Balance Construction Work of Science Centre (Category-II) Including Innovation Hub at Lal Mandi Srinagar, JNK.
2026_PWDJK_304877_1
NIT NO 112/RNB/RAJ OF 2025-26 DATED 28/02/2026
Open Tender
Civil Works
Percentage
545 days
SRINAGAR
AS PER THE NIT / SBD
8 documents required · 8 mandatory
₹5,500
AS PER THE NIT/ SBD
₹6.0 L
AS PER THE NIT / SBD
5 May 2026
28 Feb 2026
14 Mar 2026
2 Mar 2026
13 Mar 2026
2 Mar 2026
6 Mar 2026
Finishing/ Plumbing
Brick work with F.P.S (non modular) bricks of class designation 75 in superstructure above plinth level upto Floor V level in 1:6 mix (1 cement: 6 coarse sand) including carriage of all materials from approved sources upto site of work complete.
12mm thick internal cement plaster 1:4 (1 cement :4 fine sand) on all surfaces (walls and RCC surfaces) after proper combing including cost of all materials, skyfolding and curing including cost and carriage of materials involved complete.
Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.Size of tile 600x600 mm
Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. One coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws size) 35 mm thick
Providing and fixing aluminum fittings ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Aluminium handles 125 mm
Aluminium tower bolts 300x10 mm
Aluminium hanging door stoppers 125mm
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing glass 4mm thickness as per specification with first class deodar beading up to size 40 x 20 mm in wooden frames and painting as per specifications.
Providing and fixing Aluminium Composite panel/ 6mm glass cladding (exterior grade) invertical surface using 4mm thick sheet. The sheet shall be bent to shaped profiles asrequired including Perimeter Extrusion base frame extruded stiffeners 2.5 to 3mm, SS expansion fasteners and silicone sealant (Dow Corning 789),all back up arrangements required for installation as per approved Architectural Elevation drawings, complete in all respects.
Proving and fixing Face dressed stone masonry (fine chiseled) in plinth & walls in 1:3 CM (1 cement: 3 coarse sand) including cost and carriage of materials involved complete
Pointing on stone work with cement mortar 1:3(1 cement , 3 fine sand) Raised and cut pointing including cost and carriage of materials involved complete
Clearance of site by way of dismantelling existing stairs by mechanical/ manual means including removal of same from site to out side municipal limits making site workable .
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) including cost and carriage of materials involved complete (Average 70Km)
Reinforcement for RCC works including straightening, cutting, bending, binding & placing in position all complete. HYSD reinforcement of grade Fe-500D steel bars at all levels.
Centering and shuttering including strutting, propping etc. and removal of form work for:-
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Stairs (excluding landings) except spiral staircases.
Applying one coat of water thinnable cement primer of approved brand and manufacture on all surfaces
Distempering with 1st quality acrylic distemper (ready made) of approved manufacturers and of required shade and color complete. Two or more coats on new work including priming coat over POP surface.
Applying priming coat on new wood and wood based surface with ready mixed wood primer
Painting with synthetic enamel paint of approved brand and manufacture of required shade and colour to give smooth finish with two or more coats on new wood and based surfaces
Providing and fixing copper plates as per design for expansion joints density 8.96 g/cm3
Providing and fixxing in position blown bitumin in expansion joints
P/F of following PVC pipes/ Fittings of approved brand including trenching and refilling all complete. (Prince Type-B)
100 mm Pipe
100 mm plain bend
100mm Door tee
100mm Collar
100mm Floor Trap
100mm Reducer
75mm Pipe
75 mm plain bend
75mm Door bend
75mm Collar
P/F of following PPR pipes/ Fittings of approved brand Prince, Reliance, Vectus or equivalent ( heavy duty) including trenching and refilling all complete.
20mm pipe Nominal dia
25 mm Pipe Nominal dia
32mm dia pipe Nominal Dia
20mm stop cock
25 mm stop cock
32 mm stop cock
20mm union
25mm union
32mm union
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as perstandard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
P/F of following C.P fittings of approved brand and make (Parko ) or equavallent including all complete.
15 mm nominal bore bib cock long body
15 mm nominal bore angle valve
C.P Nipple
C.P Cup
Providing and fixing PTMT grating of approved quality and colour. 150 mm nominal size square 100 mm diameter of the inner hinged round grating.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.
P/F of PVC connection 450mm long of approved brand.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Semi rigid pipe 32 mm dia
Tanky Nippels 20mm dia
Tanky Nippels 25mm dia
20mm dia Brass Ball Value
25mm dia Brass Ball Value
32mm dia gun metal Ball Value (vertical)
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 literwhite P.V.C automatic flushing cistern.
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 18.3.1 W.C. pan with ISI marked white solid plastic seat and lid.
Providing and placing under truss (2nd slab level) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting , wall and making good the same in case of recessed conduit as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100mm X 75mm)
4 Module (125mm X 75mm)
6 Module (200mm X 75mm)
8 Module (125mm X 125mm)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing & fixing khatamband ceiling including 12mm ply under later & 1m x 1m mesh frame work of 50mm x 50mm Budloo wood battens including Fixing the meshed frame to the ceiling properly with sufficient no. of gutties and spirit polishing of the ceiling complete job.
Providing and fixing action tisa AC 4 grade wooden laminated flooring 8mm thick for stage including thin film of polythene floor cover complete.as per the directions of Engineer Incharge at site complete.
Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e. vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to centerin a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horizontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre) roll and two coats of primer suitable for panelling as per manufacturer’s specification as per direction of Engineer-in-Charge all complete. With 15 mm thick fully perforated square/butt edge lightweight calcium silicate panels/ tiles
Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (The rate is excluding the cost of tiles which will be paid for separately) 8 mm thick fully perforated Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/cm2, bending strength 100 kg/cm2, of size 595x595 mm, having perforation of dia. 10mm with minimum perforated area 18% with non-woven tissue on the back side, having an NRC (Noise Reduction Certificate) of 0.85, with 50 mm thick rock wool of 48 kg/cum backing.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdiax40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimetre channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part-I : 2011 (Board with BIS certification marks)
12mm thick internal cement plaster 1:4 (1 Cement:4 fine sand) on all surfaces walls, ceiling and RCC surfaces) after proper combing including cost & carriage of all material Skyfoulding & curing.
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate including cost and carriage of materials involved complete.
Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) PCC below rooms - Mudmate for leveling including cost and carriage of material upto site of work complete.
SEPTIC TANK
Clearance of site by way of removing garbage humps extracting of bushes by mechanical/ manual means including removal of same from site to out side municipal limits with roots making site workable for laying of layout for proposed building.
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
Providing and laying of soling stone on level (hand packed ) watering ramming complete below Foundation including carriage all complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) PCC below rooms - Mudmate for leveling including cost and carriage of material upto site of work complete.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)including cost and carriage of material upto site of work complete
Reinforcement for RCC works including straightening, cutting, bending, binding & placing in position all complete. HYSD reinforcement of grade Fe-500D steel bars at all levels.
Centering and shuttering including strutting, propping etc. and removal of form work for:-
Suspended floors, roofs, landings, balconies and access platforms.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Edges of slab and breaks in floors and walls
12mm thick internal cement plaster 1:4 (1 Cement:4 fine sand) on all surfaces walls, ceiling and RCC surfaces) after proper combing including cost & carriage of all material Skyfoulding & curing.
SOAKAGE PIT
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
Dry random rubble masonry with hard stone in foundation and plinth: With bond stone (Quarry) including cost and carriage of material upto site of work complete
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)including cost and carriage of material upto site of work complete (average 7 Km)
Centering and shuttering including strutting, propping etc. and removal of form work for:-
Suspended floors, roofs, landings, balconies and access platforms.
Reinforcement for RCC works including straightening, cutting, bending, binding & placing in position all complete. HYSD reinforcement of grade Fe-500D steel bars at all levels.
Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like.
Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality.HD - 20 Circular shape 560mm internal diameter
Constructing brick masonry road gully chamber of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C. horizontal grating with frame complete as per standard design:Chamber size 45x45x77.50 cm including precast R.C.C grating with frame 450x100 mm vertical grating.
Providing and fixing PVC pipes of 100 mm dia including all random fittings. This includes of joints, excavation, refilling, inclding cost of all fixing accessories complete job as directed by EIC
SITC of Lift
Supply, Installation testing & Commissioning of 01 No. (G+1), 08 Passenger MRL Lift at Construction Of Directorate Office For department of Floriculture At Srinagar including all the necessary civil & electrical works such as chipping of lift shaft if necessary, whitewashing of lift shaft, hoisting, beam/girder in overhead, lighting of lift shaft with provision of 16 amp 3-pin sockets and switches at each floor inside lift shaft, closure of lift shaft by chequered plate/sheet, brick work at landing door, plastering, Filling of pit if necessary, lintel work, granite works for façade/Front wall of lift at each floor, minor civil works and any other work required for successful installation of lift. The lift shall be suitable for 08 passengers, of standard design having speed of 1.0m/s serving from ground to ist floor i.e. 02 stops and 02 landings. The CMC for equipment shall be one year post one year of DLP period The elevator shall be of state of art technology, energy efficient drive and all its components/ accessories shall conform to relevant IS standards. Machine: Gearless machine located in the shaft on the top of guide rails. Power Supply: 400/415 V (3 Phase AC) Car Group: Simplex Full Collective Control Traction Media: To be provided by firm. Required Shaft dimensions: 2150 mm (W) x 1800 mm (D) (as per NBC guidelines). Required Overhead: 4200 mm Required Pit depth: 1600 mm. Landing door: 2 panel automatic centre opening door in stainless steel hairline. Car Finish: Stainless steel in hairline finish. Car door and landing door finish: Stainless steel in hairline. Handrail: round handrail in stainless steel finish provided on rear wall of car. Alarm button in car operating panel. Automatic operation for car fan. Anti-nuisance (car call Protection) Cross Flow fan in car for ventilation Door open and door close buttons in car operating panel. Emergency light Full load by-pass Infrared screen for car door Fire Rated Doors: 2 Hours Overload function Phase failure and phase reversal protection. Attendant control. Car Position Indicator: To be provided by firm. Fireman control Nudging Service Voice Synthesizer.
SITC of Servostablizer and Allied works
Supply, installation, testing & commissioning of 15 KVA servo stabilizers including all allied electrical appurtenances viz. cabling, L.T control panels, changeovers etc. The stabilizer should have following specifications: a) Capacity: 15 KVA, 3-phase unbalanced type b) Input: (150-270) V AC P-N; (250-470) V AC P-P c) Output: 415 V 1% phase to phase d) Supply: 3 phase, 4 wires, 50Hz e) Operation: Automatic f) Duty cycle: Continuous g) Transformer windings: Copper wound on CRGO laminations as per IS specifications h) Cooling: Oil cooled i) Efficiency: Better than 98% at full load j) Overload capacity: 15% for continuous 4 hours k) Waveform distortions: Nil 1) High speed voltage correction: up to 5V to 20V per second m) Protections: Under voltage, Over voltage and Overload with time delay n) Other features: LED indicators, Digital AC ammeter, AC voltmeter, Frequency meters, Phase Sequence meters, Single phase preventer, and Stabilizer by-pass arrangement. The job also includes P/F of 100 A 4pole MCCB as incomer to servo stabilizer to be provided in CRC enclosure.
Supply, laying, testing and commissioning of 3.5 Core 35 Sq.mm aluminium armoured cable (XLPE) along with thimbles from main panel to changeover to lift panel. The job includes prior thimbling of the cables with heavy duty crimping tools followed by PVC tapping of the thimbled joints.
Change over panel comprising of 100A Al Bus Bar, 100A 4P, MCCB as incomer-2 No (for power supply & DG Set) & 63 A, 4P MCCB outgoing 1 No. (for lift), changeover switches, for DG & main to be supplied in a CRC panel.
Waterproofing of elevator pit: Providing & Laying of integral Cement based waterproofing (Injected type) treatment including preparation of surface and then applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS: 2645. After proper curing apply a second coat of cement slurry mixed with proprietary water proofing compound. The job includes finishing the surface with 20mm thick joint less cement mortar of mix 1:4.
Earthing: Providing and Laying of Copper (cu) strips and cu plate for proper earthing of all Electro-mechanical components carrying main current, including but not limited to the motor and electric panel. Use of bolts or screws and cu strips to establish grounding connections on each component. The job includes earth work by using labor for making a pit of suitable size for proper earthing and after that laying copper plate of minimum size 60cm width, 60 cm height and 3.15mm thickness and filling the pit with chemicals (chemical earthing). The earthing cu strip must have cross section not less than 24 mm^2. The job further includes laying of perforated conduit pipe from ground up to cu plate having funnel at top as per actual requirement at site & as per IS 3043 (1987)
Electric part
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC Insulated copper conductor (Havell/Polycab/ Fenolex/ Anchor/eq. standard make as desired by engineer Incharge) single core cable in surface/recessed medium class PVC conduit, with modular switch | Anchor roma plus/Legrand Mylinc FSSK NV/schneider Livia /ABB Tvisha make.), modular plate, sultable Gi box and earthing the point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without Independent Point switch etc.) with 1.5 sq. mm FRLS PVC Insulated copper conductor (Havell/salzer/ anchor/ equivalent as directed by engineer incharge.) single core cable in surface/ recessed PVC condult, as required.
Wiring for light/ power plug with 2x4 sq. mm + 1X 4 sq. mm earth wire, FRLS PVC insulated copper conductor (Havells/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer Incharge.) single core cable in surface/recessed medium class PVC conduit.
Supplying and fixing sultable size Gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, modular plate, suitable Gl box, connections etc. as required. Modular Switch & Socket:- (Anchor roma plus/Legrand Mylinc /SSK NV/schneider Leiva /ABB Tvisha make.)
Wiring for lighting circults/ 6-10 amp power plugwith 2X2.5 sq. mm FRLS PVC Insulated copper conductor (Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer Incharge) single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required
Supplying and fixing suitable size Gi box with modular plate and cover in front on surface or in recess, Including providing and fixing 2 nos. 3 pin 5/6 A. modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- (Anchor roma plus/Legrand Mylinc/SSK NV/schneider Livia /ABD Tvisha make.)
Supplying and fixing suitable size Gi box with modular plate and cover in front on surface or in recess, Including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying & fixing suitable size Gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B , "C" curve Including connections, painting etc as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC Insulated copper conductor (Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer Incharge.), single core cable in surface/recessed medium class PVC conduit as required.
2x 1.5 sq. mm + 1X1.5 sq. mm earth wire
2x6 sq.mm+1X6 sq. mm earth wire
2X 10 sq. mm +1X6 sq. mm earth wire
2X16 sq. mm + 1X6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit (Anchor/ Ravindra/ Eq, make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required with cement plaster,wall putty, paint complete.
Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supply Installation testing and commissioning of indicator of Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia/Crabtree athena make.)
Supply Installation testing and commissioning of AC/DC Bell Including Bell push and battries GM/ standard make
Supply installation testing and commissioning of 20 W LED Surface/recess, square or round Mounted light No luminary Fitting shape with minimum system lumen efficacy of 110 Im/W with Pressure Die cast Aluminium Heat Sink and P.F>0.95,THD<10%,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/ Trulux/Wipro make/sample to be approved before installation.
S/F testing and comm. Of 20 W + 4 ft. round mounted LED batten with powdered coated aluminum housing & integrated electronic driver with minimum system lumen efficacy of 100 lm/W with THD<10%. (commercial series) CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful cornmissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Trulux/Wipro make / sample to be approved before installation.
S/F testing and comm. Of 36 W+ 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with minimum system lumen efficacy of 100 lm/W with THD<10%. ( commercial series) CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V. The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved in-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/ Trulux/Wipro make / sample to be approved before installation
Supply Installation testing and commissioning of 30 W (2x2) LED Surface/recess, aquare or round Mounted No ghkiminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F>0.95, THD 10%, CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V The Fixture should have in-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NAB lab/ government of India. The Job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/TRulux
Supply Installation testing and comm. of flood light 100 W (warm, white), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07,, with high power LED's as light source with Built-in Potted IP67 electronic LED driver with APFC, lower THD, toughned glass and secondary lens, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per 15 15885 Part-2/Set 13, IEC60598-1. Preferred make: Philips/Havell /Wipro/Crompton make. the job also includes the angle iron stand of sultable size to be grouted in cement concrete with hold fastners complete job.
Supply installation testing and comm. Of 250mm sweep exhaust fan Shutter type/ steel body of havell /USHA/Crompton/equivalent make as directed by engineer incharge, Including making of space in wall/ window as ner site requirement and necessary connection
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan (USHA/havell Bajaj/Crompton/equivalent make as directed by engineer Incharge,) with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos, blades, 30 cm long down rod, 2 nos, canoples, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), Insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. the Job Includes the steel rod of suitable size and length to be installed at site
Supply and fixing of 6 amp/250 V AC fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc/SSK NV/schneider Zencelo/Havell Coral make
SITC of wall fan 400 mm sweep as approved by EIC,240v,50 Hz complete, etc, as required. Make(Usha Orient/Crompton/Havells
Supply fixing testing and comm. Of backlite holder/batten holder/angle holder/celling rose SSK/Anchor make incld PVC Block
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, legrand/Scheinider/Hager make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnections, powder painted Including earthing etc.as required. (But without MCB/RCCB/Isolator
6 way, Double door (18+4)
8 way, Double door (24+4)
Supplying and fixing of following rating, 240/415 V, 10 kA, "C" curve, miniature circult breaker suitable for whative load of following poles in the existing MCB DB complete with connections, testing and commissioning Jetc. as required, legrand/Schinider/LAT /equivalent make as directed by engineer Incharge.
6-32 Amp SP MCB
40-63amp DP MCB
40-63amp TP MCB
Supplying and fiing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply installation testing and commissioning of 200A 4P Bypass switch along with sheet steel Enclosure Legrand/Shinider/Semiens make.
Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet, floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears,, Aluminium Bus Bar of various ratings after taxing Derating factor into account, and other allied accessories etc. as required. As per approved design size may vary as per size requiremnt.
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with sultable size of PVC insulated copper conductor cable including earthing etc. as required.
Normal INCOMING:
A)400A 4P MCCB 36 KA including spreader links including spreader links, Icu=lcs-100% (Adjustable thermal and Adiustable marnetic release) Legrand/Shinider/Semiens make.
(b) 4 No. of Aluminium Bus Bar of 500 Amp.
c)Digital meters and plase indicators -1 set.
d) onload Change over switch 250 Amp for generator Front operated.
e) 4 No. of Aluminium Bus Bar of 400 Amp.
C)Digital meters and phase Indicators-1 set.
OUTGOING:
a)250A 4P MCCB 36 KA including spreader links including spreader links, Icu-lcs 100% (Adjustable thermal and Adiustable magnetic release) Lestrand/Shinider/Semiens make
b)160A 4P MCCB 36 KA including spreader links including spreader links, Icu=ics=100% (Adjustable thermal and No Adnotable maenetic release) Legrand/Shinider/Semlens make..
C)100A 4P MCCB 36 KA including spreader links including spreader links, icu=ics=100% (Adjustable thermal and Adisustable marnetic release) Legrand/Shinider/Semiens make.
100A TPN MCB 10 KA Legrand/Shinider/L&T/ABB make.
63A TPN MCB 10 KA Legrand/Shinider/L&T/ABB make.
40-63amp DP MCB 10 KA Legrand/Shinider/ABB/L&T sample to be approved before Installation
c) space for 20 way MCB's
(Ups Panel) Design. Fabrication, Supplying, installation, Testing and Commissioning of following panel, duly CFT manufactured from CPRI approved manufacturer, made out of 2mm thick M.5. sheet steel, floor/wall mounted, vermin and dust proof, Indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears,, Aluminiurn Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required. (As per approved desien.size may vary as per alte requirement)
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC Insulated copper conductor cable Including earthing etc. as required.
Normal INCOMING:
a)100A DP MCCB 25 KA Including spreader links including spreader links, icu-ics 100% (Adjustable thermal and Nos Adkatable magnetic release) Legrand/Shinider/Semiens make
b)2 No. of Aluminium Bus Bar of 200 Amp.
c)Digital meters and phase indicators-1 set.
OUTGOING:
c)63amp DP MCB 10 KA Legrand/Shinider/Siemens/L&T sample to be approved before installation…
c) space for 12 way MCB's
Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm job dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CRIRI (Central Power Research Institute), Govt of india for a peak short circuit withstanding capacity of 60 KA. Including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
Supplying and laying 25 mm x 5 mm G.l. strip at 0.50m. below ground level as strip earth electrode, including Mtr soldering etc as required.
S/L, testing and commissioning of PVC XLPE insulated alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminkum lugs of required size
a)185 sq.mm 3.5 core
b)95 sq.mm 3.5 core
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KVecade as required
( a) 4 X 185 sq. mm
(a) 4 X 95 sq. mm
5/L, testing and commissioning of PVC Copper cable 650 V/1100 V Grade as per 15 7098 (Part 1) 1988 with upto Date Amendments Havell/Eq, standard make as directed by engineer Incharge and making end termination with brass compressios gland and Conner lues of required size
a 35 sq.mm 3.5 core (un-armoured)
Earth work excavation for cable trench, 2 ft deep with an average breadth of 1.5ft and refilling of trench with excavated earth after laying of cable and ramming it properly excluding cost of cable the job also includes laying of warning tape.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
160 mm dia (OD-160 mm & ID-135 mm nominal)
Carrying out foundation of PCC type, cement concrete to be carried in 1:2:4 mix (1) cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)in foundation of DG set etc including form work ete as required the job also includes supply and carriage etc of the requsite material upto the site.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) including bends, Tees, cross members and allied accessories with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
200 mm width X 50 mm depth X 1.6 mm thickness
FIRE ALARM SYSTEM
Providing and fixing of 4.5kg. capacity I.S.1. Marked. (IS: 15683) Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS: 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge.
Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS: 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, elecuic and gases. 4 Kg. Capacity
Supply, installation, testing and commissioning of multi loop adress upto 260 modules conventional Fire Alarm Control Panel complete with Display, with sufficient panel enclosure and cabinet size. The panel shall be able to give location of all fire/fault conditions of addressabie units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, Loop cards, L CD unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The panel shall have a built in power supply and battery charger along with maintenance free battriest SMF Lead acid batteries capable of running for a minimum of 8 hours with battery charger complete as required. Panel shall be able to sense & indicate fire or fault
Supply, installation, testing and commissioning of Multi Criteria Smoke cum Heat Detector, optical type with blinking LED and being capable of being addressed electronically. Manual Addressing (Dip/Rotary Switches) not acceptable, with Mounting Base. Below false ceiling
Supply, installation, testing and commissioning of Double action manual pull station capable of being addressed electronically. Manual Addressing (Dip/Rotary Switches) not acceptable, complete as required.
(NS) Supply, installation, testing and commissioning of Fire Alarm Hodter (sound output of minimum 90 dB upto a distance of 30 meters), made Addressable with the help of Intelligent Addressable Signal Module, capable of being addressed electronically. Manual Addressing (Dip/Rotary Switches) not acceptable, with seperate power supply arrangement complete as required and suitable for wall/ceiling mounting.
Supply, installation, testing and commissioning of Fault isolator module complete as required for determining the short in a circuit and separating the segment having the short capable of being addressed electronically. Manual Addressing (Dip/Rotary Switches) not acceptable, complete as required.
Supply, Installation, testing and commissioning of Control Module complete as required for driving hooters, capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable.
Supply, installation, testing and commissioning of Multi Criteria Smoke cum Heat Detector, optical type with blinking LED and being capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, with Mounting Base. Below false celling
stage.html
html • 0.03 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.86 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.46 MB
Tendernotice_2.pdf
PDF • 1.47 MB
BOQ_990305.xls
BOQ • 0.38 MB
InnovatonHUB.pdf
PDF • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .