Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.6 L+₹65,498.30 (3.85%)Rejected-Finance | L2 | Rejected-Finance Being Not Lowest Tenderer | |
| 3 | L3₹18.4 L+₹1.4 L (8.19%)Rejected-Finance 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L3 | Rejected-Finance Being Not Lowest Tenderer | |
| 4 | L4₹18.6 L+₹1.6 L (9.22%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-Finance Being Not Lowest Tenderer | |
| 5 | L5₹18.6 L+₹1.6 L (9.49%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L5 | Rejected-Finance Being Not Lowest Tenderer |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
5 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
MAINTENANCE AND REPAIRS TO EXTERNAL ELECTRIC SUPPLY AND CONNECTED WORKS AT ARMY AREA COIMBATORE AND MADUKKARAI UNDER GE WELLINGTON
2022_MES_561947_1
8746/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Coimbatore
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹37,000
Yes
8 Apr 2023
7 Nov 2022
12 Dec 2022
8 Nov 2022
5 Dec 2022
21 Nov 2022
Amount
Taking down old unserviceable PCC pole including dismantling / demolition PCC foundation etc from existing line and removing the debris from site all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation of poles, laying of cable trench etc, not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard /dense soil complete all as specified and as directed.
Returning / Refilling of excavated soil including spreading leveling and well ramming in layers complete all as specified and as directed.
Plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation filling of light poles and stays etc all as specified and directed.
PCC 1:2:4 type B-1 using 20mm graded stone aggregate for pedestal including necessary formwork finished fair using extra cement all as specified and directed.
Removing the surplus soil to a distance not exceeding 50 meters from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and as directed.
GI tubing light grade, 40mm dia bore ISI marked conforming to IS 1239 for protection of cable fixed in wall or laid on trenches including removing taking down existing pipe complete all as specified and as directed.
GI tubing light grade, 80mm dia bore ISI marked conforming to IS 1239 for protection of cable fixed in wall or laid on trenches including removing taking down existing pipe complete all as specified and as directed.
Sand cushioning to PVC cable using clean dry riddled sand obtained from excavation or river sand gently punning below/around cable complete all as specified and as directed. Note: Punned thickness only will be measured.
Well burnt bricks sub class ‘B’ as in protection of cable laid dry, flat abutting each other width wise complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 240 Sqmm 3.5 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 120 Sqmm 3.5 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 95 Sqmm 3.5 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 70 Sqmm 3.5 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 50 Sqmm 3.5 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 35 Sqmm 3.5 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 6 Sqmm 2 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 4 Sqmm 2 core laid in trenches / ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Cleaning of vegetation around two / four pole structure and transformer yard, sub station LT, panel area, generator rooms etc all as specified and as directed.
Straight through cable jointing kit for 1100 Volts grade cable complete with jointing material heat shrinkable and accessories suitable for 3.5/4 core XLPE/PVC insulated armoured Aluminium conductor cable of size 16 Sqmm to 50 sqmm complete all as specified and as directed. Make : M Seal/Cab seal/Denson/RPG
Straight through cable jointing kit for 1100 Volts grade cable complete with jointing material heat shrinkable and accessories suitable for 3.5/4 core XLPE/PVC insulated armoured Aluminium conductor cable of size 70 Sqmm to 95 sqmm complete all as specified and as directed. Make : M Seal/Cab seal/Denson/RPG
Repair and replacement of Power Factor Capacitor Three Phase of capacity including taking down old item of Make Epcose / TC/ Siemens/ BCH / L&T / C&S complete all as specified and as directed.
Repair and replacement of Power Switching Contactor of make Epcose / L&T /C&S complete all as specified and as directed.
Repair and replacement of Power Switching MCB of Triple Pole of cap 20 Amps. of make Epcose / C&S/Hager/Havells / L&T complete all as specified and as directed.
Repair and replacement of APFC relay 8 way Make : AE / Ebrit or equivalent make complete all as specified and as directed.
MCCB of capacity 400 Amps 415 volts four pole 36 KA breaking capacity with adjustable thermal magnetic type complete fixed in repairs all as specified and as directed. Make: C&S Cat Part No CSE3N400ATM4P or equivalent in LEGRAND / SCHNIDER
MCCB of capacity 200 Amps 415 volts four pole 36 KA breaking capacity with adjustable thermal magnetic type complete fixed in repairs all as specified and as directed. Make: C&S Cat Part No CSE2NN250ATM4P or equivalent in LEGRAND / SCHNIDER / INDO ASIAN
MCCB of capacity 100 Amps 415 volts four pole 25 KA breaking capacity with adjustable thermal magnetic type complete fixed in repairs all as specified and as directed. Make: C&S Cat Part No CSE1M125ATM4P or equivalent in LEGRAND / SCHNIDER / INDO ASIAN
MCCB of capacity 63 Amps 415 volts four pole 16 KA breaking capacity with adjustable thermal magnetic type complete fixed in repairs all as specified and as directed. Make: C&S Cat Part No CSE1M125ATM4P or equivalent in LEGRAND / SCHNIDER / INDO ASIAN
Cutting the existing bituminous surface road / concrete floor and including returning filling and making good using PCC 1:3:6 type C1 using 20mm graded stone aggregate 300mm thick to match with the existing surface complete all as specified and as directed.
Welding, grainding, repair of locking arrangement and fixed in repairs of hinges of various size of LT, HT Panels, APFC Panels, Switch board complete all as specified and as directed.
Preparation / cleaning of old painted steel surfaces of LT Panels, HT Switch boards and carrying painting with one coats of synthetic enameled paint first quality paint and writing SM/ MES No. 5 cm height with white synthetic enamel paint writing of block stencil cut MES No. 2cm height all as specified and as directed.
Earthing complete with GI earth plate electrode 60x60cmx6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth wire 32x6mm dia by means of bolts and nuts washers made out of GI and earth wire protected by Galvanized pipe light grade 15mm bore, 40 mm bore medium grade and connected to main control board all as shown in Electrical plate No 5 of SSR part I including necessary earth work and excavations in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick, RCC 1:2:4 cover slab with 8mm dia MS bars etc complete all as specified and as directed.
Supply, install, testing and commissioning of factory made LT cubical panel outdoor type made up of 3.15 mm thick CRCA sheet weather, dust & vermin proof, front opening detachable type complete made up of suitable angle iron frame with locking arrangement duly mounted on angle iron frame of suitable size grouted on PCC plinth, painted with two coats of powder coating over a coat of red oxide primer conforming to IS 8623, IP 54 protection including necessary glands etc at the bottom sheet cover and consisting of insulated copper strip Busbar of 400 Amps capacity mounted on procelain insulator with provision of connecting 3 or 4 Nos of LT XLPE UG Cable complate all as specified and directed.
Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 meters long) fixing in true vertical position including taking down existing pole complete all as specified and as directed.
V.R.Enterprises
rvelectricals
ANAND REFRIGERATION
KUMAR AGENCIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .