| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being Lowest Bidder after deducting the sch of credit Rs. 109245.00 | |
| 2 | L2₹32.0 L+₹63,796.16 (2.03%)Rejected-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC 2nd Lowest Bidder after deducting the sch of credit Rs. 109245.00 | |
| 3 | L3₹32.2 L+₹83,290 (2.66%)Rejected-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC 3rd Lowest Bidder after deducting the sch of credit Rs. 109245.00 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Dhar Road Udhampur
GE Army Dhar Road Udhampur
REPAIR AND MAINTENANCE OF EXTERNAL LT ELECTRIC SUPPLY SYSTEM AND CONNECTED ITEMS AT DHAR ROAD UNDER GE ARMY DHAR ROAD
2021_MES_480788_2
8067/NIT-52/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Army Dhar Road Udhampur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road Udhampur
₹80,000
Yes
10 May 2022
23 Nov 2021
10 Dec 2021
23 Nov 2021
8 Dec 2021
24 Nov 2021
23 Nov 2021 - 24 Nov 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in soft/loose soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
All as per item No. 1 above but depth exceeding 1.5 mtr and not exceeding 3 mtr complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
M & L for dry Sand cushioning in trenches for cushioning of cable 8mm thick under the cable and 15cm over the cable for protection complete all as specified and directed. Note: Punned thickness 18 cm only shall be considerd for measurment purpose.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 100 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
S&F Sheet metal enclosure box 3.15 mm thick CRCA sheet with power coated paint (CPRI Approved) double door outdoor type including solid aluminium bus bar of capacity 400 amp 4 Nos strip with locking arrangements, enclosure box to be fixing on plinth foundation coping1:2:4 and 1:4:8 for plinth and 150 mm avobe ground level including MS angle/ chanel consisting of necessary fixing arrangements for incoming & out going cables with cable glands, lugs, nut, bolts, washers and fixing arrengement , PCC work including necessary flat iron clamps with nuts, bolts & washers and Powder coated all as specified and directed.
S&F Sheet metal enclosure box 3.15 mm thick CRCA sheet with power coated paint (CPRI Approved) double door outdoor type including solid aluminium bus bar of capacity 400 amp 4 Nos strip including MCCB 250 Amps 4 pole 25 KA with locking arrangements, enclosure box to be fixing on plinth foundation coping1:2:4 and 1:4:8 for plinth and 150 mm avobe ground level including MS angle/ chanel consisting of necessary fixing arrangements for incoming & out going cables with cable glands, lugs, nut, bolts, washers and fixing arrengement , PCC work including necessary flat iron clamps with nuts, bolts & washers and Powder coated all as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for heat shrink type end joint out door type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm complete all as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for heat shrink type end joint in door type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm complete all as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for heat shrink type straight joint out door type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm complete all as specifeed and directed.
Supply & laying in replacement of HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 95 Sqmm 3 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed
Supply and fixing route indicator pre-cast concrete with steel bar 10 mm dia reinforced for locate to HT cables of size 800mmx100mmx350mm and engraved /marked “ 11 KV HT ELECTRIC CABLE” and fixing with PCC foundation all as specified and directed
Dismentling taking out broken/worn out PCC pole any type of 9.0 to 11 mtr long all as specified and directed.
Supply, Errecting and fixing of true Vertical position steel tubular swaged pole complete with coat iron base plate, finial taper plug, bolt, nuts and screw,weld and reduced section and logitudional weld Seam through out entire length of pole including 2 coats of black bituminious paint through out intrnely and externely up to planting depth and remaining exterior portion of pole with two caot of aluminium paint over a coat of red oxide as specified type 410 SP 31 (9.00 Mtr long) all as specified and directed at site. NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately.
Supply, Errecting and fixing of true Vertical position steel tubular swaged pole complete with coat iron base plate, finial taper plug, bolt, nuts and screw,weld and reduced section and logitudional weld Seam through out entire length of pole including 2 coats of black bituminious paint through out intrnely and externely up to planting depth and remaining exterior portion of pole with two caot of aluminium paint over a coat of red oxide as specified type 410 SP 55 (11.00 Mtr long) all as specified and directed at site. NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately.
Dismentling and taking down old/unsv cross arms, bracing, supports etc complete all as specified and directed.
S&F cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
Dismentling and taking down old/unsv ACSR conductor any size complete all as specified and directed.
S&F, streching of ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection all as dercted. Note :- Size of aluminium conductor as per site requirement will be directed by Engineer-in-Charge. Make : Jaipuria, Aluminium IND, ICC, NICCO, ALIND
Dimentling and taking down old/unsv insulator of any type any size from pole/stay complete all as specified and directed.
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and directed. Make : Jaipuria / BHEL /PACTIL/ MASORE PORCEILIN
S&F shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps, washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed. Make : Jaipuria / BHEL /PACTIL/ MASORE PORCEILIN
S&F Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm all as specified and directed.Make : Jaipuria / BHEL /PACTIL/ MASORE PORCEILIN
S&F Disc type insulator porcelain, vitrous 145mm high and 255 mm dia ball and socket type white, brown or green single disc with tension clamp for conductor for working pressure voltage 11000 V including dismentling taking out unsv one from Pole. Make : Jaipuria / BHEL /PACTIL/ MASORE PORCEILIN
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 150mm height and 150 mm dia for 11000 volts grade all as specified and directed.Make : Jaipuria / BHEL /PACTIL/ MASORE PORCEILIN
M/L for Stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismentling unsv one all as specified and directed. (Clamps, loop insulator, earth work, PCC measured separately)
S/F for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismentling taking down unserviceable one all as specified and directed
M & L triple pole mechanically operated GOD mounted on insulators and steel frame with operating mechanism worked from ground level 11000 volts grade of current carying capacity up to 200 Amps complete incl removing the existing U/S one.
M&L for restraining of overhead ACSR conductor of any size of 5 conductor on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and directed
M&L for restraining of ACSR conductor of any size of 2 conductor on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and directed
S&F MCCB 630 Amps 4 Pole, 36 KA, 415 V, 50 Hz adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
All as per item No 48.00 here in before but MCCB 400 Amps 4 Pole, 35 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 48.00 here in before but MCCB 320 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 48.00 here in before but MCCB 250 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 48.00 here in before but MCCB 200 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 48.00 here in before but MCCB 160 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 48.00 here in before but MCCB 100 Amps 4 Pole, 16 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 48.00 here in before but MCCB 63 Amps 4 Pole, 16 KA, 415 V, 50 Hz complete all as specified and directed.
M&L for painting and write pole number of steel tubular pole 9 meter long with one coat of alumium paint incl cross arm, bracings, supports, nuts, bolts, of LT OH line from above copping to top of pole and marking with alternate white and yellow/black paint strip 30 cm wide (5 Nos of strip) with synthetic enamelled paint all as specified and directed.
M&L for painting and write pole number of steel tubular pole 11 meter long with one coat of alumium paint incl cross arm, bracings, supports, nuts, bolts, of LT OH line from above copping to top of pole and marking with alternate white and yellow/black paint strip 30 cm wide (5 Nos of strip) with synthetic enamelled paint all as specified and directed.
M&L for trimming of branches of trees touching LT/HT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 7 mtr and above and carrying and depositing where directed not exceeding 50 mtr.
S&F rigid PVC line spacer, suitable for 2 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade including taking down unsv one all as specified and directed.
S&F rigid PVC line spacer, suitable for 5 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade including taking down unsv one all as specified and directed.
Supply and fixing of breather assembly of Transformer incl silica gel upto 250 KVA transformer as per existing make and type complete all as specified and as directed.
Supply and fixing of breather assembly of Transformer incl silica gel 315 KVA to 500 transformer as per existing make and type complete all as specified and as directed.
Supply only brass terminal stud with nuts, check nut, oil seal and washer for LV side of transformer of any make (as per sample) up to 250 KVA transformer complete all as specified and as directed.
Supply only brass terminal stud with nuts, check nut, oil seal and washer for LV side of transformer of any make (as per sample) from 300 KVA to 500 KVA transformer complete all as specified and as directed.
Shifting of voltage stablizer 25 KVA at Dhar Road Garrison between 16CZW are to Ad Bde area by transportation in safe custody incl loading and unloading from foundation complete all as specified and directed Note :- Rate for hiring of cranes are deemed under this item
Shifting of voltage stablizer 100 KVA at Dhar Road Garrison between 16CZW are to Ad Bde area by transportation in safe custody incl loading and unloading from foundation complete all as specified and directed Note :- Rate for hiring of cranes are deemed under this item
Servicing, repairing, overhauling and testing of Voltage Stablizer of capacity 400 KVA by disconnecting the incoming and outgoing connection strip opening the stablizer complete for taking out the unserviceable servo motors, auto control, circuit plates, dimmer and switches, voltmeter with switches and replace the following and testing on full load as directed by the Engineer-in-Charge for the following Capacity :-(a) Servo motor as per existing size - 01 No, (b) Voltmeter 0 to 500 Volts with switch. - 01 No, (c) Voltage on off adjusting switch (Auto control Switch), (d) Supply and pouring transformmer oil after dehydrating the sump (e) Roller Wheels as per existing size - 04 Nos, (f) Voltmeter 0-300 Volts - 03 Nos (g) Supply and fixing of dimmer 400 KVA -03 Nos Note- Supply and flling transformer oil shall be paid under respective item, quantity of which shall be got ascertained through Board of officers.
Servicing, repairing, overhauling and testing of Voltage Stablizer of capacity 100 KVA by disconnecting the incoming and outgoing connection strip opening the stablizer complete for taking out the unserviceable servo motors, auto control, circuit plates, dimmer and switches, voltmeter with switches and replace the following and testing on full load as directed by the Engineer-in-Charge for the following Capacity :-(a) Servo motor as per existing size - 01 No, (b) Voltmeter 0 to 500 Volts with switch. - 01 No, (c) Voltage on off adjusting switch (Auto control Switch), (d) Roller Wheels as per existing size - 04 Nos, (e) Voltmeter 0-300 Volts - 03 Nos (f) Supply and fixing of dimmer 100 KVA -03 Nos Note- Supply and flling transformer oil if required shall be paid under respective item, quantity of which shall be got ascertained through Board of officers
Servicing, repairing, overhauling and testing of Voltage Stablizer of capacity 63/50 KVA by disconnecting the incoming and outgoing connection strip opening the stablizer complete for taking out the unserviceable servo motors, auto control, circuit plates, dimmer and switches, voltmeter with switches and replace the following and testing on full load as directed by the Engineer-in-Charge for the following Capacity :-(a) Servo motor as per existing size - 01 No, (b) Voltmeter 0 to 500 Volts with switch. - 01 No, (c) Voltage on off adjusting switch (Auto control Switch), (d) Roller Wheels as per existing size - 04 Nos, (e) Voltmeter 0-300 Volts - 03 Nos (f) Supply and fixing of dimmer 63/50 KVA -03 Nos Note- Supply and flling transformer oil if required shall be paid under respective item, quantity of which shall be got ascertained through Board of officers
Servicing, repairing, overhauling and testing of Voltage Stablizer of capacity 25 to 10 KVA by disconnecting the incoming and outgoing connection strip opening the stablizer complete for taking out the unserviceable servo motors, auto control, circuit plates, dimmer and switches, voltmeter with switches and replace the following and testing on full load as directed by the Engineer-in-Charge for the following Capacity :-(a) Servo motor as per existing size - 01 No, (b) Voltmeter 0 to 500 Volts with switch. - 01 No, (c) Voltage on off adjusting switch (Auto control Switch), (d) Roller Wheels as per existing size - 04 Nos, (e) Voltmeter 0-300 Volts - 03 Nos (f) Supply and fixing of dimmer 25 to 10 KVA -03 Nos Note- Supply and flling transformer oil if required shall be paid under respective item, quantity of which shall be got ascertained through Board of officers
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised iron earth strip 32x6mm upto test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including light grade GI watering pipe 20mm bore with funnel wire mesh and medium grade GI wire protection pipe 40mm bore up to main board completew as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete ass as specified and testing on completion complete ass as specified and directed by Engineer-in-charge. Note - The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (light grade) for watering 40mm GI protection pipe (medium grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
S&F Galvanised iron strip 32 x 6 mm for extension of earth and connected to equipment or panel complete all as specified and as directed .
Material and labour for painting to surfaces of any description, new or prevoiusly untreated surface,with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed
Supply and laying 63 mm nominal size Graded coarse aggregate and aggregate shall be measured net, in compact stacks,prepared on level ground all as specifed and directed
Replacement of auxiliary power supply/ battery bank with panel made of 2mm CRCA sheet complete with maintenance free lead acid battery bank mounted on MS rack and provide with connector etc complete in all respect with install capacity 24 Volts DC 12Nos each of 2 Volts 60AH complete all as specified and directed by Engr-in-Charge.
Replacement of booster charger for 12 volt/24 volt batteries, (60 AH 12 Nos ) for using of sub station auxilary supply all as per standard specification and including DCDB for charger complete with DC Amps Meter Volt meter, switches ON/OFF, TRICKEL/BOOSTER
Supply and fixing Emergency medical resuscitation kit comprising of antiseptic, antibiotic, adhesive bandages, dressing, first aid tapes, first aid scissors, gloves etc complete all as specified and directed Make -Medicare or equvts
Supply and errect fire stand with MS sheet cover of suitable size made out of MS / angle iron/ chanel duly painted with two coats of synthetic enamelled post office red colour over a coat of red oxide as primer and lettering with white paint including providing the following all as directed by Engineer-in -charge:- a) Galvanised MS fire buckets 9 litre capacity - 04 No's b) Portable fire extinguisher CO2 type 4 Kg capacity - 04 No's Make:- Ceasefire / Firex/Omex (ABC)
Taking down old unserviceable lightening arrestor 11 KV
S&F of lightning arrestor, Gapless Metal Oxide type, distribution class, System voltage-11KV, Discharge cap-65 KA, Line discharge class-1 complete with bracket and connection complete all as specified and directed.
Mild steel work as in post and struts in fencing including cutting holes to shapes, drilling hole, notching or riveting of steelFe.290.Gde-E-165 etc complete all as specified and directed. Note :- PCC and earth work will be considered seperately for fixing of struts/posts etc
Mild steel screw bolt (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nuts exc 5cm but not exceeding 10cm long, dia of neck 11 to 15mm complete all as specified and directed.
Supply only chain link mild steel galvanised fencing any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc, including provision of binding wire complete all as specified and directed.
Mild steel work of flat, round or square bars in available length conforming to FE 410-W(Gde-E-250) quality 'A' for securing and supporting to chain link fencing complete all as specified and directed.
Preparing new surfaces of steel of any description applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 all as specified and directed
Rendering with cement plaster 10mm thick on fair faces of brick work or concrete surfaces cement plastering 1:6 all as specified and directed
Replacement of old unserviceable solar light fitting >140 Lum /watt MPPT charge , contoller, tilable LED Panel, Adjustable AIO mounting angle, Mono crystalline solar Panel , PIR motion sensor 12 watt ,12.8 volt 12 Ah battery including pole, foundation and all other connected items as per mnufacutrers direction all as specified and directed
Dismentaling anti clambing device barbed wire complete all as specifed and directed.
Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm size including taking down existing danger notice plate complete all as specified and directed.
Replacement of recesses mounted LED ceiling mounted fitting 10 Watt cercular shape multi colour panel (03 colour) 1000 Lm 220-230 volt, AC, 50Hz, PF>0.9, all as specified and directed. Make Crompton/Havells/Orient/Philips
De-hydration/ filtration of transformer oil/ voltage stablizer oil by hiring on line filtration plant to achieve di-electric strength not less than minimum 50 KV including following work services:- (a) Removal of all suspended particles such as dust, rust, scales, collided carbon oxidation sludge etc upto < 1 micron. (b) De-hydration of transformer oil under vaccum. (c) Circulation of heated oil and filling of treated oil in transformer/ voltage stablizer tank. (d) Top up the transformer/ voltage stabilizer oil upto the level. Note : (i)Contractor shall use the vehicle mounted filtration plant eith new suitable size heavy duty hose pipe.(ii) Conducting field testing of di-electric strength of the stabilizer oil before and after filtration. (iii) The stabilizer oil/ transformer oil required for top up shall be measured and paid separately.
M&L for filling / topping of new transformer/ stabilizer oil having dielectric strength not less than 60 KV complete including centrifuging of oil (if required) up to getting dielectric strength not less than 60 KV all as specified and directed by the Engineer-in-Charge.
K S BUILDERS
DAVINDER SINGH
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .