| 1 | L1₹22.9 LAccepted-AOC H NO 787 22 JHANG COLONY ROHTAK 124001 | ROHTAK | HARYANA | 124001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.4 L+₹54,617.97 (2.39%)Rejected-Finance 482 GALI NO 4 TULSI VIHAR AZAD NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹25.2 L+₹2.3 L (10.2%)Rejected-Finance H NO 861 12 SALARA MOHALLA ROHTAK 124001 HARYANA INDIA | ROHTAK | HARYANA | 124001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹26.3 L+₹3.4 L (14.8%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L4 | Rejected-Finance L4 | |
| 5 | L5₹26.6 L+₹3.8 L (16.4%)Rejected-Finance 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | L5 | Rejected-Finance L5 |
Tender Value
₹23.4 L
EMD Value
₹46,830
Closing Date
17 Feb 2021, 5:00 pmClosed
Executive Engineer Elect PWD B and R Br Hisar
Executive Engineer Elect PWD B and R Br Hisar
PDG. 11 KV INDOOR ELECTRIC SUBSTATION IN CIVIL HOSPITAL AT TOHANA IN DISTT FATEHABAD.
2020_HRY_154062_2
PWD/Elect-GGN/Elect-HSR/100109
Open Tender
Electrical Works
Works
120 days
Hisar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹46,830
12 Jun 2021
2 Feb 2021
18 Feb 2021
2 Feb 2021
17 Feb 2021
2 Feb 2021
Amount
Moulded case Circuit breakers: Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. Make: L&T/ Siemens/ ABB/ Legrand/ C&S. (HSR 31.12 (C). i) 15 amp.to 60 amp. 415 V ,10 KA 3-phase.
ii) 100 amp.to 220 amp.415 V,10 KA 3-phase.
iii) 250 amp. 415 V , 35 KA 3-phase.
iv) 300 amp. to 400 amp. 415 V , 35 KA 3-phase.
Pipe Laying: Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. (HSR 31.21) vii) Galvanized iron pipe 65 mm dia on surface.
(Q) Earthing (HSR 31.22): i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
iii) Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt ) complete as equired.
iv) Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
v) Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.
x) Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required .
xiv) Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material.
xv) Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material.
xix) Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. staples of same size.
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections. Make: Havell's/ RR Kabel/ Polycab. (HSR 31.26). xxvii) 50 Sq. mm 3.5 Core Ard. Cable.
xxix) 95 Sq. mm 3.5 Core Ard. Cable. (For APFC Panel)
xxx) 120 Sq. mm 3.5 Core Ard. Cable. (For Light Load )
xxxi) 150 Sq. mm 3.5 Core Ard. Cable. (For Power Load)
xxxii) 185 Sq. mm 3.5 Core Ard. Cable . (For Main Load Bank)
xli) 25 Sq. mm 4 Core Ard. Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. (HSR 31.28). iii) 25 Sqmm to 50 Sqmm Cable 2 to 4 Core.
iv) 70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core
v) 120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core
Street Light (HSR 31.30): VI) Supply and erection of prestressed cement concrete pole as per IS : 1678-1960. ii) 9 metres long 105 mm x 115 mm at top and 105 mm x 315 mm at bottom with working load of 200 Kg. burried 1.80 m in ground.
Miscellaneous (HSR 31.35)xi) Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S.rod welded / revitted at the top with 10 cm. Dia 5 mm thick G.I.plate inscribed with `cable' world on it , having a cross arm 30 cm. long of the same dia welded at the bottom , in existing trench 45 cm. below ground level .
Supply installation testing and commissioning of wall/ free standing floor mounting dust and vermin proof compartmentalized cubical panel made out of 2mm thick CRCA street, required hardware 3 mm thick Bakelite sheet provided all along with bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zinc/ Red oxide primer followed by 2 coat of powder coating in gray or required shade after rising. The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking agreement for equipment / switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar Bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars upto cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. the panel will be complete with control wiring (copper) and fuse protection ( only outer area on all sides shall be measured) (HSR 31.63).
Supplying and fixing of copper bus bar duly tinned by means of SMC / BMC type insulator high tensile nuts and bolts spring washer fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect. (HSR 31.64).
Supply and fixing of rotary handle for on/off operation of existing MCCBs in the L.T panel including fixing the same in position with all labour and material required to complete the job in all respect. (HSR 31.66) i) Rotary handle upto 125 A MCCB
ii) Rotary handle above 125 A MCCB
Supply and erection of double walled corrugated (DWC) HDPE pipe laid 1 meter below ground level including digging and refilling of earth including cost of suitable size socket / coupler for HDPE pipe including the cost of the labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (HSR 31.67). ii) HDPE pipe 90/75 mm outer dia / inner dia
iv) HDPE pipe 145/123 mm outer dia / inner dia
Supply and erection of module case circuit breaker single pole/ 4 pole on wall /on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Make: L&T/ Siemens/ ABB/ Legrand/ C&S. (HSR 31.69). iv) 4 Pole MCCB 6 to 63 amp
v) 4 Pole MCCB 100 amp
vii) 4 Pole MCCB 300 amp to 400 amp.
viii) 4 Pole MCCB 500 amp
S/E of XLPE (E) 11 KV HT aluminum conductor armoured cable ISI mark laid in existing pipe /trenches/surface with all labour and material including required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (HSR 31.71). ii) 50 sqmm 3 core XLPE cable
Supply and erection of heat shrinkage type end termination jointing kit indoor type of suitable to accommodate 3 core 11 KV XLPE aluminum cable/ ABC cable complete with all the kit contents including earth continuing connection along with 3 nos. crimpling type aluminum lugs of suitable capacity including making joining etc complete in all respect. (HSR 31.72) i) Suitable for 16 to 50 sqmm 3 core XLPE Cable
Supply and erection of heat shrinkage type end termination jointing kit outdoor type of suitable to accommodate 3 core 11 KV XLPE aluminum cable/ ABC cable complete with all the kit contents including earth continuing connection along with 3 nos, crimpling type aluminum lugs of suitable capacity including making joining etc complete in all respect. (HSR 31.73) i) Suitable for 16 to 50 sqmm 3 core XLPE Cable
Supply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 amp to 400 amp suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel / including making necessary connections with petty material required to complete the job. Make: L&T/ Siemens/ C&S/ GE. (HSR 31.74) iv) 300 amp 4 pole ON load Changeover switch
iv) Load Bank 8 way 400 Amp.
Supply & erection of cable tray made out of 2 mm thick galvanized perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material required to complete the Job in all respect upto the Entire satisfaction of Engineer-in-Charge of the work. (HSR 31.81). i) 40 x 100 mm
Supply & erection of factory manufactured cable tray cover made of 16g GI Sheet complete with Fastener Nuts bots and in position including all petty material required to complete the Job in all respect upto the Entire satisfaction of Engineer-in-Charge of the work. (HSR 31.82). i) Size for 40 x 100 mm
Cement Concerete Platform:- (For Transformer): Earth work in excavation in fundations, trenches, etc in all kinds of soils, not exceeding 2 Meter depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsquent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed with a lead of 30 metes. (HSR 6.6)
Cement lime concrete 1:8:16 withj brick blast 40mm nominal size in foundation and plinth. (HSR 10.26)
Cement concrete 1:2:4 with slone aggregate 20mm nominal size in foundation and plinth. (HSR 10.41)
First Class bricks work laid in cement sand mortar 1:6 in foundation and plinth.(HSR 11.2)
11:43 cm thick bricks wall laid in cement sand mortar 1:4 without rainforecement, in foundation and plinth. (HSR 11.47).
Conglomerte floor 50 mm thick CC topping 1:2:4 (HSR 14.10)
12 mm thick cement plaster 1:6 (HSR 15.7)
(I) Steel Rainforcement: Mild steel reinforcement for RCC works where not included in the complete rate of RCC, including bending, binding and placing in position complete. (HSR 18.21)
Non Schedule items : Supply and erection of Rubber Mat 1mx2mx 12mm thick suitable for 11/33 KVA as per IS No. 15652C/M/L 3017739 as per approved by Chief Electrical inspector, Govt. of Haryana.
Transformer: Supply, and erection, testing and commissioning of outdoor transformer of 250 KVA 11/0.433 KV 3 Phase 50 cycle copper wound Outdoor type up to the entire satisfaction of the engineer of the work as per detail specification given as under with required plate form & fancing etc. As per Latest BIS-1180-Level-2 or latest specification. Make. Kirloskar/ ABB/ Siemens/ Alstom/ NEFG/ Bhart Bijli/. NO load voltage ratio 11/0.433 KV No. of Phases = 3 Type = Double wound core type copper wound, Cooling = ONAN Duty = Outdoor Vector Group/ISS-DYN- 1/IS: 1180- Level -2. Tapping on HV compensation + 5% to - 10% in steps of 2.5%. Tape changer - Off circuit Temperature rise (oil/res. 0c to 50/55 C) Altitude up to 1000M above M.S.L. Frequency Cycle 50 Hz. Fitting / accessories provides = Off circuit tape changer Externally hand operated Oil conservator with filling hole & cap. Plain oil level gauge with minimum level marking. Thermometer pocket. 4 Nos. plain roller Uni-directional Silica-Gel-Breather Ist filling of oil Drain-cum-filter valve Rating & Diagram plate Two earthing terminals Lifting arrangement Exploson vent Air release plug Oil temperature indicator with alarm & trip indicator. Winding Temperature indicator with alarm & trip contact. TERMINATIONS:HV=3 pole single glands cable box suitable for reception of 1 No. 3 core up to to 120sqmm XPLE cable copper lugs/thimble. L.V. = 4 pole 3 glands cable boxes suitable for 3 Nos. 400 sqmm. 3.5 core PVC cable having extended copper bars of requisite capacity duly tinned from L.T. bushing for making connection with cable including cost of copper lugs and thimbles. L.V. Neutral suitable box for earthing provided.
Supply Erection testing & Commissioning of 11 KV HT metering panel complete with C.Ts P. Ts. Cubical and electronic meter with accuracy class as per requirement/approved by DHBVN at the time of installation, consisting of the following. (As per Approved by DHBVN). Cubical panel free standing floor mounting type made out of sheet steel 14 SWG CRCA sheet with channel iron base frame spray painted with strong synthetic light grey enamel paint as per size and design approved by the DHBVNL 3 Nos. 11 KV CTS of rating as approved by DHBVNL for indoor installation of appd. Make of 1 Nos. 11 KV PTs 11000/110 Volts Oil filled suitable for indoor installation of approved make DHBVNL. Space for Digital Electronic Meter 3 phase 4 wires recording in KWH and rating and accuracy as by DHBVNL with push button display operating system of different kind of readings. The cubical panel will be completed in all respect including intter connection, internal wiring with PVC copper cable, its testing and approval of all item by DHBVNL including cost of all testing/ approval charges of all items of DHBVNL with a guarantee of one year from the date of commissioning including cost of all labour and material required to complete the job but excluding the cost electronic meter in all respect up to the entire satisfaction of the engineer in charge of the work.
POWER FACTOR PANEL 80 KVAR: Supply erection, testing & commissioning of cubical type panel dust & vermin proof. L.T. automatic power factor control panel 80 KVAR capacity suitable for automatic operation & control of power factor within the set limits free standing floor mounting made out of 14 guage mild steel with channel iron base frame ainted with stove synthetic light grey enamelled paint suitable for operation on 3 phase 4 wire 50 cycle per second 400/440 volts A.C. supply equipped with the following as per diagram attached: 1 No. automatic power factor control relay of EE Co./ L&T make. Power factor meter size 96 x 96mm of AE make. Space for incomer 200 amp. triple pole moulded case circuit breaker. A set of pilot lamps (3 Nos.) phase indicating lamp of L&T make. Iron clad bus bar chamber suitable for 200 amp. 440 volts having 4 No. copper bars of cross section 25 mm x 5mm duly tinned and insulated with PVC sleeves. Connection from incomer moulded case circuit breaker to bus bar by means of solid copper strip of requisite capacity duly tinned & insulated with PVC sleeving. 3 Nos. 3 phase 20KVAR dry capacitor of MPP type iemens / L &T make (totaled 60 KVAR) 2 Nos. 3 phase 10 KVAR dry capacitor of MPP type Siemens/ L&T make (totaled 20 KVAR) 2 Nos. 3 phase 32 amp. contactor for 10 KVAR capacitor of L&T /Siemen make 3 Nos. 3 phase 63 amp. contactor for 20 KVAR capacitor of L&T /Siemen make 6 Nos. 32 amp. HRC fuse with holder of L&T /GE make. 12 Nos. 63 amp. HRC fuse with holder of L&T /GE make. 3 Nos. indication Lamps 220 volts for ON indicator of respective capacitor of L&T make. 12 Nos. push button ON/OFF manual operation of L&T make Earthing copper bus bar of cross section 20 mm x 3 mm duly tinned and insulated throughout the lenght of panel. The panel will be complete with all internal wiring with PVC copper wire, inter connection etc. with all labour and material require to complete the job in all respect without cost of MCCB upto the entire satisfaction of the Engineer-in-charge of the work.
S/E of fire bucket 9 Ltrs Capacity of G.I. sheet of 24 gauge write with " FIRE" as per fire specification.
S/E of MS bucket stand suitable for six Nos. fire buckets (but without buckets) including the cost of welding & painting with all cost of red oxide and two coat of enameled paint of red colour completion all respect.
Supply and erection of stay wire suitable for 9/11 M. long RCC pole make out of 7/8 SWG GI wire with U type MS rod 5/8" dia duly threaded by means of angle iron of size 50 mm x 6 mm x 30 cm and 6 ft. long MS rod 5/8" dia 5' buried in the ground after fixing with cross channel size 75 mm x 40 mm x 60 cm. The stay wire will be binded on the top of the pole with help of suitable size of double U type MS clamps and stay fixed with nuts& bolts. The stay wire shall be insulated in the middle point with the help of egg. Insulator and complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work.
Supply and erection of 11 KV pin insulator with pin make with all labour and material required to complete the job including fixing the same on existing channels up to the entire satisfaction of Engineer-in- Charge of the work.
Supply and erection of 11 KV gang operated switch make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing 'H' pole with the help of 3 No. channels of size 75 mm x 40 mm x 6 mm, 1.8 M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 No. 11 KV insulator with GI pin R.D. fuses and painting with 2 coat of approved paint and one cost of red oxide and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of work.
Supply and erection of 11 KV disk insulator with all labour and material required to complete the job including fixing the same on existing channels up to the entire satisfaction of Engineer-in- Charge of the work.
Supply and erection of lightening arrester module suitable for 11 KV G.O. switch with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work.
S/E angle iron, channel & clump with nut & bolts of various sizes required for made the platform & G.O. switch etc.
Supply & erection of fire extinguisher ISI marked ABC type 6 Kg. Capacity powder base with square grip Gavle duly erected/hung on wall with hook including the cost of hook, screw etc. with all the labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-In-Charge of the work.(Make:- Safex/Ceasefire/ Minimax).
Supply & Installation of CO2 type fire Extinguisher 4.5 KG capacity made from brand new seamless cylinder as per ISI mark IS: 7285 and CCE approval fitted with discharge hose and horne and squeeze grip /wheel type valve with initial charge as per IS 15683 : 2006 specification bearing ISI marks and EIL approved complete in all respect (Safex/ Minimax Make) with Three year warranty.
Virender Singh prop. Balaji electric company
Vijender Kumar Contractor
M/s JSB Enterprises
J.B.S.Electrical Co.
KHUSHI ELECTRICALS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .