Loading
Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
18 Jun 2026, 12:00 pm
CIVIL SURGEON DEOGHAR
CIVIL SURGEON OFFICE DEOGHAR
RATE CONTRACT FOR EQUIPMENT
2026_NHMD_114813_1
02/2026-27/840
Open Tender
Miscellaneous Works
WORK
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹1 L
5 Jun 2026
5 Jun 2026
19 Jun 2026
6 Jun 2026
18 Jun 2026
10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Stainless Steel Abdominal Hysterectomy Set | - | Nos. | - | - |
| 2 | N.S.V set (S.S) | - | Nos. | - | - |
| 3 | G.v set | - | Nos. | - | - |
| 4 | Self Abdominal detractor | - | Nos. | - | - |
| 5 | M.T.P set. | - | Nos. | - | - |
| 6 | Vaccine Carrier (small Size) | - | Nos. | - | - |
| 7 | X-ray Digitalisation with High-End CR System (with Installation & 1 Yers. Warrenty) Console software with mulitmodality work station the CR system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol. | - | Nos. | - | - |
| 8 | Digital ultrasound Machine colour dopler (High Resolution ) with 4 probe | - | Nos. | - | - |
| 9 | Semi auto analyzer | - | Nos. | - | - |
| 10 | Fully Automated Bio-Chemistry Analyzer
Technical Specifications
Throughput-150T/Hr (Constant With Both Mono And Double Reagent)
System Function-Random Access/Stat/Batch
Test Method-End Point, Fix Time, Kinetic, (Single/Double Reagents Chemistry, Mono/ Bio-Chromatic Measurements)
Calculation Methods-1 Point Linear, 2 Point Linear, Exponential, Logit Log3p, Logit Log 4 P, Logit Log 5p, Spline, Line Graph, K Factor
Blank-Reagent Blank, Sample Blank, Pre Sample Blank, Pre Reagent Blank
Sample Tray-40 Position, Sample Volume :2-30 uI, 0.1 ul Increment, Micro Cup, & Test Tube Can Be Used For Sample
Reagent Tray-80 Position, Reagent Volume: 20-300 ul, 1 ul Increment
Mixing System-Teflon Coated Mixer
Sample Probe-1 Needle With Liquid Detector, Shock Sensor
Optics-Halogen-Tungsten Lamp, Absorbance Range: 0-4.0 Abs Resolution: 0.0001 Abs.
Diffraction Photometry With Wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 More Options
Wash Station-12 Step Washing, 4 Needle Wash Station, 1 Dry Pad, External Needle Cleaning
Calibration-Linear And Non-Linear
Qc-Multi-Level Qc Setup With Levy-Jennings Graph And Westgrads Multi Rules With Mean SD, And CV
Water Consumption-Not more than 6L/Hr
Temperature-Reagent: 2-14° C (24 Hr Refrigeration), Reaction cuvette: 37c±0.1°
Humidity-≤80%
System Interface-USB
Power Requirement-Ac 220v ±10%, 50/60 Hz
Dimensions-750 mm*560mm*530mm | - | Nos. | - | - |