Loading…
Loading…
Tender Value
₹9.5 L
EMD Value
₹19,100
Closing Date
28 Sept 2026, 11:00 amDue tomorrow
EEE/CLZ
EEE/CLZ
Provision of audio conference system for meeting hall at zonal office building under North Zone.
2026_MCD_291387_1
EEE-II/TC/2026-27/26.1
Open Tender
Electrical Works
Works
60 days
EEE/CLZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹19,100
18 Sept 2026
18 Sept 2026
28 Sept 2026
18 Sept 2026
28 Sept 2026
18 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm | 24 | PM | 151 | ₹3,624 |
| 1.02 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm | 58 | PM | 168 | ₹9,744 |
| 1.03 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. | 2 | Each | 807 | ₹1,614 |
| 1.04 | Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. (a) 2 KVA | 1 | Each | 45,894 | ₹45,894 |
| 1.05 | Supplying, installation, testing & commissioning of 1.5/3/6W
metal box ceiling/wall speakers complete as required. | 8 | Each | 1,891 | ₹15,128 |
| 1.06 | Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. | 1 | Each | 1,52,368 | ₹1,52,368 |
| 1.07 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. (a) Speaker Cable Single pair, 2-core, 1.5 sqmm | 46 | PM | 61 | ₹2,806 |
| 1.08 | (b) Speaker Cable Two pair, 2-core, 1.5 sqmm | 28 | PM | 97 | ₹2,716 |
| 1.09 | (c) Speaker Cable Three pair, 2-core, 1.5 sqmm | 24 | PM | 134 | ₹3,216 |
| 1.1 | Supply Installation Testing and Commissioning of 18" Gooseneck cardioid microphone, polar pattern cardioid, frequency range 70-18000 HZ, sensitivity 18m V/Pa, impedance > 2000 ohms, complete with desk stand, switch and chords etc. as required. | 18 | Each | 29,000 | ₹5,22,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
NITConditionsPASystem.pdf
Tender Documents • 0.40 MB
MCD_GCC_2026Latestcirculars.pdf
Other Document • 16.29 MB
BOQ_339845.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .