| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹41.0 L+₹1.1 L (2.64%)Rejected-Finance MAKARDHA PO MAKARDHA PS DOMJUR BANERJEEPARA WEST BENGAL 711409 | HOWRAH | WEST BENGAL | 711409 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹41.4 L+₹1.4 L (3.50%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹42.4 L+₹2.4 L (6.12%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹43.1 L+₹3.2 L (7.98%)Rejected-Finance OPPOSITE GATE NO 2 NORTH BENGAL UNIVERSITY PO N B U DIST DARJEELING WB | DARJEELING | DARJEELING | WEST BENGAL | 734013 | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
2 Sept 2022, 6:00 pmClosed
GE AF BAGDOGRA
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
REPAIR AND MAINTENANCE TO LIGHTENING PROTECTION, EARTHING, FIRE ALARM SYSTEM AND ALLIED WORKS AT 273 SU AND 20 WING AFS BAGDOGRA UNDER GE (AF) BAGDOGRA
2022_MES_538525_1
8442/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Bagdogra
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Bagdogra
₹63,000
Yes
14 Sept 2022
20 Jul 2022
3 Sept 2022
20 Jul 2022
2 Sept 2022
27 Aug 2022
Amount
Material and labour for Test point terminal block in repairs as made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete all as specified & directed by Engr in Charge.
Material & Labour in repairs for earth result marker board of MS sheet 3.15 mm thick with suitable board size of MS flat of 30 X 20cm and 1.2 mtr long and 1 mtr above ground level after proper grouting in ground with suitable PCC work and painting with suitable colour all as directed. Note:- Legend to be used for Shapes, size and colour of paint as per existing nature of earthing or as directed by Engr-in-charge.
S&F in repairs air termination single pointed copper rod 12mm dia and 300mm long with fixing socket including dismantling old one complete all as specified and as directed.
S&F Air termination copper rod 12 mm dia, 1.00 mtr long single point including base plate and dismantling old one all as per specified and directed.
Taking out and removing earth strip any size any description all as specified and directed.
S&F galvanized iron strip of size 25 x 4 mm as earth continuity conductor buried in ground or fixed to wall/floor/ground provided with porcelain insulators space no less than 0.5 mtrs complete all as specified and directed.
All as item No 6 here–in–before but of size 32mm x 6mm.
Supply, fixing and brazing in replacement of Earth continuity conductor with adequate size insulator fixed to wall on batten or recess or any other indicated situation for loop earthing etc. as required 32mm x 6mm copper strip complete all as specified and directed.
All as item No. 08 here–in–before but of size 20mm x 3.15 mm.
Labour only for electric Welding of existing GI strip of any size, any height (on roof/ on wall) at various places complete all as specified and directed by Engr in Charge.
Labour only for Brazing of existing copper strip of any size, any height (on roof/ on wall) at various places complete all as specified and directed by Engr in Charge.
Improvement to chemical earthing with supply & fixing in repairs of earthing improving Black fill compound (Electrodite) of 25 Kgs bag for improving earthing result by excavation till middle of the earthing electrode and filled with Black Fill Compound (Electrodite) for any type of earth electrode and making earth strip connection good as per the existing one before the excavation and finally testing & recording the results complete as per site requirement and all as specified & directed. Make :- ASHLOK Black Fill compound (Electrodite) or any make as approved.
Improvement to earthing for conventional GI/ Copper earth electrode having high ER value by excavating soil around earth pit filling of agricultural soil obtained from non defence land, filling mixture of salt and charcoal 0.2 Cum around the earth electrode re-filling soil and fixing the PCC pit, watering and finally testing & recording the results complete as per site requirement and all as specified & directed . Note: (For Item Nos. 12 & 13 above):- Cost of agricultural soil upto one cum as brought to site for improvement of earthing deemed to be included within quoted rate by the contractor. Earth Work like excavation, returning-filling and removal of surplus soil shall be measured and paid separately under relevant item.
Material & Labour for testing of earthling pits any type, duly disconnecting by test point and other loops. The test shall be carried out using ISI marked digital/Analog earth of reputed make. Test result shall be marked on earth value indicators at site and enterd in a Earth Testing register after testing all as per directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, earthing pit etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L in repairs for 40 mm bore GI pipe light grade ISI marked for earth strip protection/ for lightening arrester with all fixing accessories for copper strip such as, Nut bolts and washers insulator with necessary brick work for fixing GI pipe complete all as specified and directed by Engr-in-Charge.
Material & Labour in repairs for Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thickness buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl copper strip 20 x 3mm by means of nuts & bolts, check nuts and washers of brass incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25 x 25 x 3mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 40mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate no 3 of MES SSR Part I 2009 connected board all as specified and testing on completion. (Note:- the earth resistance should be less than one ohms and GI protection pipe and earth lead more than 7.5 RM shall be measure and paid separately.)
All as per item No. 19 above but using 32 x 6mm thick copper strip.
Material & Labour for safe earthing electrode (SEE) designed with pipe technology with hot deep Zinc coated & Alloy coated (80 – 100) microns MS pipe size of outer pipe 76.3 mm dia and inner pipe 41.9 mm, 3 mtr long inside filled with ) crystalline conductive mixture (CCM) having non corrosive and conductive properties complete with two bag of Black filled compound (Electrodite) mixed with soil all around the earth pipe for smooth charge dissipation complete with PCC earth pit made in cement mortar of 1:2:4 type B-1 with 20mm graded aggregate of size 450 x 450 x 450 mm with RCC pit cover. Make :- Ashlok Model No : ASEEL-39-ZC & AC (76.3mm Dia) or equivalent make as approved. (Note:- the earth resistance should be less than one ohms and GI protection pipe and earth lead more than 7.5 RM shall be measure and paid separately).
M& L for earthing complete with galvanized iron earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 3.0 mtr below normal ground level connected to galvanized earth strip 32mm x6mm thick by means of bolts nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-5 of SSR part-1 connected to earthing test point all as specified or indicated including PCC pit in PCC (1:3:6) type CI cast iron frame 50mm thick pre cast RCC (1:2:4) nominal mix cover slab reinforced with 8mm dia mild steel bar including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50mtr and funnel with watering pipe wire mesh GI protection pipe 40mm bore including testing complete all as specified and directed by Engineer-in-Charge. (Note:- the earth resistance should be less than one ohms and GI protection pipe and earth lead more than 7.5 RM shall be measure and paid separately).
All as per item No. 22 above but using 25 x 4mm thick GI strip.
S & F in repairs porcelain ridge insulator of size 75 x 35 x 40mm with 01 No. GI blot of 65mm dia and 40mm long including nut & washer and 02 Nos GI bolt of 10mm dia and 50mm long including nut & washer for holding/fixing copper/GI / Aluminium strip on roof/ wall complete all as specified and directed.
Material and Labour in repairs for GI funnel and wire mesh for earth pits complete all as specified & directed by Engr-in-Charge.
Material and Labour in repairs for precast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:4 with PCC lean concrete 1:3:6 type C1 (using 20mm graded aggregate) suitable size for earth pit for any type of earthing complete all as specified and directed by Engr in Charge.
Material and Labour in repairs for providing precast cement concrete in landings, cover slabs (for man holes etc.) and similar articles with plain faces etc. and setting in cement mortar 1:4, Type B-1, 1:2:4 using 20mm graded aggregate, suitable for RCC earth pit cover reinforced with XPM, weight not less than 4 Kg/Sqm and 6mm dia bar handle complete all as specified and directed by Engr in Charge. (Note :- Precast cement concrete item shall be reinforced, where indicated and reinforcement shall be measured separately).
Material and Labour for mild steel round bars 6mm to 8mm dia and cut over to length, bent to shape required, including cranking, bending spirally for hooping for RCC earth pit cover reinforced and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as per site requirement as specified and directed.
Provision of services excluding spares for periodical maintence of conventional fire alarm control panel, AC filter Transformer lead and batteries. Multisensor, Sounder, MCP, Remote response indicator carrying out normal repair for the trouble free and efficient functioning of the entire fire system by providing one engineer for monthly visit one all as directed and as per specified in NFPA 72 guideline. Note:- Necessary spare if any will measured and paid separately as supply only.
Dismantling, servicing of all optical conventional smoke detector as per exact location with the help of manufacture's instruction and testing for exact fault location including cleaning through air blower then reinstalling complete all as specified and directed every six months.
Supply only optical conventional smoke detector LPCB. (Make: Agni/ System sensor/ GST as approved by GE.)
Supply only two wire plug in detector base. (Make: Agni/ System sensor/ GST as approved by GE.)
Supply only conventional MCP RED with LED 470 ohms W/O black box India + surface mounting box red. (Make: Agni/ System sensor/ GST as approved by GE.)
Supply only conventional HORN CUM TROBE wall RED standard candela India. (Make: Honeywell/ Agni/ GST as approved by GE.)
Supply only 4 zone conventional fire alarm panel. (Make: Honeywell/ Agni/ GST as approved by GE.)
Supply and fixing of 12v 7AH battery for backup to all FACP and RTU panel. (Make: Exide/ Amaron/ GST as approved by GE.)
Taking down old unserviceable light fittings from pole/wall after disconnection the connecting wires of any type or size and S&F Energy efficient LED Street Light / Roadway Luminary, high PF, 60W, 6000K, energy saving and environmental friendly long life versatile pressure die cast aluminium housing, toughened glass cover, IP 66 protection, 240V, using 1.5 Sqmm, PVC insulated sheathed three core multistranded copper conductor cable, 1100V grade (upto 3.0 Mtr) for connection passing through bracket/pole as per site requirement, testing & commissioning and as directed.
All as per item No. 1 above here-in-before but for energy efficient LED Street Light / Roadway Luminary, high PF, 90W, 6000K.
Taking down old unserviceable light fittings from pole/wall after disconnection the connecting wires of any type or size and S&F Energy efficient LED Flood light Luminary, high PF, 80W, energy saving and environmental friendly and efficacy of not less than 110 Lm/w, long life versatile pressure die cast housing IP 66 protection, 240V, using 2.5 Sqmm, PVC insulated sheathed three core copper conductor cable, 1100V grade (upto 3.0 Mtr) for connection etc as per site requirement, testing & commissioning and as directed.
All as per item No. 3 above here-in-before but for Energy efficient LED Flood light Luminary, high PF, 120W.
Supply & Fixing in replacement of LED Highbay, 80W LED, with high luminous efficacy upto ≥ 100 LPW IP66 protected, front toughened glass, with discrete high lumen LED, energy saving, long life with all accessories, 240V, using 2.5 Sqmm, PVC insulated sheathed three core multistranded copper conductor cable, 1100V grade for connection passing through PVC Conduit upto 25mm size as per site requirement, testing & commissioning and as directed.
All as per item No. 5 above here-in-before but for LED Highbay, 120W LED.
S&F in replacement of LED post top Lantern E-Top 30 Watt with low glare optical design acrylic opal diffuser with spigot made up of cast aluminium and wired with all accessories, 240V, including taking down of old unserviceable light fitting, pre-wired using 1.5 Sqmm, PVC insulated sheathed three core multistranded copper conductor cable, 1100V grade (Upto 3.0 RM) for connection passing through PVC Conduit or pole, from junction box to light fitting as per site requirement, testing & commissioning and as directed. using 1.5 Sqmm, FRLS PVC insulated sheathed three core cable, 1100V grade with multistranded copper conductor (Upto 5.0 RM) passing through PVC conduit or pole, from junction box to light fitting and testing & commissioning. (Make: C&S/Crompton/HPL/Bajaj/Havells)
Supply & fixing in replacement of 9/10 Watt LED Bollard decorative light Glaze fitting with low glare diffuser including taking down of old unserviceable light fitting and necessary PCC work 1:2:4 of adequate size for fixing of bollard fitting as per site requirement, testing & commissioning and as directed. (Make: HPL Cat No. HPLLEDB9W or equivalent make of C&S/Crompton/Bajaj/ Havells).
Supply and fixing in replacement of LED aviation light fitting 10Watt, 240V with comprising of aluminium housing with red polycarbonate dome for better illumination , 302 x 5mm LED, IP 66 protection including taking down of old unserviceable light fitting complete all as per site requirement and as directed. (Make - Bajaj Cat Part No BGAV 302 LED or equivalent make ISI Mark as approved)
S&F PVC weather proof, hinged door, junction box with, 240V, Neutral link, three phase connector, with IP 66/67 protection suitable for outdoor installation on pole/wall surface and including with 1No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc including dismantling old unserviceable junction box all as directed. (Make : Sintex Cat Part No. GSMB 2520, Hensel Cat Part No KF 2500H or equivalent of ISI Mark as approved)
Supply, fixing and connecting in replacement of PVC insulated sheathed multistranded 3 core cable FR grade of size 4.0 sqmm with copper conductor including passing through PVC conduit along the pole, on wall surface or in trenches from existing light fitting to existing junction box and all as per site requirement and as directed.
All as per item No. 11 above here-in-before but for PVC insulated sheathed 3 core cable of size 2.5 sqmm with copper conductor.
All as per item No. 11 above here-in-before but for PVC insulated sheathed 3 core cable of size 1.5 sqmm with copper conductor.
Taking down and S&F brackets made out of 40mm bore GI pipe, medium grade, 1.5M long, bend to shape and fixing with MS clamps made out of flat iron, with replacement of necessary nuts, bolts, washers etc and painting of bracket and clamps with 2 coats of synthetic enamel paint over a coat of red oxide zinc chromate primer complete as per site requirement and directed.
Taking down existing unserviceable clamps and S&F new clamps made out of 40 x 6 mm bending to shape, drilling holes for bolts suitable for fixing GI pipe bracket of 40mm dia to steel pole, made in two halves, including nuts, bolts, washers and painting with two coats of aluminium paint over a coat of red oxide primer, complete as per site requirement and directed.
Supply & fixing rigid non-metallic, ISI marked, PVC conduit, smoke free, fire retardant, and temp stable quality of size 20mm external dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, etc., and including all fixing accessories such as couplers, lock nuts, saddles/clamps, pipe hooks for securing of electric wires/cables of any type and size as laid along the pole or on wall surface of ISI make as approved including taking down existing conduit.
All as per item No. 16 above, but of size 25mm external dia.
All as per item No. 16 above, but of size 32mm external dia.
Supply & fixing in replacement of rigid non-metallic PVC bends, FRLS grade of size 20mm external dia including all fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., all as per site requirement and as directed of ISI make as approved.
All as per item No. 19 above, but of size 25mm external dia.
All as per item No. 19 above, but of size 32mm external dia.
Supply & fixing Junction boxes with lid and screws of 20mm external dia upto 4 way of ISI make as approved.
All as per item No. 22 above, but of size 25mm external dia
All as per item No. 22 above, but of size 32mm external dia
Taking down of existing unserviceable clamps and S&F new clamps made out of 25x4 mm MS flat bending to shape, drilling holes for bolts suitable for securing of PVC conduit upto 32 mm dia along the pole or wall from Light fitting to junction box, including nuts, bolts, washers and painting with two coats of aluminium paint over a coat of red oxide primer, complete, all as specified and directed.
M&L for earthing complete with GI earth plate 60x60cmx6mm thick electrode and 4mm dia GI wire as earthing lead.burried directly in ground (earth pit not less then 2.25 meters deep below ground level) with top edge of the plate not less then 1.5 meters below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 5 and incl earth work, PCC pit and RCC cover, watering pipe 20 mm dia light grade, funnel, wire mesh, protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire, charcoal dust and salt etc and connected to earthing test point all as specified and as directed including taking down existing earthing.
M&L for earth continuity conductor /main earthing lead fixed to wall/batten or recess/chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanized iron or steel wire complete.
Dismantling of old steel pole / struts any type and size including demolition of concrete, foundation, necessary excavation and earth work and transportation etc.
Supply, install erect in trench vertical position steel tubular seweaged welded poles complete with MS base plate of 6mm thick of size 450mm x 450 mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 9 mtr long 410 SP-31 including drilling of holes of required size and Nos for fixing of cross arms bracing support/ taking out of cables etc and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminous paint for the portion embedded in concrete complete all as specified and as directed. Make: National Tubing Co./Calcutta Tubing Co/Jindal
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for pole / struts foundation etc all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate for pole /struts foundation etc all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm graded aggregate for coping including necessary form work and fair finishing of exposed surface of concrete all as specified and directed.
Excavation in trenches in soft / loose soil n.exc 1.5 mtr wide n.exc 1.5 mtr deep getting out soil complete all as specified and directed.
Returning filling in including spreading leveling well ramming in layers n.exc 25 cm thick in a layers all as specified and as directed.
Removing excavated material (Soil) n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed.
Boring of road for laying of pipe not exceeding 90 cm below ground level all complete as specified and as directed.
Taking up or down GI water tubing/PR-R pipe 100 mm dia including fitting connections and cleaning tubing, fitting/ cutting threading of serviceable tubing for relaying and removal of unserviceable tubing all as directed by Engr-In- Charge.
All as per item No. 73 above, but for 80 mm dia.
All as per item No. 73 above, but for 50 mm dia.
All as per item No. 73 above, but for 40 mm dia.
All as per item No. 73 above, but for 25 mm dia.
All as per item No. 73 above, but for 20 mm dia.
All as per item No. 73 above, but for 15 mm dia.
Re-fixing only old serviceable GI pipe incl fittings and connection in new or old position of 100 mm dia.
All as per item No. 80 above, but for 80 mm dia.
All as per item No. 80 above, but for 50 mm dia.
All as per item No. 80 above, but for 40 mm dia.
All as per item No. 80 above, but for 25 mm dia.
All as per item No. 80 above, but for 20 mm dia.
All as per item No. 80 above, but for 15 mm dia.
Supply and laying the GI water tubing medium grade with all fittings in trenches all as directed 100 mm dia.
All as per item No. 87 above, but for 80 mm dia.
All as per item No. 87 above, but for 50 mm dia.
All as per item No. 87 above, but for 40 mm dia.
All as per item No. 87 above, but for 25 mm dia.
All as per item No. 87 above, but for 20 mm dia.
Supply and laying the GI water tubing medium grade with all fittings for fixing to wall or laid in floor / ground all as directed 15 mm dia.
Supply and laying/ fixing polypropylene random pipe (PP-R) PN 16 in three layer incl fixing of all fittings made out of PP–R as required for fixing all fittings in trenches complete all as specified and directed for 110 mm bore. Make – SFMC/PRINCE/RELIANCE/SAVOIR-FAIR.
All as per item No. 94 above, but 90 mm dia.
All as per item No. 94 above, but 63 mm dia.
All as per item No. 94 above, but 50 mm dia.
All as per item No. 94 above, but 32 mm dia.
All as per item No. 94 above, but 25 mm dia.
Supply and laying/ fixing polyprolene random pipe (PP-R) PN 16 in three layer incl fixing of all fittings made out of PP–R as required for fixing to wall or laid in floor / ground all as specified and directed for 20 mm bore. Make – SFMC/PRINCE/RELIANCE/SAVOIR-FAIR.
M&L for attending pipeline breakdown of CI pipe of 80 mm dia by making lead joint with lead and spun yarn and moulding clay including taking up/down pipe using chain pulley or rope and excavation in any type of soil including returning filling and removal of soil and testing of pipe line complete all as specified and directed.
All as per item No. 101 above, but 100 mm dia.
All as per item No. 101 above, but 150 mm dia.
All as per item No. 101 above, but 200 mm dia.
M&L for attending pipeline breakdown of DI pipe of 80 mm dia by making rubber tyton joint with rubber seal gasket joint including taking up/down DI pipe using tripod and chain pulley or rope and excavation in any type of soil including returning filling and removal of soil and testing of pipe line complete all as specified and directed.
All as per item No. 105 above, but 100 mm dia.
All as per item No. 105 above, but 150 mm dia.
All as per item No. 105 above, but 200 mm dia.
S&F in repair Gun metal gate valve (screwed) with iron wheel head, screwed both ends for iron / PPR pipe of size 50 mm dia.
All as per item No. 109 above, but 40 mm.
All as per item No. 109 above, but 25 mm.
All as per item No. 109 above, but 20 mm.
All as per item No. 109 above, but 15 mm.
M&L for Construction of valve pit of size 120x 120 x 120 cm (Internal dimension) incl necessary earth work and MS sheet 2 mm thick cover with angleiron frame 40 x 40x 6mm including dismantling of valve pit with cover all as specified and directed.
All as per item No. 114 above, but of size 90 x 90 x 90 cm.
M&L for repairs to GI pipe line by cutting the damaged portion, threading both sides, insertion of same bore GI long screw, testing for leak proof in position all as directed. Note: Excavation & earthwork shall be measured separately.
Taking down old unserviceable sluice valve from existing position and supply and fixing cast iron sluice valve conforming to IS - 14846 clockwise dosing with flanged ends and iron wheel including necessary joints by means of bolts, nuts washers and rubber gaskets complete all as specified for 100 mm bore pipe.
All as per item No. 117 above, but 150 mm dia.
S&F ballcock or float valves high pressure of synthetic metal with epoxy aluminium rod and high density plastic ball screwed with GI socket for iron pipe of size 25 MM dia.
All as per item No. 119 above, but 20 mm dia.
M&L for Cast iron Bends (any type, radius and angle) size up to 200 mm bore, tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (flange sockets or socket and spigot) collars, caps and plugs all complete all as specified and as directed.
Drilling and tapping of CI water line 15 mm to 20 mm for branch connection complete all as specified and as directed.
Taking down old unserviceable non return valve form existing position and supply and fixing cast iron non return valve conforming to IS - 5312, PN-1.6 including necessary joints by means of bolts, nuts washers and rubber gaskets complete all as specified for 150 mm bore of pipe.
All as per item No. 123 above, but 100 mm dia.
S&F air release valve double action chamber to conforming IS-14845 of size 150 mm bore complete all as specified and directed.
Supply and fixing male threaded socket complete suitable for 32 mm bore all complete as specified and as described.
All as per item No. 126 above, but 25 mm.
All as per item No. 126 above, but 20 mm.
Taking down cement plaster from wall including racking out joints hacking for key and scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15mm thick cement plaster in cement mortar 1:6 in mixed with water proofing compound all as per manufacturer’s instructions, finished even and fair without using extra cement complete all as specified and as directed. (Note:- Water proofing compound shall be measured and paid separately as “supply only”).
Supply only water proofing compound ISI marked.
Complete removal of existing treatment from AC sheet roofing Galvalume sheet, RCC sheet etc preparation of surfaces and Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including necessary scaffolding in different for camouflage and concealment of sigma II software design / patterns approved by userscomplete all as specified and as directed.
All as per item No. 132 above, but Preparation / apply to new surface.
M&L for preparation and cleaning of old steel CGI surfaces (using emery paper/ sand paper for old rusted surface) exec 10cm width or girth in roof/cladding etc and applying two coats of synthetic enamel paint over a coat of red oxide primer in different tint for camouflage and concealment of sigma II software design/patterns approved by users all as specified and directed.
Re-writing letters or figures (Block, Romans, Italic, or Indian) not exc. 30 cm height & average height 15 cm with thick synthetic enamel paint complete all as specified and as directed.
Demolition of (Un reinforced) Cement Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in sub base etc complete all as specified and as directed.
M&L for designed, pre polished chequered cement concrete tiles 25mm thick with grey cement and pigments set, jointed & pointed in neat cement slurry, laid over 20mm thick screed bed in CM 1:6 finished with pigments match the shade of tiles complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) 75mm thick as in plinth protection/ path/ paving laid in panels, finishing the top surface even and smooth with out using extra cement complete all as specified and directed.
Forming Contraction (Dummy) joints 50mm deep X 10 mm wide, filled with sealing compound Grade 'A' etc complete all as specified and as directed.
M&L for sand cushioning to receive interlocking tiles incl spreading, leveling in layers complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade With Grey Cement and pigment complete all as specified and directed.
Demolition of cement concrete of any description and in any position etc complete all as specified and as directed.
M&L for Cement concrete (1:2:4) type B1 using 20mm graded aggregate as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement complete all as specified and directed..
M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping, kerbs etc complete all as specified and as directed.
Demolition of brick work/ stone masonry built in cement mortar including arches, pillars etc and excluding precast concrete article all as specified and as directed.
M&L for Brickwork with subclass ‘B’ old size bricks, straight or curved on plan exec 6m mean radius built in 1:4 complete all as specified and as directed.
All as per item No. 148 above, but except bricks.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in built in cement mortar 1:4 complete all as specified and as directed.
Taking down cement plaster from brick or concrete or stone walls including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15 mm thick cement plaster in CM (1:4) on fair faces of brick wall or concrete surfaces and finishing the surface even and smooth (without using extra cement complete all as specified and as directed.
M&L 15mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finish even and fair complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying two coat of cement based paint over a coat of alkali resistant primer complete all as specified and as directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for etc complete all as specified and as directed.
M&L for precast cement concrete (1:2:4) type B-1 (20mm graded aggregate) in cover slab for drain and placing in position etc complete all as specified and as directed.
M&L for Mild steel bars (TMT bars) 10mm dia and over cut to length, bent to shape required including cranking bending, spirally for hoping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia, complete all as specified and directed.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc., required for complete and proper execution of the work. Refer Schedule A notes for details.
M/S Banerjee construction co
M/S R. K. INDUSTRIES
SREE SWAPAN KUMAR GHOSH
M/S Vaishno Constructions
SHRI P P SHARMA
M/S P K ROY AND CO
M/S LAKPA LAMA
M/S MANAS MITRA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .