Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical PLOT NO 64 DOOR NO 2 4TH EAST STREET KAMARAJ NAGAR THIRUVANMIYUR CHENNAI 600 041 | CHENNAI | THIRUVANMIYUR | TAMIL NADU | 600041 | Accepted-Technical Accepted |
| 2 | Accepted-Technical 155 A KAIKATTIPUDUR TIRUPPUR ROAD AVINASHI 641654 | AVINASHI | TIRUPPUR | TAMIL NADU | 641654 | Accepted-Technical Accepted |
Tender Value
₹52.1 Cr
EMD Value
₹52.1 L
Closing Date
15 Nov 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commissioner, Punjai puliampatti Municipality
Commissioner, Municipal office, Punjai puliampatti
AMRUT2 Improvements to water supply scheme
2022_MAWS_256955_1
1299/2020/E1
Open Tender
Civil Works - Water Works
Works
365 days
Punjai puliampatti
Please refer Tender documents.
6 documents required · 6 mandatory
₹52.1 L
COMMISSIONER PUNJAI PULIAMPATTI MUNICIPALITY
₹52.1 L
municipal office punjai puliampatti
22 Nov 2022
17 Oct 2022
16 Nov 2022
17 Oct 2022
15 Nov 2022
18 Oct 2022
27 Oct 2022
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SUPPLY, DELIVERY AND ERECTION OF RAW WATER VERTICAL TURBINE PUMPSETS AT HEADWORKS | |||||
| 1.01 | Supply and delievery of Vertical Oil lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging 4300 lpm against a total head of 33 m of water column due to all causes of water column due to all causes with surface recharge head confirming to IS 1710 and as amended as as on date with following accessories to suit the site condition. The speed No.of stages, sizes of column pipes and line shaft indicated is based on site condition prevailing during investigation. The pump should be supplied with non reverable ratcher pin housing safety clutch, suction strainer etc. Each pump should be coupled to a suitable. a) Bowl assembly with bronze impeller, discharge case, CI Bell mouth, strainer b) Suitable mm dia S.S.401 head shaft.c) Suitable mm dia SS 401 line shafts of 1.5 m length with required numbers to suit the well depth.d) Suitable mm dia and suitable mm thick MS oil tube to the required length and numbers. | - | - | - | - |
| 1.02 | e) Bronze line shaftkl bearing required Nos. f) Rubber stabilizer required Nos. g) GM basketkl type strainer of suitable dia. h) ERW suitable mm dia flanged joint/column pipe 1.5 m length required Nos.One suspension length of 7m with length extra column pipe assembly.I) MS clamps suitable for column pipe/oil tube required Nos./line shaft j) Suitable spanner set - 1 set k) Solenoid coil operated lubricating system - 1 set The pump should be coupled to a suitable vertical hollow shaft, flange mounted construction continuous rated squirrel cage induction Motor conforming to latest I.S. 325/1978. | - | - | - | - |
| 1.03 | The motor should be suitable for operation at 415 volts, 3 Phase, A.C. supply 50 H.Z, with F Class insulation SPDP enclosure, Degree of protection IP 23 conforming to latest I.S. 325 with inbuilt thrust bearing assembly and non reverse ratchet assembly etc. complete. The motor should also be suitable for operation with a voltage variation of + or - 10% and frequency variation of + 5% and any combination of these two. NOTE: 'I) The pump should deliver not less than 8861 lpm at duty head of 88 m even @ 47.5 cycles frequency while any 1 No of pumpsets is running . Accordingly the pumpsets have to be designed. However positive tolerance on discharge can be allowed as per relevant IS but no negative tolerance is allowed ii) Torque of the motor should not get over load at any point of operation between lowest water level and maximum water level. | - | - | - | - |
| 1.04 | 4300 Lpm x 33 m turbine pump (Oil lubrication) | 2 | Nos | - | - |
| 1.05 | Supply and delivery of vertical Hollow shaft Squirrel cage induction motor (40Hp) (IS 325) suitble for the above pump continuous rated SPDP Class 'F' insulation, squirrel cage induction motor confirming to IS 325 for operation in AC, 3 Phase/50 HZ 415V(+6%,-15%) running with a speed of pump noted abovel and with in built thrust bearing assembly capable of taking up the entire load and non - reverse ratchet assembly etc., complete. | 2 | Nos | 10 | ₹20 |
| 1.06 | The motor rating notled above is the minimum and shall be such that it should anever be over loaded when the pump works at MWL conditionl and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficiency motors to have maximum efficiency at high power factor. Separate thurst bearing assembly could also be supplied to take up the down load.(40HP) | - | - | - | - |
| 2 | Supply and delivery of Flex compensated Magnetic Amplifier Soft Staters of air cooled suitable for the squirrel cage induction motor for operation in AC 3 phase /50 HZ/415 V (+6%or -10 %) to have smooth starting of motor with gradual acceleration and reducing the starting current. The starter should have under voltage, over load relay, with suitable ammeter indicater lamp, etc. The starter should act as auto transformer starters as protective devices including all taxes, duties and F.O.R. at site. i)Under Voltage release with no volt coil ii)Over load relay with oil dash pot arrangements.iii) Single phasing preventor.v) Mounted on Ammeter. vi) Earth leakage relay.(30 to 371W) | 2 | sets | 10 | ₹20 |
| 3 | Supplying, fixing, testing, commissioning tamper proof LT metering cubical with suitable rating CTs, bus bar, fuse cut as per TNEB specification for accomodating 1 No. Energy meter supplied by TNEB including all accessories complete as directed by the Engineer. The metering cubicle shall have a suitable size glass window for viewing the mater reading without opening the front cover etc. complete.
Upto 75 HP/56KW (which includes LT meter panel board 6 Nos. suitable fuse carriers) | 1 | set | 10 | ₹10 |
| 4 | Supply, delivery and errection and commissioning of floor mounting type weather vermin and dust proof powder coated L.T cubical panel board made of 14 SWG M.S sheet and M.S angle iron frame work with enclosed 4 Nos. of Aluminium bus bars of Electrolyte grade E.91, PVC sleeved of suitable size for phase and neutral with hinged front door and railway type lock and key arrangements. The bus bars shell be of ample current carrying capacity with all internal wiring as per I.E rules and as per IS 8633 and as per safety requirement of CEIG. The panel board should be completed with all internal wiring including necessary twin copper earthing arrangements and consists of the components for controlling incoming and outgoing supply. I. The incomer shell be provided with: a) 1 No. of 400 Amps, 500V, 3 phase MCCB with over current and short circuit releases to control the incoming supply to the bus bars in the cubical board from the power supply. b) 1 No. of 144mm square type 0-500V, digital volt meter with phase selector switch and slide lock fuses, one for the motor and the other for capacitor bank in the outgoing feeder. c) 2No. of 144mm square type 0 to 300 Ampere, digital Ammeter meter with phase selector switch and slide lock fuses, one for the motor and the other for capacitor bank in the out going feeder. d) 1No.of three phase, 4 wire digital KW Hr. meter for direct reading. f) 1No. of 144mm square type digital P.F meter. g) 5No. of RYB and LED ON/OFF indicating lamps with control fuse / switch. h) 1 set C.T.suitable for the instruments. i) 1 set Earth fault Relay. II. The Outgoing feeder shell be provided with: a) 2No. of 200Amps, 1No. of 125Amps, 1 No. of 63Amps, 1No. of 32Amps 4 pole MCCB to control outgoing supply. | 1 | No | 10 | ₹10 |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ_303905.xls
BOQ Document • 0.82 MB
107161477.pdf
Tender Document • 1.26 MB
TechnicalBid.pdf
Tender Document • 0.99 MB
107161481.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .