Loading…
Loading…
Tender Value
₹59.7 L
EMD Value
₹1.2 L
Closing Date
24 Jun 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less ; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any Signalling work involving trenching, cable laying, termination and outdoor wiring. Note 1: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/ 40 / 60% (as the case may be) criteria of similar nature of work.
22 conditions · 12 needing a document upload
PAN card Copy should be enclosed.
Please submit the copy of the registration certificate as applicable, GSTIN certificate should be enclosed.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Firm has to submit authorization letter for uploading documents on IREPS in case he/she is not an authorized person.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc.Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc. are not allowed.
Copy of PAN number and GSTIN number should be submitted.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void.
(i)Tenderers will examine various provisions of the Central Goods and Service Tax Act, 2017(CGST)/Integrated Goods and Service Tax Act,2017(IGST)/Union Territory Goods and Service Tax Act,2017(UTGST)/respective states State Goods and Service Tax Act(SGST) also, as notified by Central/States Govt. and as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit(ITC) likely to be availed by them is duly considered while quoting rates. (ii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iii) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism(RCM) and deposit the same to the concerned authority.
Tenderer should go through Annexure 1 & 2 of Tender Notice (attached in Tender Document)for list of documents required to be uploaded along with the offer.
S&T work i.c.w Provision of RUB in lieu of trespass location at Km 1075.391 (closed LC no 182/C) between SFH-ML stations on Lucknow-Ayodhya Cantt Section & Provision of RUB at KM.1071.404 near ROB no.789A (Sadar ROB) between LBH & LKO stations on UTR-LKO section & Rebuilding of ORN-3 bridges (Total 23 nos. bridges) in the jurisdiction of ADEN/II-SLN under Sr. DEN-IV/LKO of Lucknow Division of Northern Railways.
106-Sig-Tender-14-2026-27
106-Sig-Tender-14-2026-27
Open
Works - General
270 Days
Lucknow, Uttar Pradesh
₹0
₹1.2 L
24 Jun 2026
3 Jun 2026
10 Jun 2026
93 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 59,70,033.52 | ||
| — | 3600.00 | — | — | ||
| Excavating and refilling of trench to the level of ground with rammed earth asper Drg. No.(NR/S&T/Con/1.1/97A) so as not to form a drain 0.3 Mtrs wide & 1mtr deep on both side of the station along side the track. It shall confirm to the safe distance as per signalling and cable plan in all type of soil, it also includes clearence of roots of trees and bushes. | — | — | — | 1,59,336 | |
| — | 23600.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per attached guidelines (Drg. No.(NR/S&T/Con/1.1/97A) or latest on signalling cable laying and as per cable route plan approved by Railways through trenches, RCC pipe, DWC pipe, GI pipe etc and meggering of cable before and after its laying of all type of outdoor cables. Contractor have to transport cable from any store of LKO division to site carefully. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to Railways, as per instructions by Consignee. | — | — | — | 1,28,384 | |
| — | 28800.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/Con./1.1/97A) or latest and as per instruction of the site Engineer. | — | — | — | 1,67,904 | |
| — | 100.00 | — | — | ||
| Boring and trenchless cabling along with supply and insertion of HDPE/DWC self lubricated pipes as per RDSO Spec no. RDSO/SPN/204/2011 Ver 1.1 or latest of 120mm nominal dia in the bore at the depth of 1.4 meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and as directed by Engineer Incharge by trenchless technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. Inspection-Consignee for Supply of DWC/HDPE pipe. The following required coupling arrangement shouldalso be supplied: 1. Suitable snap fit couplers withrubber O ring, 2. Spacers, 3. Tees. 4. Bend. 5. End Cap(1 no. =6mtr ,Straightpipe). (A) The cost shall include horizontal boring through any intermediate obstruction, either natural or man made or any boundary etc. (B) The rate is inclusive of all the materials equipment and labour required for during trenchless horizontal boring under the railway track. Nothing extra shall be admissible on any account than the rate quoted above. (C) The Pipeis to be laid underrailway track/road /culvert. All necessary arrangement are to be provideand all precautions are to be end is not deviated from the horizontal level line by more than 250mm in horizontal and vertical direction. (D) The rate shall be inclusive of direction and protection of underground utilities encountered during boring. (E) The payment for boring shall be made only when DWC/HDPE pipe are laid in the bore. | — | — | — | 1,39,834 | |
| — | 1150.00 | — | — | ||
| HDD boring and trenchless of 120 mm bore dia without HDPE pipe for laying of Signalling/Telecom/Power cable under Track/Road/Culvert etc. Cable laying is covered separately. | — | — | — | 11,05,276.5 | |
| — | 6500.00 | — | — | ||
| Supply of terminal block M-6 (ARA terminals) Block 25 mm centre small M-6 terminal made of PBT as per IRS spec. No.IRS-S-75/2006 (Rev.2) or latest & IRS drawing No.SA-23741/A (Alt. 4) or latest. Inspection: RDSO. | — | — | — | 4,28,350 | |
| — | 3250.00 | — | — | ||
| Termination of all the cores of all type of outdoor cables after its laying on both end.This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also includes dressing and lacing of cables on both ends. Proforma for testing and material for lacing to be supplied by the contractor. | — | — | — | 36,530 | |
| — | 22.00 | — | — | ||
| Supply of Apparatus case steel Single with 'E' type locks and key ward No 42 complete as per drawing No.RE/S&T/ALD/SK/219/82 & 221/82 or latest. Handle should be at the rate of one each 4 nos. appratus case. Inspection : Consignee | — | — | — | 4,14,825.84 | |
| — | 22.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of App. Case single as per Drg. No (NR/S&T/ Con/2.7/97). A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress of water in the base of location box.All material such as cement, sand, aggregate & anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting the cable for termination. | — | — | — | 93,536.3 | |
| — | 22.00 | — | — | ||
| Preparation of App. Case single not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways. | — | — | — | 1,01,394.04 | |
| — | 1.00 | — | — | ||
| Dismantling of lifting barrier/ gate leaves complete set along with winch , wire rope, boom locking arrangements. All dismantelled material to be transported and stacked in the store of DY.CMM/AMV/LKO store depot or SSE/Sig/Inchargers/Store or any other store of northern railway as per consignee. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr.(1 Job= 1 LC). | — | — | — | 3,279.43 | |
| — | 39.00 | — | — | ||
| Supply and installation of earth electrodes as per std.practice. The item includes digging of pitin earth, 3 Mtrs. deepand fixing earth electrode pipe.Casting of cement concrete enclosures as per drg. No.(NR/S&T/CON/6.4/97) or latest. The soil treatment shall be done as per std.practice. The item includes provision of mild steel flat of size35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument,cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipments as per the instruction of Engr. at site & IRSEM. Earth connection Signal & location boxes to be done Drg.No. 19-D6 of IRSEM App II or latest. Complete materials such as earth electrodes as per Drg. No. (NR/S&T/CON/6.3/97)or latest, cement, wiring material, nutbolt for connection & mild steel flat of size minimum 35mm x6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection by - Consignee for supply of earth electrode. (P/Earth pipe= Nos) | — | — | — | 1,26,897.03 | |
| — | 5.00 | — | — | ||
| Supply of Digital insulation Tester (Megger) 100V-1000V DC , Output Voltage-100V, 250V,500V, 1000V DC, Accuracy +- 5% , Resistance Range 200 M Ohm- 2000 M Ohm Accuracy +- 2% Make Motwani , Philips, Rishabh, or similar reputed make. Inspection - Consignee | — | — | — | 36,926.35 | |
| — | 45500.00 | — | — | ||
| Loading, Leading & unloading of materials from store to another store as per instruction of consignee. All the material to be transported carefully without damage. Contractor have to do proper stacking of material and prepare list of material. | — | — | — | 2,47,520 | |
| — | 1.00 | — | — | ||
| Supply of cable fault locator for underground metallic S&T cable of reputed make Dynatel /Andig/Aplab/ Stanley /Tele matrix or similar reputed make specification similar to (Test signal output 1/2 Sine, Pulse width 5nsec to 2500nsec, Max Range:15000m, Filter cut-off Frequency:150kHz (High Pass Filter), Gain:0 to 63dB), RDSO/TEC recommended. Item to be supplied after successful demonstration and approval of railways. Inspection- Consignee | — | — | — | 3,81,999.81 | |
| — | 2.00 | — | — | ||
| Supply of Portable digital auto range multi-meter clamp type Philips, Motwani, Fluke, Rishabh or metravi make capable to measure from (0.1mv/0.01ma) AC/DC upto 0-4/80Amp (AC/DC), upto 600V(AC/DC) and 0.1 ohms- 40M ohms suitable for measurement of Freq., capacitance complete with Manual, leads, battery and holster etc. Clamp meter to be supplied as per instruction of railway engineer. Inspection by-Consignee. | — | — | — | 17,010.98 | |
| — | 15.00 | — | — | ||
| Supply and provision of joints with the help of thermo shrink jointing ( TSF-3) kit as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations for 06 quad/04 Quad cable.Jointing kit to be supplied as per RDSO Specification IRS:TC 77-2012 (Rev-3) or latest amendments. Inspection : Consignee for supply portion | — | — | — | 1,18,306.05 | |
| — | 4.00 | — | — | ||
| Supply & installation of Optical Fiber cable Joint enclosure as per RDSO/SPN/TC/68/2007 Rev. Amendment no. 1 or with latest amendment and splicing of optical Fiber cables(24 Fibers) and testing. This includes provision of joint pit (RCC/pre fabricated) as detail in the technical specification and as advised by engineer at site. Inspection : Consignee for supply item. | — | — | — | 58,899.72 | |
| — | 3.00 | — | — | ||
| Laying of HDPE duct in the trenches including in HDD/Manual Boring and supply pulling of Nylon rope through is at different places as per direction of engineer incharge/Site engineer.It includes Supply of HDPE duct outer dia 40mm & inner dia 33mm as per TEC Gr No. G/CDS-08/02 Nov /2004 with latest amendment with end cap to be provided along with the drum at both ends. (RDSO specs No. RDSO/SPN/TC/45/2013 Rev.2.0). Inspection by consignee for supply item | — | — | — | 2,23,826.88 | |
| — | 3.00 | — | — | ||
| Blowing/Drawing of OFC/Power cable into HDPE pipe. | — | — | — | 34,204.14 | |
| — | 15.00 | — | — | ||
| Supply of spare electric operated lifting barrier GI Boom as per RDSO Drg S-11600 in maximum 4 sections of 8 feet. (set = One copmplete Lifting Barrier GI Boom) . Inspection : RITES | — | — | — | 5,68,937.85 | |
| — | 2.00 | — | — | ||
| Dismantling and releasing single signal post which includes dismantling of signal fittings electrical and mechanical both wheel of sorts,GI pipe pullies,pully stakes wire run from cabin to signal posts etc.All dismantled material to be transported and stacked in the store of SSE/Sig/Store AMV/store or any other store of N.Rly as per consignee. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 Job= 1 Signal) | — | — | — | 2,794.44 | |
| — | 20.00 | — | — | ||
| Supply of Retro Reflective tape Size: 50mm*20 Mtr rolls conspicuity marking tape (Yellow & Red) Inspection:-Consignee | — | — | — | 18,720.8 | |
| — | 1000.00 | — | — | ||
| Supply of 4 conductor dis-connect terminal block for test and measurement 0.8 sq.mm-2.5 sq.mm centre marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carreir rail DIN 35 front entry cage clamp connection Grey wago or similar as RDSO/SPN/189/2004 Rev. 3.0 or latest. Material to be supplied from RDSO approved firm. Inspection : RDSO | — | — | — | 1,36,650 | |
| — | 20.00 | — | — | ||
| Supply of Steel carrier Rail 35x7.5mm/0.039 in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection : Consignee | — | — | — | 2,999 | |
| — | 80.00 | — | — | ||
| Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection : Consignee | — | — | — | 1,516.8 | |
| — | 80.00 | — | — | ||
| Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection : Consignee | — | — | — | 1,274.4 | |
| — | 20.00 | — | — | ||
| Shifting of Exposed cables. The item includes Removal of exposed cable from existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe covered separately. | — | — | — | 1,44,733 | |
| — | 170.00 | — | — | ||
| Earth work for excavation and refilling around location boxes and signals etc. where necessary including 50M lead and 1.5M lift. The lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. The earth work should be well rammed including breaking of clods,levelling and dressing etc. as per instruction of Engr. at site. | — | — | — | 27,817.1 | |
| — | 8.00 | — | — | ||
| Engaging mechanical excavators like JCB or other machineries for regarding and leveling the formation, Dismantling any infringing structures, clearing and removing debris etc., with all lead and lifts etc., complete and as per the instruction of railway representative at site. | — | — | — | 8,837.76 | |
| — | 100.00 | — | — | ||
| Supply and fixing of GI Pipe with 76.6 mm maximumand 75.3 mm minimumoutside dia. and 3.6 mmthickness as perspecification No. IS:1239 (ISI Mark) makeJindal/Tata/Ajanta orSimilar, perforated at adistance of 20cm or less of required length atculvert/bridges/along the cuttings, , suitably concreted at both ends as per drg. No.(NR/S&T/CON/1.4/97 or latest) to be filled withch attered compound. GIpipe clamps of MS flats,bolts and nuts, chattered compound to be supplied by contractor. Inspection- Consignee | — | — | — | 89,057 | |
| — | 250.00 | — | — | ||
| Supply & fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 or latest with coupling on culverts bridges as per Drg. No. NR/S&T/CON/1.4/97 or latest drawing, or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection- Consignee | — | — | — | 2,95,930 | |
| — | 5.00 | — | — | ||
| Cement Concrete of proportion 1:3:6 (Cement: Sand: Stone chips of 25mm nominal size) for miscellaneous items. It includes excavation, ramming of CC byusing vibrator, curing andplastering with cement and sandmixture (aggregate will not exceed beyond 3.8 cm). Note: All materials required for foundation are to be supplied by the contractor. | — | — | — | 15,112.2 | |
| — | 40.00 | — | — | ||
| Supply of Exothermic welding materials for connecting the existing ring earth with new maintenace free earth. (Cad weld or similar) (Per joint = Nos) Inspection- RDSO | — | — | — | 93,333.2 | |
| — | 20.00 | — | — | ||
| Supply of Main Equipotential earth bus bar (MEEB) Copper of size-300x25x6 mm. Inspection- RDSO | — | — | — | 16,677.8 | |
| — | 100.00 | — | — | ||
| Supply of 50 mm x 6 mm (GI Strip) Galvanised steel tape for inter connecting the earth pits. Inspection- Consignee | — | — | — | 47,313 | |
| — | 25.00 | — | — | ||
| Supply of 25mm x 2 mm bare copper strips in the equipment room. Inspection- RDSO | — | — | — | 26,689.75 | |
| — | 180.00 | — | — | ||
| Supply of earth enhancement material for treatment of earth pits as per Specification No. RDSO/SPN/197/2016 Ver 1.0 or latest. Inspection- RDSO | — | — | — | 21,315.6 | |
| — | 50.00 | — | — | ||
| Digging a trench to a minimum depth of 0.5 meter and laying 50x6 mm bare Galvanized steel tape (Interconnecting tape) connecting all the earth pits. Routing and laying 50x6 mm Galvanized steel tape connecting all the earth pits. Carrying out exothermic weld connections onall the earth electrodes to Galvanized steel tape of size 50x6mm for interconnecting the earth pits. It shall be ensured that the distance between any two earth electrodes shall be minimum 3 meter (length of the earth electrode) and max up to 6 meter (twice the length of the earth electrode) to avoid mutual resistance effects. This interconnecting tape shall also be covered with approximately 30 Kg of earth enhancing compound for each 3 meters length. Earth enhancement compound 10Kg along each meter also to be spreaded along the Galvanized steel tape. | — | — | — | 3,887.5 | |
| — | 25.00 | — | — | ||
| Routing and termination of 25x2mm Copper tape/8 mm solid copper round conductor which is to be fixed inside the equipment room with 60mm, 6KVA insulation studs including supply of insulation studs. The separation of the two successive insulation studs hould be 600mm apart. | — | — | — | 1,943.75 | |
| — | 30.00 | — | — | ||
| Routing and connecting all the equipment in the equipment/relay room to SEEB with 10 sq. mm copper cable using copper lugs with stainless steel nut and bolts and fixtures. The work includes laying and routing the copper cable in PVC / conduits/ inside floor and fixing them on wall/floor. | — | — | — | 1,492.8 | |
| — | 20.00 | — | — | ||
| Supply of basic material to construct Maintenance Free Earth for Ring Earth consisting as per Specification No.RDSO/SPN/197/2016 Ver 1.0 or latest & as per RDSO TAN letter No- RDSO-SIGEnB (GEN)/1/2020 dated 30.06.2025 or latest, bonding connections drawing no. SDO/RDSO/E&B/002. (a) Copper bonded steel electrodes of 3.0 m long, 17.0mm dia. minimum with copper bonding thickness of min 250micron and UL listed and marked-1 No. (b) Earth Enhancement compound of RDSO approved brand supplied in sealed bags of min 30-35 Kg.- 1 Nos. (c ) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1no.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) -1no.(e) Copper Strip of 150mm x25mm x 6mm (SEEB)- 1no. Inspection by RDSO for supply portion. | — | — | — | 2,31,675.8 | |
| — | 20.00 | — | — | ||
| Installation of Single Maintenance Free Earth pit as per RDSO Drawing No. SDO/RDSO/E&B/001 which includes the following:-a) Digging/Auguring/Boring of single earth pit of 100mm to 125mm dia. to the depth of approx.3 meter. b) Insertion of 3.0 meter electrode andpenetrating it minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and back filling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 200 x 25 x 6 mm.(e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish,Inspection chamber should be as per IEC62561-5 or latest. The top RCC cover size shall be 400mmX400mmX50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint. | — | — | — | 1,01,743.4 | |
| — | 50.00 | — | — | ||
| Fabrication, Supply, Transportation and installation of RCC earth pit hollow box of size300 mm x 300 mm x300 m by using M20 Grade precast RCC, 50mm thickness, withcover of RCC precast slabs with hook, coversize is 15" x 15" x 2" .All the required materials for this work i.e stones, cement, iron and sand etc. are to be supplied by contractor | — | — | — | 38,411 | |
| — | 100.00 | — | — | ||
| Supply of 35 Sq. mm PVC insulated Single core Multi strands copper conductor (Red/Black/Green) as per IS: 694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection- RDSO | — | — | — | 22,711 | |
| — | 250.00 | — | — | ||
| Supply of 10 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection- RDSO | — | — | — | 24,217.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACSGCC22-231to6.pdf
ATTACHMENT
GCC_April-2022_1.pdf
ATTACHMENT
GCCACS111.pdf
ATTACHMENT
GCC correction slip 7 to 10
ATTACHMENT
182SFHSadarROBORN-
ATTACHMENT
GCCAdvanceCorrectionSlipno7-10.pdf
ATTACHMENT
TD-14-2026-27RUBLC-182SFHSadarROBORN-3Bridges_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .