| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86.0 LAccepted-AOC AT 402 NORTH MANGLAM VIHAR COLONY NEAR SAGUNA MORE BAILEY ROAD DIST PATNA | ₹86.0 L | L1 | Accepted-AOC Successful bidder being L1 |
| 2 | L2₹87.3 L+₹1.3 L (1.48%)Rejected-AOC | ₹87.3 L+₹1.3 L (1.48%) | L2 | Rejected-AOC Unsuccessful bidder |
| Sl No | Description | Qty | Unit | Sri Ashok Kalita L2 | KRISHANGI CONSTRUCTION PVT LTD L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil. | 127.8 | cum | 310 ₹39,618 | 304 ₹38,851.2 Lowest |
| 2.00 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. | 63.9 | cum | 398 ₹25,432.2 | 391 ₹24,984.9 Lowest |
| 3.00 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. | 51.12 | sqm | 792 ₹40,487.04 | 777 ₹39,720.24 Lowest |
| 4.00 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources:8 graded stone aggregate 40 mm nominal size derived from natural sources) | 5 | cum | 6,829 ₹34,145 | 6,706 ₹33,530 Lowest |
| 5.00 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level
Concrete of M25 grade with minimum cement content of 330 kg /cum | 53.84 | cum | 8,633 ₹4,64,800.72 | 8,477 ₹4,56,401.68 Lowest |
| 6.00 | Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete | 70.41 | sqm | 332 ₹23,376.12 Lowest | 350 ₹24,643.5 |
| 7.00 | Steel reinforcement for R.C.C. work including straightening,cutting,bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more. | 7,994.4 | kg | 97 ₹7,75,456.8 | 95 ₹7,59,468 Lowest |
| 8.00 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes | 30,000 | kg | 167 ₹50,10,000 | 165 ₹49,50,000 Lowest |
| 9.00 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:
The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items.The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all
complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. | 363 | sqm | 4,830 ₹17,53,290 | 4,743 ₹17,21,709 Lowest |
| 10.00 | Acrylic Alluminium Channeliurn Letter Backside ACP With Front 3MM 040 Acrylic Sheet as base on LED modules of Arihant/Hi sign/StarTech/ (1.20 Watt 3 in one LED module, 100 Lumen per Module, Spread Area 155 degrees along with lens on top for the spot less glow, 6000 to 6500 Kelvin color temperature IP 67 Grade module including 2MM Sheet Metal Cutting Logo, 300watt water proof IP 67/68 grade power supply etc. and Electrical works as specified and directed by the department | 1 | Job | 3,42,884 ₹3,42,884 | 3,36,690 ₹3,36,690 Lowest |
Tender Value
₹80.9 L
EMD Value
₹1.6 L
Closing Date
6 Sept 2025, 2:00 pmClosed
SE PWD Ghy Bldg Circle-II Chandmari Ghy-3
O/o the SE PWD Guwahati Building Circle-II Chandmari
Construction of Entry Gate at Arjun Bhogeswar Baruah Sports Complex
2025_PWBNH_46578_1
SE/BII/GATE/ARJUN BHOGESWAR SPORTS
Open Tender
Civil Works - Building
Item Wise
60 days
SARUSAJAI, GUWAHATI
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
₹1.6 L
Yes
O/o the SE PWD Ghy Bldg Circle-II Chandmari Ghy-3
26 Sept 2025
16 Aug 2025
6 Sept 2025
16 Aug 2025
6 Sept 2025
21 Aug 2025
21 Aug 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources:8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Steel reinforcement for R.C.C. work including straightening,cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items.The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Acrylic Alluminium Channeliurn Letter Backside ACP With Front 3MM 040 Acrylic Sheet as base on LED modules of Arihant/Hi sign/StarTech/ (1.20 Watt 3 in one LED module, 100 Lumen per Module, Spread Area 155 degrees along with lens on top for the spot less glow, 6000 to 6500 Kelvin color temperature IP 67 Grade module including 2MM Sheet Metal Cutting Logo, 300watt water proof IP 67/68 grade power supply etc. and Electrical works as specified and directed by the department
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 20 watt Recessed Downlight
10 watt Recessed Downlight
12 W Flood Light
12 watt spike light
Supplying and fixing of following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral link, earthbar, dinbar, inter connections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door
Supplying and fixing 5 A to32 A rating, 240/415V,10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, four pole, (three phaseand neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required 40A
Supply, laying and testing of under noted sizes of copper conductor XLPE Insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. 4 x 6 sq.mm
Sri Ashok Kalita (BID ID -279982)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .