Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC | ₹15.3 L Quoted ₹16.4 L | L1 | Accepted-AOC BEING LOWEST AND REASONABLE |
| 2 | L2₹18.9 L+₹2.5 L (15.5%)Rejected-AOC | ₹18.9 L+₹2.5 L (15.5%) | L2 | Rejected-AOC BEING NOT LOWEST |
| 3 | L3₹24.0 L+₹7.6 L (46.7%)Rejected-AOC | ₹24.0 L+₹7.6 L (46.7%) | L3 | Rejected-AOC BEING NOT LOWEST |
| 4 | L4₹26.9 L+₹10.5 L (64.4%)Rejected-AOC | ₹26.9 L+₹10.5 L (64.4%) | L4 | Rejected-AOC BEING NOT LOWEST |
Tender Value
Refer Docs
Closing Date
7 May 2021, 6:00 pmClosed
HQ 135 WE
HQ 135 WE C/O 56 APO
REPAIR/ MAINT OF HT XLPE UG CABLE HT FEEDER PILLAR BOX AND CONNECTED WORKS UNDER GE (NORTH) AKHNOOR
2021_MES_435452_1
CWE/JA-03/2021-22
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
Class E Cat b ii
7 documents required · 7 mandatory
₹500
Yes
GE NORTH AKHNOOR C/O 56 APO
Exempted
17 Jul 2021
9 Apr 2021
10 May 2021
9 Apr 2021
7 May 2021
24 Apr 2021
9 Apr 2021 - 16 Apr 2021
Amount
Taking down burnt cable and Supply,fixing and testing of Aerial bunched cable (AB) HT 6.35/11 KV of size 3 core- X 95 sqmm+1-core X 70 sqmm with three power cores stranded compacted circular aluminium conductor screened with black extruded semiconducting compound, natural coloured XLPE insulated core screened with black extruded semi conducting compound and one layer of copper tape and covered with black extruded PVC ( core identification by colour tape marking red, yellow and blue with colour tape placed longitudinally under the copper tape) and one bare messenger wire shall be stranded non compacted circular aluminium alloy conductor, all as specified and directed. Make:- Havells, Gloster, Polycab, Grandlay Note:- The following hardware fittings and accessories shall be used to install, erect and join the AB cable :- (i) Suspension clamp with eye hook (ii) Suspension fittings and corresponding eye hook (iii) Dead eye fittinngs (iv) Nylon Tie (v) connectors Note: - Contractor has do all kind of tests for HT cable as per EI Rule before fixing on poles and cost of end jointing kits shall not be paid separetly and cost of the same included in rate quoted.
Taking down old /unsv earthing and Earthing complete with galvanized steel earth plate electrode 600mm x600mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground leel, connecting to the Galvanised earthing lead strip 32x6mm size, by means of bolts, nuts, heck nuts and washers of galvanized iron and earth lead protected by provision of GI medium grade pipe 65mm bore incl provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 40mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs, all as per electrical plate No 5 of SSR-1991 Part I and connected to earth test point, all as specified or indicated incl testing on completion. Note:- The required resistance of Earthing shall be 2 ohm or less than 2 ohm, If not found to the required resisstance, the contractor has to reorganise for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance.
Supply and fixing in replacement female contact spring loaded having brass contacts suitable for GOD 200A for working pressure 11000 Volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation, all as required at site or directed by Engr In charge.
Supply and fixing in replacement male contact with arching horn having brass contacts suitable for GOD 200A for working pressure 11000 Volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation, all as required at site or directed by Engr In charge.
Supply and fixing in replacement copper braided belt 400mm long with MS carrier suitable for GOD 200A for working pressure 11000 Volts, galvanised iron bolts, nuts and washers for fixing all as required at site or directed by Engr In charge.
M&L jointing HT XLPE heat shrinkable type incl termination joint for 3 Core on existing / new HT cable and connecting to GOD /Pole with proper thimbling all as specified for following sizes :- Make: - Denson/ M'Seal/ Raychem (a) 50 to 95 Sqmm
(b) All as per Srl item No. 6.00 (a) but 120 to 185 Sqmm Make: - Denson/ M'Seal/ Raychem
Material and labour for pole painting of 9 mtr to 11mtr steel tubular pole of any type/size/ length and removing from existing pole painting by using wire brush and using with emary paper and cleaning with chemical agents after cleaning of steel tubular pole and GI brackets and cross arms in two coats of red oxide primar and two coats of silver oil paint upto smooth finishining to satisfactorly by engr-in-charge and painting work one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint carryout at any height, including safety eqpts & tools will be own arrangement and complete all as specified and directed. Note:- Cost of painting material is deemed to be included in quoted rate only. Make of paint Asian, Berger, Nerolac
M&L for lightening arrestor station type, complete with all fittings, transmission class, discharge capacity HT 11 KV rupturing capacity 65KA suitable for, complete all as specified and directed. Make:- BHEL, Jaipuria, Alstom
Taking down old unsv operating switch gear device and Supply and fixing 11KV, 630A suitable for outdoor type in CRCA powder coated steel enclosure, 3.15 mm thick and the main frame is welded in steel structures fabricated load break switche Panel protection of various transformers <400KVA. The switch shall use low pressure SF6 gas for current interruption and shall require no maintenance. Leakage rate shall not be over 0.1% per year, for life span of at least 30 years.It shall have three positions (closed, open and earthed). The switching device shall be suitable for three-phase systems operating at 11/12 kV and 50/60 Hz. The rated voltage shall be at least 12 kV. The short-time with stand current shall be 25 kA26.3 - 1 s / 12 kV. LBS Make ABB, Schneider, SIEMENS.
LBS panel should be provided with fuse trip assembly and HRC fuses of appropriate rating for protection of transformers. The operating mechanism should have following functions. (a) Switch function: independent-operation closing by lever. Operating energy is provided by a compressed spring which, when released, causes the contacts to close. independent-operation opening by push-button (O) or trip units. Earthing-switch function: Independent-operation closing and opening by lever. Operating energy is provided by a compressed spring which, when released, causes the contacts to open or close (c). Opening releases- shunt trip Switch: The switch shall use low pressure SF6 gas for current interruption and shall require no maintenance. The switch enclosure shall be mounted horizontally within the cubicle and the position of the main and earthing contacts shall be clearly visible from the front of the cubicle. The position indicator shall be placed directly on the contact-operating shaft. The switch enclosures shall be made of cast epoxy resin. The mechanical endurance of the switch operating mechanisms shall ensure at least 1000 operations class M1.
LBS Panel: Medium voltage switchgear shall completely with the latest issues of the IEC recommendations: IEC 62271-200. Switchgear shall be Free standing, Floor mounted, metal enclosed suitable for Outdoor use. The frame of individual vertical panels shall be minimum 2 mm CRCA. Degree of protection shall not be less than IP55. All hardware shall be corrosion resistant. Busbar shall be high conductivity aluminum/Copper supported on insulators made of nonhygroscopic, non-inflammable material. Panel shall be provided with earth busbar of copper of suitable size rated for short time rating of switch board and Provision for receiving incoming or outgoing power cable through rear bottom entry. All metal surface shall be thoroughly cleaned, processed under 7 tank treatment. Make of Panel Schneider/ABB/Siemens/dvepl/Panel shall be powder coated with final colour shade RAL 7032/eqvt shade. Earthing of the Power Circuit: Cable earthing shall be carried out by an earthing switch with a short-circuit making capacity, in accordance with IEC 62271-102 recommendations. It shall be possible to operate the earthing switch when the switch or disconnector is open. Mechanical interlocking systems (rotating switch with 3 positions )shall be provided to prevent incorrect operations such as the closing of the earthing switch with the switch or disconnector in closed position Control Wiring: The wiring shall be carried out using multi-strand copper conductor super flexible PVC insulated wires of 650/1100V Grade for AC Power. Control terminals shall be screw type for auxiliary wiring Minimum 10% spare terminals shall be provided for control circuit.
Taking down and M&L for steel tubular swaged pole type 410 SP-55 (11metre long) with 300 mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5M from ground level/coping, complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, all as specified.
M&L PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in pole coping, complete all as specified and directed including necessary from work.
Supply and fixing vinyl display board frame size 6'x4' showing schematic diagram of electric/water supply distribution network as sketch provided to be fixed on walls in installation, all as specified and directed by Engr-in-charge.
Taking out carefully stone aggrgrate of any size from the bay/yard without damaging the equipments,cable or any parts of 33KV Grid bay,removing of ducts,sand/grass etc, spreading and levelling of finished gravel uniformally in layers not exc 15cm thick, rammed to a true surface, all as specified and directed.
M&L for sieving out graded coarse aggrgrate and taking out sand dust/gravel of size less than 25 mm of nominal size and Supply filling and laying coarse aggregrate normal size 40mm at 33 KV Grid bay/yard, deposted spread and levelled in layers not exc 100mm thick, rammed to a true surface, all as specified and directed.
Material and labour for retro reflective installation sign board size 6ft x 4ft fabricated out of 1.6mm MS sheet frame welded/riveted with stainless steel pipe finished in square of size 25mmx25mm at 2.5m height from ground level on stainless steel finished pipe of size 50mm fixed with PCC 1:2:4 Type B-1 of block size 45cmx45cmx60cm.The board shall be painted in stove enamelled paint and the front and back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The writting matter will be in English language on both sides with reflective adhesive painter tape, all as specified and directed.
Supply and fixing aluminium conductor screened with extruded semi conducting compound XLPE insulated of size 50 sqmm 11 KV single core cut to size all as required for jumpers of HT lines Incl required size aluminium thimbles at both ends for connection, all as directed by Engr- in-Charge. Make of cable Havells, Gloster, Grandlay
Supply and fixing aluminium conductor screened with extruded semi conducting compound XLPE insulated of size 70 sqmm 11 KV single core cut to size all as required for jumpers of HT lines Incl required size aluminium thimbles at both ends for connection, all as directed by Engr-in-Charge. Make of cable Havells, Gloster, Grandlay
Taking down old/unsv and M&L ACSR conductor any size to over head lines , stretching properly to achieve proper sag including binding to insulators using GI/alumn binding wire all as required at site or directed by Engr- In - Charge. Make of conductor:- Alind, Bharat conductor, Nicco
Restringing of over head line ACSR of any size and upto 5 wires in a span with GI earth wire of 4 mm dia of span length 30 to 60 m to permissiable sag incl winding with Aluminium conductor, jamppers etc. and triming of branches of tree beside the span all as directed.
Supply, laying, jointing and testing underground cables XLPE insulated screened PVC bedded galvanised steel strips armoured electric power cables (heavy duty) with aluminium conductor HT 11000 volts grade and 95 sqmm 3 core cross sectional area conforming to latest IS and ISI marked, complete all as specified and directed by Engr-in-charge. Make:- Havells, Gloster, Grandlay
Supply, laying, jointing and testing underground cables XLPE insulated screened PVC bedded galvanised steel strips armoured electric power cables (heavy duty) with aluminium conductor HT 11000 volts grade and 120 sqmm 3 core cross sectional area conforming to latest IS and ISI marked, complete all as specified and directed by Engr-in-charge. Make:- Havells, Gloster, Grandlay
Excavation in trenches n.exc 1.5m wide and n. exc. 1.5m in depth for foundation of pole and laying of HT cable as in soft/loose soil and getting out, complete all as specified and directed.
Returining filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in soft/loose soil, complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
M & L for brick sub class 'B' 230mm x 115mm x 75mm and laid in trenches as in protection of UG cable, complete all as specified and directed.
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete, all as specified in SSR Part-I and as directed.
Surface excavation not exc 30cm deep and average 15 cm deep and getting out in soft/loose soil, complete all as specified and directed Engr-in-charge.
Supply and fixing glow sign board made of sheeting having lighting arrangement of superior quality of size 5'x2' showing installation Nomenclature as approved marked, all as specified and directed. Note: Installation line diagram to be enfaced will be approved by AGE E/M and no extra will be paid of any addition and alteration of words or marking of colours.
M&L for galvanised cross arms, bracings, supports, clamps, angles, hellow bars square/round, flat irons etc and back plates fabricated in structural steel sections including nuts, bolts, washers, welding, bending, fabrication, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat one undre coat and one finishing coat of paint and including removing old unserviceable item, complete all as specified and directed.
Broken stone or boulder hard core of guage n exc 40 mm, deposited, spread and levelled in layer not exc. 15cm thick rammed to a true surface complete all as specified and directed by Engr-in-charge.
Material and labour for scraping of old paint of 33/11KV substation (02 Nos bay) steel structure posts by using emery/iron brush and painting with two coats of aluminium to complete 33/11KV substation including entire steel structure upto height of mtr,spray painting of 02 Nos 33/11KV, 3.15MVA transformer as per existing incl aluminium painting of XPM jalli around transformer, spray painting to CT/PT units, all as specified and directed. Note:- Contractor has to take complete shut down and contractor shall not be provided working periods more than 02 Hrs/day.
Material and labour for tree branches/vegitation cutting around the 2/4 poles tructure and HT lines and installations from line conductor to tree distance up to 4 mtrs and cutted wood pieces/vegitation materials disposal upto distance not exc 100 mtr at defence land location where as directed and including providing safety eqpts & cutting tools,ladders etc will be own arrangement by the contractor and complete all as specified and directed.Note:- (1) Safety measures will be fully responsible by tenderer. (2) During tree /branches/vegitation cutting any damages on OH lines/installation should be reuniform responsible fully by the tenderer with out any extracost. (3) Approximately distance covered 2 mtr both side for the HT/LT lines 100 mts & at installation not exc 100mtr x100 mtr measured as a one Job only.
Material and labour for 9 mtr to11mtr PCC pole painting of any type /size/length and removing from existing pole painting by using wire brush and cleaning with with cotton waste after cleaning of PCC pole in two coats water proof cement based paint in two coats and GI brackets and cross arms in two coats of red oxide primar and two coats of silver oil paint upto smooth finishining to satisfactorly by engr-in-charge and one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint, painting work carryout at any height, including safety eqpts & tools will be own arrangement and complete all as specified and directed.
Material and labour painting of 4 pole structure of any type/size/length and removing from existing pole painting by using wire brush and using with emary paper and cleaning with chemical agents after cleaning of steel tubular pole and GI brackets and cross arms in two coats of red oxide primer and two coats of silver oil painting upto smooth finishining and painting to satisfactorly by engr-in-charge and painting work carryout at any height and including marking of pole numers as directed and safety eqpts & tools will be own arrangement and complete all as specified and directed. Note:- Cost of painting material is deemed to be included in quoted rate only.
All as per item No.36.00 but 2 pole structure, complete all as specified and directed.
M/S SHREE KRISHANA ENERPRISES
Jiwan Singh
M/S PAWAN KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .