Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC | L1 | Accepted-AOC rates are reasonables |
Tender Value
₹3.3 L
EMD Value
₹6,600
Closing Date
15 Sept 2020, 4:00 pmClosed
AS PER BID DOCUMENT
AS PER BID DOCUMENT
Providing Improved Access to Water through Household connections in existing Water Supply Scheme KAPOORI of Block-Bhunerheri, Distt Patiala
2020_WSS_53244_1
E-TENDER-11/WSSD/Mech Patiala/2020-21
Open Tender
Civil Works
Item Rate
60 days
AS PER BID DOCUMENT
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
TIA
₹6,600
4 Aug 2021
10 Sept 2020
16 Sept 2020
10 Sept 2020
15 Sept 2020
10 Sept 2020
Amount
Component -1
Repair of Control Panel Board complete with all respect.
Repair of Pump Chamber
Applying Pink Primer or-aluminium priming coat including preparation of surface With special quality paint for door, window, ventilator & cup board etc. complete with all respect.
Painting two coats excluding priming coat with ready mixed paint in all shades on old wood work With special quality paint Qty. as per item No. 19
Applying priming coat with methal primer on new steel or iron work incluing preparation of surface and Painting two coats with ready mixed paint for metallic surfaces in all shades on steel or iron work with special quality paint for grills in window, ventilator & R.S. joint on roof complete with all respect.
White washing 3 coats inside of pump chamber complete in all respect.
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of Paris and chalk mitti including finishing the surface to the required finish complete. Inside pump Chamber.
Distempering with dry distemper of approved manufacture two coats over one priming coat to give an even shade. Qty as per sr No 36
Supplying & fixing glass panes of ventilator and windows including special metal sash putty of approved make for ventilator & windows inside the Pump Chamber complete with all respect.
Providing and fixing of ceiling fan of reputed make such as Crompton or equivalent
Providing and fixing of electric tube set of reputed make/ISI make.
Repair of OHSR
One No. RCC OHSR 10000 ltrs capacity having height 25.00 mtr up to FSL has been already exists at site. The Repair of OHSR has been taken in this estimate.
Painting of C.I Pipes and Specials complete in all respects
Repair of expansion joint
Repacement of Sluice valve
Credit
Cost of chlorination Plant required
Cost of Minor repair/Leakage & replacement of pipe associated with repair.
Cost of automated water Controller
Water Works
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 (as per Analysis A-6)
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8 & (as per Analysis A-6).
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7 & Analysis A-7
Component -2
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE pipe lines 15mm i/d=2.00 mtr & G.I. Pipe lines 15mm i/d = 2.50 mtr including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with C.I. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete (On Existing Pipeline)
Component-3
Providing proposed water connection on new pipeline to house hold up to wall with providing, laying jointing, testing MDPE pipe lines 15mm i/d=2.00 mtr & G.I. Pipe lines 15mm i/d = 2.50 mtr including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with C.I. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete (On New Pipeline)
Providing, Stringing out PVC pipes 6kg/cm2 ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete as per specifications, cost of earth work in excavation & back filing complete with all respect.
Dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects.
Dismantling of Brick of edge.
Component-4
Painting & Printing of sign board as per DWSS Specifications.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .