Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹8.9 L+₹44,904 (5.28%)Rejected-AOC | L2 | Rejected-AOC OTHR THAN LOWEST BIDDER |
Tender Value
₹9.8 L
EMD Value
₹20,000
Closing Date
1 Jun 2023, 6:00 pmClosed
GE (AF) Amla
GE (AF) Amla, Amla Depot Distt Betul (MP) 460553
Upkeeping of Pump house, filtration plants borewells of water suppl installation at AFS Amla
2023_MES_587819_2
8533/E8 OF 2022-2023
Open Tender
Coal Works
Item Rate
335 days
GE (AF) Amla
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹20,000
Yes
21 Jul 2023
3 May 2023
3 Jun 2023
3 May 2023
1 Jun 2023
15 May 2023
Amount
Supply , Installed and testing of LT panel board indoor type, weather and vermin proof, having suitable size factory fabricated, cubical type, made out of CRCA sheet 02 mm thick suitable for 415 volt, 3 phase, 4 wire system with front openable each compartment and locking arrangement with PVC star screwing hinged arrangement, epoxy power coated , internal wiring complete with copper conductor cable for metering system and CT's complete all as specified, comprising by providing of the following equipments /fitments complete:-
a) MCCB, 4pole , 415 Volts of current rating 160 Amps, thermal magnetic release rupturing capacity 25 KA- 01 No(For incoming) b) Star Delta starter Suitable upto for 50HP Centrifugal motor & pump -2NOS c)MCCB, TP , 415 Volts of current rating 100 Amps, -2Nos d)MCB TPN 40 Amps -02 No e)MCB SPN 32 Amps -02 No f)MCB SP 10to 32 Amps -04 No g)Internal Control Wiring with PVC insulated copper conductor multi standard appropriate guage including all coper lugs,CTs and connection incoming/outgoing cable with lugs and cable glands ,connector etc. h)Digital Voltmeter digital (0-500Volt) for incoming & pump motor i)Digital Ammeter(0-100Amps) for incoming & pump motor j)Indicator Lamp LED type for incoming and pump/motor k)Start & Stop Push Button - for starter l)Single phase preventor - 02 No m) Aluminium busbar suitable for three phase four wire system of current rating 200 Amps covered with coloured PVC sleeves as per colour code mounted on DMC insulators -01set
Supply , Installed and testing of LT panel board indoor type, weather and vermin proof, having suitable size factory fabricated, cubical type, made out of CRCA sheet 02 mm thick suitable for 415 volt, 3 phase, 4 wire system with front openable each compartment and locking arrangement with PVC star screwing hinged arrangement, epoxy power coated , internal wiring complete with copper conductor cable for metering system and CT's complete all as specified, comprising by providing of the following equipments /fitments complete:-
a)MCCB, 4pole , 415 Volts of current rating 200 Amps, thermal magnetic release rupturing capacity 25 KA- 01 No(For incoming) b)MCCB, 4pole , 415 Volts of current rating 125 Amps, thermal magnetic release rupturing capacity 16 KA- 01 No(For Outgoing) c)MCCB, 4pole , 415 Volts of current rating 63 Amps, thermal magnetic release rupturing capacity 16 KA- 01 No(For Outgoing) d)MCB TPN 40 Amps -02 No e)MCB SP 6to 32 Amps -06 No f)Internal Control Wiring with PVC insulated copper conductor multi standard appropriate guage including all coper lugs,CTs and connection incoming/outgoing cable with lugs and cable glands ,connector etc. g)Digital Voltmeter digital (0-500Volt) h)Digital Ammeter(0-100Amps) i)Indicator Lamp LED type j) Aluminium busbar suitable for three phase four wire system of current rating 200 Amps covered with coloured PVC sleeves as per colour code mounted on DMC insulators -01set
M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.15mm thick,burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to & including GI earth strip 25 x 4mm as earthing lead by means of bolts, nuts, and washers of galvanised iron or steel all as shown in electrical plate no. 3 of SSR Part I, connected to main switch board and testing on completion with and including necessary earth work in any strata, filling the pit with charcoal and common salt surrounding the earth plate , watering arrangements with 20 mm dia light grade GI pipe, GI funnel with wire mesh, PCC chamber with M-10 using 40mm graded stone aggregates with RCC cover, 550 x 550 x 50mm thick, with type B1, reinforced with 10mm CTD bars @ 150mm c/c, both ways with 2 nos drop handles of 10mm dia round bars 400m long, 40mm bore, medium grade GI pipe for earth lead protection pipe up to test point complete all as specified and directed.
M & L Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI Wire of size 4 mm as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire mesh. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point on completion .(02 for pannel 05 for pole) all as specified and directed on testing on completion.
Supply , Installed and testing of LT panel board outdoor type, weather and vermin proof, having dimension minimum 0.7m x 0.6m x 0.2m factory fabricated, cubical type, made out of CRCA sheet 3.15 mm thick suitable for 415 volt, 3 phase, 4 wire system with front openable each compartment and locking arrangement with PVC star screwing hinged arrangement, epoxy power coated , internal wiring complete with copper conductor cable for metering system and CT's complete all as specified, comprising by providing of the following equipments /fitments complete:-
a)MCCB, 4pole , 415 Volts of current rating 63 Amps, thermal magnetic release rupturing capacity 16 KA- 01 No(For incoming) b)DOL starter Suitable for 5HP Submersible pump -1NOS c)MCB TPN 40 Amps -02 No d)MCB SPN 40 Amps -02 No e)MCB SP 10to 32 Amps -02 No f)Internal Control Wiring with PVC insulated copper conductor multi standard appropriate guage including all coper lugs,CTs and connection incoming/outgoing cable with lugs and cable glands ,connector etc. g)Digital Voltmeter digital (0-500Volt) for incoming h)Digital Ammeter(0-100Amps) for incoming i)Indicator Lamp LED type for incoming and pump/motor j)Start & Stop Push Button - for starter k)Single phase preventor - 01 No l) Aluminium busbar suitable for three phase four wire system of suitable current rating Amps covered with coloured PVC sleeves as per colour code mounted on DMC insulators -01set
S & F in repair Aviation obstruction light on approx 80ft staging overhead water tank with all mounting arrangements, cementing etc having LED 2 X 10W capacity in yellow painted die cast alluminium alloy housing red colour polycarbonate dome and accessories. Make : Bajaj, Havells, Orient Elect
Supply and errect steel tublar swaged poles type 410 SP-31 (7.5 metre long) conforming to IS complete with cast iron base plate, final taper plug, bolts, nuts and screws including painting with two coats of aluminium paint over a coat of primer above GL and black bituminus paint for portion below GL (inside and out side) complete all as specified and as directed. NoTE-Excavation,Earth work & PCC Paid Saperately.
Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed of following sizes.
16 sqmm, 4 core
16 sqmm, 2 core
10 sqmm, 2 core
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
M & L for providing dry river sand as in sand cusioning for underground cable protection including punning down sand in layers complete all as specified & directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supplying and laying unreinforced pre cast concrete Cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40m laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed.
M & L road cutting of size 30 cm width x 45 cm depth for laying of cables incl making good the road with necessary returning fillingand bituminious portion with concret and bituminious mixture and cemented portion with PCC in 1:2:4 , 15 cm thick from top and makeing good damaged surfaces & matching the surfaces with existing all as directed.
Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables complete all as specified and directed
S&F repairs LED flood light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 80 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron braket or GI pipe in angle complete all as specified and directed. make-CG cat no LFL-80-CDL/60-HPM,PHILIPS,Orient Elect
S & F 25 Watt LED Bldg security light with a nominal system l The luminaire shall have rated system lifetime of 50,000 burning hours at L70. The luminaire should have cool white colour temperature (CCT>5000K) and a CRI>70. The luminaire shall meet IP66 rating with THD<20% & pf>0.9. The luminaire housing should be made of pressure die cast aluminimum. The total power consumption should not exceed 25W (including driver) pre wired fitted on and including two Nos PVC block of suitable l size and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmm size and testing complete including LED lamp, including taking down old unserviceable fitting any type complete all as specified and as directed. Make : CG CAT No.LSTS-25-CDL-M or equivalent in , Wipro.
M&L for preparation of old painted surfaces of kerb stone/walls at pump houses and painting of surfaces with two coats of synthetic enamel paint complete all as specified and as directed .
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
M/S J J ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .