| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.9 Cr+₹1,918.50 (0.01%)Admitted-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹1.9 Cr+₹1,918.50 (0.01%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Being banned due to Slow progress by comp auth |
| 4 | Rejected-Technical 191 ROHI BHARWARI KAUSHAMBI 212201 | KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | - | - | Rejected-Technical Due to not enlisted in appropriate category |
| Sl No | Description | Qty | Unit | SHREE Glass and Plywood L1 | Vijaypower Generators Limited L2 |
|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level complete all as specified and as directed. | 7.7 | Cum | 1,500 ₹11,550 | 345 ₹2,656.5 Lowest |
| 2.00 | M&L cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and as directed. | 7.7 | Cum | 6,000 ₹46,200 Lowest | 7,500 ₹57,750 |
| 3.00 | M&L cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts including caps and bases complete all as specified and as directed. | 7.7 | Cum | 7,000 ₹53,900 | 6,000 ₹46,200 Lowest |
| 4.00 | Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed. | 4 | Each | 1,000 ₹4,000 Lowest | 3,000 ₹12,000 |
| 5.00 | S&F 1.25 mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle complete all as specified and as directed. | 7.8 | Sqm | 28,000 ₹2,18,400 | 2,250 ₹17,550 Lowest |
| 6.00 | S&F Pressed steel frames of size 105mm x 60 mm for door with one or more rebates including supply and fixing 125 mm size MS hinges, lock strike plate, etc.complete all as specified and as directed. | 15 | RM | 1,200 ₹18,000 | 700 ₹10,500 Lowest |
| 7.00 | S&F 30mm thick flush shutter , solid core construction with block board core and plywood face panels, both faces are covered with decorative face veneer with lipping/ frame to match complete all as specified and as directed. | 10 | Sqm | 3,300 ₹33,000 | 1,000 ₹10,000 Lowest |
| 8.00 | Dismantling Asbestos cement (corrugated, semicorrugated , etc) sheets n roof coverings. complete all as specified and as directed. | 50 | Sqm | 70 ₹3,500 Lowest | 250 ₹12,500 |
| 9.00 | S&F Pre-painted galvaLume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and as directed. | 50 | Sqm. | 900 ₹45,000 | 450 ₹22,500 Lowest |
| 10.00 | S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and as directed. | 5 | Sqm | 850 ₹4,250 | 500 ₹2,500 Lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
21 Apr 2026, 6:00 pmClosed
CWE(AF) Bamrauli
HQ CWE(AF) Bamrauli Prayagraj 211012
SPECIAL REPAIR/REPLACEMENT OF VCB AND TRANSFORMER UNDER GE(AF) BAMRAULI
2026_MES_756473_1
87587/C/E8
Open Tender
Civil Works
Item Rate
182 days
BAMRAULI
MES Enlisted Contractor of Class B category b ii
8 documents required · 8 mandatory
₹1,000
GE(AF) BAMRAULI
₹2.1 L
Yes
8 May 2026
16 Mar 2026
28 Apr 2026
16 Mar 2026
21 Apr 2026
7 Apr 2026
16 Mar 2026 - 23 Mar 2026
Demolition of cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level complete all as specified and as directed.
M&L cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and as directed.
M&L cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts including caps and bases complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed.
S&F 1.25 mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle complete all as specified and as directed.
S&F Pressed steel frames of size 105mm x 60 mm for door with one or more rebates including supply and fixing 125 mm size MS hinges, lock strike plate, etc.complete all as specified and as directed.
S&F 30mm thick flush shutter , solid core construction with block board core and plywood face panels, both faces are covered with decorative face veneer with lipping/ frame to match complete all as specified and as directed.
Dismantling Asbestos cement (corrugated, semicorrugated , etc) sheets n roof coverings. complete all as specified and as directed.
S&F Pre-painted galvaLume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and as directed.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and as directed.
M&L roof trusses framed), trussed, rail and fastening and bracket framing (Beam, Tee, angle, tubler Section) of FE-410(Gde-E250) quality - B, including distance pieces complete all as specified and as directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed..
M&L Brickwork with subclass "B" bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed
M&L for 15mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces, surface finished even and fair complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:4 on brick work or concrete surface including supply and mixing with water proofing compound @ 3% by weight of cement, surfaces finished even and fair complete all as specified and as directed.
M&L applying two coats of oil bound distemper over one coat of primer including preperation of newly plastered surfaces of wall complete all as specified and as directed.
M&L applying two coats of cement base paint over a coat of primer including preperation of newly plastered surfaces of wall complete all as specified and as directed.
M&L applying two coat of white wash on ceiling including complete removal of existing treatment of ceiling complete all as specified and as directed..
M&L applying two coats of oil bound distemper over one coat of primer including complete rremoval of existing treatment on wall surface complete all as specified and as directed.
M&L applying two coats of of cement base paint on wall surfaces including complete removal of existing treatment on walls surface complete all as specified and as directed.
M&L applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface of any description exceeding 10cm width or girth complete all as specified and as directed.
Excavation in trenches , not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for natural river sand as cushioning of cables including spreading and punning down complete all as specified and as directed. Note : Punned thickness shall be measured for payment purpose
Supply , laying, jointing and testing in replacement of underground HT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 Sqmm 3 Core laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed.
Supply, laying, jointing & testing in replacement of underground LT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core laid in trenches /ducts/ along poles/ through pipe under road etc complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 Sqmm all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover class HVP type 2 with peak size 450 mm x 180 mm x 40 mm complete all as specified and as directed.
M&L 80 mm bore galvanised iron pipe, light grade with all fittings, laid in trenches,under roads, drain paths, fixed to poles/walls with mild steel clamps, bolts, nuts and washers complete all as specified and as directed.
M&L100 mm bore galvanised iron pipe, light grade with all fittings, laid in trenches,under roads, drain paths, fixed to poles/walls with mild steel clamps, bolts, nuts and washers complete all as specified and as directed.
Supply and laying sub class 'B' bricks old size designation 75 as in cable protection complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine of dia 150mm complete all as specified and as directed.
Supply, installation, testing and commissioning of transformer suitable for 315 KVA (Level-3) step down floor mounted outdoor type 11/.433 kVA, 3 phase, 50 Hz AC, IS: 1180-2014 ISI marked, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 (vector group 4) with neutral brought out on LV side with for earthing and having tapping on HV side for constant out put so as to alter/vary secondary voltage by (Tapping range + 5 % to - 10% in equal step of 2.5 % ) changed by means of manualy operated " off load" taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories as specified in SSR Part-I and IS-2026. The limit of temprature rise after continuous full load run as specified in IS-2026 shall be suitably adjusted to suite the maximum ambient temprature of 55 degree centigrade as prevalent at Bamrauli.The transformer shall be complete with the following fittings and accessories :- (a) Oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge (b) Silicagel breather with connecting pipe, first fill of dehydrating agent. (c) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) Air release valve plug
(e) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joint. (f) Explosive vent (g) 01 No 100 mm dia thermometer vapour pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) Thermometer pocket on tank cover (j) 04 Nos plain solid CI detachable rollers (k) Two nos Earthing terminals marking plate. (l) Rating plate and terminal marking plate. (m) Extra bushing for neutral outside the cable box brought out on LV side. (n) First filling of oil conforming to IS and tested upto 60 KV dielectric strenght. (o) Lifting lugs (p) Oil drain valve with plug (q) One cable box on HV side (Primary) consisting of 01 cable gland suitable for reception of taking in HT cable including gland joints.
(w) Extra bushing for neutral out side the LV side (x) PCC plateform shall be provided as per drg No CEAF/TD/EM/03, complete all as specified including XPM welded mesh fencing and doors including 75 x 40 mm channel. Note:- (i) Anything missed above but is required for efficient functioning of transformer is deemed to be included in the unit rate quoted under this item (ii) Full load testing shall be done at site. The artificial load shall be arranged by contractor. (iii) Transformer shall be tested in manufacturer's workshop by the rep of Accepting officer before dispatch.
Supply, installation, testing and commissioning of transformer suitable for 200 KVA (Level-3) step down floor mounted outdoor type 11/.433 kVA, 3 phase, 50 Hz AC, IS: 1180-2014 ISI marked, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 (vector group 4) with neutral brought out on LV side with for earthing and having tapping on HV side for constant out put so as to alter/vary secondary voltage by (Tapping range + 5 % to - 10% in equal step of 2.5 % ) changed by means of manualy operated " off load" taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories as specified in SSR Part-I and IS-2026. The limit of temprature rise after continuous full load run as specified in IS-2026 shall be suitably adjusted to suite the maximum ambient temprature of 55 degree centigrade as prevalent at Bamrauli.The transformer shall be complete with the following fittings and accessories :- (a) Oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge (b) Silicagel breather with connecting pipe, first fill of dehydrating agent. (c) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) Air release valve plug
(e) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joint. (f) Explosive vent (g) 01 No 100 mm dia thermometer vapour pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) Thermometer pocket on tank cover (j) 04 Nos plain solid CI detachable rollers (k) Two nos Earthing terminals marking plate. (l) Rating plate and terminal marking plate. (m) Extra bushing for neutral outside the cable box brought out on LV side. (n) First filling of oil conforming to IS and tested upto 60 KV dielectric strenght. (o) Lifting lugs (p) Oil drain valve with plug
(q) One cable box on HV side (Primary) consisting of 01 cable gland suitable for reception of taking in HT cable including gland joints. (r ) Hand hole of sufficient size to assess interior of tank (s) Dehydrating breather with first filling of Dehydrating agent (t) Two earthing of terminal on tank body to facilitate fixing of 32x6mm GI strip. (u) Rating plate with terminal marking plate (v) Inspection cover (w) Extra bushing for neutral out side the LV side (x) PCC plateform shall be provided as per drg No CEAF/TD/EM/03, complete all as specified including XPM welded mesh fencing and doors including 75 x 40 mm channel. Note:- (i) Anything missed above but is required for efficient functioning of transformer is deemed to be included in the unit rate quoted under this item (ii) Full load testing shall be done at site. (iii) Transformer shall be tested in manufacturer's workshop by the rep of Accepting officer before dispatch.
Supply, installation, testing and commissioning of transformer suitable for 160 KVA (Level-3) step down floor mounted outdoor type 11/.433 KVA, 3 phase, 50 Hz AC, IS: 1180-2014 ISI marked, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 (vector group 4) with neutral brought out on LV side with for earthing and having tapping on HV side for constant out put so as to alter/vary secondary voltage by (Tapping range + 5 % to - 10% in equal step of 2.5 % ) changed by means of manualy operated " off load" taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories as specified in SSR Part-I and IS-2026. The limit of temprature rise after continuous full load run as specified in IS-2026 shall be suitably adjusted to suite the maximum ambient temprature of 55 degree centigrade as prevalent at Bamrauli.The transformer shall be complete with the following fittings and accessories :- (a) Oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge (b) Silicagel breather with connecting pipe, first fill of dehydrating agent. (c) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) Air release valve plug
(e) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joint. (f) Explosive vent (g) 01 No 100 mm dia thermometer vapour pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) Thermometer pocket on tank cover (j) 04 Nos plain solid CI detachable rollers (k) Two nos Earthing terminals marking plate. (l) Rating plate and terminal marking plate. (m) Extra bushing for neutral outside the cable box brought out on LV side. (n) First filling of oil conforming to IS and tested upto 60 KV dielectric strenght. (o) Lifting lugs (p) Oil drain valve with plug (q) One cable box on HV side (Primary) consisting of 01 cable gland suitable for reception of taking in HT cable including gland joints. (r ) Hand hole of sufficient size to assess interior of tank (s) Dehydrating breather with first filling of Dehydrating agent (t) Two earthing of terminal on tank body to facilitate fixing of 32x6mm GI strip. (u) Rating plate with terminal marking plate (v) Inspection cover.
(w) Extra bushing for neutral out side the LV side (x) PCC plateform shall be provided as per drg No CEAF/TD/EM/03, complete all as specified including XPM welded mesh fencing and doors including 75 x 40 mm channel. Note:- (i) Anything missed above but is required for efficient functioning of transformer is deemed to be included in the unit rate quoted under this item (ii) Full load testing shall be done at site. The artificial load shall be arranged by contractor. (iii) Transformer shall be tested in manufacturer's workshop by the rep of Accepting officer before dispatch.
Dismantling of existing transformer , servo voltage stablizer and VCB including transportation from the existing location to MES store yard of GE(AF) Bamrauli complete all as specified and as directed
The VCB shall have the standard of IEC 62271-100, 400Amps, 11 KV, 50Hz with short circuit current rating 25 KA for 3 secs. The breaking capacity of VCB shall design for 25 KA and making capacity of 62.5 KA peak with maximum temperature rise over ambient shall be within limits as per IEC 2271-100. The contact resistance of main pole<60 micro-ohms, dry-1minute power frequency with stand between line terminal and ground object-28KV rms, between terminals with breaker contact open 25kv rms 1.2/50 micro second full wave impulse between line terminals and grounded object. The spring charging motor shall have 230V AC and charging time required for motor 15 sec (Max). The ground clearance of VCB shall be as per manufacturers GA drawing. The panel shall be designed for floor mounting, free standing, simplex type control and realy panel in sheet enclosure with powder coated paint after suitable pretreatment with IP4X protection.
The panel shall be fabricated from 2mm MS sheet for side/top/Rear and with 3.15mm for front/Gland plate paint shade exterior shade 631 of IS-5. Panel size shall not be less than 750mm(width)x600mm(Depth)x220mm (including 100mm base channel). the CT and PT shall be designed suitable for connecting of 500KVA transformer. Make of VCB: ABB/SCHNEIDER/SIEMENS as approved Note :- (i) Any other spares/material required for protection of transformer/VCB may be included as per design parameters. (ii) The quoted rate shall be demmed to include cost of PCC foundation and PCC plateform of suitable size 100 mm thick PCC 1:2:4 type B1using 20 mm graded stone aggregate over 100 mm thick stone hard core of guage not exceeding 63 mm complete. (iii) VCB shall be tested in manufacturer's workshop by the rep of Accepting officer before dispatch.
M&L for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground vertically to depth not less than 3.0 metre below normal ground level (with top edge of earth plate not less than 2.25 metre below ground level), connected to copper strip 20mm x 3.15 mm main earthing lead by means of galvanized bolts, nuts and washers with connected to earth test point to main switch board panel etc. all as specified and testing on completion with and including necessary excavation and earth work, in any type of soil, adequate quantity of charcoal dust and common salt, test point, earth pit covered with precast (RCC 1:2:4) type B1 (using 20mm graded stone aggregat) 40 mm thick cover, reinforced with 8mm dia TMT bar 3 Nos. dia both way with 12mm round bar handle. GI medium grade watering pipe 20mm dia with funnel, wire mesh all as shown in electric plate No. 3 of MES SSR Part-I and 40mm dia GI medium grade pipe for earth lead protection complete all as specified and directed including testing on completion
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to galvanised strip 32x6mm as earth lead by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe light grade,40mm bore including provn of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with pit cover made out of cast iron of size 300mmx300 mm , minimum wieght 7.5 Kg as per relevant IS including frame, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh including excavation and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 m complete all as per electrical plate No 3 of SSR 2009 Part-I and necessary connection and testing on completion.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
87587TENDERDOCUMENTS.pdf
Tender Documents • 1.51 MB
BOQ_847353.xls
BOQ • 1.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .