Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.5 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹60.0 L+₹8.4 L (16.4%)Accepted-Finance B 48 SECTOR 65 NOIDA GAUTAM BUDH NAGAR UTTAR PRADESH 201301 | NOIDA | GAUTAM BUDH NAGAR | UTTAR PRADESH | 201301 | L2 | Accepted-Finance L1 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹56 L
EMD Value
₹56,000
Closing Date
22 Feb 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er. Prince Kumar Gautam, EE.
Electricity Construction and Work Division, Moradabad, 220 KV Sub Station Campus, Majhola, Moradabad.
Construction of New 33KV Link Line Gawan from 132 To 33KV Substation Kailadevi, Distt Sambhal.
2024_PVVNL_880795_1
30/ECWD/MBD/2023-24
Open Tender
Fleet Management
Lump-sum
90 days
Moradabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Er. Prince Kumar Gautam, EE.
₹56,000
12 Mar 2024
13 Jan 2024
22 Feb 2024
13 Jan 2024
22 Feb 2024
13 Jan 2024
Note :- Except centralised materials, all required decentralised materials shall be provided by contractor as per RESPO NORMS with approved GTP/DI. Carriage/ Loading & Unloading of Material from any Store Centre under PVVNL, depending upon the availability of material, to site. (For S.no-1.01 to 1.04) 1.01- 9 Mtr. PCC Pole
11 mtr. Long STP, SP-55 round Pole.
13 mtr. Long STP, SP-72 round Pole.
All other Material except Poles (33KV & 11KV Pin, Disc/Fitting, Pin Insulator, ACSR DOG/Rabbit Conductor)
The excavation of foundation pit in mix soil/normal soil/soft & hard rock and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support and Erection of support in the pit, after fixing stone pad including providing of stone pad size 300x300x75mm as per Respo Norms. The work includes carriage and handling of supports from sectional store to pit site as well as fabrication work if required. ( For S. No-2.01 to 2.08) 2.01- 9M Long PCC Pole (Single Pole)
11 mtr. Long STP round Pole. (Single Pole)
13M Long STP, SP-72 Round Pole (Single Pole)
9M Long PCC Pole (Double Pole Structure)
11 mtr. Long STP round Pole. (Double Pole Structure)
13M Long STP, SP-72 Round Pole (Double Pole Structure)
11 mtr. Long STP round Pole. (Four Pole Structure)
13M Long STP, SP-72 Round Pole (Four Pole Structure)
Providing of Earthing of supports with M.S. earth Rod of (20x2500)mm long including excavation of pit and driving M.S.Rod 3.0M apart from suppor and 0.5M below the ground level and connecting belowl the earth electrodes with the help of G.I.wire No.8SWG and including providing & fixing of earthing lugs. Every support & Matelic parts shall be be earth. Respo Drawing no.-DD&SO-27 ( For S. No-3.01 to 3.08) 3.01- 9M Long PCC Pole (Single Pole)
11 mtr. Long STP round Pole. (Single Pole)
13M Long STP, SP-72 Round Pole (Single Pole)
9M Long PCC Pole (Double Pole Structure)
11 mtr. Long STP round Pole. (Double Pole Structure)
13M Long STP, SP-72 Round Pole (Double Pole Structure)
11 mtr. Long STP round Pole. (Four Pole Structure)
13M Long STP, SP-72 Round Pole (Four Pole Structure)
Providing of 33KV X-arm 100x50x6mm (M.S Channel) F-Clamp made of M.S Flate of size 75x10mm and Fixing of 33KV V-type cross arm 100x50x6mm, 33KV F-bracket, 33KV Pin Insulator, 33KV Pin including providing of required clamps, nut & bolt as per Respo Norms. Respo Drawing No.-DD&SO-21Cross arm clamp, F-Clamp made of M.S flate of size 75x10mm ( For S. No-4.01 to 4.03) 4.01- 9M Long PCC Pole (Single Pole)
11 mtr. Long STP round Pole. (Single Pole)
13M Long STP, SP-72 Round Pole (Single Pole)
The work includes carriage and handling of required accessories, from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.5mtr, from M.S.Angle 65x65x6mm/ 50x50x6mm, E-bracket, Disc insulator, top channel 125x65mm, 3200mm, T-off 125x65mm 1600mm, 33KV Disc fitting, 33 KV pin insulator, 33KV Pin etc including providing of E-brackets, required clamps, Nut & bolts as per Respo Norms/ as per schedule with required accessories. Providing as per Respo Drawing No.-DD&SO-20 Cross arm clamp, F-Clamp, Top Channel clamp, made of M.S flate of size 75x10mm, Bracing clamp made of M.S flate of size 65x8mm with Providing of X-bracing 4.5Mtr (M.S Angle 65x65x6mm, Top channel 125x65x6mm 3200mm long, Dropper channel 100x50x6mm 3200mm, T-Off 125x65, 1600mm, E-bracket and other requirement material. (For S. No- 5.01 to 5.05) 5.01- 9M Long PCC Pole (Double Pole Structure)
11 mtr. Long STP round Pole. (Double Pole Structure)
13M Long STP, SP-72 Round Pole (Double Pole Structure)
11 mtr. Long STP round Pole. (Four Pole Structure)
13M Long STP, SP-72 Round Pole (Four Pole Structures)
Grouting of supports in CC 1:4:8 (Cement, sand & 40mm brick ballast). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grit) with muffing as per Respo Norms including providing of requried material. Providing of Ston Pad 300x300x75mm, Work includes back filling and proper ramming. (For S. No- 6.01 to 6.08) 6.01- 9M Long PCC Pole (Single Pole)
11 mtr. Long STP round Pole. (Single Pole)
13M Long STP, SP-72 Round Pole (Single Pole)
9M Long PCC Pole (Double Pole Structure)
11 mtr. Long STP round Pole. (Double Pole Structure)
13M Long STP, SP-72 Round Pole (Double Pole Structure)
11 mtr. Long STP round Pole. (Four Pole Structure)
13M Long STP, SP-72 Round Pole (Four Pole Structure)
Providing of Stay rod (20x1800mm) with 7/8SWG (10Kg stay wire) and Grouting of stay rods(20x1800)mm including all work of excavation of earth 600x600x1300mm as per Respo Drawing DD&SO-31 & concreating in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast) as per respo norms including providing of requried material. Including back filling of soil and proper ramming etc.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per respo norms, including fixing of Stay Insulators of 33KV including providing of stay insulator and stay clamps, nut & bolts, etc. As per Respo Drawing DD&SO-31
Laying, spreading, lifting and final sagging of 3 phases of ACSR Dog conductor in accordance with Line chart including binding and fixing of all accessories in 03Nos. Conductor in parallel. Existing tilted Poles to be made straight, if required.
Providing of P.G.Clamps of proper sizes at all section poles, suitable for Dog Conductor as per respo norms. ( For S. No - 10.01 to 10.02) 10.01- Sectional Double Pole
Sectional Four Pole
Making Jumpers on Section Points, by fixing of P.G.Clamps of proper sizes, suitable for Dog Conductor as per respo norms. ( For S. No .11.01 to 11.02) 11.01- Sectional Double Pole
Sectional Four Pole
Providing of required quantity of 6SWG, 8SWG & 16SWG, GI wire & Guarding angle 75x75x6mm with eye bolt and Guarding between two poles like single poles, double poles, Tri pole, four poles, etc. to guard L.T., 11KV Line telephone and river crossing, road crossing etc. with G.I.wire No.6SWG and G.I.wire No.8SWG, including cutting with fabrication and fixing of guarding angle 75x75x6mm, including providing of requried clamps, nut & bolts, eye bolts etc, as per Respo Norms. Guarding clamp made of M.S Flate 65x8mm.
Providing of danger board at each location as per specification of the respo norms.
Fixing of danger board at each location as per specification of the respo norms.
Providing of Number Plate at each location as per specification of the respo norms.
Fixing of Number Plate at each location as per specification of the respo norms.
Chopping of branches of trees of eucalyptus, Neem, Keekar and other kind of trees along the route of the line and disposal of the same at suitable place.
Making H.T.Connection of the proposed line from Primary 220/132/33KV S/S or from existing 33KV lines/Sub stations. The work consists of fixing & fabrication of Dropper Channels, & fixing of Disc Insulators, Pin Insulators, jumpering with providing & fixing of P.G.Clamps, clamping and binding etc,as per site conditions.
Providing of barbed wire on 33KV SP-72/SP-55 ST Poles/PCC Poles, as anti-climbing device.
Wrapping of barbed wire on 33KV SP-72/SP-55 ST Poles/PCC Poles, as anti-climbing device for a length of 0.9Mtr. Wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a height of 2.75Mtr. from the ground, complete with providing & fixing of lower end & upper end clamps, made of M.S.Flat 40x5mm complete with nuts & bolts as per respo norms.
Painting of following supports/structures of 33KVLine, with two coats of synthetic enamel aluminium paint after one coat of ready mix primer, including provididng of all material (red oxicide and Aluminium paint), as well as rubbing/cleaning of surface as required for proper completion of work . (For S. No-21.01 to 21.06) 21.01- Double Pole Supports (11Mtr SP-55 Poles including all channels/x-arms/clamps etc)
Single Supports (11Mtr SP-55 Poles including all channels/x-arms/clamps etc)
Double Pole Supports (13Mtr SP-72 Poles including all channels/x-arms/clamps etc)
Single Supports (13Mtr SP-72 Poles including all channels/x-arms/clamps etc)
Four Pole Supports (11Mtr SP-55 Poles including all channels/x-arms/clamps etc)
Four Pole Supports (13Mtr SP-72 Poles including all channels/x-arms/clamps etc)
Carriage of Received back material after execution of work for concern store center.
Perennial Contractors Pvt. Ltd.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .