Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹15.6 Cr
EMD Value
₹31.2 L
Closing Date
4 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
WORKS
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'Total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of IRGCC 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. NOTE: FOR DETAILS PLEASE REFER TENDER DOCUMENT.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. (b) (i)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for (b) (i): Separate completed works of minimum required values for each component shall also be considered for fulfillment of technical eligibility criteria. (b) (ii) In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (iii) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 (a) (ii) of Part-II of GCC or through subcontractor fulfilling the requirements as per clause 7 of Part-II of GCC or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of Part-II of GCC, with prior approval of Chief Engineer in writing. NOTE: FOR DETAILS PLEASE REFER TENDER DOCUMENT.
3 conditions
CHECKLIST OF ITEMS TO BE COMPLIED BY THE TENDERERS
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
REPLACEMENT OF OLD RRI TO EI AT LILUAH STATION OF HWH-BWN MAIN LINE.
SGW-272-252-T1-58~ER
SGW-272-252-T1-58
Open
Works - General
15 Months
Kolkata, West Bengal
₹0
₹31.2 L
4 Nov 2026
30 Sept 2026
21 Oct 2026
334 items across 3 schedules · ₹15,91,90,206.6 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | DESIGN , SUPPLY, COMMISSIONING OF HOT STAND BY ELECTRONIC INTERLOCKING SYSTEM COMPLETE AS PER RDSO SPE. NO. RDSO/SPN/192/2005 VER.1.0 OR LATEST AMENDMENT. Detailed description of EI is given in Tender Document. | Per Functional Vital Bit | 548.00 | 72,036 | 3,94,75,728 |
| 2 | Installation, wiring, testing (FAT & SAT) and commissioning of EI System with 'Hot Standby' architecture as supplied above item. It includes transportation of material from consignee's depot to the site, erection and grouting of EI Relay Racks, fixing and wiring of all the interfacing relays (Vital & Non-Vital) , installation and wiring of Microprocessor equipments, interface equipments, power supply equipments and all other associated accessories to make complete EI system to be functional. Note: (i) Technical Requirements are attached with tender document (ii) Contractor has to arrange simulator/ simulation testing panel for testing and commissioning by Selection Table and Square Sheet for each Signalling function.(iii) Installation, wiring, testing and commissioning of EI system will be done by OEM after following all the guidelines/ directives issued by RDSO from time to time. | Station | 1.00 | 5,96,262 | 5,96,262 |
| 3 | Modification /Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines /TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and c i r c u i t d i a g r a m s . A l l the material (Interface cards/re1ays/wiring material/ c o n n e c t o r s /fuses/communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, I n t e r f a c e Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings /circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied.Alteration involving modification in up to 10 routes. | Per Alteration | 2.00 | 17,44,012 | 34,88,024 |
| 4 | "Supply of maintainer's furniture of Godrej make or superior and each set consist of(i) executive revolving bearing series low back-floating chair with normal arms cushioned chair-01 Nos. (ii) Executive table size 1650x900x728 mm with 3 drawers one side locker- 01 no. (iii) visitor chair seat & back cushion with high densityfoam with plastic PVC handle capsule type painted back- 03 nos."Inspection : Consignee | Numbers | 2.00 | 23,528 | 47,056 |
| 5 | Supply of Micro Processor based Data Logger System with 1024 digital and 32 analog inputs with DOT Matrix Printer,80 COL as per RDSO Spec. No. IRS (S) 99/2006 with Amdt. 3.0 or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply up to Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD, IPS, UFSBI, BI, interlinking and networking of Data logger. It also includes supply of leased line MODEM and other interfacing cards, if required for networking of Data logger. This also includes supply of one no. composite computer and printer table (Godrej work station table or similar) f o r keeping processor module workstation and one number Godrej operator chair Model PCH7001 or similar. Note: (1) Total numbers of relays and other signalling functions/ gears required to be wired as per list circulated v i d e R D S O Letter No.STS/E/Data logger dtd.12.09. 2011 or l a t e s t guidelines o f Railway Board/ RDSO/ Zonal Railway. (2) Exceptional reports are to be generated by a computer connected to datalogger at the station and at a central location in C o n t r o l Room. Datalogger software should b e able to generate exceptional reports for maintenance, safety and operations as per latest guidelines of Railway Board/RDSO/ Zonal Railway. Datalogger to be installed at Site by OEM. Manufacturing date of datalogger/ RTU and printer should be of current year at the time of supply. Inspection: RDSO for Datalogger. Inspection: Consignee for Printer & other items. | Numbers | 1.00 | 4,96,233 | 4,96,233 |
| 6 | SUPPLY OF DUAL LEASED MODEM INTERNAL CARD TO FIT IN CENTRAL PROCESSING UNIT RACK FOR NETWORKING OF DATA LOGGER SYSTEM OF OTHER STATIONS. EACH SET SHALL COMPRISE OF ONE PAIR OF MODEM AND SHALL HAVE DATA COMPATIABILITY 1TUV 21, V2, V22 BITS, V23V23A, B V25 BITS, V32, V32 BITS V42, V42 BITS, SUITABLE TO WORK IN EITHER OFC MEDIA OR MICROWAVE OR QUAD CABLE. INSPECTION: RDSO. | Set | 1.00 | 24,433 | 24,433 |
| 7 | INSTALLATION, TESTING AND COMMISSIONING OF DATA LOGGER WITH ACCESSORIES, POWER SUPPLY ARRANGEMENT COMPLETE. NOTE:- DATA LOGGER TO BE INSTALLED AT SITE BY THE ENGINEER OF THE ORIGINAL MANUFACTURER OF THE EQUIPMENT FROM WHERE EQUIPMENT IS BEING PROCURED BY THE CONTRACTOR. ALL DATA LOGGERS TO BE FINALLY NETWORKED TO CENTRAL MONITORING UNIT THROUGH MODEM. EXCEPTIONAL REPORTS ARE TO BE GENERATED BY A COMPUTER CONNECTED TO DATA LOGGER AT THE STATION AND AT A CENTRAL LOCATION ALSO IN CASE OF NETWORKED DATA LOGGERS. | Numbers | 1.00 | 51,876 | 51,876 |
| 8 | "Supply of Failure Analysis System (FAS) with Fault Analysis Software (Datalogger Analyser) consisting of a PC (Make- Dell /HP or Equivalent) as per Technical Specifications. The specification of FAS should be got approved from the Engineer in charge before supply. Note: The minimum specification should be as given core i7 or higher version processor (speed 3.2 GHZ, 4 MB cache memory),8 GB RAM,2TB SDD or Higher, Two front and four rear USB port,1 Serial & 1 Parallel Port,1VGA Port,21'' LED Colour Monitor (HP/DELL or equivalent) or Bigger Size, Sound Card with Speaker,1000 MBPS Network Card,Keyboard,Optical Mouse,10/100 T Lan Card, Combo Drive,Microsoft Windows 10 Licensed OS with Licensed (Antivirus,MS Office etc.),UPS 750 VA with 30 Minutes minimum backup(APC/Microtekor Equivalent),LaserJet Printer(HP Pro 1108 or superior).Inspection: Consignee." | Numbers | 2.00 | 1,16,554 | 2,33,108 |
| 9 | "Relay fail safe electronic time delay device with fixed timing (0 -120) seconds and conforming to RDSO Specn. No.IRS: 5-61/2000 with Amnd.2 and IRS: S-34 & S-23 with Amdt. up to date or latest mounted on Q-series relay base & covered complete with connectors, retaining clip etc. The interlocking code for this unit shall be ""AFGKY"".Inspection authority:- RDSO" | Numbers | 20.00 | 1,591 | 31,820 |
| 10 | "Relay fail safe electronic time delay device with fixed timing (0 @45<41@ seconds and conforming to RDSO Specn. No.IRS: S-6 1/2000 with Amnd.1 or latest mounted on Q-series relay base & covered complete with connectors, retaining clip etc. The interlocking code for this unit shall be ""AFHKY"".Inspection authority:- RDSO" | Numbers | 20.00 | 2,118 | 42,360 |
| 11 | Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS: S-34 & S-23 with Amdt. upto date or latest. The interlocking code for this unit shall be "ABCDE". Inspection authority:- RDSO | Numbers | 250.00 | 3,769 | 9,42,250 |
| 12 | Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No. IRS: 5-34 & S-23with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABDEG". Inspection authority:- RDSO | Numbers | 30.00 | 5,718 | 1,71,540 |
| 13 | Q-Series LED ECR (Universal Type i.e. QECX- 61), 4F/4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS:94 1A STS/E/RELAYS/AC LIT LED SIGNAL/09- 2002, Amdt. -1 and RDSO Specn.No.IRS: S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABDHK".Inspection authority:- RDSO | Numbers | 100.00 | 4,912 | 4,91,200 |
| 14 | "Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS: 5@45"44@ S-23 and 5-60 with amdt. upto date as applicable or latest. The interlocking code for this unit shall be ""ABDFH"".Inspection authority:- RDSO" | Numbers | 150.00 | 4,007 | 6,01,050 |
| 15 | "Q-Series Neutral Line Relay(QSPA1 Type), 24V DC,8F/4B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-933A and RDSO Specn.No.IRS:S@45"44@ 5- 23 & S 60 with amdt. upto date as applicable or latest. The interlocking code for this unit shall be ""ABDEJ"".Inspection authority:- RDSO" | Numbers | 60.00 | 5,230 | 3,13,800 |
| 16 | Contactor Unit (QBCA 1 Type), 24 V DC, 2F(HD)/ 4B or 2F(HD)2F-4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS: 5-34 & S-23 with amdt. upto date as applicable or latest. The interlocking code for this unit shall be "BCEJK" o r "DEHJX". Inspection authority:- RDSO | Numbers | 30.00 | 6,842 | 2,05,260 |
| 17 | Screwless Cage Clamp Connection, 2 conductor through Terminal block suitable for wire 0.2 mm2 - 16 mm2 , 800V / 76A, Mounting : Din 35 Rail, Front Entry , Colour in Grey Similar to Wago Part no. 280-901 | Numbers | 200.00 | 56 | 11,200 |
| 18 | INSTALLATION ,WIRING AND FIXING OF RELAY RACK AS PER DRG.NO. S&T/C- 20/2001 . WITH LATEST. SUPPLY & FIXING OF TRANSFORMERS ,FUSES WITH BASE, DIODES, RESISTANCES, CONDENSORS, TERMINAL STRIPS/TAG BLOCKS, BUS BARS & OTHER EQUIPMENTS REQUIRED FOR THE APPROVED SYSTEM DESIGN COMPLETE WITH SCAFFOLDING MATERIALS & REQUIRED HARDWARE & ERECTION MATERIALS. PVC WIRE (RDSO SPEC. NO. IRS-S-76/89) , AMD-2 OR LATSET) FOR WIRING OF RELAY RACK SHALL BE SUPPLIED BY THE CONTRACTOR, DULY INSPECTED BY RDSO. THIS INCLUDES STATUS OF RELAY TO BE INDICATED THROUFH LED INDICATION AT THE TOP OF THE RELAY RACK AND IN THIS CONNECTION ALL THE REQUIRED MATERIALS TO BE SUPPLIED BY THE CONTRACTOR . RACK TO BE FIXED ON RUBBER PAD. SUPPLY PART | Numbers | 4.00 | 25,535 | 1,02,140 |
| 19 | INSTALLATION ,WIRING AND FIXING OF RELAY RACK AS PER DRG.NO. S&T/C- 20/2001 . WITH LATEST. SUPPLY & FIXING OF TRANSFORMERS ,FUSES WITH BASE, DIODES, RESISTANCES, CONDENSORS, TERMINAL STRIPS/TAG BLOCKS, BUS BARS & OTHER EQUIPMENTS REQUIRED FOR THE APPROVED SYSTEM DESIGN COMPLETE WITH SCAFFOLDING MATERIALS & REQUIRED HARDWARE & ERECTION MATERIALS. PVC WIRE (RDSO SPEC. NO. IRS-S-76/89) , AMD-2 OR LATSET) FOR WIRING OF RELAY RACK SHALL BE SUPPLIED BY THE CONTRACTOR, DULY INSPECTED BY RDSO. THIS INCLUDES STATUS OF RELAY TO BE INDICATED THROUFH LED INDICATION AT THE TOP OF THE RELAY RACK AND IN THIS CONNECTION ALL THE REQUIRED MATERIALS TO BE SUPPLIED BY THE CONTRACTOR . RACK TO BE FIXED ON RUBBER PAD. INSTALLATION PART | Numbers | 4.00 | 83,032 | 3,32,128 |
| 20 | Installation of cable termination rack with scaffolding materials ladder for supporting outdoor cable; wire guide complete with other necessary hardware as per requirements of rly. & erection materials. Wires to be procured from RDSO's approved firm only. This includes supply of cable termination rack as per DRG.NO. S&T/C- 17/2001 OR latest with screw less disconnect type connectors (Wago/ Phoenix/Similar) , scaffolding materials, ladder for supporting outdoor cable, wire guide, NDT fuse complete with other necessary hardware as per requirements of railway & erection materials. Supply. Inspection: (i) RITES if value of item in work more than 5 lakhs. (ii)Consignee if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | Numbers | 6.00 | 44,924 | 2,69,544 |
| 21 | Installation of cable termination rack with scaffolding materials ladder for supporting outdoor cable; wire guide complete with other necessary hardware as per requirements of rly. & erection materials. Wires to be procured from RDSO's approved firm only. This includes execution of cable termination rack as per DRG.NO. S&T/C- 17/2001 OR latest with screw less disconnect type connectors (Wago/ Phoenix/Similar) , scaffolding materials, ladder for supporting outdoor cable, wire guide, NDT fuse complete with other necessary hardware as per requirements of railway & erection materials. Execution. | Numbers | 6.00 | 5,790 | 34,740 |
| 22 | SUPPLY OF ARA TERMINAL PBT 6-WAY ,25mm as per spec. no. IRS:S-75 Drg. No. SA:23756A(IRS) or latest OF EACH CORE OF SIGNALLING CABLE ON EXISTING / NEWLY INSTALLED TERMINAL BOARD OF RELAY ROOM. FIXING MATERIALS SUPPLIED BY THE CONTRACTOR. | Numbers | 1000.00 | 485 | 4,85,000 |
| 23 | ' SUPPLY OF FUSE BLOCK (PBT) TO SPEC.NO. IRS-S-75/2006 (REV-2) OR LATEST. DRG. NO. SA-23748 WITH FUSE ( FOR DC TRACK CIRCUIT) INSERTS CARTRIDGE, NON DETORIORATING TYPE TO SPEC. IRS-S-78/92 WITH LATEST AMENDMENT TO BE MOUNTED INSIDE THE LOCATION BOX ON HYLUM SHEET. INSPECTION : BY RDSO FUSE, NON DETERIORATING (2A/6A/10A/16A) TYPE CYLINDRICAL (IRS-S-78/92) QTY. AS PER SITE REQUIRMENT. | Numbers | 150.00 | 61 | 9,150 |
| 24 | ' SUPPLY OF FUSE BLOCK (PBT) TO SPEC.NO. IRS-S-75/2006 (REV-2) OR LATEST. DRG. NO. SA-23748 WITH FUSE ( FOR DC TRACK CIRCUIT) INSERTS CARTRIDGE, NON DETORIORATING TYPE TO SPEC. IRS-S-78/92 WITH LATEST AMENDMENT TO BE MOUNTED INSIDE THE LOCATION BOX ON HYLUM SHEET. INSPECTION : BY RDSO FUSE BASE | Numbers | 150.00 | 178 | 26,700 |
| 25 | Supply of PVC insulated Railway Signalling multi-core Indoor Cable 60 core (0.6mm dia) conforming to IRS:76/89(Amd3) or latestInspection : Consignee | Kilometre | 1.00 | 1,51,032 | 1,51,032 |
| 26 | TERMINATION OF CABLE ON CT RACK IN RELAY ROOM/ RELAY HUT/ LOCATION BOX WITH PROPER LUGS AS PER DIAGRAM AND DRESSING WITH THREAD (BALL TWINE) DISTRIBUTING AND TERMINATING ON THE ARA TERMINALS/ 8 WAY TERMINAL STRIPS OR FUSE OR ANY OTHER EQUIPMENT AS INSTRUCTED BY SITE ENGINEER INCLUDING EARTHING OF CABLE ARMOURS WITH SUITABLE ALUMINIUM CLAMPS OF 20 MM X 5 MM INTER CONNECTED BY 7/16 SWG GI WIRE (DUPLICATE) AFTER PROPER SOLDERING WITH LUGS ON MAIN EARTH ELECTRODE OUTSIDE THE RELAY ROOM. TESTING OF CABLE END TO END FOR INSULATION, CONTINUITY AND PROVISION OF CABLE CONDUCTOR, MARKERS, SLEEVES, LUGS ARE PART OF THIS ITEM. CIRCUIT/CABLE/WIRE IDENTIFICATION SHALL BE PAINTED 8 MM SIZE APPROX. ON TERMINAL BOARD/ BACKELITE SHEET JUST BELOW OR ABOVE THE CABLE WIRE. | Per Conductor | 10000.00 | 9 | 90,000 |
| 27 | "Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer- in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3)" | Numbers | 1000.00 | 55 | 55,000 |
| 28 | Supply of End plate 2.5mm/0.091 in thick as per site requirement. | Numbers | 100.00 | 10 | 1,000 |
| 29 | Supply of End Stopper 10mm/0.0394 in width as per site requirement. | Numbers | 100.00 | 10 | 1,000 |
| 30 | Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un- slotted type as per site requirement. | Numbers | 50.00 | 109 | 5,450 |
| 31 | CARRYING OUT RELAY ALTERATION TO THE EXISTING RELAY WIRING AT RELAY RACK/LOCATION BOX AS PER APPROVED CIRCUIT DIAGRAM.THESE WORKS INCLUDES THE RELEASING OF EXISTING UNUSED WIRES AND WIRING THE RELAY USING 16/0.2MM COPPER WIRE AS PEE RDSO SPEC.WIRE TO BE PEOCURED FROM RDSO APPROVED SOURCES ONLY AND INSPECTION BY CONSIGNEE. NOTE: WIRE TO BE PEOCURED FROM RDSO APPROVED SOURCES ONLY. ALL REQUIRED MATERIALS LIKE WIRE, SOLDERING MATERIALS, PAINT ETC. TO BE SUPPLIED BY THE CONTRACTOR FOR EXECUTION OF THE WORK. | Per Relay | 100.00 | 270 | 27,000 |
| 32 | Dismantling of Microlock rack, relay rack, cable termination rack of existing relay room and equipment of existing panel room & power room etc. | Numbers | 15.00 | 6,621 | 99,315 |
| 33 | Supply, Installation and Commissioning of SMPS based Integrated power supply (IPS) system as per RDSO Spec. No. RDSO/ SPN/165/2012 (Ver.3. 0) with latest amendment if any and also as per Sketch No. SDO/IPS/ SMPS/6L RE-002 or Latest along with 300AH Low maintenance lead acid cell as per E. Rly. Practice. (Item shall be procured through Store) Inspection: RDSO | Numbers | 2.00 | 11,83,104 | 23,66,208 |
| 34 | Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. (2V, 80AH) | Numbers | 250.00 | 3,574 | 8,93,500 |
| 35 | Charging of lead acid cell (Secondary cell) of various capacities as per Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity acid should be approved type duly inspected by consignee. This includes installation and commissioning of battery in circuit. Battery to be kept on wooden rack. (2V, 80AH) | Numbers | 250.00 | 367 | 91,750 |
| 36 | Supply and erection of a mast / high mast suitable for ESE technology based lightning protection installation, mechanically robust good corrosion and fire resistance,5 mtr. (including 2 mtr FRP) long GI/MS painted along with guying kit foundation and other accessories required for installation of mast. | Numbers | 1.00 | 7,170 | 7,170 |
| 37 | Supply and laying of 70 sq.mm PVC insulated flexible tinned electrolytic copper down conductor placed in a metallic / PVC protective covering wherever exposed to human intervention including saddles and all accessories as required. Inspection: RDSO | Metre | 50.00 | 1,362 | 68,100 |
| 38 | Supply & laying of 25x3 mm pure electrolytic copper tape through suitable CLASS-'B' GI pipe for loop Earthing and bonding as per site requirement. Supply material inspection by consignee. | Metre | 50.00 | 1,377 | 68,850 |
| 39 | Installation of class A device on the top of the building: the device shall be installed at a height of about of about 3 mtrs. From the roof of the building using a GI mast. The device shall be connected to earth pit using the copper tape of 25 mm x 2 mm or better. This copper tape shall be run firmly along the side of the mast with help of spacers. It shall also be ensured that this down conductor shall not touch the building throughout. The down conductor should be connected to earth electrode using exothermic welding or better. A counter shall be installed at a appropriate place to count number of occurrences. | Numbers | 1.00 | 18,244 | 18,244 |
| 40 | SUPPLY & INSTALLATION OF LIGHTNING AND SURGE PROTECTION DEVICE BOTH 'B' & CLASS 'C' BETWEEN LINE AND NEUTRAL AND NEUTRAL AND EARTH OF APPROVED TYPE. INSPECTION: BY CONSIGNEE. | Numbers | 2.00 | 24,449 | 48,898 |
| 41 | Supply of Point JB fitted with 18 nos. 1- way terminal block confirming to IRS-S- 75/91 (AMD-2) OR LATEST, DRG. NO. SA- 2374 1A with 3 no. of 40 mm bore G I PIPE 600 mm long as per DRG. NO. SGW/MGS/ PT4/91 fixed on hylum sheet with U channel (75x40x1500) mm for fixing ARA terminal to be procured from RDSO approved sources. Inspection- Consignee.Supply Portion. Inspection: Consignee | Numbers | 30.00 | 4,140 | 1,24,200 |
| 42 | SUPPLY OF GROUND CONNECTIONS (BG) THREADED TYPE FOR IRS POINT MACHINE COMPLETELY SET AS PER DRG. NO. BS/ 29/ 722, 724, 725, 726A, 726B, 726C, 726D, 727 SUITABLE FOR IRS TYPE POINT MACHINE WITH INSULATION OF STRETCHER BAR, SWITCH EXTENSION PIECE ETC. AND SUPPLY OF ALL OTHER ACCESSORIES REQUIRED FOR INSTALLATION TO BE DONE BY CONTRACTOR. INSPECTION: BY CONSIGNEE. FOR IRS POINT MACHINE (SPEC.IRS-24/90) : TURNOUT | Numbers | 15.00 | 6,716 | 1,00,740 |
| 43 | SUPPLY OF COMPLETE GROUND FITTINGS OF DOUBLE SLIP POINTS OF ELECTRICAL POINT MACHINE AS PER RDSO DRG. NO. 3/2005 OR LATEST SUITABLE FOR IRS/SIEMENS POINT MACHINE. NOTE: GROUND FITTING WILL BE SUPPLIED AS PER SITE REQUIREMENT. | Numbers | 10.00 | 16,005 | 1,60,050 |
| 44 | Supply of SINGLE SLIP ground connections AS PER RDSO DRG. S-3153 OR LATESTAS PER SITE REQUIREMENT Inspection: Consignee | Numbers | 6.00 | 8,473 | 50,838 |
| 45 | Supply of Electric Point machine IRS type 220 mm throw, high thrust (AC immunity 160V AC), non trailable to operate on 110V, DC complete with Lock and Detector slides, Cable Termination Box and clamp lock 60 Kg. confirming to IRS: S 24/2002 & Assy. Drg. No. RDSO-S /11000 & For Motor IRS: S 37/82. (items to be procured through stores)Inspection: RDSO | Numbers | 10.00 | 1,31,165 | 13,11,650 |
| 46 | Electric Point Machine-IRS type, (AC Immunity 160V AC), Non-Trailable to operate on 110V DC complete with Lock and Detector slides, Cable Termination Box (143mm throw, thrust as applicable, Rotary locking), confirming to IRS:S 24/2002 (amdt.1) (amdt. upto date if any) & Assy. Drg. No.RDSO-S/10910 (alt. upto date if any) & IRS:S 37/82 (amdt.3) (amdt. upto date if any) for Motor. | Numbers | 20.00 | 65,619 | 13,12,380 |
| 47 | Installation of electric point machines on MS plate fixed on wooden/ concrete sleepers complete with fixing of junction boxes, ground connections including smithy works involved, insulation of MS plate on which the point machine is to be fixed from the gauge tie plate involving riveting/welding of angle cleats, installation of point JB, termination adjustment for operation of points by crank handle, painting and lettering as required including wiring, testing and commissioning. Note: MS plate/flat/angle /angle cleats, paints, bolts & nuts and washers of sizes as required for fixing the point machine shall be supplied by the contractor except point machine. | Numbers | 30.00 | 10,407 | 3,12,210 |
| 48 | DISMANTLING OF EXISTING POINT FITTINGS, AND DRILLING OF HOLES IN STOCK RAIL/TONGUE RAIL/GAUGE TIE PLATE, REARRANGEMENT AND REFIXING OF EXISTING ELECTRICAL POINT DETECTOR IF AVAILABLE AND INSTALLATION OF ELECTRICAL POINT MACHINES ON MS PLATE FIXED ON WOODEN/ CONCRETE SLEEPERS COMPLETE WITH FIXING OF GROUND CONNECTIONS INCLUDING SMITHY JOB FOR WELDIND, INSULATION OF MS PLATE ON WHICH THE POINT MACHINE IS TO BE FIXED OVER THE GAUGE TIE PLATE INVOLVING RIVETTING/WELDING/OF ANGLE CLEATS. TERMINATION AND WIRING OF POINT MACHINE AND ELECTRICAL DETECTOR , PRILIMINARY ADJUSTMENT FOR OPERATION OF POINTS BY CRANK HANDLE, PAINTING AND LETTERING AS REQUIRED INCLUDING WIRING, TESTING, AND COMMISSIONING AS PER TECHNICAL SPECIFICATION. ALL MATERIALS REQUIRED FOR FIXING ARE TO BE SUPPLIED BY THE CONTRACTOR EXCEPT DETECTOR & POINT MACHINE. FOR TURN OUT/TWS. INSPECTION: CONSIGNEE. | Numbers | 30.00 | 8,295 | 2,48,850 |
| 49 | "Installation, wiring and testing of electrical key transmitter for crank handle arrangement, siding control as per yard diagram, approved circuit diagram. Installation portion shall include supply of necessary angles, wooden shelf, nuts & bolts as required for the work. The ward no. Of key shall be advised by the site engineer. This includes supply of electrical key transmitter with key for crank handle interlocking arrangement siding control as per yard diagram, approved circuit diagram and specn.no. IRS-S- 21/01(LATEST) AND IRS-S- 23(LATEST),DRG.NO.SA-22601 (ADV)ALT. 2. [key combination will be intimated by site engineer]"Supply. Inspection : RDSO. | Numbers | 10.00 | 7,345 | 73,450 |
| 50 | "Installation, wiring and testing of electrical key transmitter for crank handle arrangement, siding control as per yard diagram, approved circuit diagram. Installation portion shall include supply of necessary angles, wooden shelf, nuts & bolts as required for the work. The ward no. Of key shall be advised by the site engineer. This includes supply of electrical key transmitter with key for crank handle interlocking arrangement siding control as per yard diagram, approved circuit diagram and specn.no. IRS-S- 21/01(LATEST) AND IRS-S- 23(LATEST),DRG.NO.SA-22601 (ADV)ALT. 2. [key combination will be intimated by site engineer]" Execution. | Numbers | 10.00 | 6,796 | 67,960 |
| 51 | Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: 5-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 8 0 AH Battery. Inspection: RDSO | Numbers | 60.00 | 4,894 | 2,93,640 |
| 52 | Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No.SA- 20161-66/ M or latest. Inspection: Consignee | Numbers | 60.00 | 171 | 10,260 |
| 53 | Installation wiring, testing and commissioning of single rail dc track circuit (TRACK CIRCUIT (BEYOND 200 MTRS.)) as per approved track circuiting plan. The work includes track battery charging and installation, fixing of track bonding (double) with 8 SWG soft GI wire, laying of tail cables with track lead junction box, rail connector with galvanised iron wire, track jumpering(double) with supporting arrangement for holding as per track circuit plan. It also includes installation and wiring of track feed chargers, track relays, track circuit equipment's in the location box including fuses and ARA terminals required for the purpose as per DRG NO. SK/10/95(NKG) including drilling of 9/32" hole on rails where required. Fixing of track lead junction boxes. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided. | Per Track Circuit | 30.00 | 3,259 | 97,770 |
| 54 | Installation wiring, testing and commissioning of single rail dc track circuit (SHORT LENGTH TRACK CIRCUIT UPTO 200 MTS.) a s per approved track circuiting plan. The work includes track battery charging and installation, fixing of track bonding (double) with 8 SWG soft GI wire, laying of tail cables with track lead junction box, rail connector with galvanised iron wire, track jumpering(double) with supporting arrangement for holding as per track circuit plan. It also includes installation and wiring of track feed chargers, track relays, track circuit equipment's in the location box including fuses and ARA terminals required for the purpose as per DRG NO. SK/10/95(NKG) including drilling of 9/32" hole on rails where required. Fixing of track lead junction boxes. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided. | Per Track Circuit | 10.00 | 3,244 | 32,440 |
| 55 | Installation, wiring, testing & commissioning of track circuit involving points & crossings as per track circuiting plan, track battery charging and installation including drilling 9/32" hole on rails; fixing of bonding(double) with 8 SWG soft GI wire, insulation of stretcher bars (leading & following), gauge / crossing tie plates involving cutting and riveting/welding of angle clit, split stretcher bars, fixing of track lead junction box, rail connector with GI wire, track jumpering(double) with supporting arrangement for holding termination of track lead wires, including series jumpers, jumper wire terminals, track feed set(track chargers, resistance, fuses, battery etc.) As per approved IYD for point zone track circuit. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided. | Per Track Circuit | 25.00 | 3,348 | 83,700 |
| 56 | Supply of Track Lead Junction Box(TLJB) made from FRP material including brass bolts and hylam board sheet with terminals etc as per ER drawing number SI/TYP/0096. The technical specifications are as follows:(a) TAB complete with cover to be in black/red having approximate weight of 4.0 Kg with L- 262mm W- 212mm and H 90 mm and all the holes required for mounting on FRP stump (vertically two for each FRP angle) HDPE pipe , cable etc.(b) Each TAB shall have two bakelite terminal block fitted horizontally : each bakelite terminal block shall have t w o nickel chrome plate M10 brass terminal, 50mm long. Alongwith each TAB , nickel chrome plated brass links(two nos.Of adequate strength for vertical linking of the terminals to be supplied.(c) HDPE pipe of size 32/35mm , 380 mm long alongwith two nuts for fixing on the TLJB hole .(d) The FRP stump for mounting the TAB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength t o be supplied alongwith TAB.Inspection: (i) RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | Numbers | 100.00 | 3,564 | 3,56,400 |
| 57 | Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (FRP stumps) with contractor's fixing material. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee | Numbers | 100.00 | 1,316 | 1,31,600 |
| 58 | Supply of B Type Choke as per RDSO Specn. No.IRS: S-65/83 (Airind. 1) or latest. Inspection: RDSO. | Numbers | 60.00 | 5,151 | 3,09,060 |
| 59 | Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. 5- 69/M. Inspection: Consignee. | Numbers | 1000.00 | 4 | 4,000 |
| 60 | Supply of GI wire 8 SWG (4mm dia) suitable for track circuit r a i l bonding. Inspection: Consignee | Numbers | 500.00 | 12 | 6,000 |
| 61 | Provision/Installation of bonding with GI wire 4mm dia (8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm dia. holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site. Inspection: Consignee. | Numbers | 100.00 | 180 | 18,000 |
| 62 | Supply & installation of polymer positive temperature coefficient device (PPTC) resettable fuses, for outdoor circuits. 30V/2.5A for track feed and 60V/1.1A in place of 24V/2A fuse and 120V/1.1A for signal lighting. Make- RAYCHEM, BOURNS, LITTLE FUSE, FUZETEC or TYCO. Quantity as per site engineer. Note- PPTC fuses are to be connected with crimped ring type lugs.". Inspection: Consignee. | Numbers | 100.00 | 79 | 7,900 |
| 63 | "Supply & installation of 'C' class surge protection arrangement at feed end DC Track Ckt Specn no. As follows: - voltage 230 V AC rated voltage 350V AC DIS. CAP 10KA TO 20 KA TIME 100 MILIsecond protection 1.2V degree protection IP.20 TEC-61643-1. Inspection : by consignee." | Numbers | 60.00 | 1,346 | 80,760 |
| 64 | Releasing of existing TLJB and its accessories | Numbers | 50.00 | 748 | 37,400 |
| 65 | "Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1)or latest. Inspection: RDSO"RED Aspect | Set | 25.00 | 8,362 | 2,09,050 |
| 66 | "Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1)or latest. Inspection: RDSO"YELLOW Aspect | Numbers | 50.00 | 8,387 | 4,19,350 |
| 67 | "Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1)or latest. Inspection: RDSO"GREEN ASPECT | Numbers | 25.00 | 9,438 | 2,35,950 |
| 68 | "Supply of various LED signals {Subsidiary Signal}, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO /SPN/153/2011 (Rev.4.1)or latest. Inspection: RDSO"LED for Route Aspect | Numbers | 50.00 | 5,478 | 2,73,900 |
| 69 | "Supply of various LED signals {Subsidiary Signal}, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO /SPN/153/2011 (Rev.4.1)or latest. Inspection: RDSO"LED for Shunt Signal Aspect | Numbers | 20.00 | 5,675 | 1,13,500 |
| 70 | "Supply of various LED signals {Subsidiary Signal}, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO /SPN/153/2011 (Rev.4.1)or latest. Inspection: RDSO"LED for Calling ON signal Aspect | Numbers | 15.00 | 6,830 | 1,02,450 |
| 71 | Supply of CLS Post 5.6 Mtrs. with Base, Ladder as per RDSO Spec. No. IRS-S-6- 81 & Drg. no. SA-23153 (ADV), Alt-1 or Latest. All Drawing as per Latest materials to be procured from Approved List of Firm for Manufracturer. INSPECTION : CONSIGNEE | Numbers | 15.00 | 15,707 | 2,35,605 |
| 72 | "Supply of colour light signal post 4.6 mtrs. and ladder 4.5 mtrs. With bases for ladder and post as per RDSO SPEC. NO. IRS-5-6-8 1 and DRG. NO.SA- 23153/ADV/AIT- 1. All drawing should be as per latest. Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Materials to be procured from approved list of firms for manufacturer & supply of mechanical signalling items. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Numbers | 10.00 | 15,950 | 1,59,500 |
| 73 | SUPPLY OF NON - METALIC (FRP) COLOUR LIGHT SIGNAL HOUSING MULTI UNIT TYPE FOR RLY. SIGNALLING SUITABLE FOR RE AREA 2 ASPECT COMPLETE WITHOUT LENSES, LAMPS AND SIGNAL TRANSFORMER AS PER DRG. NO. SA 23001/A/M(ADV), ALT.8 AND AS PER SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP MATERIAL AS RDSO SPEC NO. RDSO/SPN/ 151/1997 OR LATEST. ALL DRAWDINGS SHOULD BE AS PER LATEST. MATERIALS TO BE PROCURED FROM RDSO'S APPROVED FIRM ONLY. NOTE: SIGNAL UNIT SHOULD BE COMPATIBLE TO 'LED' TYPE. INSPECTION: BY RDSO NOTE: INSTALLATION, ERECTION & WIRING OF SIGNALLING UNIT INCLUDES LED SIGNAL LIGHTING UNIT INCLUDING CURRENT REGULATOR & HEALTH MONITERING UNIT. THIS ALSO INCLUDES PROTECTION OF UNIT FROM RAIN WATER. SUPPLY | Numbers | 10.00 | 26,583 | 2,65,830 |
| 74 | INSTALLATION, ERECTION AND WIRING OF Above mentioned CLS UNIT, POST, LADDER & BASE LED UNIT INCLUDING PAYING OUT OF TAIL CABLE FROM LOCATION BOX AND EARTHING OF CLS (LED TYPE). | Numbers | 10.00 | 1,658 | 16,580 |
| 75 | SUPPLY OF NON - METALIC (FRP) COLOUR LIGHT SIGNAL HOUSING MULTI UNIT TYPE FOR RLY. SIGNALLING SUITABLE FOR RE AREA 3 ASPECT COMPLETE WITHOUT LENSES, LAMPS AND SIGNAL TRANSFORMER AS PER DRG. NO. SA 23002/A/M(ADV), ALT.8 AND AS PER SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP MATERIAL AS RDSO SPEC NO. RDSO/SPN/ 151/1997 OR LATEST. ALL DRAWDINGS SHOULD BE AS PER LATEST. MATERIALS TO BE PROCURED FROM RDSO'S APPROVED FIRM ONLY. NOTE: SIGNAL UNIT SHOULD BE COMPATIBLE TO 'LED' TYPE. INSPECTION: BY RDSO NOTE: INSTALLATION, ERECTION & WIRING OF SIGNALLING UNIT INCLUDES LED SIGNAL LIGHTING UNIT INCLUDING CURRENT REGULATOR & HEALTH MONITERING UNIT. THIS ALSO INCLUDES PROTECTION OF UNIT FROM RAIN WATER. SUPPLY | Numbers | 2.00 | 27,309 | 54,618 |
| 76 | INSTALLATION, ERECTION AND WIRING OF above mentioned CLS UNIT, POST, LADDER & BASE LED UNIT INCLUDING PAYING OUT OF TAIL CABLE FROM LOCATION BOX AND EARTHING OF CLS (LED TYPE). | Numbers | 2.00 | 2,352 | 4,704 |
| 77 | SUPPLY OF NON - METALIC (FRP) COLOUR LIGHT SIGNAL HOUSING MULTI UNIT TYPE FOR RLY. SIGNALLING SUITABLE FOR RE AREA 4 ASPECT COMPLETE WITHOUT LENSES, LAMPS AND SIGNAL TRANSFORMER AS PER DRG. NO. SA 23001/A/M(ADV), ALT.8 AND AS PER SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP MATERIAL AS RDSO SPEC NO. RDSO/SPN/151/1997 OR LATEST. ALL DRAWDINGS SHOULD BE AS PER LATEST. MATERIALS TO BE PROCURED FROM RDSO'S APPROVED FIRM ONLY. NOTE: SIGNAL UNIT SHOULD BE COMPATIBLE TO 'LED' TYPE. INSPECTION: BY RDSO NOTE: INSTALLATION, ERECTION & WIRING OF SIGNALLING UNIT INCLUDES LED SIGNAL LIGHTING UNIT INCLUDING CURRENT REGULATOR & HEALTH MONITERING UNIT. THIS ALSO INCLUDES PROTECTION OF UNIT FROM RAIN WATER. SUPPLY | Numbers | 15.00 | 30,783 | 4,61,745 |
| 78 | INSTALLATION, ERECTION AND WIRING OF CLS UNIT as mentioned above, POST, LADDER & BASE LED UNIT INCLUDING PAYING OUT OF TAIL CABLE FROM LOCATION BOX AND EARTHING OF CLS (LED TYPE). | Numbers | 15.00 | 2,730 | 40,950 |
| 79 | SUPPLY OF 1 WAY AS PER RDSO DRG. NO. SA-23401 (ADV) NON METALIC FRP JUNCTION TYPE ROUTE INDICATOR FOR RAILWAY SIGNALLING SUITABLE FOR RE AREA WITHOUT LAMP. LENSES, SIGNAL TRANSFORMER. AS PER RDSO SPEC NO. RDSO/SPN/194/2006 (VER - 1.0) OR LATEST. FRP MATERIAL AS PER RDSO SPEWC NO. RDSO/SPN/151/ 1997 OR LATEST. ALL DRAWINGS SHOULD BE AS PER LATEST. MATERIAL TO BE PROCURED FROM RDSO'S APPROVED FIRM ONLY. NOTE: SIGNAL UNIT SHOULD BE COMPATIBLE TO LED TYPE. INSPECTION: BY RDSO. NOTE: INSTALLATION, ERECTION & WIRING OF SIGNALLING UNIT INCLUDES LED SIGNAL, LIGHTING UNIT INCLUDING CURRENT REGULATOR & HEALTH MONITORING UNIT. THIS ALSO INCLUDES PROTECTION OF UNIT FROM RAIN WATER. | Numbers | 4.00 | 34,117 | 1,36,468 |
| 80 | INSTALLATION, ERECTION AND WIRING OF above mentioned 1 way JUNCTION TYPE ROUTE INDICATOR [LED TYPE] | Numbers | 4.00 | 669 | 2,676 |
| 81 | SUPPLY OF 2 WAY AS PER RDSO DRG. NO. SA-23401 (ADV) NON METALIC FRP JUNCTION TYPE ROUTE INDICATOR FOR RAILWAY SIGNALLING SUITABLE FOR RE AREA WITHOUT LAMP. LENSES, SIGNAL TRANSFORMER. AS PER RDSO SPEC NO. RDSO/SPN/194/2006 (VER - 1.0) OR LATEST. FRP MATERIAL AS PER RDSO SPEWC NO. RDSO/SPN/151/ 1997 OR LATEST. ALL DRAWINGS SHOULD BE AS PER LATEST. MATERIAL TO BE PROCURED FROM RDSO'S APPROVED FIRM ONLY. NOTE: SIGNAL UNIT SHOULD BE COMPATIBLE TO LED TYPE. INSPECTION: BY RDSO. NOTE: INSTALLATION, ERECTION & WIRING OF SIGNALLING UNIT INCLUDES LED SIGNAL, LIGHTING UNIT INCLUDING CURRENT REGULATOR & HEALTH MONITORING UNIT. THIS ALSO INCLUDES PROTECTION OF UNIT FROM RAIN WATER. / ALT.2 | Numbers | 3.00 | 43,270 | 1,29,810 |
| 82 | INSTALLATION, ERECTION AND WIRING OF above mentioned 2 Way JUNCTION TYPE ROUTE INDICATOR [LED TYPE] | Numbers | 3.00 | 1,203 | 3,609 |
| 83 | SUPPLY OF 3 WAY AS PER RDSO DRG. NO. SA-23401 (ADV) NON METALIC FRP JUNCTION TYPE ROUTE INDICATOR FOR RAILWAY SIGNALLING SUITABLE FOR RE AREA WITHOUT LAMP. LENSES, SIGNAL TRANSFORMER. AS PER RDSO SPEC NO. RDSO/SPN/194/2006 (VER - 1.0) OR LATEST. FRP MATERIAL AS PER RDSO SPEWC NO. RDSO/SPN/151/ 1997 OR LATEST. ALL DRAWINGS SHOULD BE AS PER LATEST. MATERIAL TO BE PROCURED FROM RDSO'S APPROVED FIRM ONLY. NOTE: SIGNAL UNIT SHOULD BE COMPATIBLE TO LED TYPE. INSPECTION: BY RDSO. NOTE: INSTALLATION, ERECTION & WIRING OF SIGNALLING UNIT INCLUDES LED SIGNAL, LIGHTING UNIT INCLUDING CURRENT REGULATOR & HEALTH MONITORING UNIT. THIS ALSO INCLUDES PROTECTION OF UNIT FROM RAIN WATER. | Numbers | 5.00 | 39,151 | 1,95,755 |
| 84 | INSTALLATION, ERECTION AND WIRING OF Above mentioned 3 Way JUNCTION TYPE ROUTE INDICATOR [LED TYPE] | Numbers | 5.00 | 1,583 | 7,915 |
| 85 | Supply of position light shunt signal unit (without lenses, lamps) with Base Post and without signal transformer a s per RDSO DRG NO. SA- 23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type."Supply.Inspection: (i)RDSO/RITES if value of item in work more t h a n 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Numbers | 5.00 | 6,782 | 33,910 |
| 86 | Installation, erection and paying out of tail cable from location box and wiring of shunt signal, LED unit as per technical specification. | Numbers | 5.00 | 502 | 2,510 |
| 87 | "Supply of Calling ON/ Guard Repeater Signal Unit with Brackets & Fixing accessories. Calling ON/ Guard Repeater Signal Unit shall conform to RDSO Drg no 24351(Adv) A1t1 suitable to LED Signal Lighting Unit. Inspection: (i)RDSO /RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." SUPPLY. INSPECTION: BY CONSIGNEE | Numbers | 20.00 | 2,533 | 50,660 |
| 88 | "Installation of Calling ON/ Guard Repeater Signal Unit with Brackets & Fixing accessories. Calling ON/ Guard Repeater Signal Unit shall conform to RDSO Drg no 24351(Adv) A1t1 suitable to LED Signal Lighting Unit. | Numbers | 20.00 | 2,331 | 46,620 |
| 89 | Supply installation of P/C/G/A/AG marker (size 250mm dia circle) high intensity prismatic (TYPE-IV) retro reflective sheet over 2mm thick aluminium sheet & letter will be screen printing (250 mm dia circle) as per drg. S&T/SDAH/SK-1383 and technical specification attached. This will include cost of all materials including fixing clamp required for this work. Inspection By:- RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] | Numbers | 21.00 | 550 | 11,550 |
| 90 | "Supply, Fabrication and Fixing of Retro reflective Nomenclature Board of size 254 mm x 358 mm made of 2mm thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE -IV) including fixing arrangement for fixing them on existing post per DRG. NO. S&T/SDAH /SK-1386 and as per standard practice.Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Numbers | 35.00 | 373 | 13,055 |
| 91 | Casting, Concreting & Curing of Foundtation for Main Signal OF 2/3/4 A s p e c t s . This includes cost of the Excavation of Trench for Main Signal Foundtation as per DRG. No.SGW/MGS/S/1/91. Making Shuttering inside the Excavated Trench as per Schedule of Diemnsion. Casting, Concreting, and Installation of Anchor bolt to hold the Signal Base and curing the concrete foundtation as per above drawing. All materials required for Execution will be supplied by the contractor including holding Ancor Bolt Complete as per Drg. No. SA-116/A/M or Latest , Sand, Cement, Stone chips etc. Excavation of Pit and casting of foundtation shall be as per Railway Standard Practice. Signal post and base will be supplied by the railway. | Numbers | 25.00 | 8,065 | 2,01,625 |
| 92 | Casting, concreting and curing of foundation for Shunt s i g n a l including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor, including holding down galvanised bolts & nuts with washers, cement, sand, stone chips, etc. As per DRG. NO SK/5/95/NKG. | Numbers | 5.00 | 4,087 | 20,435 |
| 93 | Releasing & Dismentling of existing Signal Post, Route indicator, and Signal Unit along with complete fittings with out damaging any parts. | Numbers | 31.00 | 1,218 | 37,758 |
| 94 | In s ta lla t io n o f m a g n e t o / control telephone, annunciator with all accessories and dry cells (2 nos.) For each phone with wooden battery box. | Numbers | 10.00 | 195 | 1,950 |
| 95 | Supply of magneto telephones with all accessories including supply of 2 nos. Dry cell for each telephone with wooden battery box. (i) SPEC.FOR magneto telephone IRS-TC- 79/2000.AMD-1 OR LATEST. | Numbers | 10.00 | 3,509 | 35,090 |
| 96 | Supply of annunciator, 8 lines. Inspection: - consignee | Numbers | 2.00 | 8,478 | 16,956 |
| 97 | Supply of Office Chair make Godrej CH- 7B or similar of reputed brand. Inspection: Consignee | Numbers | 10.00 | 2,902 | 29,020 |
| 98 | Supply of Office table with laminated top with three drawers on left hand side and one locker on the right hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX 75cm) or Similar o f repute d brand. Inspection: Consignee | Numbers | 5.00 | 12,886 | 64,430 |
| 99 | "Supply , Installation, testing & commissioning of new modular workspace make or Cosmos or similar, new Modular control desk for provision of two numbers of monitors of size 65 inch. Detailed drawing of workspace is given in Annexure )2.2 of Tender document. This item includes : (i) Desktop made of 12 mm ASS + ASS 12 mm MDF (ii) structure : powder coated aluminium sturdy structure and extreme side aesthetic legs (iii) shutters : 18mm MDF (iv) proper cooling arrangement for CPR cabinet (v) 2mm thick extruded aluminium ""SLAT"" wall . The workspace will be provided for storage in SLAT system, this includes space for housing two numbers of embedded PC , 2 No. of FDMS and their power supply arrangement with proper ventilation. This includes supply of two chairs (Godrej PCH 7002 D or superior , as approved by Engineer in charge) for operators to be supplied. Inspection: Consignee" | Station | 1.00 | 6,08,777 | 6,08,777 |
| 100 | "Supply, Installation, Testing & Commissioning of Microprocessor based Networkable Analogue Addressable up to 64 nodes 1 Loop Fire Alarm Control panel with LCD display, the panel should be equipped with sufficient No. of loop as per RDSO Specification No. RDSO/SPN/217/2018 ver 2.0 or latest. Each loop shall have capacity of 127 analogue addressable devices in 1 loop, the panel shall have sufficient No. of programmable relay control for controlling AHU's, pressurisation fans, ventilation fans at fire pump room, monitoring of fire sprinkler & sealed lead acid batteries sufficient for 24 Hours normal working & then capable of operating the system for 24 Hours during Emergency conditions as required. The panel shall have provision of connectivity of BACNET/ MODBUS/ LONWOK/TCP-IP. The panel shall have dedicated RS232 serial port for direct PC or MODEM connection, optional remote printer as per RDSO Specification No. RDSO/SPN/217/2021 ver 3.0 or latest. Inspection: RDSO." | Numbers | 1.00 | 62,379 | 62,379 |
| 101 | "Supply, Installation, Testing & Commissioning of intelligent Analogue Addressable Multi-Sensor type smoke detector with inbuilt fault isolator and integral response indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air current. Detector should have unique address for communication and assigned through panel with mounting base as required with the protection category of IP 40. All items as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. Inspection: RDSO." | Numbers | 25.00 | 3,122 | 78,050 |
| 102 | Supply, Installation, Testing & Commissioning of Analogue Addressable Manual Call Point with integral short circuit isolator, Analogue addressable protocol having status LED for alarming & standby mode, electronically addressed) as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. Inspection: RDSO. | Numbers | 4.00 | 3,750 | 15,000 |
| 103 | Supply, Installation, Testing & Commissioning of Linear Heat Sensing (LHS) cable as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. Inspection: RDSO. | Metre | 250.00 | 830 | 2,07,500 |
| 104 | "Supply, Installation, Testing & Commissioning of LHS interface module as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver. 3.0 or latest.Inspection: RDSO." | Numbers | 1.00 | 44,260 | 44,260 |
| 105 | Supply, Installation, Testing & Commissioning of intelligent Addressable Loop Powered Sounder cum beacon with base inbuilt fault isolator with protection category of IP42 and duly approved as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. Inspection: RDSO. | Numbers | 3.00 | 8,275 | 24,825 |
| 106 | "Supply, Installation, Testing & Commissioning of FRLS unarmoured/ armoured cable(2Cx1.5 sq.mm) with all accessories for connection of all Fire Alarm devices as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latestInspection: RDSO." | Metre | 250.00 | 113 | 28,250 |
| 107 | Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI Mark IS: 15683 operating temperature (-30)° to (50)° for class 13 B type of fire with 1 mtr. Hose pipe fitted with PVC bend horn complete in all respect. | Numbers | 4.00 | 5,176 | 20,704 |
| 108 | Supply of full size apparatus case (GKP type) (as per DRAWING NO. SW SK NO. 4/90 & & other applicable GKP SW Drawing). This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RECOMMENDED L I S T O F F I R M S FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy | Numbers | 80.00 | 13,916 | 11,13,280 |
| 109 | Casting, concreting and curing of concrete foundation ((in ratio 1:3:6), erection and installation of full size apparatus case (GKP type)/Stainless Steel (SS) Apparatus Case as per DRG.NO. S&T/C-6/98(NKG) with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti- corrosive paints as per IS:- 9862-1981, one and half feet from the bottom, on all surfaces- both inside and outside. Inspection: Consignee | Numbers | 80.00 | 3,532 | 2,82,560 |
| 110 | Fixing by Slotted angle, Wiring of the Terminal Strips, Hylum strip, Relays fuses with base, Fixing of the hard wood Shelves for Full Size Apparatus Case with termination & earthing of the Cables and wiring with lettering as required. This including supply of slotted angles, wires, ferrules for marking and misc. materials per location to be supplied by the contractors. (All materials except Location Boxes, Relay, terminal strips, bakelite strip, fuses with base to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO approved firm. (Quantity of the wires to be specified by contractor). NB: Power cable to be terminated with proper Lug and required Buss bar and other terminals to be supplied by the contractor. | Numbers | 80.00 | 4,830 | 3,86,400 |
| 111 | SUPPLY OF HALF SIZE APPARATUS CASE (GKP TYPE) (AS PER GKP TYPE DRAWING NO.SE/FE/2004/21 & OTHER APPLICABLE GKP SW DRAWING). THIS INCLUDES SUPPLY OF LOCATION BOX (GKP TYPE) WITH 'E' TYPE LOCK & KEY, FITTED ON LOCATION DOOR ON BOTH SIDE, E TYPE LOCK (WARD NO WILL BE SPECIFIED BY ENGINEER-IN CHARGE) AS PER RDSO DRG. NO. SA 3376 AND KEY TO DRG. NO. 3377 AS PER RDSO DRAWING NO. RDSO/S-11500. | Numbers | 10.00 | 7,860 | 78,600 |
| 112 | CASTING, CONCRETING AND CURING OF CONCRETE FOUNDATION AND ERECTION OF HALF SIZE APPARATUS CASE. | Numbers | 10.00 | 3,105 | 31,050 |
| 113 | FIXING BY SLOTTED ANGLE, WIRING OF TERMINAL STRIPS, HYLAM STRIP, RELAYS, FUSES WITH BASE, FIXING OF HARD WOOD SHELVES FOR HALF SIZE APPARATUS CASE WITH TERMINATION & EARTHING OF CABLES. | Numbers | 10.00 | 3,536 | 35,360 |
| 114 | SUPPLY OF HARD WOOD SHELVES THICKNESS 25 MM FOR KEEPING EQUIPMENTS AND BATTERIES IN THE LOCATION BOX (FULL OR HALF GKP/ OTHER TYPE) WITH SUITABLE VARNISH AND ANTI-TERMITE CHEMICALS FITTED ON ANGLES WITH NUTS AND BOLTS. INSPECTION: CONSIGNEE950 X 400 X 25 MM FOR FULL SIZE LOCATION BOX | Numbers | 80.00 | 563 | 45,040 |
| 115 | SUPPLY OF HARD WOOD SHELVES THICKNESS 25 MM FOR KEEPING EQUIPMENTS AND BATTERIES IN THE LOCATION BOX (FULL OR HALF GKP/ OTHER TYPE) WITH SUITABLE VARNISH AND ANTI-TERMITE CHEMICALS FITTED ON ANGLES WITH NUTS AND BOLTS. INSPECTION: CONSIGNEE 450 X 400 X 25 MM FOR HALF SIZE LOCATION BOX | Numbers | 10.00 | 450 | 4,500 |
| 116 | SUPPLY OF PAPER BASE HYLAM SHEET 12 MM THICK. | Sqm | 100.00 | 5,370 | 5,37,000 |
| 117 | Alteratio n or Vertical Alignment or Changing of the Location Box along with the renovation of foundtation where required, and placing of earth sorrounding the Location Box and rammed up well upto required level so that the Location Box shall fixed on its place properly & rigitely. The earth shall be taken from the end point of the Railway Boundary perpendicularly. Renovation of foundation & Sand Filling of Location Box shall be done if required as per direction of the site engineer. All renovation materials shall be supply by the contractor. | Numbers | 15.00 | 2,782 | 41,730 |
| 118 | Dismantling of location box / RCC Goomty including all its accessories & concrete foundation. | Numbers | 40.00 | 651 | 26,040 |
| 119 | Supply of Medium class GI pipes 100 mm dia {4.5 mm thickneee} as per IS 1239 (Part 1}: 2004 or Latest with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. | Metre | 300.00 | 762 | 2,28,600 |
| 120 | Laying 4s Firing of Medium claee GI pipee 50/ 100 mm dia {4.5 mm thickness} as per IS 1239 {Part 1}: 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends. | Metre | 300.00 | 98 | 29,400 |
| 121 | Supply of 40 mm outer dia permanently lubricated HDPE telecom duct No.G/CDS- 08/02,Nov,04 with latest amendment. Inspection : Consignee | Kilometre | 5.00 | 62,867 | 3,14,335 |
| 122 | Laying Of HDPE DUCT,40/33 mm in trenchs and protective works including pulling of mono mode OFC Cable( fibre) through duct . | Kilometre | 5.00 | 24,734 | 1,23,670 |
| 123 | Supply of Double Wall Corrugated (DWC) -HDPE pipe/duct of size 200 mm outer dia, R 175 mm inner dia. It includes supply of Double Wall Corrugated -H DPE pipe/duct as per RDSO Specn. No. RDSO/ SPN/ 204/2011 (version 1.1) or latest and conforming to ISI Spec. No.IS:14930, Part- II. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber O-Ring 2) Spacers3) Tees4) Bend,5) End-capDWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. | Metre | 200.00 | 397 | 79,400 |
| 124 | Placing of DWC HDPE /RCC/GI pipes along with collars in trenches at places near track and road, crossings, platform cuttings etc. | Kilometre | 200.00 | 31 | 6,200 |
| 125 | Supply of Jointing Kit of underground Quad cable with thermo Shrink jointing kit which includes supply of jointing kit as per RDSO spec. No IRS :TC: 77-2012, Rev.3 with Amd no 1 & 2 or latest. Inspection : Consignee | Numbers | 7.00 | 2,185 | 15,295 |
| 126 | Jointing of underground Quad cable with thermo Shrink jointing kit which includes supply of jointing kit as per RDSO spec. No IRS :TC: 77-2012, Rev.3 with Amd no 1 & 2 or latest. | Numbers | 7.00 | 956 | 6,692 |
| 127 | TRANSPORTATION OF HDT MACHINE WITH ACCESSORIES INCLUDING HANDLING OF STORES MATERIALS , PREPARATION OF SITES AND BOARING FOR PLACING OF 110 MM DIA HDPE/DWC PIPE FOR CROSSING OF S&T CABLES TOGETHER A BRIDGES/CULVERT, PUCCA ROAD/CROSSING, BOARING TRENCH AHALL BE MINIMUM 3 MTR BELOW THE RIVER BED AND 1 MTR BELOW THE TRACK /ROAD/PUCCA ROAD CROSSING AREA. THIS INCLUDES SUPPLY OF ACCESSORIES FOR HDPE/DWC PIPES. BOARING UP TO THE LENGTH OF 150 MTR | Metre | 1500.00 | 1,804 | 27,06,000 |
| 128 | TRANSPORTATION OF HDT MACHINE WITH ACCESSORIES INCLUDING HANDLING OF STORES MATERIALS , PREPARATION OF SITES AND BOARING FOR PLACING OF 110 MM DIA HDPE/DWC PIPE FOR CROSSING OF S&T CABLES TOGETHER A BRIDGES/CULVERT, PUCCA ROAD/CROSSING, BOARING TRENCH AHALL BE MINIMUM 3 MTR BELOW THE RIVER BED AND 1 MTR BELOW THE TRACK /ROAD/PUCCA ROAD CROSSING AREA. THIS INCLUDES SUPPLY OF ACCESSORIES FOR HDPE/DWC PIPES. BOARING ABOVE THE LENGTH OF 150 MTR | Metre | 500.00 | 2,379 | 11,89,500 |
| 129 | Construction and fixing of type III RCC cable duct ( pre-cast) for cable laying in station yard (this includes laying of cable through cable duct as per site engineer) as per drawing no.SI/S&T/1/24Inspection : Consignee | Numbers | 2000.00 | 3,742 | 74,84,000 |
| 130 | Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C- 40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. Of cables headway is not available, 4" of 1:2:4 concreting should b e done. Note:-(b-1) payment wifi be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. Or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. | cum | 3500.00 | 245 | 8,57,500 |
| 131 | Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches. The sharp edges will be smoothened out in bottom of the chase and will be leveled properly. In hard rocky ground area , cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground cannot be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables is small. In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.1.2 mtr is not possible and it will be decided by site engineer/unit officer incharge of work. | cum | 45.00 | 497 | 22,365 |
| 132 | Excavation of OFC pit for cable jointing of size 1.5m x 1.5m x1.2 m for all type of soils. The section. Back filling the pit and ramming after jointing. Provision of brick walling the four walls and bottom of pit with RCC slab, back filling with earth and ramming as per drawing. N.B. all the materials including cement required for the above will be supplied by the tenderer. | Numbers | 3.00 | 6,674 | 20,022 |
| 133 | LAYING OF SIGNALLING CABLE /TELECOM CABLE/POWER CABLE / QUAD / OFC CABLE OF DIFFERENT SIZES AS PER CABLE ROUTE PLAN AND INSTRUCTION OF SITE ENGINEER AND AS PER RAILWAY PRACTICE (CABLE WILL BE SUPPLIED BY THE RAILWAY.) | Metre | 100000.00 | 5 | 5,00,000 |
| 134 | Supply of optic fiber splice closure (48 fiber) as per tec. Specification no. G/OJC- 02/01, March'99 with latest amendment or latest including all miscellaneous items and consumables for fiber splicing. Inspection: - by consignee. | Numbers | 10.00 | 3,558 | 35,580 |
| 135 | Jointing, terminating & splicing of 48 fiber optic fiber cable and fixing of termination box/FDF/placing of joint closures in the pit required at various locations including transportation of all the jointing & terminating materials from railway store to the work site and returning leftover materials to the railway store. | Numbers | 10.00 | 10,625 | 1,06,250 |
| 136 | Supply and installation of Earth leakage detector (12 Nos. channel) Level-2 as per RDSO specification no. RDSO/SPN/256/2025 version : 2.0 or latest inspection by RDSO. Wiring from power supplies in CTR/IPS etc to ELD to be done by firm. All material required to be supplied by the firm. | Numbers | 3.00 | 1,67,829 | 5,03,487 |
| 137 | "Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL, IEC to be produced. It consist of following:(a) Copper bonded steel electrode of 3.0 m long,17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no.(b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth r o d - 1 no.(d) Copper strip of 300x25x6 mm (MEEB) = 1 no.(e) Copper strip of l50x25x6mm (SEEB) = 1 no.(ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter )(iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB(v) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO" | Numbers | 30.00 | 15,147 | 4,54,410 |
| 138 | "Installation of Unit Maintenance Free Earth as supplied i n a b o v e i t e m . It includes ( i ) Digging the earth to the required depth.(ii) Insertion of electrode. (iii) Filling of earth enhancing compound ( A p p r o x . 3 0 Kg)(iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor.(v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and bus bars to various equipments. Earth electrode of17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper a n d o u t e r s u r f a c e (minimum copper bonding thickness o f 2 5 0 microns to made requirement of under writer's laboratories (UL) 467-2007 o r latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential bus bar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential bus bar in relay room, power roo m a n d panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest.Inspection: Consignee" | Numbers | 30.00 | 6,579 | 1,97,370 |
| 139 | SUPPLY OF EARTH ELECTROD MILD STEEL GALVANISED, LIGHT CLASS, IS: 1239(PART-1) 1979. Detailed drawing of Earth Electrode is attached with the tender document.Inspection : Consignee | Numbers | 100.00 | 1,496 | 1,49,600 |
| 140 | SUPPLY OF MS FLAT (SPEC. NO.226 STD) OF SIZE 35MM. X 6MM. WITH LENGTH 5 MTR. WITH HOLES OF 12 MM. DIA. AT BOTH ENDS AS PER CSTE/KKK'S SKETCH NO. S&T 1/2007. INSPECTION: Inspection : Consignee | Numbers | 100.00 | 911 | 91,100 |
| 141 | FIXING OF EARTH ELECTRODE INCLUDINGLAYING AND INSTALLATION OF M.S FLAT OFSIZE 35 MM. X 6 MM. WITH LENGTH 5 MTR AS PER CSTE/ER DRG NO. S&T-1/2007 FOR SIGNALLING EQUIPMENT AS PER INSTRUCTION OF SITE ENGINEER. PROVISION FOR FIXING OF MS FLAT AT SIG. EQIP. SHOULD BE MADE BY TH3E FIRM AST SITE. FULL THREADED BOLTS OF 10 MM DIA AND LENGTH 40 MM SHOULD BE WELDED IN THE SIG. EQUIP IN SUCH WAY THAT THE MS FLAT AT ONE END CAN BE FIXED FROM OUT SIDE OR FROM INSIDE. WELDING ARRANGEMENT WITH ACCESSORIES AND WELDING MATERIALS SHOULD BE ARRANGED BY THE CONTRACTOR FOR FIXING OF BOLTS AT EQUIP. END WHERE REQUIRED AS PER INSTRUCTION OF SITE ENGG. ALL HARDWARE & OTHER MISC. MATERIALS REQUIRED FOR INSTALLATION TO BE SUPPLIED BY THE CONTRACTOR EXCEPT EARTH ELECTRODE AND MS FLAT. NOTE: ALL MATERIALS REQUIRED TO BE ARRANGED BY THE CONTRACTOR EXCEPT 2 CORE CABLE WILL BE SUPPLIED BY THE RAILWAY. | Numbers | 100.00 | 1,161 | 1,16,100 |
| 142 | SUPPLY AND INSTALLATION OF EARTHING ARRANGEMENT FOR EI SYSTEM. EARTHING [RING EARTH WITH MINIMUM TEN EARTH ELECTRODES] OF E.I EQUIPMENT AS PER RDSO SPECIFICATION RDSO/SPN/197/2016 VERSION 1.0 OR LATEST and TAN STS/E/TAN/3006 Ver.3.1. NOTE:- MATERIAL USED FOR EARTHING TO BE INSPECTED BY RDSO BEFORE USE. | Set | 1.00 | 2,35,844 | 2,35,844 |
| 143 | Supply of UTP CAT-6 cable make Siemen/ Systemax / Panduit/ Tyco/ Krone/ AMP. Inspection: Consignee | Metre | 1000.00 | 19 | 19,000 |
| 144 | Supply of patch chord cable (10 meter long) with FC/PC connectors compatible with SDH equipments as per TEC Specn.No.GR/ OFJ-02/ 01 May 2004 with latest Amendment. Inspection: Consignee | Numbers | 10.00 | 909 | 9,090 |
| 145 | Supply, installation and complete indoor wiring of 19 inch (42U) covered Rack of size 2035 mm x 600 mm x 600 mm (Approx.). The rack shall be complete w i t h a l l fi t t i n g s f o r h o u s i n g SDH equipments, Primary MUXES, DDF, MDF using crone modules and other equipments like runway ladders etc. completely wired and equipped with integrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipments with only order wire telephone remaining outside t h e rack. Inspection: Consignee | Numbers | 4.00 | 37,570 | 1,50,280 |
| 146 | "Supply of SMPS based Battery Chargers as per RDSO Spec for Telecom use 48 volts, 25 Amps in 2+1 configuration modules of 25 Amps with ultimate expandable capacity 50 Amps, automatic switching between the modules as per RDSO Spec No. RDSO/ SPN/TC/23/1999 version 4 or latest along with two potential free contacts. Inspection:(i) RDSO if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Numbers | 1.00 | 92,728 | 92,728 |
| 147 | Installation o f Battery chargers, Power distribution Board along with MCBs of suitable ratings and wiring and commissioning of External alarm contacts through EMS. The work includes supply of battery rack, MCBs, battery cable and battery lugs and other accessories required for installation of power plant. Inspection: Consignee | Numbers | 1.00 | 4,578 | 4,578 |
| 148 | Supply of 48Volt/300AH maintenance free VRLA Batteries duly charged as per IRS Spec. No. S- 93/96(A) with amendments- 1 or latest | Numbers | 1.00 | 89,393 | 89,393 |
| 149 | Installation, wiring, testing & commissioning of 48Volt/300AH maintenance free VRLA Batteries duly charged as per IRS Spec. No. S-93/96(A) with amendments- 1 o r latest. Inspection: Consignee | Numbers | 1.00 | 19,268 | 19,268 |
| 150 | "Supply of power supply unit for telecom installation at way side station suitable to operate max 6 equipment of DTMF type (12V/7AH) battery with suitable battery charger) as per RDSO spec. No. IRS: TC-72-97 or latest.Inspection: consignee." | Numbers | 2.00 | 3,740 | 7,480 |
| 151 | Supply of 4W way station DTMF equipment as per RDSO spec. no IRS - TC 60 93 or latest (with 4 wire telephone as per spec. No IRS - TC 38 97or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone. Inspection by Consignee | Numbers | 6.00 | 6,710 | 40,260 |
| 152 | Installation of 4W way station DTMF equipment as per RDSO spec. no IRS - TC 60 93 or latest( with 4 wire telephone as per spec. No IRS -TC - 38/97 or latest. Make - Bentron , Epsilon or similar and supply of 12V/7AH power supply unit for control phone. | Numbers | 6.00 | 1,257 | 7,542 |
| 153 | Supply of PVC cable channel of 25 MM x 25 MM as per specification. | Metre | 100.00 | 66 | 6,600 |
| 154 | "Execution/fixing of 25 MM x 25 MM PVC channel on wall including supply of all fixing materials & accessories by contractor. Returning the left over material to the railway store." | Metre | 100.00 | 20 | 2,000 |
| 155 | "Shifting and installation of control and other telecom equipment like control phone, magneto phone, auto phone, VHF sets, VF Repeaters etc. from old station building to new station building as per instructions of site engineer. All the material required for fixing and installation will be supplied by the contractor.Inspection: Consignee." | Station | 1.00 | 9,122 | 9,122 |
| 156 | "Supply of Digital Clock suitable for Office Complex with GPS Synchronization in standalone mode as per Clause 6 of RDSO SPN TC 62/2008, (Rev 3.0) with Amdt. upto-date. " | Numbers | 2.00 | 13,215 | 26,430 |
| 157 | "Supply of V.F. transformer 1220:600/470 /:1220 as per IRS:TC-22/ 76 or latest. Inspection - consignee" | Numbers | 10.00 | 732 | 7,320 |
| 158 | "Installation of V.F. transformer 1220:600/470 /:1220 as per IRS:TC-22/ 76 or latest. Inspection:- consignee" | Numbers | 10.00 | 430 | 4,300 |
| 159 | "Supply of 10 pair switchboard indoor copper cable 0.6 dia as per specification IRS:TC:24:91. or TEC/GR/WIR-06/ 03. MAR 2002 with latest amendment." | Metre | 500.00 | 49 | 24,500 |
| 160 | "Supply of 2 MB Programmable Primary Digital drop insert multiplexer as per RDSO Specs. IRS TC- 68/2004 (Amnd.1) or latest with conference facility and other stipulation to tender documents and fully wired for 30 channels complete with power supply card, remote control, supervision facility and all other accessories, installation material, manuals etc. It should have facilities to accommodate data interface card in multi drop modeand should be able to support cards needed for video conferencing and ISDN. It shall support NMS installed at Test Room and may operate local/remote location of entire section. It also includes submission of all technical documents, manuals and supply of all miscellaneous items which will be required for final testing and commissioning of system. The above MUX should be equipped with following circuits: i) 2 wire/ 4 wire E&M VF circuits ( minimum 16 nos ckts) ii) Subscriber loop circuits ( minimum 4 nos ckts) iii) Exchange loop interface circuits (minimum 8 circuits ) iv) This also includes connecting all pigtails, optical patch cords etc. to the SDH equipment. This also includes connection of SDH and primary MUX equipment with all interface cards to the 48V Bus including supply of wires and connectors termination of all evens on DDF taking PVC cable over runway or a wall and termination of VF interface circuit to the Krone type. Inspection:(i) RDSO if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs or as per extant policy." | Numbers | 2.00 | 1,49,308 | 2,98,616 |
| 161 | "Installation, wiring, testing and commissioning of 2 MB Programmable Primary Digital drop insert multiplexer as per RDSO Specs. IRS TC- 68/2004 (Amnd.1) or latest with conference facility and other stipulation to tender documents and fully wired for 30 channels complete with power supply card, remote control, supervision facility and all other accessories, installation material, manuals etc. It should have facilities to accommodate data interface card in multi drop mode and should be able to support cards needed for video conferencing and ISDN. It shall support NMS installed at Test Room and may operate local/remote location of entire section. It also includes submission of all technical documents, manuals and supply of all miscellaneous items which will be required for final testing and commissioning of system. The above MUX should be equipped with following circuits: - i) 2 wire/ 4 wire E&M VF circuits ( minimum 16 nos ckts) ii) Subscriber loop circuits ( minimum 4 nos ckts) iii) Exchange loop interface circuits (minimum 8 circuits ) iv) This also includes connecting all pigtails, optical patch cords etc to the SDH equipment. This also includes connection of SDH and primary MUX equipment with all interface cards to the 48V Bus including supply of wires and connectors termination of all evens on DDF taking PVC cable over runway or a wall and termination of VF interface circuit to the Krone type. All materials such as wires for Earthing & power supply, wire carrying aluminium ladder, MCB, Connectors, foundation bolts, nuts, base frame, mounting accessories for fitting of transformers, U-Link Panels, inter connecting cables etc. required for the above shall be supplied by the contractor. " | Numbers | 2.00 | 11,372 | 22,744 |
| 162 | "Supply of standard 19""rack mountable , -48V DC working, Add-Drop STM-4 SDH equipment conforming to GR No. TEC/GR/TX/SDH - 010/03.Jan 2011 (with latest amendment) complete with redundant power supply, 2 no. STM 4 of aggregate L.4.2 Optical interface modules/Cards one each for East and west side, TX/RX and 2 nos. of STM-1 S 1.1 optical interface modules complete with 5 mtrs long optical fibre cords, 21 E1s with DDFs and cable assembly for termination to DDF and minimum 8 nos. of 10/100 Base-T Ethernet ports, Fast Ethernet on SDH [EoS] 10/100 Base-I interface module/card supporting with LCAS and GEP, order wire sub Rack DDF installation material, manuals and other accessories. Complete Engineering order wire (EOW) arrangement. Necessary/ Firmware for local/remote monitoring/ configuration of the equipment through EMS and Software/Firmware interface to work all Network elements as Gateway Network Element [GNE], 2 nos of MCBs of appropriate rating and necessary connecting cords and cables for power supply modules. " | Numbers | 1.00 | 1,99,228 | 1,99,228 |
| 163 | Installation and commissioning of STM-4 in the existing rack with ready infrastructure or in new rack as desired by the site Engineer. | Numbers | 1.00 | 23,495 | 23,495 |
| 164 | "Supply of DC-DC converter. for emergency communication through V.H.F. as per specification - the DC DC converter shall be independent for each vhf base equipment (voice equipment) and shall allow to work from -48V nominal input (-48V to -60V variation) & output 12V DC. The power capacity to deliver 10A current with output short circuit protection & ripple voltage less than 5mv for telecom circuit. Short circuit current not more than 2 mA, input- output insulation by 2.5 KV, load & output regulation +/-1% with ERTL certification. Make: DACS, Pune or Webfil Kolkata or Machronics, Kolkata or similar. Inspection: consignee." | Numbers | 2.00 | 20,742 | 41,484 |
| 165 | "Supply of Buffer amplifier for emergency communication through V.H.F. As per voice frequency channel shall be 600 ohms balanced 4W (viz. 2W for transmit, 2W for receive) and 2W for E&M signalling. The nominal voice frequency signal shall be 0 dbm level the buffer amplifier should work of - 48vdc or can from the DC-DC converter. Burn in of the complete equipment at 55 degree centigrade to avoid infancy failures. During the test the equipment shall be kept continuously on. Inspection: consignee." | Numbers | 5.00 | 13,837 | 69,185 |
| 166 | "Supply, fixing and wiring of surge protection device in attachment plug module with replaceable surge protection for coaxial signal, interfaces N-connector plug/socket installed as surge protection between antenna and 25 W VHF sets, make- Phoenix Contact model CN-UB- 280DC-SB-28 18148 or similar as per specifications. this includes mounting plate and reserve gas filled surge arrestor (one no.) with all required connectors /clamp for commissioning of SPD at site. Inspection: Consignee" | Numbers | 5.00 | 6,985 | 34,925 |
| 167 | "Installation, testing and mounting of G.P. antenna on a GI pipe which is to be fitted on the roof of equipment room and lightning arrestors also to be mounted on a GI pipe. All fixing materials to be supplied by the tenderer and left over material to be returned to the railway store. N.B.G.P. Antenna, GI pipe(50 mm dia) and lightning arrestor will be supplied by the railway." | Numbers | 1.00 | 6,190 | 6,190 |
| 168 | "Installation, testing & commissioning of operating panel room VHF/SIMPLEX VHF base equipment, DC-DC simplex VHF base equipment, DC-DC converter, buffer amplifier and laying of co-axial cable simplex VHF base equipment, DC- DC converter, buffer amplifier should be mounted on rack of suitable size and other fixing arrangement" | Numbers | 1.00 | 2,102 | 2,102 |
| 169 | "Laying of Power Cable/STP/UTP CAT- 6/LS cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly. Representative, including any fixing of cables/PVC pipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junction etc. shall be supplied by the contractor. This also includes transportation of cable, PVC Pipe, GI Pipe, HDPE Pipe etc. to the site." | Metre | 2000.00 | 19 | 38,000 |
| 170 | "Supply, installation commissioning of 500-watt Amplifier Make Ahuja model SSA 5000EM.or Similar.Inspection: Consignee." | Numbers | 2.00 | 26,535 | 53,070 |
| 171 | Supply of high-fidelity PA horn speaker IP-65 rated model AMH-402T, make Ahuja or similar. | Numbers | 10.00 | 6,113 | 61,130 |
| Schedule total | ₹8,18,55,996 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IRGCCApril2022.pdf
ATTACHMENT
ACS1GCC2022MiscincludingPVC.pdf
ATTACHMENT
ACS2GCC2022AnnexureVVA.pdf
ATTACHMENT
ACS3GCC2022POA.pdf
ATTACHMENT
ACS4GCC2022AnnexureV.pdf
ATTACHMENT
ACS5GCC2022ManualBGSubmission.pdf
ATTACHMENT
ACS6GCC2022GST.pdf
ATTACHMENT
ACS7GCC2022Tenderformfirstsheet.pdf
ATTACHMENT
ACS8terminationnotice.pdf
ATTACHMENT
ACS9PGrelated.pdf
ATTACHMENT
ACS10Arbitration.pdf
ATTACHMENT
ACS11_compressed.pdf
ATTACHMENT
ACS12Arbitrationandminoritemsvariation_compressed.pdf
ATTACHMENT
LLHApprovedSIP.pdf
ATTACHMENT
LILUAHEIBUILDING_APPROVE_P24.pdf
ATTACHMENT
TenderDocument.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .