Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹15.7 L+₹1.9 L (13.6%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹17.4 L+₹3.6 L (25.6%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹17.9 L+₹4.0 L (28.9%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
13 Jul 2020, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
SPECIAL REPAIR TO OR MD ACCN BLDG NO P-72 AT LALGARH JATTAN MIL STN
2020_MES_349803_2
8931-11/20-21
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
Class E cat (a) (i) (b)(i)
8 documents required · 8 mandatory
₹500
Yes
GE Lalgarh Jattan
₹28,000
Yes
29 Aug 2020
20 Jun 2020
16 Jul 2020
20 Jun 2020
13 Jul 2020
27 Jun 2020
Amount
B/R Portion Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) complete all as specified and as directed by Engineer in Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificlly provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by Engineer in Charge.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed by Engineer in Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and as directed by Engineer in Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed by Engineer in Charge.
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed by Engineer in Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and as directed by Engineer in Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and as directed by Engineer in Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and as directed by Engineer in Charge.
M&L for glazed ceramic coloured tiles of size 350 X 250 X 7 mm / 450 x 350 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer in Charge.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and as directed by Engineer in Charge.
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and as directed by Engineer in Charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engineer in Charge.
M&L for 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub-base complete all as specified and as directed by Engineer in Charge.
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in kerb stones size 300mm x 300mm x 100mm with plain fair faces, including chamfers, weathering, throating etc setting in CM 1:4 complete all as specified and as directed by Engineer in Charge.
M&L Machined pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over 50mm thick Fazilka sand cushion complete all as specified and as directed by Engineer in Charge.
Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-charge
M&L for reinforced cement concrete 1:1.5:3 type A-1 using 20mm graded stone aggregrate in Chajjas complete all as specified and as directed by Engineer in Charge. Note : Reinforcement shall be measured and paid seperately.
S&F mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed by Engineer in Charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge.
M&L for rendering, 10 mm thick on brick work or concrete surfaces in cement mortar 1:4 on ceiling finished even and fair complete all as specified and as directed by Engineer in Charge.
M&L for two coats of oil bound distemper on newly plastered surfaces of walls paint over 3mm thick wall care putty including preparation of surfaces complete all as specified and as directed by Engineer in Charge.
M&L for 3 coats of white wash on newly / old plastered surfaces incl preparation etc. complete all as specified and as directed by Engineer in Charge.
M&L for two coats of cement base paint on newly / old plastered surfaces incl preparation etc. complete all as specified and as directed by Engineer in Charge.
M&L for broken brick boulder hard core of gauge, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer in Charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed by Engineer in Charge.
M&L continous brick edging; with fly ash bricks old size bricks, with width equal to the width of the brick; liad dry on end vertically complete all as specified and as directed by Engineer in Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. and getting out hard/dense soil complete all as specified and as directed by Engineer in Charge.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation, filling & mass concrete complete all as specified and as directed by Engineer in Charge.
M&L for brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by Engineer in Charge.
M&L for brick work with fly ash bricks, old size bricks straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and as directed by Engineer in Charge.
M&L for PCC 1:2:4 type B2 using 40mm graded aggregates as in benching / haunchig of manholes including forming channels including necessary formwork etc complete all as specified and as directed by Engineer in Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded aggregates as in coping and the like including weatjeromg.slightly rounded or chamfered angles and throating, as directed including necessary formwork etc. complete all as specified and as directed by Engineer in Charge.
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and as directed by Engineer in Charge.
M&L Rendering 10mm thick on fair face of brick work in cement mortar 1:4 and finished surfaces even and smooth with using extra cement as specified including WPC complete all as specified and as directed by Engineer in Charge. Note : - (WPC shall be measured and paid seperately)
M&L moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed by Engineer in Charge.
Supply and laying DWCPE (SN8) drain pipes 150mm inner dia as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all assessories / fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge. Make :- Rex Polyextrusion Limited/ Dura line / Alom Poly Extrusions Ltd / Jain Irrigation
Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm any type of soil complete all as specified and as directed by Engineer in Charge.
Removing excavated material n.exc 50m and depositing where direcrted at a level n.exc 1.50 m above the starting point complete all as specified and as directed by Engineer in Charge.
Cutting into existing manholes for connection of new drain making pipes and rendering cutting out existing benching & forming branch channel in PCC 1:2:4 type B1 smooth finished & forming benches as reqd etc for 150 mm bore complete all as specified and as directed by Engineer in Charge.
M&L preparation of new steel surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer in Charge.
Dismantling of brick tiles in floor laid dry and pointed in cement morter complete all as specified and as directed by Engineer in Charge.
Demolition mud in roofs, any thickness, including plastering and leeping complete all as specified and as directed by Engineer in Charge.
M&L PCC (1:7:12) using 40mm graded stone aggregate as filling of sunken floors/bottom and side of drain complete all as specified & directed by Engr-in-charge.
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 and finished fair and even including mixing of WPC in mortar complete all as directed by Engr-in-charge.
Supply only integrated water proofing compound complete all as directed by Engr-in-charge. Make:- Dr Fixit/Fosroc/BASF/STP
M&L for creating fillet caving 50x50mm with polymer modified mortar on the junction of slab and wall as per manufacture instructions, Material and labour Providing for applying two coats of two component (1 part Liquid: 2 part Powder) ready to use cementitious waterproof coating on properly prepared surface by brush having elongation of >50% for the applying water proofing treatment as per following and complete all as directed by the EIC. (i) Applying 1st coat of two components modified polymer coating on horizontal and verticle surfaces. (ii) Provn of glasses fiber mess of 2x2mm immediately on alone coating. (iii) Applying 2nd coat of two components modified polymer coating after 72hrs on horizontal and verticle surfaces. NOTE:- Before execution applicator must get appoved by EIC, Complete treatment to be carried out by authorised applicatior of waterproofing manufacture. Make : Dr Fixit/Fosroc/BASF/STP
M&L applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm as in roof including cleaning surfaces all as specified and directed by Engr in charge.
M & L Lime concrete terracing as specified in roof (excluding bitumen tack coat) complete all as specified and directed by Engr-in-Charge.
M&L 40mm thick brick tiles laid flat on lime concrete & joints grouted flush in cement mortar (1:3) bedded in 15mm th cement morter (1:6) mixed with 5% of crude oil by weight of cement on lime concrete complete all as specified and directed by Engr-in-Charge.
,---ditto-- all as per above item No 51 above but except tilescomplete all as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work etc complete all as specified & directed by Engr-in-Charge.
M&L racking out joints/pointing to brick work or brick tiles laid flat in wall to bricks on edges in floors, surface channels, roofs etc. and keyed pointing to bricks walls in CM 1:4 all as specified and directed.
Taking down chowkhats or frames n.exc 1.5 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engr-in-Charge.
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engr-in-Charge.
Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed by Engr-in-Charge.
S&F framed work as in chowkats of doors windows of angle iron, gates or other section with gusset plates, rails, braces etc conforming to Gde Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S&F hold fast of flat iron 25 x 3 mm conforming to Fe-290 or Fe 330 including preparing the surfaces & treated with two coats for coaltar & sanded with clean sharp sand complete all as specified and directed by Engr-in-Charge.
M&L for Cement concrete 1:3:6 type C–1 (using 20mm graded crushed stone aggregate) as in coping, hold fast, bed blocks or similar block etc complete all as specified and directed by Engr-in-Charge.
Providing CASEMENT UPVC WINDOW/vent fabricated by approved manufacturer in diferent size of wall thickness 1.2mm + .25 made out of extruded section plain UPVC sections, The window/vent frame made out of Rigid UPVC sections meter cut at 4 Corners & joint with plastic fution welding with internal reinforce require. The Shutter section made out of extruded Rigid UPVC with internal reinforced with provision of 5 MM glaze wire mesh aas per requirement. The Window shall be fixed to the wall using 65 x 100 MM long MS fasterners at suitable place provided for each vertical and horizontal member etc. complete as per manufacturere's specification and direction of Engineer-in-Charge. Make : Rajshri products, H2O SOLUTION, MADHU INDUSTRIES, FENESTA
S&F 100 mm long butt hinge, extruded aluminium alloy with galvanised mild steel hinge pin, anosied and fixed type B-21 complete all as specified and as directed by Engineer-in- charge.
S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections complete all as specified and as directed by Engineer-in- charge.
S&F 150 mm long aluminium anodised handle, cast type complete all as specified and as directed by Engineer-in- charge.
Taking down existing shutter and refixing in same opening shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each complete all as specified and as directed by Engineer-in- charge. (Note:- 'Refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.)
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as directed.
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and as directed by Engineer-in- charge.
S&F flush shutter 25mm thick solid core construction with block board core and plywood face panels commercial type on both sides as cupboard and kitchen shutters complete all as specified & directed by Engineer-in- charge.
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel complete all as specified & directed by Engineer-in- charge.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four bolt on plate and two on staple plate complete all as specified & directed by Engineer-in- charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt, dia not less than 16 mm complete all as specified & directed by Engineer-in- charge.
S&F in repairs 300mm ordinary rat tail rod pattern springs including roller and roller plate mild steel complete all as specified and directed by Engr-in-Charge.
M&L Block board, 19/20mm thick, grade 1st quality, exterior grade, decorative type with decorative face veneer on both face, fixed with screws to timber frame work complete all as specified and directed by Engr-in-Charge.
M&L plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc 3 & n.exc 6 Sq.cm of 2nd class hard wood complete all as specified and directed by Engr-in-Charge.
S&F continous (piano) hinges, mild steel, bright finish or electro galvanised (width of flaps 30mm) complete all as specified and directed by Engr-in-Charge.
S&F 125mm hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engr-in-Charge.
S&F 125 mm long aluminium anodised handle, cast type complete all as specified and directed by Engr-in-Charge.
S&F stainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge.
,---ditto-- all as per item No 80 above but fixed in repairs complete all as specified and directed by Engr-in-Charge.
S&F 5mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified & directed by Engineer-in- charge.
S&F 5mm thick sheet glass ordinary quality and glazing with oil putty in squares exc. 0.5 Sqm in each pane complete all as specified & directed by Engineer-in- charge.
M&L 12 mm thick Pre-laminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed by Engr-in-Charge.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by Engr-in-Charge.
M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engr-in-Charge.
M&L preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
S&F drapery rods, coloured, standrad quality, powder coated not less than 25mm dia with heads at both ends and middle support, rings, etc. complete all as specified and directed by Engr-in-Charge.
S&F in repair brass hat pegs, solid body, 125 mm to 175 mm (4 legs) complete all as specified and directed by Engr-in-Charge.
S&F in repair towel rails 20mm dia 600mm long brass chromium plated superior quality fancy type complete all as specified and directed by Engr-in-Charge.
S&F in repair vitrieous china wash down WC (Pedestal pattern) white and flush piple including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. complete all as specified and directed by Engr-in-Charge.
S&F in repair plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, seat and cover for water closet (European type) complete all as specified and directed by Engr-in-Charge.
S&F in repairs PVC valve less, syphonic action type flushing cistern, 10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe and connection to pipe and flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern complete all as specified and directed by Engr-in-Charge.
S&F in repair wash basin Size 600 x 480 mm with angle back, including angle iron brackets and stainless steel coupling and waste pipe complete all as specified and directed by Engineer-in-Charge. Note : colour shall be decided by Engr-in-Charge.
S&F in repairs pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm borecomplete all as specified and directed by Engr-in-Charge. Note : Wt should not be less than 450 gms
S&F in repair bib tap, 15mm bore cast copper alloy chromium plated, long body, fancy type with capston head and cup screwed down, hand operated, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in-Charge.
S&F in repair CP brass stop valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup complete all as specified and directed by Engr-in-Charge.
S&F in repair CP brass stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) fixed complete all as specified and directed by Engr-in-Charge. Make : Jaquar cat No- 7053 or equivalent in Marc/Plumber.
S&F in repair, 15 mm bore shower rose, 125 mm size, brass chromium plated with sweivel joint complete all as specified and directed by Engr-in-Charge.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engr-in-Charge.
Dismantling of water tanks of capacity exc 500 and n.exc 1000 ltrs and removing from site complete all as specified and directed by Engr-in-Charge.
S&F rotational moulded polythene water storage tank 500 ltr capacity of ISI marked vertical with closed top hoisted and fixed in position all as specified in SSR part-I, complete all as specified and directed by Engr-in-Charge.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed in repair all as specified and as approved by GE/Engineer-in-Charge.
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe complete all as specified and directed by Engr-in-Charge.
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe all as directed.
,--ditto-- all as per item No 106 above but 20mm dia pipe complete all as specified and directed by Engr-in-Charge.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engr-in-Charge.
,---ditto--- all as per item No 108 above but 20mm dia pipe complete all as specified and directed by Engr-in-Charge.
Dismantling of cast iron pipes, jointed in cement mortar and tabing out of trenches if required upto 100mm dia complete all as specified and as directed by engineer-in-Charge.
Dismantling of cast iron pipes, jointed in cement mortar and tabing out of trenches if required 75mm dia complete all as specified and as directed by engineer-in-Charge.
S&F 100 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints as specified & directed by Engineer-in-charge.
S&F 75 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints as specified & directed by Engineer-in-charge.
Fixing only 100 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints as specified & directed by Engineer-in-charge.
Fixing only 75 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints as specified & directed by Engineer-in-charge.
M&L in repairs 75mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
S&F in repairs branch pieces single (equal or unequal) ordinary or inverted (spring or socket type) or with paralled branch 100mm dia but with oval access door.
S&F in repairs branch pieces single (equal or unequal) ordinary or inverted (spring or socket type) or with paralled branch 75mm dia but with oval access door.
S&F in repairs 75mm cast iron sanitary connections-short connections pipe of length upto 300mm with socket fixed complete all as specified and directed by Engr-in-Charge.
S&F in repairs 100 mm cast iron sanitary connections-short connections pipe of length upto 300mm with socket fixed complete all as specified and directed by Engr-in-Charge.
S&F in repairs 75mm bore cast iron bends (any radius) dimining pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and directed by Engineer-in-Charge
S&F in repairs 100mm bore cast iron bends (any radius) dimining pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and directed by Engr-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc. including cleaning or refixing or removal to Store (measured overalll as fixed along the cente line over fittings and accessories) complete all as specified and directed by Engr-in-Charge.
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engr-in-Charge.
S&F 110 mm dia PVC (SWR) bend any radius complete all as specified and directed by Engr-in-Charge.
S&F in repairs 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed to walls, ceilings or in floors complete all as specified and directed by Engr-in-Charge.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed by Engr-in-Charge.
E/M Portion Taking down carefully copper/aluminium point wiring (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately), and making good disturbed surfaces of walls, floors etc to match with existing surfaces complete all as specified and directed by Engr-in-Charge.
Taking down MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engr-in-Charge.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engr-in-Charge.
M&L for concealed Point wiring with two single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick hylam sheet top cover of required size for mounting switches, sockets for one Light point controlled by one, one way switch etc complete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour complete all as specified and directed by Engr-in-Charge.
,---ditto--- all as per serial iem No. 131 above one ceiling/exhaust fan point controlled by one switch and regulator complete all as specified and directed by Engr-in-Charge.
,--ditto-- all as per serial item No. 131 above but for one bell/buzzer point controlled by one bell push complete all as specified and directed by Engr-in-Charge.
,--ditto-- all as per serial item No. 131 above but for one 3 pin switch socket outlet, 5 Amp on the same board with other switches complete all as specified and directed by Engr-in-Charge.
,--ditto-- all as per serial item No. 131 above but for ne 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed by Engr-in-Charge.
,--ditto-- all as per serial item No. 131 above but for Two way point controlled by two way switch complete all as specified and directed by Engr-in-Charge.
,--ditto-- all as per serial item No. 131 above but wiring with 4 sq.mm multistranded cable and earth wire with copper conductor of size 4 sq.mm for 15 amps power point complete all as specified and directed by Engr-in-Charge.
S&F piano switch flush button single pole one way 5 Amps complete all as specified and directed by Engr-in-Charge.
S&F piano socket 2 in 1, 2/3 pin 6 amp flush type 250 volts AC complete all as specified and directed by Engr-in-Charge.
S&F piano socket 2 in 1, 3 pin 5 amp and 15 amp flush type 240 volts AC complete all as specified and directed by Engr-in-Charge.
S&F piano switch 15 amp flush type 240 volts AC complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush button single pole two way 6 Amps complete all as specified and directed by Engr-in-Charge.
S & F LED light fitting 1 x 20 W, 230 V integral sleek polycarbonate LED Channel with white acrylic cover incl making connection complete all as specified and directed by Engr-in-Charge. Make : Bajaj, Model: BCLSB20WH or equivalent model of Crompton Greaves/ havells.
S&F lamp holder insulated body with back plate for angle/batten fitting with LED lamp of 09 watt, 230V, AC complete all as specified and directed by Engr-in-Charge.
S&F piano bell push flush type 6 Amp complete all as specified and directed by Engr-in-Charge.
S&F bell AC 230 volt single pole complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose surface bakelite two to three terminals/plate 5 amps complete all as specified and directed by Engr-in-Charge.
S&F fan regulator electronic solid state with steps suitable for 1200/1400mm sweep ceiling fan working on 230 volt AC complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbar flush/surface mounting double door wth IP 43 class insulation including wooden board complete all as specified and directed by Engr-in-Charge. Make: L&T/Havells/Legrand
Supply and fix MCB single pole 240 volt 6-32 amps 10 KA, 'B' curve complete all as specified and directed by Engr-in-Charge. Make: L&T/Havells/Legrand
Supply and fix MCB SPN 240 volt 40 amp 10 KA, 'B' curve complete all as specified and directed by Engr-in-Charge.Make: L&T/Havells/Legrand
Supply and fixing PVC Blanking Plates one way with internal lock complete all as specified and directed by Engr-in-Charge.
S & F LED building security light fitting 25 watt with epoxy powder coated sheet aluminium housing, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover and accessories complete incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer after taking down old u/s one complete all as specified and directed by Engr-in-Charge. Make of fitting Bajaj Cat Pt No BRLEP 25 W LED or equivallent in Crompton/Havells.
M&L for Sub Main Wiring with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge. NOTE-two run of 6 sq.mm & One run of 6 sq.mm & One run of PVC conduit with accessories shall be measured as One length.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position.
S&F sheat metal incl single pole and neutal with 02 Pin and earth plug and socket complete with 01 single pole 20 Amps 240volts, MCB complete incl necessary fixing arrangement and all incoming and outgoing electric connection complete all as specified and directed by Engr-in-Charge.
M&L for taking Exhaust fan 300 mm sweep single phase 240 volt 50 Hz and refixing the same incl all electrical connection, fastners of required size complete all as specified and directed by Engr-in-Charge.
Fixing only exhaust fan 300 mm sweep complete after complete servicing and painting and connecting up including provision of cable from ceiling rose/connector to fan, new nut, bolts, fasteners and wire mess framed in wood batton outside the bldg as louvers. complete all as specified and directed by the Engr-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by Engr-in-Charge.
Supply and fix factory made, sheet distribution boards,double door, protection class IP-43 suitable for mounting MCB/Isolator, with min 200 Amps, copper bus bar, working on 440 V AC of TP & N 4 Ways, complete all as specified and directed by Engr-in-Charge. Make: L&T/Havells/Legrand
S&F in DBs (catered above) MCB isolator 4 pole 100 Amps complete all as specified and directed by Engr-in-Charge. Make: L&T/Havells/Legrand.
Note:- (i) BOQ item No 149 to 151,160 & 161:- The distribution board and MCB shall be of same make. (ii) The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
PAREEK AND COMPANY
ram rattan dass aggarwal
GOYAL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .