| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC | ₹43.4 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹46.8 LRejected-Finance GURDASPUR ROAD NEAR SAINIK MANDIR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹46.8 L | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹48.5 LRejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹48.5 L | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹53.8 LRejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹53.8 L | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹55.5 LRejected-Finance | ₹55.5 L | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | SAINI AND SAINI BUILDERS L2 | MAMTA ENTERPRISES L3 | Vijaypower Generators Limited L4 | M/s Trade Linker Associates L1 | SHSS ASSOCIATES L5 | JCC ENGINEERS PRIVATE LIMITED L6 | M/S Razdan Buildersand suppliers L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning step down, 11/.433KV (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 315 KVA complete all as specified and directed. | 3 | EACH JOB | 9,40,000 ₹28.2 L | 9,99,999 ₹30.0 L | 11,34,000 ₹34.0 L | 9,20,000 ₹27.6 L | 11,45,000 ₹34.4 L | 12,11,000 ₹36.3 L | 11,95,000 ₹35.9 L |
| 1.01Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 40 degree centigrade and 45 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and should be manufactured and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 amendment. (b) The following standard accessories shall also be provided :- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision (vii) Conservator with oil indicator. (viii) C.I. Rollers with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator) | ||||||||||
| 2.00 | Supply, installation, testing and commissioning step down, 11/.433KV (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 160 KVA complete all as specified and directed. | 1 | EACH JOB | 7,15,000 ₹7.2 L | 6,99,999 ₹7.0 L | 6,59,000 ₹6.6 L | 5,25,000 ₹5.3 L | 7,95,000 ₹8.0 L | 8,15,000 ₹8.2 L | 8,99,000 ₹9.0 L |
| 2.01Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 35 degree centigrade and 40 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and should be manufactured and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 amendment. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs . (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Conservator with oil indicator. (viii) C.I. Rollers with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator) | ||||||||||
| 3.00 | Supply, installation, testing and commissioning step down, 11/.433KV (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 63 KVA complete all as specified and directed. | 1 | EACH JOB | 3,15,000 ₹3.1 L | 3,49,999 ₹3.5 L | 3,44,000 ₹3.4 L | 2,68,000 ₹2.7 L | 3,77,000 ₹3.8 L | 3,90,000 ₹3.9 L | 3,70,000 ₹3.7 L |
| 3.01Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 35 degree centigrade and 40 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and should be manufactured and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 amendment. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs . (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Conservator with oil indicator. (viii) C.I Rollers with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator) | ||||||||||
| 4.00 | Supply, installation, testing and commissioning step down, 11/.433KV (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 250 KVA complete all as specified and directed. | 1 | EACH JOB | 8,30,000 ₹8.3 L | 7,99,999 ₹8.0 L | 9,73,000 ₹9.7 L | 7,82,000 ₹7.8 L | 9,43,000 ₹9.4 L | 9,95,000 ₹9.9 L | 10,10,000 ₹10.1 L |
| 4.01Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 40 degree centigrade and 45 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and should be manufactured and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 amendment. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision. (vii) Conservator with oil indicator. (viii) C.I Rollers with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator) | ||||||||||
| 5.00Note : All Transformers to be supplied in this BOQ must be atleast Energy Efficient Level Rating-2, BIS Marked & BEE Star labelled, Deduction for schedule of credit (Sch A Part-ii) to be made of Rs 0.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents". | ||||||||||
Tender Value
₹50.5 L
EMD Value
₹1.0 L
Closing Date
5 Jan 2026, 6:00 pmClosed
Anurag Anand DCWE
HQ 135 WKS ENGRS PIN 914135 C/O 56 APO
SPL REPAIR AND REPLACEMENT OF TRANSFORMER AGAINST BER UNDER GE N AKHNOOR
2025_MES_743547_1
CWE/JA-02/2025-26
Open Tender
Electrical and Maintenance Works
180 days
AKHNOOR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE NORTH AKHNOOR
₹1.0 L
Yes
5 Mar 2026
8 Dec 2025
8 Jan 2026
8 Dec 2025
5 Jan 2026
29 Dec 2025
Supply, installation, testing and commissioning step down, 11/.433KV (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 315 KVA complete all as specified and directed.
Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 40 degree centigrade and 45 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and should be manufactured and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 amendment. (b) The following standard accessories shall also be provided :- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision (vii) Conservator with oil indicator. (viii) C.I. Rollers with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
Supply, installation, testing and commissioning step down, 11/.433KV (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 160 KVA complete all as specified and directed.
Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 35 degree centigrade and 40 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and should be manufactured and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 amendment. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs . (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Conservator with oil indicator. (viii) C.I. Rollers with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
Supply, installation, testing and commissioning step down, 11/.433KV (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 63 KVA complete all as specified and directed.
Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 35 degree centigrade and 40 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and should be manufactured and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 amendment. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs . (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Conservator with oil indicator. (viii) C.I Rollers with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
Supply, installation, testing and commissioning step down, 11/.433KV (at no load) transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dy -11 connection of capacity 250 KVA complete all as specified and directed.
Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 40 degree centigrade and 45 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and should be manufactured and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 amendment. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision. (vii) Conservator with oil indicator. (viii) C.I Rollers with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
TENDER.pdf
Tender Documents • 0.76 MB
BOQ_832570.xls
BOQ • 9.43 MB
Download all tender documents and submit your bid