Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 CrAccepted-AOC | ₹1.2 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹1.2 Cr+₹8.1 L (6.90%)Rejected-AOC | ₹1.2 Cr+₹8.1 L (6.90%) | 2 | Rejected-AOC L2 |
| 3 | 3₹1.4 Cr+₹20.6 L (17.6%)Rejected-AOC | ₹1.4 Cr+₹20.6 L (17.6%) | 3 | Rejected-AOC L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical REFER TO TECHNICAL EVALUATION REPORT |
| 5 | Rejected-Technical | - | - | Rejected-Technical REFER TO TECHNICAL EVALUATION REPORT |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
27 Aug 2020, 12:00 pmClosed
CGM(OM)
1st Floor, AEGCL, Bijulee Bhawan, Paltan Bazar ,Ghy-01
Turnkey Construction of 132KV and 33kV Transformer bay, 33 KV tween Bus, Cable trench and transformer Pad at 220 KV Namrup GSS, AEGCL along with associated Civil Works
2020_AEGCL_18168_1
MD/CGM/NAMRUPBAY/01
Open Tender
Composite Works
Turn-key
300 days
NAMRUP GSS
Refer to BID
2 documents required · 2 mandatory
₹5,000
AEGCL
₹2.8 L
HQ AEGCL
2 Jan 2021
22 Jul 2020
31 Aug 2020
22 Jul 2020
27 Aug 2020
22 Jul 2020
10 Aug 2020
Amount
Supply Part (132kV)
132 KV Tandem Isolator without E/S (motorized)
132 KV Isolator without E/S (motorized)
132 kV Post insulator
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied.
132 KV Transformer CT mounting structure, foundation bolts etc with all terminals connectors
132 KV Tandem Isolator without E/S (motorized)
132 KV Isolator Without Earth Switch (motoized)
132 kV Lightning Arrester
132 kV Post insulator
Power & Control Cables
Power Cables of 2C, 6 mm2
Power Cables of 4C, 16 mm2
Control Cables of 4C, 2.5 mm2
Supply of Earthing System Materials
50x6 GI flat Earthing conductor for earthing of indoor L.T & control panels, Junction box Marshalling boxes, cable trenches etc.
40 mm Dia. 3mtr long M.S. pipe earth electrode (driven) with test link for each tower with treated earth pits, LAs
65x12 GI flat for risers, equipment earthing, column earthing etc.
ACSR Zebra
Disc Insulator String complete with all hardware, fittings, clamps etc. [Panther Conductor]
10 Disc Tension Insulator String
9 Disc Suspension Insulator String
Clamps and Connectors
PG clamp for zebra
T clamps with connector for Zebra to Zebra
33kV Supply Part
33 KV polymeric post Insulator
36 KV Isolator (motorized) without Earth Switch with all fittings and accessories
Supply of new lattice galvanized steel structure for mounting of 36 KV Isolator (motorized) without E/S
Supply of new lattice galvanized steel structure for mounting of 33 KV LA
Supply of new lattice galvanized steel structure for mounting of 33 KV PT
Supply of new lattice galvanized steel structure for mounting of 33 KV CT
Supply of bay steel structure except mounting structure
Columns
Column Type 'C5'
Column Type 'C7'
Beams
Beam Type 'B6'
Beam Type 'B5'
ACSR Zebra conductor (for twin Bus)
Supply of earthing system materials
Main Earth Mat (65X12 mm GI flat)
65X12 GI flat earth for riser, equipments earthing.
50X6 GI flat earthing conductor for earthing of indoor LT & control panels, junction box, marselling boxes, cable trench etc.
40 mm Dia 3 mtr long M.S rod earth electrode with test link for each other equipments in treated earth pit.
T- Clamp Zebra to Zebra
UPG Clamp for Zebra
Disc Insulator 70 KN
Hardware fiting dead end clamp complete with yoke plate, cross arm etc. for twin zebra conductor
Suspension clamp envelope type for twin zebra conductor with complete fittings
Description of Work / Item(s)
Amount
Construction of Foundation including supply of foundation materials all as per drawing including Erection, testing & commissioning of equipment with mounting structures with laying & terminating of LT power and control cables as required
Circuit Breakers 132 kV Gang operated Sf6 Breakers
Current Transformers (132 kV, 600-300/1-1-1 Line CT)
132 kV Without Single E/S (motorized)
132 kV Tandem Isolator without E/S (motorized)
Lightning Arrester (132 kV Lightning Arrester)
Post Insulator (132 kV Post insulator)
132kV IVT
Foundation, Erection, Testing & Commissioning of following 33 KV bay equipments with mounting structures (where ever required) including making jumpering, earthing and laying marking & terminating of LT power and control cable at ends from equipments to relay control panel or elsewhere as required.
33 KV Gang operated SF6 Breaker
33 KV Isolator without E/S (motorized)
33 KV Lighting Arrestor
33 KV Post Insulator
250 KVA,33/0.433 KV 3ph Station Service Transformer alongwith construction of foundation on new RCC mounting pedestal
33 KV Transformer CT
Foundation, Erection of following 33 KV equipments on existing mounting structures by retrofitting, including supply of all materials required for retrofitting and cost of dismantling of following equipments.
33 KV Circuit breaker
33 KV Isolator (motorized) without Earth switch
33 KV Lightining Arrester
33 KV Current Transformer
Construction of foundation for lattice steel columns including supply of all foundation materials and erection of the same
Column Type 'C5'
Column Type 'C7'
Erection of switchyard steel structure (beams)
Beam Type 'B6'
Beam Type 'B5'
Hoisting of insulator string, stringing of conductors & GI shield wire including supply of Clamps, GI stranded shield wire , connector etc, if not mentioned otherwise.
Installation of earthing system with GI flats, electrodes in treated earth pit etc.
Construction of Transformer Pad as per drawing
Construction of Cable Trench C-Type
GANAPATI ENTERPRISE
Assam Electricals
GANAPATI ENTERPRISE
Shiv Construction
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .