Executive Engineer WD XXII
WD XXII PWD Fatorda
Annual Servicing of 33/0.44 kV substation equipments at Goa College of Engineering , Farmagudi
2026_PWD_28827_1
3/26-27/PWD/WDXXII/MnE/ ASW/TN-03/12 dtd.21.04.2026
Open Tender
Electrical Works
180 days
Ponda
Please refer Tender Notice TN-03 dtd 21.04.2026
6 documents required · 6 mandatory
₹4,000
Yes
₹6,260
Yes
22 May 2026
21 Apr 2026
30 Apr 2026
22 Apr 2026
29 Apr 2026
22 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Servicing of 33kV ABB SF6 circuit breaker includes thorough inspection, testing, and minor repairs/replacements. Clean breaker, top up SF6 gas if below recommended level. Inspect and lubricate mechanisms, linkages, and moving parts. Adjust contact travel and spring tension if needed. Tighten all electrical/mechanical connections. Conduct IR and contact resistance tests. Test tripping/closing coils, control wiring, interlocks, and auxiliary circuits. Perform timing tests (open/close/trip). Verify protection/control relay operations and confirm functionality under load. Use company-recommended consumables. Provide power supply for testing. Only authorized ABB technician to perform service. Record all test results and observations. Submit detailed report with recommendations. Maintain equipment for safe and reliable operation over 1 year. | - | Nos. | - | - | BI01010001010000000000000515BI0100001112 |
| 2 | Servicing of L\&T CN-CS 1250 S1 ACB includes inspection of breaker body, terminals, and insulation for damage, dust, or corrosion. Clean using dry cloth/vacuum. Lubricate moving parts per OEM guidance. Adjust spring tensions and latching. Verify draw-out, racking, and interlocks. Perform IR and contact resistance tests. Test manual/electrical tripping and closing. Conduct open/close timing tests. Check trip unit settings and calibration. Inspect control wiring, terminals, and auxiliary contacts. Simulate faults to verify tripping. Test SR18 release. Confirm operation with load. Record all test data and findings. Note abnormalities and recommend actions. Submit detailed report. Use L\&T kits and approved consumables. Ensure power is available. Only authorised L\&T technician to service. Maintain equipment for safe and reliable operation over 1 year. | - | Nos. | - | - | BI01010001010000000000000515BI0100001113 |
| 3 | 1000 KVA, 33/0.440 KV,1686 litres transformer oil filtration along with testing of the first oil sample and sample at the end of filtration, testing of transformer for IR value before filtration and after filtration aimed at restoring the dielectric strength, removing moisture, gases, and particulates, and improving transformer performance and longevity. The process is to be carried out using a high-vacuum oil filtration plant as per relevant standards (IS/IEC)The job should be complete as per site conditions and departmental requirements. Necessary provision of supply to carry the job should be made available. | - | Job | - | - | BI01010001010000000000000515BI0100001114 |
| 4 | Supply and topping up of new transformer oil | - | Ltr | - | - | BI01010001010000000000000515BI0100001115 |
| 5 | Servicing of 33 kV, 600A GOAB switch, with proper cleaning , greasing and alignment. | - | Job | - | - | BI01010001010000000000000515BI0100001116 |
| 6 | cleaning of insulators , tightening of loose contacts , identifying any hotspots or discolouration of insulators, Complete servicing of four pole 33 kV structure, as per site conditions. | - | Job | - | - | BI01010001010000000000000515BI0100001117 |
| 7 | Replacing of Silica gel breather as per site requirements | - | Nos. | - | - | BI01010001010000000000000515BI0100001118 |
| 8 | Inspecting and tightening of HV/LV terminations for 33/0.44kV , 1MVA transformer complete as per site conditions. | - | Job | - | - | BI01010001010000000000000515BI0100001119 |
| 9 | Bucholz gasket replacement 33/0.44kV transformer | - | Job | - | - | BI01010001010000000000000515BI0100001120 |
| 10 | HT/LT side Terminal box gasket replacement of 1MVA, 33/0.44kV transformer | - | Job | - | - | BI01010001010000000000000515BI0100001121 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.89 MB
Tendernotice_2.pdf
PDF • 0.84 MB
Tendernotice_3.pdf
PDF • 0.46 MB
Tendernotice_4.pdf
PDF • 0.21 MB
BOQ_29266.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid