Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.0 Cr+₹6.3 L (3.20%)Rejected-AOC | ₹2.0 Cr+₹6.3 L (3.20%) | L2 | Rejected-AOC L2 |
| 3 | L3₹2.1 Cr+₹8.6 L (4.33%)Rejected-AOC 159 KAILASH GHOSHI ROAD KOLKATA WEST BENGAL 700008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | ₹2.1 Cr+₹8.6 L (4.33%) | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹3.8 L
Closing Date
17 Dec 2019, 5:30 pmClosed
SE(E/M)-II, KMDA
OFFICE OF THE SUPERINTENDING ENGINEER (E/M)-II, E-M SECTOR, K.M.D.A. UNNAYAN BHAVAN, 6th FLOOR, SALT LAKE CITY, KOLKATA 700 091.
Internal and external wiring, illumination and allied works and allied works for G5 building at Logistic Hub at Garden Reach as Phase-I.
2019_KMDA_255155_1
SE(E/M)-II/2W-66/2019-20/350
Open Tender
Electrical Work/ Equipment
Item Rate
120 days
Garden Reach
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹3.8 L
OFFICE OF THE SUPERINTENDING ENGINEER (E/M)-II
18 Mar 2020
25 Nov 2019
19 Dec 2019
25 Nov 2019
17 Dec 2019
27 Nov 2019
4 Dec 2019
Amount
Supply & Installation of LT Panels
Supply & Installation of Distribution Board with ACCL for dual power input and common output with provision of kWH meter, all complete including all sundries, fixtures for installation as per specifications for Logistic Hub Block-A, with all complete including all sundries, fixtures for installation as per specification.
Supply & Installation of rising Main & Bus Trunking system
Supply of 1600 amps rated current,1000 V grade, 3 Ph 4 wire (100 % neutral) , IP-55, Class insulated Sandwich Type bus bar trunking system suitable for vertical installation of power distributrion in the floors system with conductor made from alluminium alloy,(Cu Plating + Tin Plating )with enclosure made from 1.5mm hot dip galvanised sheet steel and painted with RAL 7035 resins high resistance to chemical agents , fire retardant with 50KA short time current withstand capacity for 1 sec with 3 nos plug outlets in each floor including factory fitted junction monoblock , IP 55 junction , IP 55 outlet cover , spring brackets , standard support brackets , with two runs of AL earth strips and system should be in compliance to latest IEC 61439-6.
1600 amps (SC rating for 1 sec- 50 KA)- 50 running meter
Supply of 1600 amps capacity end feed unit with termination flange made from 1.5 mm powder coated sheet steel provision for fixing 4P,50KA ACB. With interconnection cable end box , earthing etc as required to complete. 2.a)1600 amps End Feed - 2 Nos.; 2.a)1600 amps, 4P, 50 KA, MDO ACB - 2 Nos.; 2.a.3)Supply of the following capacity Tap off boxes (Plug in type ) with cover inbuild with AC21A off load disconnection device provision for fixing 4P ,36KA , MCCB with short circuit and overload protection (Thermal Magnectic Release) with operating handle interconnection, cable end box, cable gland, earthing etc as required to complete to supplying 3 phase power to floor panels /DB.; 2.a)250 amps Tap Off box + ROH : 6 nos.; 2.a)250 amps 4P, 36KA , MCCB . : 6 Nos.; 2.a)630 amps Tap Off box + ROH : 4 nos.; 2.a)630 amps 4P, 36KA , MCCB . : 4 Nos.; 2.a.5)Installation Testing Commisioning of Raising Mains systems including Tap off boxes and end feed units and other accessories nessesary to complete the rising mains system.; 2.b.1)Supply of 1000 amps rated current,1000 V grade, 3 Ph 4 wire (100 % neutral) , IP-55, Class insulated Sandwich Type bus bar trunking system suitable for vertical installation of power distributrion in the floors system with conductor made from alluminium alloy,(Cu Plating + Tin Plating )with enclosure made from 1.5mm hot dip galvanised sheet steel and painted with RAL 7035 resins high resistance to chemical agents , fire retardant with 50KA short time current withstand capacity for 1 sec with 3 nos plug outlets in each floor including factory fitted junction monoblock , IP 55 junction , IP 55 outlet cover , spring brackets , standard support brackets , with two runs of AL earth strips and system should be in compliance to latest IEC 61439-6.; 2.b.1.1)1000 amps (SC rating for 1 sec- 50 KA)- 50 running meter; 2.b.1.2)Supply of 1000 amps capacity end feed unit with termination flange made from 1.5 mm powder coated sheet steel provision for fixing 4P,50KA ACB. With interconnection cable end box , earthing etc as required to complete. ; 2.b)1000 amps End Feed - 2 Nos.; 2.b)1000 amps, 4P, 50 KA, MDO ACB - 2 Nos. ; 2.b.3)Supply of the following capacity Tap off boxes (Plug in type ) with cover inbuild with AC21A off load disconnection device provision for fixing 4P ,36KA , MCCB with short circuit and overload protection (Thermal Magnectic Release) with operating handle interconnection, cable end box, cable gland, earthing etc as required to complete to supplying 3 phase power to floor panels /DB. ; 2.a)630 amps Tap Off box + ROH : 2 nos. ; 2.a)630 amps 4P, 36KA , MCCB . : 2 Nos. ; 2.b)250 amps Tap Off box + ROH : 5 nos. ; 2.b)250 amps 4P, 36KA , MCCB . : 5 Nos. ; 2.b.4)Installation Testing Commisioning of Raising Mains systems including Tap off boxes and end feed units and other accessories nessesary to complete the rising mains system.
Supply & Installation of Cable Tray
Supply & Installation of MS Section for Cable Tray and Support
Supply & Installation of G. I. Perforated Cable Tray with cover 200 x 40 mm
Supply & Installation of G. I. Perforated Cable Tray with cover 150 x 40 mm
Supply & Installation of Cable Termination
Supply of LT Cable Termination Kit as per Cable Schedule.
Supply & Installation of 1.1 KV Al grade PVC AR insulated L.T Cables
1100 Volts 3.5 Core different size Al, Power Cable as per site requirement.
Supply & Installation of 1.1 / 0.65 kV grade PVC AR Control Cables
660 Volts Grade Multicore armouredAl conductor PVC insulated power Cables as per site requirement
Carry out all pre-commissioning tests & activities as per specification and direction to make the installation ready for trial run.
Trial run for 72 hour of the whole installation, making field performance tests of all installation and commissioning of the installation all complete as per specification and direction. (Rate-Reference: to 8- Market Rate
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 63 A DP MCB ( SEI/Legrand/ABB).
Supplying and fixing MCB SS enclosure 4 Way with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, ( SEI/Legrand/ABB)
Supplying and fixing double-door SPN MCB Distribution Board with 6-32A MCB& 63DP MCB isolator with IP-42/43 protection,concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2+12Way,12no MCB, 63 amp DP isolator ( SEI/Legrand/ABB)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (approved make) in suitable size PVC casing-capping (Precision make) and partly in 19mm bore, 3mm thick polythene pipe, with 1x22/0.3 (1.5 sqmm) for ECC incl. necy. fittings to light/fan/call bell points with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casing-capping on Wall and drop & switch box surface]
i) Average run 6 mtr
Distribution Wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (approved make) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) for ECC incl. necy. fittings to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex (wall matching color) top cover of 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on Wall]
i) On Board
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall by Electric operated cutting incl. making earthing attachment, painting and mending good damages to building works
i) 100 mm x 100 mm x 65 mm
ii) 150 mm x 100 mm x 65 mm
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
Supply delivery of follwing 1.1 KV grade heavy duty cable as per direction of EIC(Havells and Equivalent)
i) 2 Core 16 sq mm UN AR AL Cable
Laying of cable upto 2 core 25 sq mm on wall/surface incl. S & F MS saddles with earthing attachment in 2x10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
i) 2C x 16 sq mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
i) 2C x 16 sq mm
Supply & Delivery and fixing at site the following fittings & fixtures as per specification
a) Luminaire with Twin tube (LED)
b) 1200 mm Sweep AC Ceiling fan
c) 12 inch exhaust fan
d) 9 inch exhaust fan
Supply installation commissioning of steel octagonal street light pole (slotted)7 M length, weight 99 Kg. incl. Excavation of earth and reinforcement CC foundation(1:1.5:3),shuttering, foundation bold 750 mm length, dia M - 4 nos., base plate 225 sq mm and thickness of plate 16 mm with earthing attachment and bakelite terminal etc complete as per drawing.
S & F of single arm bracket 1.5 M length incl. set screw, Nut, Bolt, washer etc complete
Supply of 4 core 16 sq mm PVC armoured AL. cable (Havell/NICCO/GLOSTAR) for street light.
Laying the upto 4 core 16 sq mm PVC insulated A/Al through Pole after necessary making holes on Pole.
Laying the 4core 16 sq mm A/AL cable through existing nylon pipe incl. excavation of earth 460 mm X 760 mm Avg. depth incl. filling the shifted soil levelling up and restoring surface duly rammed.
Laying of cable upto 4 core 25 sq mm on wall/surface incl. S & F MS saddles with earthing attachment in 2x10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supply & fixing compression type cable gland incl. all accessories a) 4 Core 16 sq mm armoured cable
Finishing the end crimping method of the above cable incl. supply and fixing (Dowels make) solder less socket, tape, anticorrosive paste incl. connection complete. a) 4 Core 16 sq mm armoured cable
Supply & delivery of 2” dia nylon pipe for cable protection
a) Supply, installation testing and commissioning of LED type BRP410 LED CW 072 MR FG S1 PSU GR (Philips) street light luminaries incl. LED lamp (Philips) etc complete.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm
Earthing with 50 mm dia ISI-Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below (ISI Medium, for soft soil):
Supply & erection of M.S Pillar box size 5’ height x 2’-6’ width x 2’-0” depth made by 6 mm thick Leaf type door in both side including 50 mm x 50 mm x 6 mm. Angle in frame and 2 Nos. RAILWAY TYPE locking arrangement on both sides 2 Nos.6” Tower bolts to be fixed on both sides (upper & lower portion) 1 No vent door, 1 No 4-lever Pad lock (Godrej) to be fixed on both sides, suitable size Teak Wood Board to be fixed on the Pillar box, gland plate in the bottom section, 4 Nos. Angle iron leg (50mm x 50mm x 6 mm size 1’-10” long below G.L., fixing by brick protection, plastering, neat cement finishing. 1 No 63A, TPN, re-wireable type, sheet steel enclosure switch fuse unit (HAVELLS) 3 Nos. 63 A, TPN, re-wireable type, sheet steel enclosure switch fuse unit (HAVELLS). 1 No single dial timer (GIC) 1 No – 4 Pole 70A contactor (L&T) (M.L- 4) 1 No toggle switch (Best quality) 1 No, 100A, TPN, copper tinned copper bus bar (Size of copper bar 25mm x 6mm x 460mm) with bus bar chamber. On inter connection by suitable size copper wire painting of pillar box 2nd coat of Aluminium paint over 1st coat of Red oxide Priming etc. complete as per drawing.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium)Protection with necessary fittings and jointing metarials as required a)50 mm dia
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar including S & F GI (Hot Dip) wire of size 8 SWG on wall/floor with staples buried inside wall /floor as required and making connection to equipments incl. drilling holes, with bolts, nuts, washers etc
Supply, installation, testing and commissioning of LED glow sign board including MS structure painting and as per direction of EIC.
Supply & fixing, fitting of lightning arrestor/ conductor of G.I stick of size 1x5 Mtr long x 25 mm dia with G.I flange at bottom of size 75 x 75 x 5 mm thk.with copper discharge points including grouting by cement morter 1:4 as per direction of EIC.
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint
G B CONSTRUCTION
POWER INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .