Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 LQualified Make: LIFEGUARD
Model: LG-134 B 38 MANGOLPURI INDUSTRIAL AREA PHASE II DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Make: LIFEGUARD
Model: LG-134 | ₹1.4 L | L1 | Qualified |
| 2 | L3₹1.6 L+₹11,196 (7.78%)Qualified Make: SAFEPRO
Model: SPFSPL4.5CO 16 1ST FLOOR CHUNAWALA BUILDING NEAR AL SADIQ HOSPITAL MOHAMMAD ALI ROAD MANDVI MUMBAI MAHARASHTRA 400003 | MUMBAI | MAHARASHTRA | 400003 | Make: SAFEPRO
Model: SPFSPL4.5CO | ₹1.6 L+₹11,196 (7.78%) | L3 | Qualified |
| 3 | L4₹1.6 L+₹14,436 (10.0%)Qualified Make: SAFETY PLUS
Model: SAFETY PLUS & SPCO24.5 2A SF JIA SARIA VILLAGE DELHI16 N | Make: SAFETY PLUS
Model: SAFETY PLUS & SPCO24.5 | ₹1.6 L+₹14,436 (10.0%) | L4 | Qualified |
| 4 | L5₹1.6 L+₹15,336 (10.7%)Qualified Make: Firestop
Model: Firestop & FEC4 153 K L SECTOR 53 EPIP KUNDLI SONEPAT SONIPAT HARYANA 131028 | SONIPAT | HARYANA | 131028 | Make: Firestop
Model: Firestop & FEC4 | ₹1.6 L+₹15,336 (10.7%) | L5 | Qualified |
| 5 | L7₹1.6 L+₹17,964 (12.5%)Qualified Make: SAFETY FIRE
Model: New Bharat Fire & SFC02 KAMPTEE LINE RAJNANDGAON CHHATTISGARH 491441 INDIA | RAJNANDGAON | CHHATTISGARH | 491441 | Make: SAFETY FIRE
Model: New Bharat Fire & SFC02 | ₹1.6 L+₹17,964 (12.5%) | L7 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
25 May 2018, 3:00 pmClosed
Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 36 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure
Gas Cartridge Type Extinguishing Media Carbon Dioxide Based Water Based
Foam Based
Powder Based
Carbon Dioxide Based
Clean Agent Expellant Medium CO2 Extinguishing Medium CO2 Cartridge Based
N2 Based (Stored Pressure)
CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2
4
6
9
NA Powder Based Fire Extinguisher Capacity (Kg) NA 1
2
NA 1/3 Carbon Dioxide Based Fire Extinguisher Capacity (Kg) 4.5 4.5 Water Based Fire Extinguisher Capacity NA 2
NA Clean Agents Fire Extinguisher Capacity (Kg) NA 2
NA Weight of Filled Portable Fire Extinghuisher (Kg) 17 Rechargebale true - Color Coding Black - Fire Extinguisher Suitable for Class -A Fire false - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -10° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 NA - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) 250 Bar - Discharge Range for Extinguisher (Meters) >=1 for Class-B - Effective Discharge Time for Fire Extinguisher
Min (Seconds) 8 Fire Rating for Class -A Fire Extinguisher NA - Fire Rating for Class -B 34B - 2/3 Fire Extinguisher Certification BIS Marking Yes - CM/L No.* with Validity Period 3985085/22-08-2018 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. 539 - Test Report Date 30-01-2018 - Name of the Lab Advance Firetec And Research Lab Pvt Ltd - Address of the Lab B-3
Mangolpuri Indl Area
Phase II
Delhi 110034 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 ANUBHA AGGARWAL 160002
Plot No 183 Industrial Area Phase 1 Chandigarh 36 15 EMD Required No ePBG Required No
89531
GEM/2018/B/12774
Portable Fire Extinguishers IS 15683
15 days
Chandigarh; Chandigarh
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 36 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure | - | - | - |
| Gas Cartridge Type Extinguishing Media Carbon Dioxide Based Water Based | - | - | - |
| Foam Based | - | - | - |
| Powder Based | - | - | - |
| Carbon Dioxide Based | - | - | - |
| Clean Agent Expellant Medium CO2 Extinguishing Medium CO2 Cartridge Based | - | - | - |
| N2 Based (Stored Pressure) | - | - | - |
| CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Powder Based Fire Extinguisher Capacity (Kg) NA 1 | - | - | - |
| 2 | - | - | - |
| NA 1/3 Carbon Dioxide Based Fire Extinguisher Capacity (Kg) 4.5 4.5 Water Based Fire Extinguisher Capacity NA 2 | - | - | - |
| NA Clean Agents Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| NA Weight of Filled Portable Fire Extinghuisher (Kg) 17 Rechargebale true - Color Coding Black - Fire Extinguisher Suitable for Class -A Fire false - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -10° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 NA - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) 250 Bar - Discharge Range for Extinguisher (Meters) >=1 for Class-B - Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 8 Fire Rating for Class -A Fire Extinguisher NA - Fire Rating for Class -B 34B - 2/3 Fire Extinguisher Certification BIS Marking Yes - CM/L No.* with Validity Period 3985085/22-08-2018 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. 539 - Test Report Date 30-01-2018 - Name of the Lab Advance Firetec And Research Lab Pvt Ltd - Address of the Lab B-3 | - | - | - |
| Mangolpuri Indl Area | - | - | - |
| Phase II | - | - | - |
| Delhi 110034 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 ANUBHA AGGARWAL 160002 | - | - | - |
| Plot No 183 Industrial Area Phase 1 Chandigarh 36 15 EMD Required No ePBG Required No | - | - | - |
Exempted
25 May 2018
15 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_89531.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .