge.
S& F for 75 Cast Iron Cowl complete all as specified and directed by Engineer-in-Charge.
S& F for 100 Cast Iron Cowl complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm dia cast iron socket (double collars) including jointing to pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 100 mm dia cast iron socket (double collars) including jointing to pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC bends/junction with access door any radius complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm dia PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC bends/junction any radius complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs ( for manholes etc.), shelves and similar articles with plain faces including necessary form work, set in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. Note: Reinforcement shall be measured and paid for separately under respective item.
S&F TMT MS bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge.
Removing daberies/excavated material to a distance exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Note :- Contractor shall be bounded to carryout repair / maint upto G+3 storey building and the rate shall be deemed including scafolding / double scafolding, safety equipments and misc accessories.
Taking down storage water heater 25 ltrs capacity from wall for repair/replacement of unserviceable parts and refixing with fasterners Nuts and washers the same after repair work complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of thermostate 0-60 degree as per sample in water geyser 25/50 litre capacity ISI Make as per sample complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of heating element 1.5KW,Triangular/round type as per sample complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of heating element 2 KW with complete assembly of any model and type as per site requirement /sample complete all as specified and directed by Engineer-in-Charge.
Material and Labour for disconnecting from electric and water mains and dismantling the unserviceable gyeser base assembly and replacing the new base assembly 6/9 holes with rubber gasket for 25 Ltrs capacity of any make and refixing in original place including recoonecting of electric and water supply mains including testing complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of geyser outer body cover of 25 Ltr capacity made out of 16 SWG powder coated complete with all connected accessories suitably fitted with existing wall complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of geyser tank stainless steel suitable for 25 Ltr capacity geyser complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of PVC connection with brass inserts suitable for hot/cold water, 60 cm long (for hot and cold water inlet and outlet) having PTMT nuts with washer complete all as specified and directed by Engineer-in-Charge.
S & F in Replacement of bottom cover suitable cylindrical type geyser as per existing required as per site for 25 Ltrs capacity complete all as specified and directed by Engineer-in-Charge.
Dismantling and opening storage tank of geyser 25 litre capacity to identify the leakage ,repair the spot by suitable welding carefully including making good insulating material, assembling and testing complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of indication lamp red and green (pilit type ISI marked) for 25 Ltrs water heater complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of PVC insulated flexible copper conductor cable 40/0.0076 size 3 core suitable for 650 volts grade complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of glass wool in any capacity of geyser complete all as specified and directed by Engineer-in-Charge.
M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 1.5 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 1.5 Sqmm size and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge. (Flexible Copper Wire Used In FRLS)
M&L submain wiring copper conductor multi stranded 4 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous alongwith earth wire 2 Sqmm size and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge. (Flexible Copper Wire Used In FRLS) Note: Two run of cable shall be measure as single run.
M&L submain wiring copper conductor multi stranded 6 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous alongwith earth wire 4 Sqmm size and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge. (Flexible Copper Wire Used In FRLS) Note: Two run of cable shall be measure as single run.
S&F Piano switch in repairs, flush button,single pole,one way 5/6 Amp complete all as specified and directed by Engineer-in-Charge.
S&F piano switch,in repairs, flush button single pole one way 15/16 Amp complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, in repairs,flush type 2 in 1, 2 pin and 3 pin 5 Amp complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, in repairs,flush type 2 in 1, 3 pin and 6/16 Amp complete all as specified and directed by Engineer-in-Charge.
S&F stepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amp complete all as specified and directed by Engineer-in-Charge.
Supply and fixing amp rating 240V, SP 5 To 32 AMP 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Supply and fixing amp rating 240V, SPN 40 To 63 AMP 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan complete any type size from existing location and cleaning body blades etc including servicing, greasing,oiling, replacing wornout bearing ,bush and refixing the same at site complete all as specified and directed by Engineer-in-Charge.
All as per item No 82 above but for Exhaust fan 300 mm sweep
All as per item No 82 above but for Exhaust fan 450 mm sweep
All as per item No 82 above but for wall/floor mounted fan 450 mm sweep
S&F wall mounting fan motor for 450 mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories 230V, 1200/1400mm sweep with squirrel cage induction motor complete all as specified and directed by Engineer-in-Charge.
Supply & Fix blades suitable for 1200/1400 mm sweep ceiling fan set of 3 blades complete all as specified and directed by Engineer-in-Charge.
S & F Recess mounted LED Light Fitting 15 Watt pressure die-cast aluminium luminaire in powder coated white finish in round/square profile with optimized heat sink for efficient heat dissipation and incl separate replaceable electronic driver compatible for Analog/DALI Dimming complete all as specified and directed by Engineer-in-Charge.
Rewinding unserviceable ceiling fan 1200/1400 mm Sweep from site and depositing E/M sub division by strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original guage of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan complete all as specified and directed by Engineer-in-Charge.
All as per item No 90 above but for Exhaust fan 300 mm sweep
All as per item No 90 above but for Exhaust fan 450 mm sweep
All as per item No 90 above but for wall/floor mounted fan 450 mm sweep
S&F in repairs Capacitor 2.5 mfd suitable for Ceiling Fan/Wall fan/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Capacitor 3.15 mfd suitable for Ceiling Fan/Wall fan/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
Supply and Fix FR PVC electrical insulation tape,1.8 cm x 25 mtr x0.125 mm thick complete all as specified and directed by Engineer-in-Charge.
Supply and fix Ventilation fan PVC (250 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge.
Supply and fix Ventilation fan PVC (200 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge.
Supply and Fix aluminium thimbles of size 35 sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and Fix aluminium thimbles of size 50 sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and Fix aluminium thimbles of size 70 sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and laying PVC insulated sheathed aluminum conductor cable 16 sqmm two single core 1100 volts grade multistanded conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connections complete all as specified and directed by Engineer-in-Charge.
Taking up or down following sizes steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
All as per item No 103 above but 40mm bore
All as per item No 103 above but 25mm bore
All as per item No 103 above but 20 mm bore
All as per item No 103 above but 15 mm bore
Supply, laying and fixing GI water tubing medium grade with all fittings and fixed complete to all walls,ceiling,laid in floors,roof etc with following sizes complete all as specified and directed by Engineer-in-Charge.
All as per item No 108 above 40mm bore
All as per item No 108 above 25mm bore
All as per item No 108 above 20 mm bore
All as per item No 108 above 15 mm bore
M&L 32 mm GI pipe light grade of 1.3 mtr piece fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed by Engineer-in-Charge.
Replacement of old unserviceable and providing new safety valve(ISI Marked) suitable for 25 to 50 Ltrs capacity geysers complete all as specified and directed by Engineer-in-Charge.
M & L for Replacement of old unserviceable and providing new non return valve made out of brass (ISI marked) for bore dia of pipe 15mm size complete all as specified and directed by Engineer-in-Charge.
M & L for preparing the old painted steel surface by rubbing/scratching the old paint of 25 ltrs capacity geyser and painting with two coats of synthetic enameled paint white with spray gun including writing MES Nos with black paint (of required size and shape) complete all as specified and directed by Engineer-in-Charge.
M & L for metal clad plug top 20 A 2 P+ E, 230 V AC as in repair complete all as specified and directed by Engineer-in-Charge.
M & L for metal clad socket 20 A 2 P+ E 230 V AC as in repair ccomplete all as specified and directed by Engineer-in-Charge.
Supply & fix anchor bolt of size 12mm x 100mm long with washer including drilling holes for fixing anchor bolt and making good to the disturbed surface matching with specification complete all as specified and directed by Engineer-in-Charge.
M & L for Descaling of gyser of capacity 25litre /50litre from wall after unscrewing nuts/bolts etc and again refixing in position after repair including strip opening the assembly,de-scalling the syphon assembly, steel tank and incoming and outgoing water connection complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 25x4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I of 2009 connected to and including earthing test point or disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe for watering and funnel, GI Pipe medium grade 40mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1 complete all as specified and directed by Engineer-in-Charge.
Material and Labour for making new hole of 150 mm dia and 3.0 mtr depth or excvation of earthing size 1.5x1.5x3.5 mtr one pit and supply and filling in micronite(bentonite) base earthing enhancement micronite compound (0.001 ohms mtr conductive grounding granuals 25 kg in each pit) and copper electorode rod 17.7 mm dia and 3 mtr long as per relavent IS and to achieving the desired earth result complete all as specified and directed by Engineer-in-Charge. (Each earth pit shall include minimum 25 kg NABL Lab certified micronite aggregate and cement 12.5 kg for filling bore hole with water mixed in 1:2 ratio (two parts of micronite aggregate compound and one part of cement), so also achieve eath resistance below 1 ohm including PVC pit box with cover shall be deemed to be inclusive in the quoted rates. In case of non achieving of desired results the same shall be re-done by the contractor on his own cost.
M & L in repairs earthing complete with galvanised steel earth plate electode 600 x 600 x 6.0 mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to & including galvanised steel wire 4.0 mm dia size means of nuts and bolt check nuts and washers of galvanised rion sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to earthing test point complete including testing filling of adquate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil upto 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made out of 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium strip 25 mm x 3 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed by Engineer-in-Charge.
Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long complete all as specified and directed by Engineer-in-Charge.
S&F porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed by Engineer-in-Charge.
Repairs to strip of any material and any size by removing from saddles/holders/wall/roof and strengening the strip and refixing complete all as specified and directed by Engineer-in-Charge.
M&L for Testing of exisiting earthing resistance with suitable digital Earth tester and recording the readings obtained and making the earthing good by pouring the salt water complete all as specified and directed by Engineer-in-Charge.
Supply and fix copper strip 20mm x 3 mm complete with insulators and fixing screws etc for roof/wall above ground level including removing u/s strips complete all as specified and directed by Engineer-in-Charge.
Repairs to earth chambers by demolishing unserviceable earth chambers and fixing new chambers of PCC 1:3:6 type C1 as per electrical plate no.3 of SSR part-I complete all as specified and directed by Engineer-in-Charge.
Repairs to earth chamber cover by removing unserviceable earth chambers cover and fixing new cover complete all as specified and directed by Engineer-in-Charge.
Supplying and laying synthetic rubber insulated mats 2.5mm thick for voltage upto 11kv for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of sizes 2mX1m complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing LED security light fittings 70 watt IP 65 having uniformaty ratio, 0.25 high pressure die cast aluminium housing heat resistant tough and glass with frame IP 66 protection complete with lamp and connected items and connection with suitable cable from ceiling rose to light fitting and fixing on GI pipe bracket made out of suitable dia including GI pipe medium grade 1.2 m long bend to shape and fixed on wall with flat iron clamps nut bolts was including PVC copper cable 1.5 square mm 3 core connecting box to streat light connection it is complete all as specified and directed by Engineer-in-Charge.
M&L for LT Pole box for security/Street light weather proof made out of PVC fire retardant non fusing sock and dust proof one piece molded SMC base and SMC cover with hinged door all mounting type comprising of aluminium 25Amp bus bar with MCB SP 10 amp of size 300x200x100mm, fixed on pole with MS clamps 20x3mm with necessary nuts, washers and incl applying two coats of synthetic enamel paint over red oxcide primer on steel surface/clamps and embrossing/painting of danger sign of size not less than 10cmsX7.5 cms with letter and conventional skill and bones in signal red colour on front face of kisko box complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,LED false ceiling panel fittings ,1x45W/1x40W LED 6000K (2ftx2ft.), 230 volts AC,suitable for false ceiling, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engineer-in-Charge.
Supply and install and commmissionng of LT bus bar chamber CPRI approved out door type with sloping canopy of size 600x600x600mm made out of 3.15 mm thick CRCA sheet, panel shall be powder coated siemens grey shade mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4:8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200 mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps,3 pole ,415 mps, 50 Hz of breaking capacity 25 KA as incomer complete all as specified and directed by Engineer-in-Charge
M&L for point wiring with single core FRLS PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through in PVC conduit suitable for flameproof switch/socket/LED Bulk Head ligh/Fluorescent LED fixed on wall, ceiling with GI saddles GI screws, rawal plugs (concealed conduit wiring) with all fittings including Tee, junction boxes and provision of modular metal flush box of suitable size modular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with stranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed.(a) One light point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
Supply and fix Fluorescent LED tube light fitting 1 x 16/20W flameproof type made of Die cast aluminium alloy housing with heat resistant glass/heat resistant dome glass/extrenal reflector with CMRI certified LED FLameproof well glass luminaire for gas/vapour grtoup of IIA & IIB ans Zone 1 & IP65 protection etc. complete with all accessories prewired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge.
Suppply and fix flame proof switch socket & plug combined in LM 6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed by Engineer-in-Charge.
SAGAR ENTERPRISES (BID ID -3083097)
M/S BHARAT BUILDERS (BID ID -3071374)
ETERNITY PROJECT (BID ID -3081078)
M/S Rohit Enterprises (BID ID -3083698)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .