Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹40.9 L+₹6.1 L (17.6%)Rejected-AOC D 2 212 JEEVAN PARK PANKHA ROAD UTTAM NAGAR WEST DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹41.6 L+₹6.8 L (19.5%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹44.0 L+₹9.2 L (26.5%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹45.2 L+₹10.4 L (30.0%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Mar 2023, 6:00 pmClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul kataria Chowk 122005
GE(P)AF/GUR-81/2022-23 SPECIAL REPAIR TO BLDG NO P-11 IT BUILDING AND CERTAIN OTHER SANCTIONED WORK IN VARIOUS UNIT AT AF STATION PALAM UNDER GE (AF) GURGAON NO 1
2023_MES_578213_1
GE (P) AF/Gur-81/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Gurgaon No 1
as per NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹90,000
Yes
13 Mar 2023
31 Jan 2023
3 Mar 2023
31 Jan 2023
1 Mar 2023
15 Feb 2023
Amount
Dismantling of existing roof treatment of any description/thickness including dismantling of water proofing plaster etc complete all as specified and as directed by Engr-in charge.
M&L for PCC 1:2:4, type B-0, using 12.5mm graded stone aggregate as in coping, benching, roof padding as levelling course complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm thick cement plastering in CM 1:4 on brick/concrete surfaces of roof and parapet, mixed with water proofing compound, finished even and smooth without using extra cement (Including 4 Story building) complete all as specified and as directed by Engineer-in-Charge. Note :- Water proofing compound shall be measured & paid separately under respective item of schedule.
Supply only liquid water proofing compound complete all as specified and as directed by Engr-in charge.
Cleaning top surfaces by brooming, wire brushing, removing grass, raking out joints to receive plaster and removing debris, grass etc outside the defence land complete all as specified and directed by Engineer-in-Charge. Note :- 1. Plaster shall be measured and separately under appropriate item of Sch ‘A’. 2.Rate of this item is inclusive of diconnect fitment at water tank or solar heater etc and refixing in the same position after compeleting of roof treatment.
M&L for applying 3.00mm thick APP based polymer membrane over 85/25 industrial bituminous coat @ 3 Kg/Sqm over bituminous primer @ 0.30 Ltr/Sqm on newly plastered clean and dry roof surface. Top surface shall be finished with bituminous base Aluminium paint, all joint shall be Sealed by torch application complete all as specified & as directed by Engr-in-charge.
M&L false ceiling of approved (ISI marked) make with 4mm thick HPS board fixed to galvanised iron steel angled grid 600x600mm size suspended system fixed to MS framed work of approved make and section as specified in SSR Part I with suitable hook/fasteners and GI/almn suspenders not less than 3mm dia @ 1.00m C/C minimum. ceiling system is to be fixed in water level without any sag and dismantling old ceiling board with frame complete all as specified and directed by Engr-in-Charg
M&L rendering 15mm thick in cm 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement incl taking down cement plaster or concrete, brick surface and raking out hacking for key scrubbing down with water to receive plaster complete all as specified and as directed by Engr-in charge. Note: plaster shoud be ready mix and The work to be executed at the height of 12 to 15 mtr the rate for necessary scaffolding deemed to be included in the qouted rate.
M&L for 5mm thick rendering in CM 1:3 on concrete/gunniting surface as in ceiling finished even and smooth without using extra complete all as specified and directed by Engr-in-charge
S&F 500 Litre capacity of rotational moulded polyethylene water storage tank (Cylindrical vertical with closed tap) hoisted and fixed in position including S&F 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug ;and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings and including dismantling of tank complete all as specified and as directed.
S&F 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastec ball screwed for iron pipe and fixed complete all as specified and as directed.
Taking up or down existing steel tubing/PPR pipe of size 15mm bore and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down existing steel tubing/PPR pipe of size 20mm bore and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Supply & fixing, jointing and testing galvanized iron tube medium grade of size 15mm dia bore with all fittings such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floors complete all as specified and as directed.
Supply & fixing, jointing and testing galvanized iron tube medium grade of size 20mm dia bore with all fittings such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floors complete all as specified and as directed.
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately)
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
Taking down Cement Plaster or old grit wash, any description on Brick Walls or on Concrete Surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. (4th floor and scafolding)
M&L applying Two coat of distemper oil emulsion and wall care putty on new decorated surfae of walls incl preparation of surfaces by washing rubbing down and stopping of distempered surfaces all as specified. ( Note :- All holes/cracks to be filled with birla putty and making good to old surface)
M&L applying Two coat of distemper oil emulsion and ceiling care putty on new decorated surfae of ceiling incl preparation of surfaces by washing rubbing down and stopping of distempered surfaces all as specified. ( Note :- All holes/cracks to be filled with birla putty and making good to old surface)
M&L preparation of old decorated surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots etc and applying one coat of distemper oil emulsion and ceiling care putty on old decorated plastered surfaces of ceiling complete all as specified and as directed by Engr-in charge.
M&L preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots etc and applying one coat of distemper oil emulsion and ceiling care putty on old decorated plastered surfaces of wall complete all as specified and as directed by Engr-in charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm and but n,exc 4 sqm each for archives soffits, linings window boarss etc complete all as specified and directed.
S & F for anodised aluminium frame (minimum 50 micron powder coating) for doors windows ventilators with one or more rebates including cleat for fixing etc complete all as specified and directed by Engr in charge
S & F Aluminium powder coated of any colour (thickness or powder coating not less than 50 micron) doors shutters aluminium saction weighing 0.55 Kg/Sqm including necessary jointing cleats glazing clips rubber neoprene packing hangles two nos in each door hinges anodised aluminium snap beading screws complete all as specified.
S & F aluminium powder coated of any colour (thickness or powder coating not less than 50 micron) windows and ventilator shutters with aluminium grill side hung type without sash bars aluminium section weighing 0.55KG/Sqm including necessary jointing cleats glazing clips rubber packing anodised snap beading screws anodised aluminium fitting such as peg stay 150 mm long (01 No) hinges type B2 100 mm long(02 No) suitable handle (01 No) complete all as specified and directed.
S&F 12mm thick prelaminated particle board interior grade prelaminated both side with decorative choice lamination fixed with screws to timber frame work or as in cubicals, partition or cupboards, complete all as specified and directed by Engr-in-Charge.
S&F double action floor spring hydraulically regulated made up of aluminium 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed by Engr-in charge.
S & F stainless steel wire cloth (SS304 grade) 0.36 mm nominal dia of wire and average with of aperture 1.40 mm and fixed with stainless steel wire staples with wooden/aluminium beads/screws to window/door complete all as specified and as directed by Engr-in charge.
S & F 4 lever brass mortic lock,vertical type , size 100 mm complete all as specified and as directed by Engr-in charge.
S & F MS Framed work such as grills, gratings, with ornamental & intricate design for windows, ladder, spiral stair case etc, with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars, incl hinges, framed balusters, walk ways; railings & similar work conforming to Fe 290 GDE -E-165 complete all as specified and as directed by Engr-in charge.
M&L for applying two coats synthetic enamel paint over a coat of red oxide/zinc chrome primer including preparation of new steel/iron surfaces exc 10cm in width or girth all as specified and as directed by Engineer-in-charge.
M&L for applying one coat high glass synthetic enamel paint including preparation of old steel/iron surfaces exc 10cm in width or girth complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work or stone/boulders masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etac but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-charge
Dismantling of floor, hearth or wall tiling including cement morter bedding (but not backing), removing serviceable tiles to the stores and rubbish off the premises complete all as specified and as directed by Engr-in charge..
M&L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match Laid on floor, over and including 15mm thick screed bed in cement mortar 1:4 Laid and Jointed in Neat Cement Slurry and pointed in White Cement with pigment to match the shade of the Tiles, complete all as specified and as directed.
Removal of debris/malwa to a distance exc 10 Km but n exc 15.00 Km out side MD land and depositing where as directed complete all as specified and as directed by Engr-in charge..
Demolition of cement concrete (unreinforced) concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified as directed.
Pre construction Anti termite treatment for filling under floor/Plinth Protection by using CHLROPYRIPHOS 20% EC emulsion @5.00Ltr/Sqm complete all as specified and directed.
Pre construction Anti termite treatment along the outer periphery of building by using CHLROPYRIPHOS 20% EC emulsion @2.25 0Ltr/Rm complete all as specified and directed.
M & L for 100mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 15mm thick screed bedding layer in CM 1:4 for laying in floor etc complete all as specified and as directed by the Engr-in-charge
M&L Machine cut kota stone 15-20mm thick as in skirting over 10mm thick rendering in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and finishing with mirror polishing complete all as specified and as directed by the Engr-in-charge
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces including finishing even and smooth without extra cement all as specified and as directed by Engineer in Charge.
M&L for 15mm thick rendering on brick or concrete surfaces in internal surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newely plastered Wall surface and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newely plastered ceiling surface and applying three coats of white wash complete all as specified and directed.
M&L for preparing new plastered walls surface and applying two coat of exterior emulsion paint 100% acrylic of approved colour over a coat of primer including 1 to 2 mm thick birla putty punning complete all as specified and directed by Engineer-in-charge. Make-Asian (Apex Ultima) paints/Berger (Whether coat long life) including necessary scaffolding upto 4th floor complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 Type C2 (using 40mm graded stone aggregate) as in plinth protection and court yard, finished cement surfaces even and smooth with out using extra cement in panels and providing grooves complete all as specified and directed.
Dimantling wought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F steel rolling shutters (thickness of laths in 1.25mm),without ball bearing,as specified including top cover,anchoring rod,hasps and staple and one shop coat of primer :erected in position as indicated complete but gear operated type with bevel gear box and cranck handle complete all as specified and directed.
S&F safety lever locks mild steel with 4 lever for rolling shutters complete all as specified and directed.
S&F ball bearing for rolling shutters complete all as specified and directed.
M&L for Complete removal of existing old treatment by scraping down with steel brush/steel patty preparing old plastered surface of walls and applying two coats of white wash complete all as specified and directed.
Dismantlign of asbestos cement sheet corrugated or semicorrugated etc in roof covering etc complete all as specified and directed.
S&F 0.50 mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and directed.
Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S& F MS framed work as in doors or gates of angle or other section as chowkhat., tie bar, hold fast, guard bars complete cooler stand etc, drilled for fixing complete Fe-410 complete all as specified and directed.
Complete removal of existing old treatment by scraping down with steel brush/steel patty preparing old plastered surface of ceiling and applying two coats of white wash complete all as specified and directed.
E/M Portion
Taking down copper/aluminium point wiring (light points) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for the above items should be made as per conditions seperately) and making good disturbed surfaces of walls. floors, etc. complete all as directed
Taking down copper/aluminium submain wiring complete, including conduits of any kind, and removing materials to store for keeping in safe custody or for taking credit (credit for the above items should be made as per conditions seperately) and making good disturbed surfaces of walls. floors, etc. complete all as directed
Taking down main switches, distribution boards etc of any type and capacity along with the existing boards, and removing the same from site and making good the disturbed surfaces/portion of walls etc. all as directed.
M & L for point wiring (concealed on wall & surface/concealed on cealing) for one light/fan/exhaust fan controlled by one modular/piano switch one way in different locations/building including rigid non metallic PVC conduit, medium grade, ISI marked , 20 mm dia, with 1.5 sqmm FRLS PVC insulated & unsheathed, stranded copper conductor of 1.5 sqmm as continuous earth connected to common earth dolly, complete all as specified and directed by Engr-in-charge.
All as per item No 67 above but for 5 Amps 5 Pin socket outlet on the same board complete all as specified and directed by Engr-in-charge.
All as per item No 67 above but one 5 pin, 5 Amp socket outlet on independent board not below the switch board of the light point in the same vertical plane complete all as specified and directed by Engr-in-charge..
All as per item No 67 above but One bell/buzzer point controlled by on bell push -ditto-.
All as per item No 67 here in before but using 4 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant low smoke ( FRLS ) cable for 1 5 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc including taking down of old u/s wiring required complete all as specified and directed.
All as per item No 67 above but one 5 pin, 15 Amp socket outlet on independent board for power point with 2.5 sqmm size copper wire -ditto-.
M&L for ceiling rose 63.5x23.5 mm 3 terminals, PVC/Polycarbonate, isolated body complete all as specified and directed.
S&F Modular switch, one way 6 Amps , 1 module complete all as specified and directed.
S&F Modular Socket , 6 A-2/3 Pin combined 2 module complete all as specified and directed.
S&F twin socket modular type heavyduty out let 6 pin 6/16 Amps 2 module, complete all as specified and directed.
S&F switch Modular type 16 Amps , single pole one way 240 volts one module complete all as specified and directed.
S&F Modular Fan step Regulator Bell ,120 W-2 module complete all as specified and directed.
M&L for metal flush box for fixing of switches for 1/2 module complete all as specified and directed.
M&L for metal flush box for fixing of switches for 3 module complete all as specified and directed.
M&L for metal flush box for fixing of switches for 6/8 module complete all as specified and directed.
Supply & fix Modular White cover plate with frame for 1/2 module complete all as specified and directed.
Supply & fix Modular White cover plate with frame for 3 module complete all as specified and directed.
Supply & fix Modular White cover plate with frame for 6/ 8 module complete all as specified and directed.
S&F Modular type blank plate , 1 module complete all as specified and directed.
S& F Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed.
S&F 5 watt LED bulb suitable for B22 base lamp complete all as specified and directed.
Taking down of serviceable ceiling fans/wall mounted fan and refixing the same on same position including cleaning and painting after the work is over complete all as directed.
Taking down of serviceable Exhaust fans and refixing the same on same position including cleaning and painting after the work is over complete all as directed.
Refixing only any type and capacity of tube light/ceiling light fitting of any type after the repair of the buildings on the same location complete all as directed.
Supply and fix PVC ventilating fan AC single phase 230/240 volts of size 200 mm sweep with louvers and connecting up including provision of cable from ceiling rose to connector to exhaust fan also including make suitable size hole on wall/window as per site requirement. Make : Havells/Bajaj/Usha/Orient/Orision or equivalent out of make specified in 'List of make'.
Supply & fix sheet metal enclosure for 220 volts 20 Amps with a three pin and earth plug top with socket and one single pole MCB 20 amps complete as well as specified and directed.
S&F DB Double door SPN 415 Volts 8 ways double door complete all as specified and directed. Make : Havells cat part no HDESHCDOW12 / Indoasian/ Legrand or equivalent out of make specified in 'List of make'.
S&F vertical type TPN 415 Volts Loadline DBs are fitted with Bus Bars, Neutral Links, Blanking Plates 06 way double door type DB suitable for upto 160 amps rating MCCB as incomer complete all as specified and directed.Make : Havells cat part no DHDLVDRWGOFO06/ Indoasian/Legrand or equivalent out of make specified in 'List of make'.
S & F MCB SP of rating, 06 to 32 Amp,240 volt, 10 KA 'B' Series type complete all as specified and as directed.
S & F MCB SPN of rating 40 Amp, 240 Volt, 10 KA, 'C' series type complete all as specified and as directed.
S&F in MCCB 3 Pole 415 V. adjustable type , 160 Amps with breaking capacity 36 KA .Make : Indoasian/Havells/L&T
S&F in 63 Amps RCCB - ‘AC’ Type (In accordance with IS 12640-1 & IEC 61008-1) 240 V/415 V, 50 Hz with 10 kA short circuit withstand capacity 100 mA.Make : Indoasian/Havells/L&T or equivalent out of make specified in 'List of make'.
M&L for concealed sub main wiring three run of 06 sqmm PVC insulated unsheathed copper conductor cable ISI marked 1100 volts grade drawn in and including PVC surface conduit suitable size of medium grade fixed on wall/ceiling/passing through wall etc connected as required at site complete all as directed. (For main DB to sub DB connection ) Note- (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit). (b) Make disturbed surface good to wall/floors as existing surface.
M&L for concealed sub main wiring three run of 04 sqmm PVC insulated unsheathed copper conductor cable ISI marked 1100 volts grade drawn in and including PVC surface conduit suitable size of medium grade fixed on wall/ceiling/passing through wall etc connected as required at site complete all as directed. (For AC and DB connection ) Note- (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit). (b) Make disturbed surface good to wall/floors as existing surface.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to 4 mm dia galvanized earth wire by means of bolts, nuts, check-nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 (duly protected with 15 mm dia light grade GI pipe upto 7.5m from the earth plate) and connected to GI steel earth plate including charcoal, dust, common salt, necessary excavation in soft/loose soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m from the starting point, watering pipe 20 mm bore GI tube of light grade treated with 1 No PGI funnel, pit of PCC 1:2:4 type B-1/ RCC 1:2:4 type B-1, pit cover 75 mm thick reinforced with 6 mm dia bars @ 75 mm c/c both ways and with MS handle 12 mm dia connected to earth test point including testing complete all as specified and directed.
S&F in replacement of 4 ft 18/20 watt Decorative ultra slim aluminium LED lighting fixture with high lumen output, environmental friendly, energy complete all as specified and by Engr-in-charge. Make:- Havells/Orient/ Bajaj/Philips/CG or equivalent out of make specified in 'List of make'.
S&F in replacement of 2 feet 09/10 W slim LED battern (cool day light) Basic all purpose surface and wall mounted with polycarbonate housing & integrated with electronic driver complete all as specified and directed .Make:- Havells/Orient/ Bajaj/Philips/CG or equivalent out of make specified in 'List of make'.
Supply and fixing 25 watt LED street light fitting including with suitable size mounting bracket complete all as specified and directed by Engr-in-charge. Make : Havells/Crompton/Bajaj / Eveready or equivalent out of make specified in 'List of make'.
S&F 36 W LED recess mounting fitting(2' x 2') CRCA powder coated having polycarbonate diffuser powedered by independent electronic LED driver haing IP 20 protection,CCT 6000 K,230/240 VAC,lumen efficacy > 140 lm/w including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and as directed.Make:- Havells/ Philips/ GE/Bajaj/ Eveready or equivalent out of make specified in 'List of make'.
Supply and fixing cable jointing kit for 1.1 KV grade vable for straight through joint complete with jointing material heat Shrink type and accessories suitable 3.5 / 4 core XLPE, armoured, Aluminium conductor cable of size 95 sq mm complete all as specified and as directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 mm 3.5 core for signal centre centralised AC plant complete all as specified and as directed.
Supplying, laying or fixing, PVC insulated screened PVC bedded, galvanized steel strip or wire armored electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of 35 sqmm 4 core complete all as specified and as directed.
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
Supply and laying sand in trenches for protection of cable sand cushioning to cable 8 cm thick below cable and 15 cm thick above cable in layers all as specified and as directed. Note: - Compacted / punned thickness shall be measured for the purpose of payment.
M&L Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75 Old size bricks for the protection for underground cable complete all as specified and as directed.
S&F double door VTPN Distribution Board double door 4 Way IP43 with provision for 160 A MCCB as incomer & WiNtrip TPN MCB's as outgoing as per IEC 61439-3 for each phase with fully insulated busbar & shrouded Neutral bars complete all as specified and directed. Make: Havell's Cat No:DHDLVOBGSFE04 or equivalent in C&S/L&T/Legrand or out of make specified in 'list of makes'
S&F MCCB 3 Pole .415 V. fixed type 160 Amps with breaking capacity 36 KA suitable for above item double door VTPN DB 4way as a incommer complete all as specified and directed.
Supply and fixing GI pipe Light grade 40 mm bore (ISI marked) laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge. (Note:- Necessary excavation and earth work shall be measured and paid for separately)
Supply and fixing 415 V 10 kA 'B' curve MCB TPN 40 amp complete with connection , testing and commissioning and as directed. (Make-L&T/Havells/Indoasian or equivalent out of make specified in 'List of make')
M&L for sub main wiring 4 run of size 10 sqmm PVC insulated electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with, 1X10 sqmm PVC insulated copper conductor earth wire in concealed PVC conduit (4 run of 10 sqmm cable and one run of 10 sqmm wire and one run of PVC conduit will be measured as one unit) all as specified and directed.
Labour only for shifting XLPE cable from 400 KVA transformer to 160 KVA transformer main panel including all necessary arrangement complete all as specified and directed.
Supplying, installation, commissioning and testing LT panel 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel of suitable size , platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :-
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr-in- Charge.
Earth continuity conductor or main earthing lead fixed to wall or buried in ground or fixed to poles for loop earthing etc. as required 32 x 6 mm galvanised iron strip complete all as specified and directed by Engr-in- Charge.
S & F IP 68 protection single phase centrifugal monoblock pump of capacity,2 HP 240 volts, Head Range: Up to 42 metres Discharge Range: Up to 9.7 LPS Power Ratings: 0.37 to 1.5 kW Voltage Range : 160 to 240 volts and suction and discharge range 40 mm x 32 mm complete all as specified. Make : Kirloskar/ Crompton Greaves/KSB
S& F DOL stator panel with sheet metal enclosure suitable for 2 HP single phase 240 volts centrifugal Monoblock pump with suitable voltmeter , amphere meter complete all as specified. Make : Kirloskar/ Crompton Greaves/KSB
S& F 4.0 sqmm three core PVC insulated and FR PVC Round Sheathed, Copper Conductor cable, 1100 Volt, conforming to IS 694 complete all as specified. Make : Havells/Polycab/Plaza
M&L for mild steel work as in bands , straps, supports or stays for rainwater, ventilating pipes, incuding bolts, hooks (stay) heavy for large gates (as required) , hook and pintle hinges large hasps and staples, chains hand made sliding bolts, clamps hold fasts wall ties hooks for hanging fans, plain agnle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles confrirming to Fe-290 Gde-E-165 complete.
Cutting bituminous road surface not exc 30 cm in width and getting out for taking up/laying pipe etc complete all as directed.
Supply and fixing GI pipe Light grade 32 mm bore (ISI marked) laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge. (Note:- Necessary excavation and earth work shall be measured and paid for separately)
M&L for Cutting existing steel tubing for insertion of new pipes in new tees, branches etc complete of size 25 or 32 mm bore complete all as specified and directed. (Note: Each cut to be measured for the purpose of payment.)
S & F 40 mm dia Gun metal , globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6 metre mean radius built in cement motor 1:4 for motor foundation complete all as specified and directed.
M&L for plain cement concrete type B1 (1:2:4) (using 20mm graded aggregate) as in coping of poles even and smooth finishing using extra cement etc complete all as specified and directed.
Labour only for taking out unserviceable DBs by carefully disconnecting the existing connections, complete all as specified and directed
Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make :- Havells/ Crompton/ Phillips/ Eveready or equivalent out of make specified in 'List of make'.
Supply and fix in replacement of factory made epoxy polyster powder coated VTPN distribution board Triple pole and neutral 4 way 415V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for 100Amps MCCB as one incommer and 12 outgoings single pole MCB complete all as specified and confirming to IS: 8623 Make: Legrand /Siemens/Schneider. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
Supply and fixing MCCB 4 Pole, 415 V, fixed type, 100Amps with fixed Thermal & Fixed Magnetic setting | Ics = 75% of Icu and breaking capacity 16 KA complete all as speified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50.0 sq mm 3.5 core complete all as specified and as directed.
S&F in repair GI pipe light grade 80mm bore in trenches/wall/poles for protection of cable complete all as specified and as directed.
M&L for carrying out horizontal boring below roads/PCC hard standing/Drain suitable 80 mm dia GI pipe as per site requirement for inserting GI pipe of 50 mm size with a depth upto 1.5m & length of road upto 12m complete all as specified and as directed.
Note:- The amount of Rs 57251/- against Schedule of Credit on Page No 146 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
SACHDEVA ENGINEERING WORKS
P R Constructions
GIR RAJ BUILDERS
M/S Parshant Associates
M/S RK Builders
JAIPAL AND BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .