REPAIR/REPLACEMENT/MAINTENANCE OF SECURITY/STREET LIGHTS, CABLE JUNCTION BOXES, PAINTING OF POLES, REFLECTIVE STRIPS, CABLES, POLES AND OTHER MISC STREET LIGHTING WORKS AT X AREA, L AREA AND TP COMPLEX AT AF STN DIGARU.
2022_MES_517781_2
8553/E8 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Digaru
MES contractor enlisted as class E cat b(i) having deposited standing security of Rs 45,000/- with dept.
5 documents required · 5 mandatory
₹500
Yes
AGE (I) AF Digaru
₹30,000
Yes
8 Aug 2022
26 May 2022
10 Jun 2022
26 May 2022
8 Jun 2022
3 Jun 2022
Amount
Taking down carefully defective security light, street light and flood light fittings (i.e HPSV/ CFL / LED) of any make, any watt & any size from existing street light pole, building, watch tower etc for carrying out repiar/ maintenance of the same including removing of dismantled material from work site.
Dismantling, repair of security/street/flood light fittings i.e HPSV fittings/ CFL fittings/ LED Light fittings of any make, any watt & any size and re-fixing the same in the original position after repair and replacement of unserviceable components complete all as specified and directed by Engr-in-Charge. Note:- Spare parts/ components shalll be measured and paid separately vide item No 03 to 11 here-in-after.
Supply and fixed in repair/replacement electronic ignitor for HPSV 70/150/250/400 watt lamp complete all as specified and as directed by Engr-in-Charge.
Supply only open construction electromagnatic HPSV/MH copper ballast consisting of high quality silicon steel lamination with argon welding, super enamelled copper wire, vacuum impriganated with white resin, terminal block, tapping for 220/240 volts supplied, 50 Hz, AC suitable for 250 watt HPSV lamp complete all as specified and directed by Engr-in-Charge.
All as per item No 04 here in before but for 400 Watt HPSV lamp.
Supply only HPSV lamp 250 watt, 240 volts Tubular shape (SON-T) complete all as specified and directed by Engr-in-Charge.
Supply only HPSV lamp 400 watt, 240 volts Tubular shape (SON-T) complete all as specified and directed by Engr-in-Charge.
Supply only in repair super deluxe low loss electronic ballast consisting of high quality silicon steel lamination, super enamelled copper wire, vacuum, impregnated with white resin, two way terminal block and suitable for 36 watt CFL at 240 volts, 50 HZ, AC supply complete all as specified and directed by Engr-in-Charge.
Sypply only in repair CFL lamp 36 watt complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of electronic driver suitable for LED fitting of 45 to 120 watt complete all as specified and as directed.
S&F in repair/replacement of surge protector suitable for LED fitting of 45/60/90/120 watt complete all as specified and as directed.
M&L Two core copper conductor multistrand 4.0 Sqmm which is connected to Cable junction box to street light.
S&F repair/replacement of GI Pipe 25mm dia, light grade with fixing accessories such as couplers, lock nuts, saddles, pipe bolts etc complete all as specified and directed by Engr-in-Charge.
S&F repair/replacement of GI Pipe 50mm dia, medium grade with fixing accessories such as couplers, lock nuts, saddles, pipe bolts and fixing with above the wall / below ground etc. complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of bracket for street light fittings, 1.2 metre long made to shape as required with 40 mm dia light grade GI pipe, medium grade with and including MS clamp and two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of polycaronate cable junction box of size 300X200X105mm with complete three phase terminal with connecting clamps, nuts, screws etc. complete with fixing arrangement complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of street light fittings complete, 20 Watt LED new generation energy saving roadway luminaire IP-65 degree of protection complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of street light fittings complete, 30 Watt LED new generation energy saving roadway luminaire IP-66 degree of protection complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of street light fittings complete, 45 Watt LED new generation energy saving roadway luminaire IP-66 degree of protection complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of street light fittings complete, 60 Watt LED new generation energy saving roadway luminaire IP-66 degree of protection complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of flood light fittings complete, 50 Watt Jeta Neo Energy saving, environment friendly, long life, LED flood light luminaire with IP-66 degree of protection complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of flood light fittings complete, 100 Watt Jeta Neo Energy saving, environment friendly, long life, LED flood light luminaire with IP-66 degree of protection complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of flood light fittings complete, 160 Watt Jeta Neo Energy saving, environment friendly, long life, LED flood light luminaire with IP-66 degree of protection complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of flood light fittings complete, 200 Watt Jeta Neo Energy saving, environment friendly, long life, LED flood light luminaire with IP-66 degree of protection complete all as specified and directed by Engr-in-Charge.
S&F in repair/replacement of post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge.
M&L for providing and fixing stainless steel SS 304 pipe posts made out of 50mm dia SS pipe with OD of 60mm including welding of base plate at bottom, grinding, polishing etc. complete all as specified and directed by Engr-in-Charge.
Taking down of old unserviciable UG Cable of any size complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches/ ducts/ on poles including all necessary fixing arrangement such as lugs, glands end termination etc of cross sectional area 16 Sqmm, 4 core complete all as specified and directed by Engr-in-charge.
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft / loose soil complete all as specified and directed by Engr-in-charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all specified and directed by Engr-in-charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all specified and directed by Engr-in-charge.
M&L for sand cushioning with coarse sand in trenches for protection of underground electric cable, spread to uniform 23 cm thickness and punned down gently to 18 cm after. Note:- Compacted/ punned thickness of sand layers shall be measured and paid.
Supply and laying well burnt sub class 'B' bricks, laid flat dry in trenches with width of the bricks, laid to the axis of cable for cable protection complete all as specified & directed by Engr-in-charge.
M&L for cement concrete in foundations, filling and mass concrete type D2 1:4:8 with 40mm graded aggregate complete all as specified and directed.
M&L for cement concrete type B1 1:2:4, 20mm graded aggregate as in coping of poles complete all as specified and directed.
M&L for painting of steet light poles 9m long with two coats of aluminium paint including cross arms, clamps and brackets fitted on pole including fixing of retro-reflective adhesive tape of 100mm width with 50mm as blue colour and 50mm as white incl painting of pole number complete all as specified and directed.
Taking down old unsv rusted street light pole incl breaking PCC foundation and clearing from site and S&F steel tubular galvanized swaged pole complete with base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, 9 metres long, incl including fixing of retro-reflective adhesive tape of 100mm width with 50mm as blue color and 50mm as white incl painting of pole number complete all as specified and directed.
M/S B.H. ENTERPRISE
M/s Dhruv Enterprises
M/S Vimal Enterprise
Ms N D Enterpise
M/s Ravi Enterprise
M/S TRADE CENTRE
M/s Rawat Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .