The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
*Similar nature of work means: "Erection and commissioning of 25 KV O H E . O R Erection/Modification of power supply installations for 25KV O H E . O R Erection and commissioning of 132 KV and above voltage transmission line. O R Erection and commissioning of 132/33 KV and above voltage level substations"
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Design, Supply, Erection, Testing & Commissioning of Boundary post in connection with 2x25 KV AT feeding System in Pradhankhanta-Manpur GC section of Dhanbad Division under Railway Project Danapur of East Central Railway.
RPECRDNRELHSBPDHN
RPECRDNRELHSBPDHN
Open
Works - General
12 Months
Patna, Bihar
₹0
₹23.6 L
30 Apr 2025
7 Apr 2025
110 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 41,09,44,132.85 | ||
| Preparation of design and drawing & supply in 08 copy | — | — | — | 2,44,744.29 | |
| Reinforced Concrete for foundation & trench. | — | — | — | 27,13,560 | |
| Making of Cable trench covers. | — | — | — | 13,07,518.2 | |
| Brick work in foundation plinth, retaining walls and drainage | — | — | — | 32,41,998 | |
| Concrete for Foundation (Normal soil) | — | — | — | 3,24,38,820 | |
| Concrete for Foundation Rocky Soil. | — | — | — | 27,02,246.4 | |
| Supply of galvanization steel structure including traction mast, main masts, fabricated steel other than mast, SPS, Tower gantries, Portal, supporting structure & small part steel work. | — | — | — | 7,05,42,967.5 | |
| Erection of galvanization steel structure including traction mast, main masts, fabricated steel other than mast, SPS, Tower gantries, Portal, supporting structure & small part steel work. | — | — | — | 14,46,573.75 | |
| Supply of Aluminum jumper. | — | — | — | 1,21,777.92 | |
| Erection of Aluminum jumper. | — | — | — | 10,321.56 | |
| Supply of Guy rod assembly as per RDSO drg.No. ETI/OHE/P/ 5000 or latest. | — | — | — | 2,00,232 | |
| Erection of Guy rod assembly | — | — | — | 33,372 | |
| Supply of 25 KV single pole Isolator complete | — | — | — | 5,47,625.64 | |
| Erection of 25 KV single pole Isolator complete | — | — | — | 27,305.76 | |
| Supply of M.S. Flat 40 x 6mm (IS 2062) Length 6/6.5 mtr. | — | — | — | 3,71,000 | |
| Fabrication and Erection of M.S. Flat 40 x 6mm . | — | — | — | 60,589.75 | |
| Supply of 40x60mm MS flat structure bond(4.75 m). | — | — | — | 1,84,233 | |
| Erection of 40x60mm MS flat structure bond(4.75 m). | — | — | — | 33,567 | |
| Supply & erection of GI Nut Bolt (16x50x38) | — | — | — | 34,070 | |
| Drilling of Hole for Bond. | — | — | — | 25,750 | |
| Supply of Number plate as per Drg.No.ETI/ OHE/P/7501 or latest | — | — | — | 3,24,450 | |
| Erection of of Number plate | — | — | — | 21,115 | |
| Provision of 234 sq.mm Aluminum (Spider conductor) feeder wire .(i) Supply | — | — | — | 41,59,293.84 | |
| Provision of 234 sq.mm Aluminum (Spider conductor) feeder wire .(ii) Erection | — | — | — | 1,17,232.56 | |
| Supply and erection of materials for termination of Aluminium Feeder wire. | — | — | — | 3,07,163.88 | |
| Supply of Fencing Pannels. | — | — | — | 36,22,725 | |
| Erection of Fencing Pannels. | — | — | — | 1,11,820.5 | |
| Supply of Fencing Uprights. | — | — | — | 26,57,838.96 | |
| Erection of Fencing Uprights. | — | — | — | 77,905.62 | |
| Supply of Gates . | — | — | — | 1,21,765.05 | |
| Supply of Anti-Climbing device at sub-stations. | — | — | — | 5,88,546 | |
| Erection of Anti-Climbing device at sub-stations. | — | — | — | 11,772 | |
| Supply of 8 MVA, 2x27.5KV Auto transformer with Bushing CTs(RDSO Spec. No. TI/SPC/PSI/ AUTOTR/1200) or latest. | — | — | — | 13,50,00,000 | |
| Erection, testing and commissioning of 8 MVA, 2x27.5kV Auto transformer with Bushing CTs. | — | — | — | 19,36,962 | |
| Supply of 25KV,Double Pole vacuum Interrupter(2000A)(Spec. No. TI/SPC/ PSI/ LVCBIN/0120 with A&C Slip No.1). | — | — | — | 83,02,716 | |
| Erection, testing and commissioning of 25kV, 2000A Double Pole vacuum Interrupter. | — | — | — | 57,294.45 | |
| Supply of 25 kV single pole Vacuum Type Interruptors. | — | — | — | 27,87,750 | |
| Erection, testing and commissioning of 25 kV single pole Vacuum Type Interruptors. | — | — | — | 41,607 | |
| Supply of 25kV, Double Pole Circuit Breaker (2000A) (Spec. No. TI/SPC/PSI/ LVCBIN/0120 with A&C Slip No.1). | — | — | — | 1,93,28,400 | |
| Erection, testing and commissioning of 25kV, Double Pole Circuit Breaker (2000A) (Spec. No. TI/SPC/PSI/ LVCBIN/0120 with A&C Slip No.1). | — | — | — | 1,14,588.9 | |
| Supply of 5 0 k V , Double Pole Circuit Breaker (2000A) (Spec. No. TI/SPC/PSI/ LVCBIN/0120 with A&C Slip No.1). | — | — | — | 1,93,28,400 | |
| Erection, testing and commissioning of 50kV, Double Pole Circuit Breaker (2000A) (Spec. No. TI/SPC/PSI/ LVCBIN/0120 with A&C Slip No.1). | — | — | — | 1,14,588.9 | |
| Supply of 42kV Lightning Arresters (RDSO Spec./Drg. No. TI/SPC/PSI/ MOGTLA/0101 or latest. | — | — | — | 16,60,313.88 | |
| Erection of 42kV MOGTLA/0101(02/15)) or latest. | — | — | — | 30,682 | |
| — | — | — | No. | ||
| Supply of Potential Transformer Type-I (RDSO Spec.No. TI/SPC/PSI/PTs /0990(09/99)) or latest. | — | — | — | 4,46,200 | |
| Erection of Potential Transformer Type (I) (RDSO Spec.No. TI/SPC/PSI/ PTs /0990(09/99)) or latest. | — | — | — | 4,149.2 | |
| Supply & Erection of 27.5 KV/240V , 10kVA LT Supply Transformer as per RDSO specf. No. ETI/PSI/15 | — | — | — | 1,57,515.84 | |
| Erection, testing and commissioning of 25KV/240V , 10kVA LT Supply Transformer. | — | — | — | 23,576.9 | |
| Supply of 25KV D.O. Fuse switch for 10 KVA A.T. As per RDSO specf. No. ETI/PSI/14 (01/86) | — | — | — | 20,612.32 | |
| Erection of 25KV D.O. Fuse switch for 10 KVA A.T. | — | — | — | 2,706.66 | |
| Supply of 25 KV, 2000 A Doble pole Isolator (Manual) suitable for 2x25kV System. Specf. No. ETI/PSI/122 or 133 | — | — | — | 52,24,154.4 | |
| Erection of 25 KV, 2000 A Doble pole Isolator (Manual) suitable for 2x25kV System. | — | — | — | 1,32,266.16 | |
| Supply of 25 KV Insulator for Isolator 2x25kV DPI (Post Insulator) as per RDSO Spec. No. TI/SPC / OHE/INS/ 0070(4/07) with A&C slip No.1&2 or latest. | — | — | — | 17,44,986.24 | |
| Erection of of 25 KV Insulator for Isolator 2x25kV DPI (Post Insulator). | — | — | — | 1,52,640 | |
| Supply of 25 KV Suspension insulator (9 Tonn Insulators) Porcelain as per RDSO Spec. No.TI/SPC /OHE/INS/ 0070(4/07) with A&C slip No.1&2 or lates. | — | — | — | 15,92,176 | |
| Supply of suspension accessories without Insulator and erection of suspension Insulator with all accessories. | — | — | — | 6,83,696 | |
| Supply & Erection of 11kV Disc Insulator for 25KV Termination Assembly SPEC. No - IS:731-1971 | — | — | — | 3,24,000 | |
| Supply & Erection of AL59 31.5mm Diameter | — | — | — | 11,57,999.4 | |
| Supply & Erection of 50/38 mm Dia Al busbar | — | — | — | 23,77,440 | |
| Supply of copper feeder wire (37/2.25mm HDBC). | — | — | — | 18,63,000 | |
| Erection of copper feeder wire (37/2.25mm HDBC). | — | — | — | 5,602.5 | |
| Supply(other than insulators) of materials (including insulators)for termination of copper cross feeder wire. | — | — | — | 63,17,157 | |
| Erection of materials (including insulators) for termination of copper cross feeder wire. | — | — | — | 8,81,705 | |
| Supply of large copper jumper 160 sq mm between al bus and cross feeder . | — | — | — | 74,59,034.88 | |
| Supply and Erection of large copper jumper 160 sq mm between al bus and cross feeder . | — | — | — | 5,58,184.66 | |
| Erection of Earth wire (19/2.5mm Glavanised Steel Standard Earth wire). | — | — | — | 1,50,592.5 | |
| Supply & Erection of 38.25mm dia (865 Sq.mm) AAC Bull Conductor. | — | — | — | 23,81,400 | |
| Supply & Erection of AAC Spider Jumper (20mm Diameter) | — | — | — | 2,01,001.5 | |
| Supply & Erection of 1.1kV of 1 C x 400 Sq.mm. Cu Cable | — | — | — | 93,15,000 | |
| Supply of 7x2.5 sq.mm copper cable. | — | — | — | 9,93,600 | |
| Erection of 7x2.5 sq.mm copper cable. | — | — | — | 66,240 | |
| Supply of 2x2.5 sq.mm copper cable. | — | — | — | 3,64,320 | |
| Erection of 2x2.5 sq.mm copper cable. | — | — | — | 62,100 | |
| Supply & Erection of Control & Relay Panel for Boundary post(SP). | — | — | — | 1,03,50,000 | |
| Supply of Low maintenance lead acid batteries (150 AH) set with 2 nos. of suitable battery charger. | — | — | — | 20,70,000 | |
| Erection of Low maintenance lead acid batteries (150AH) set with 2 nos. of suitable battery charger. | — | — | — | 90,084.24 | |
| Supply of 240Volt AC Distribution boards in the control room. | — | — | — | 6,68,342.43 | |
| Erection of 240Volt AC Distribution boards in the control room. | — | — | — | 9,135.72 | |
| Supply of 110Volt DC Distribution boards in the control room. | — | — | — | 3,00,183.93 | |
| Erection of 110Volt DC Distribution boards in the control room. | — | — | — | 6,670.17 | |
| Supply of Earth electrode . | — | — | — | 9,65,664 | |
| Erection of Earth electrode. | — | — | — | 3,02,622.75 | |
| Supply of 32 mm dia MS Rod for Earth Mat. | — | — | — | 22,89,262.5 | |
| Erection of 32 mm dia MS Rod for Earth Mat. | — | — | — | 1,43,100 | |
| Supply of Earth Leads 50 mm x 6 mm Mild Steel | — | — | — | 6,98,625 | |
| Erection of Earth Leads 50 mm x 6 mm Mild Steel | — | — | — | 2,94,975 | |
| Supply of earth bus 75x8mm. MS strip laid in the ground | — | — | — | 9,02,497.5 | |
| Erection of earth bus 75x8mm. MS strip laid in the ground | — | — | — | 1,98,202.5 | |
| Supply of gravel/ ballast in switching yard | — | — | — | 12,74,032.8 | |
| Spreading of gravel/ ballast in switching yard | — | — | — | 6,674.4 | |
| Supply & Erection of 6 SWG GI Wire for fencing bonding. | — | — | — | 1,90,440 | |
| Supply & Erection of 8 SWG GI Wire for Gate bonding . | — | — | — | 52,785 | |
| Erection of Burried Rail (13 m Long, 52Kg) including supply of Tin plated copper bush- 02, 20mm dia copper revet -08Nos. And primer painting & painting of buried rail and MS flat.. | — | — | — | 5,14,152.54 | |
| Supply & Erection of Strung Bus Termination Arrangement for 31.5mm AL59 Conductor without disc insulator with adjuster . | — | — | — | 8,02,125 | |
| Supply & Erection of Earth Wire Termination Arrangement | — | — | — | 2,91,766.5 | |
| Supply & Erection of Connectors | — | — | — | 18,63,000 | |
| Supply & Erection of PG Calmps | — | — | — | 1,65,600 | |
| Supply & Erection of 1100kV Copper Cables | — | — | — | 20,70,000 | |
| Supply & Erection of 2C x 70 sqmm Aluminium. | — | — | — | 6,30,232.2 | |
| Supply of Remote station Equipments at Sectioning Posts(SP) as per RDSO Spec. No. TI/SPC/RCC/ SCADA/ 0133. | — | — | — | 86,85,000 | |
| Erection, Testing & Commissioning of Remote station Equipments at Sectioning Posts(SP) as per RDSO Spec. No. TI/SPC/RCC/ SCADA/ 0133. | — | — | — | 5,80,087.89 | |
| Hooking with existing SCADA | — | — | — | 14,92,896.24 | |
| Supply of PTFE TYPE Short Neutral Section(Phase Break). | — | — | — | 1,12,00,914 | |
| Erection of PTFE AF make Neutra section. | — | — | — | 58,799.07 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .