| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹9.8 L+₹23,897.69 (2.50%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L2 | Rejected-Finance BEING HIGHER THAN L1 BID | |
| 3 | L3₹10.4 L+₹86,762.69 (9.08%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L3 | Rejected-Finance BEING HIGHER THAN L1 BID | |
| 4 | L4₹10.5 L+₹92,221.69 (9.65%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L4 | Rejected-Finance BEING HIGHER THAN L1 BID | |
| 5 | L5₹10.9 L+₹1.3 L (14.0%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L5 | Rejected-Finance BEING HIGHER THAN L1 BID |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
15 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (CGN) kolkata
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
ADDL/ALTR TO EXTERNAL ELECTRIC AND WATER SUPPLY, SECURITY LIGHT, GARDEN LIGHT INCLUDING CERTAIN CONNECTED ITEMS AT TS BAGJOLA UNDER GE (I) (CGN) KOLKATA
2022_MES_525495_1
8969/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (CGN) kolkata
AS PER TENDER DOCUMENTS
11 documents required · 11 mandatory
₹500
GE (CGN) kolkata
₹27,000
Yes
17 Aug 2022
21 May 2022
17 Jun 2022
21 May 2022
15 Jun 2022
8 Jun 2022
60 days
Amount
Supply & fix steel tubular swaged poles Type 410 SP-31 (9.0 metres long) complete with CI base plate and finial taper plug, nuts,boults,and screws with two holes for drawing conductor between pole box to street light fitting including painting with two coats of aluminium paint over one coat of primer incld Zebra marking with synthetic enamal paint and applying black bituminious paint to the buried surfaces in ground. (Note : Earth work,PCC wll be measured and paid separtely under relevent item of this schedule.
S&F in repair GI/ MS Bracket made of 40 mm dia GI/ MS pipe medium grade 1.5mtr long suitable for street light on steel pole as per site requirement including suitable nut,bolt and clamps complete accesseries all as specified and directed .
Taking down carefully old defective street light, flood luminaries, garden light any watt, from the pole, etc. complete all as specified and as directed.
S & F LED flood light luminaries 70 watt high pressure die-cast aluminium housing, toughened glass, IP66, with high power LEDs as light source and electronic driver as per Havells Cat Part No. JETAALBAFLOODLIGHT70W or equivalent of Crompton Greaves/ Philips complete all as specified and as directed.
Supply and fix LED street light 120 Watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver. Make : Havells cat part ENDURACITYLINERNEOSL120WLED757SASYBOTG or equivalent of Bajaj/Philips/Crompton.
S & F integral post top lantern Black ABS plastic spigot, integral, ovoid shape post top lantern with clear / opal acrylic with single LED lamp 25 W including connection with armoured cable of size 2 core 6 sqmm from FRP junction box and testing commissioning complete. Make : Havells cat part RUBYPT25WLED830SSYMTOPC or equivalent of Bajaj/Philips.
S & F integral post top lantern Black ABS plastic spigot, integral, ovoid shape post top lantern with clear / opal acrylic with single LED lamp 35 W including connection with armoured cable of size 2 core 6 sqmm from FRP junction box and testing commissioning complete. Make : Havells cat part RUBYPT35WLED757PSYMTOPC or equivalent of Bajaj/Philips/Crompton.
S&F LED bollard light 10W, Sturdy IP 65 LED Bollard with excellent light out put through its PMMA window ensuring maximum illumination aspect in surrounding complete all as sopecified and as directed. Make : Havells cat part MOUNTBL10WLED830PSYMTOPMMA or equivalent of Bajaj/Philips.
Taking old unserviceable pole mounted junction box of any size and any description removal to store or taken on schedule of credit complete all as specified.
S & F pole mounted junction box, size 300 mm X 200 mm X 125 mm made of FRP with connector for single phase supply and arrangement to fix MCB complete all as specified and as directed. Make: Sintex/ Universal/RMW.
S & F garden light pole mounted junction box, size 93 mm X 93 mm X 62 mm made of FRP with connector for single phase supply and arrangement to fix MCB complete all as specified and as directed. Make: Sintex/ Universal/RMW.
S&F in repair MCB SP, 10KA, 230V, C-curve, 6-32 amps complete all as specified and as directed. (Make; Legrand/ABB/SIEMENS)
Taking down old unserviceabl sub main wiring completewith any description complete all as specified and as directed.
Supply and fix wiring complete with and including three core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including HDPE pipe conduits of suitable nominal size as required at site but not less than 20 mm nominal size including all accessories complete all as specified and directed by Engineer-in-charge. Note - three core 1.5 Sqmm cable, one run of HDPE pipe conduit shall be measured and paid as one unit length.
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 2.5 sqmm cable, one run of 2.5 sqmm cable and one run of conduit shall be measured and paid as one unit length.
Excavating in trenches n. exc1.5 m wide and n.exc 1.5m in depth for foundation,etc or for shafts,wells,cesspits, manholes,pire holes,etc n.exc 10sqm on plan and not exc1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and as directed.
Removing excuvated soil not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtrs above the starting point in soil complete all as specified and as directed.
M&L for sand cushioning for protection of cable (below,above and around the cable laid in trenches) complete using clean ,dry sand complete all as and as directed.
Supply and laying well burnt bricks sub class "B" laid breadth wise along length of cable in trenches after sand cushioning laid for undergroung cable protection complete all as specified and as directed.
Laying only bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Taking up or down 50 mm bore of steel tubing and connections, including removal to store or taken on schedule of credit complete all as specified.
Supplying & fixing to walls and ceilings or laid in floors or trenches or stand for garden light, 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 1100 V, nominal cross sectional area of main conductor upto 25 sqmm, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) all as specified and directed by the Engineer-in-Charge.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning IN REPAIRS cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
M & L for fabrication of LT feeder pillar box, out door type, tent roof, CPRI approved factory made out of 3.15 mm thick CRCA sheet and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome prime in grey colour complete all as specified and as directed and comprising the followings:- INCOMING (a) MCCB, FP, 63 Amps capacity, 25 kA rupturing capacity- 01 No OUTGOING: (a) MCB, SPN, 40 Amps, - 04 (c) Digital timer -02 No. (d) Contractor ML-02- 02 Nos (e) Digital Ammeter, 0 to 200 Amps, flush mounted type square with CT ratio 100/5 - 03 No (f) Voltmeter, 0 to 500 volts, flush mounted type, square- 01 No (h) Indicating lamp RYB with holder - 01 Set (03 Nos) NOTE:- (i) Wiring of panel board with copper wire of suitable size and gauge with connector, copper lugs all as required at site. (ii) The rate quoted by tenderer also includes to fix the legs of the panel box in PCC 1:3:6 pot hole foundation 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm)
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete as in coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S&F 50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 as in gargen light stand including all accessories complete all as specified and as directed.
M&L for Preparationof old surface of 9.0 metre long pole and apply with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
S&F in repair to walls and ceilings or laid in floors or trenches, 50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S&F in repair to walls and ceilings or laid in floors or trenches, 80 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S&F in repair to walls and ceilings or laid in floors or trenches, 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M&L for cutting the existing hard standing/PCC road at a depth not less than 45 cm and 25 cm in width for passing of MS pipe of a dia 50/25mm dia making the good surface by providing cement concrete type B-1 (1:2:4) with 20 mm graded aggregate up to 20 cm finishing to a uniform smooth surface complete all as specified and as directed.
S & F in repairs 50 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F in repairs 25 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
Cutting /drilling the existing GI pipe 80/100 mm dia pipe including CI/DI/GI tee, bend,tapper etc all necessary items complete all as specified and as directed.
Cutting /drilling the existing GI pipe 50/40 mm dia pipe including CI/DI/GI tee, bend,tapper etc all necessary items complete all as specified and as directed.
M & L for construction of new valve chamber of internal size 600 mm X 600 mm X 600 mm including necessary earth work in any type of soil, PPC foundation (1:3:6) type C-2 40 mm grade stone aggregate as in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40 mm X 40 mm X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide prime on all metal works & three coats of white wash on all plastered surfaces of valve chambers complete all as specified & directed by Engineer-in-Charge.
RADHA ENTERPRISE
M/s Santosh Industrial Corporation
UNIVERSAL TRADING CENTRE
MS AP CONSTRUTION AND CO
INDIA ELECTRICAL EQUIPMENTS
SOMIK DAS
Globe Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .