| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC 6 KRIPANATH DUTTA ROAD KOLKATA 700 002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | L1 | Accepted-AOC Stands L1 and Satisfactory | |
| 2 | L2₹2.8 L+₹7,150.80 (2.61%)Rejected-Finance 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L2 | Rejected-Finance Stands L2 | |
| 3 | L3₹2.8 L+₹8,461.78 (3.09%)Rejected-Finance PATRA MARKET KRISHANAGAR NADIA | KRISHANAGAR | NADIA | L3 | Rejected-Finance Stands L3 | |
| 4 | Rejected-Technical BAZARPARA BAZARPARA ULUBERIA HINDUPARA HOWRAH 711316 | ULUBERIA | HOWRAH | WEST BENGAL | 711316 | - | Rejected-Technical Validity of Electrical Contractors License Expired, Prequalification Application not submitted |
Tender Value
Refer Docs
EMD Value
₹7,500
Closing Date
20 Jan 2023, 3:30 pmClosed
Executive Engineer, Asn Mech Divn, PHE Dte
Janasasthya Karigori Bhaban, Sen-Releigh Road, Opp ESI Hospital, Asansol - 05
Testing, servicing, configuration and calibration of Kalyaneswari Sub-Station electrical equipments and other related work at Kalyaneswari Water Works under RCFA-I Water Supply Scheme.
2022_PHED_438693_3
WBPHE /EE/AMD/NIT 48e / 2022-2023
Open Tender
Electrical Work/ Equipment
Item Wise
10 days
Kalyaneswari
Please refer Tender documents.
3 documents required · 3 mandatory
₹7,500
5 Apr 2023
28 Dec 2022
24 Jan 2023
28 Dec 2022
20 Jan 2023
28 Dec 2022
Amount
Testing of all relay viz earth fault, over load, buchholz and checking of master trip, trip circuit supervision, CT, PT, spring charging system, closing/trip coil, breaker of HT and LT panel etc. Including calibration of Ammeter, Voltmeter, Power Factor Meter etc. by agency approved by directorate of Electricity/WBSEDCL/Any power generating unit and submission of the Test Report to Department (4 Panel 33KV VCB, LT Panel, 1200A ACB-5Nos., SFU-630A : 7 Nos., SFU-400A : 1 No., SFU-250A : 2, SFU-200A : 2 Nos., SFU-125A : 4 Nos., Transformer 1000KVA, 33/0.433KV - 3 Nos., In LT Panel - CDG-31 : 3 Nos. (2 O/C, 1E/F each), In HT Panel - MICOM P127 {(Incomer - 3 O/C, 1 E/F, 1 O/V), Each Outoging (3 O/C (I>,I>>), 1E/F(Ie>,Ie>>)}.
Collection of sample of Transformer oil from 3 Nos. 1000KVA Transformers at Kalyaneswari Sub-Station and carrying it to authroized laboratory for testing including collection of test report after completion of the Testing procedure Following Testing of Transformer oil should be done:- a ) Inter facial tension by Ring Method (IS 6104-1971) b ) Flash point by pensky materns method, IS 1448 (P21)-1992 c ) Neutralization value (acidity) by chemical test, IS 1448 (P2)-1967. d ) Di-electric strength (BDV) by electrode type method, IS 6972-1992. e ) Specific resistance (Resistivity) by three terminal cell method IS f ) Moisture (water) content by Karal Fischer titration method, IS 13567-92 g ) Di-electric dissipation (tanD) by three terminal cell method, IS 6262-1971 h ) Sludge content by chemical test method IS 1866 Annex-A. i ) Dissolve gas analysis (DAG) Gas chromatograph method, IS10593 & 9433 (Transformer oil testing should be done from authorized laboratory and submission of Test Report to department as per direction and to the entire saitsfaction of the EIC.
Add. GST@18%
Add. Cess@1%
EASTERN INDIA SALES AND SERVICE
Tarun Kumar Bhattacharya
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .