| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹13.5 L+₹90,916 (7.19%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | L3₹14.3 L+₹1.7 L (13.4%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest bidder | |
| 4 | L4₹15.1 L+₹2.5 L (19.8%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest bidder |
Tender Value
₹18.4 L
EMD Value
₹36,800
Closing Date
28 Feb 2022, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur
ADDN ALTN TO EXISTING DENTAL CENTRE (BLDG NO. P-34) AND PROVN OF AUTOMATIC FHASE SEQUENCE CORRECTOR PANEL AT MRI CENTRE AT 7 AFH KANPUR CANTT
2022_MES_502807_2
GE(AF)/CHK/T-44 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
7AFH Kanpur Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹36,800
Yes
28 Apr 2022
9 Feb 2022
4 Mar 2022
9 Feb 2022
28 Feb 2022
14 Feb 2022
Amount
Demolition of Stone slabs and tiles laid bedded and pointed in any cement mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
M & L for Glazed ceramic tiles og size 350mmx 250mmx 7 mm/ 450mmX 350mmX 7mm thick as in verticle surfaces laid over and including 15 mm thick screed bed in CM (1:3) and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
M&L for non skid ceramic coloured joint free tiles 7 to 8 mm thick square or rectangular of size exceeding 0.11 but not exceeding 0.18 sqm as in floors laid over and including 15 mm thick screed bed in CM (1:6) jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles including dismantling of old tiles and removing the same from site, complete all as specified and directed.
M & L for Non - skid coloured Ceramic tiles 7 to8 mm thick area of each tile exceeding 0.18 sqm but not texceeding 0.38 sqm as in floors etc laid over and including 15 mm thick screed bed in CM (1:6) set and jointed in neat white cement slurry and pointed in white or coloured cement to match shade of tiles complete all as as specified and as directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Demolition of Reinforced cement Concrete of any description and in any position not otherwise specifically provided for complete as all specified and as directed.
Providing and erecting props about 3.68 mtr height (minimum capacity 1 ton ) to support the structure provisionally during repair etc. and maintaing them in position till required complete all as specified and as directed.
M & L for providing PCC (1:2:4) Type B1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, Bed plates water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M & L for mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe- 410-W (Grade E-252) complete all as specified and as directed.
M & L for Brickwork with fly ash modular bricks straight or curved on plan exceeding to any radius built in CM (1:6) complete all as specified and as directed.
M & L for 20 mm thick (of any type) Granite work(table rubbed and polished) for wall lining (veneering to wall) over and including 12 mm thick in CM (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Taking down Cement Plaster of any description on Brick Walls or on Concrete Surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the premises MD land complete all as specified and as directed.
M & L Rendering 15mm thick in Cement Mortar (1:6) on Fair Faces of Brick Work or Concrete Surfaces, finishing the Surfaces Fair and Even, complete all as specified and directed.
M & L Rendering 15mm thick in Cement Mortar (1:4) on Fair Faces of Brick Work or Concrete Surfaces, finishing the Surfaces Fair and Even and applying two or more coat coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade(company depot tinted) with silicon additive @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm surfaces complete all as specified and as directed, complete all as specified and directed.
M & L Rendering 10 mm thick in Cement Mortar (1:3) on ceiling Fair Faces of Brick Work or Concrete Surfaces, finishing the Surfaces Fair and Even and applying two coats of white wash after preparation of surfaces complete all as specified and directed.
M & L for preparing newly plastered surfaces of walls and applying two coats of white wash complete all as specified and directed.
M&L for preparing New Plastered Surfaces of WALLS and applying TWO COATS of DISTEMPER OIL EMULSION (OIL BOUND WASHABLE DISTEMPER) over a Coat of CHALK WHITING, complete all as specified and as directed.
M & L for Complete removal of existing treatment i.e. white wash ,colour wash ,distempering etc. of wall and applying TWO COATS of DISTEMPER OIL EMULSION (OIL BOUND WASHABLE DISTEMPER) over a Coat of CHALK WHITING, complete all as specified and as directed.
M & L for preparation of old surfaces of walls and applying two coats of OBD complete all as specified and directed
M & L for applying two or more coat coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade(company depot tinted) with siliconadditive @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm after complete removal of existing treatment i.e. white wash ,colour wash , distempering etc. of wall complete all as specified and as directed.
M & L for preparing old undecorated surface of ceiling and applying two coat of white wash complete all as specified and directed.
Dismantling false ceiling boards (fibre, pulp, insulation, etc.of any thickness, including cover fillets complete all as specified and directed.
M & L for mineral fibre false ceiling system having size 600 mm x 600 mm x 16 mm thick of pattern classic lite RH 99 (bevelled tegular) of approved make and model including grid system using hot dipped galvanised steel section, exposed surface with pre-powder coated capping, main runner and cross runner and to comprise main tee/runner 15mm x 38 mm size (load carring capacity 14 kg/sqm) spaced @ 1200 mm c/c securely fixed to the structural soffit and flush fitting 1200 mm long cross tee/runner to be interlocked between main runners at 600 mm centre to centre from 1200mmx 600 mm module, cut sub cross tee/runner 600mm require independent support. Wall angle of size 19mm x 19mm, secured to the periphery of the wall at 450 mm maximum centres. The above grid is suspended at every 1200 mm centre to centre in both direction and starting from wall at the distance 350 mm from wall by using 3.50 mm dia aquiline wire with suitable fasteners and hooks clips complete all as specified and directed.
S & F in repairs 15mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length, complete all as specified and directed
S & F in repair 20mm bore tubes medium grade galvanized with all fitting fixed to walls and ceilings or laid in floors of any length , complete all as specified and directed
S & F in repairs Gun-metal, globe or gate valves of 15mm dia, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S & F in repairs Gun-metal, globe or gate valves of 20mm dia, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
Dismantling of old water tank exceeding 250 Ltr & not exceeding 500 Ltr capacity and supply and and fixing, hoisting PVC water storage tank of 500 ltr capacity including 20mm dia PTMT ball valve high pressure with epoxy coated alm rod & high density plastic ball screwed for iron pipe complete all as specified and directed.
S & F in repairs vitrous china water closet (pedestal pan) coloured completely and connecting to flushing cistern and seat cover PVC with flat recessed bottom with chromium plated or aluminized hinges devices complete all as specified. (Note: coloured PVC cistern will be measured saperatly ).
S & F in repair vitreous china wash hand basin , white flat back size 550mm x 400mm excluding chain and plug and porcelain stopper but including brackets including 32mm bore CP based fittings and PVC waste pipe suitable for 32mm bore pipe complete all as specified and as directed.
S & F in repairs 1mm thick stainless steel sink as in kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S & F in repairs 10 ltrs Flushing cistern capacity PVC valve less, symphonic action type, low level, white, with inlet, ball valve, float and handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed.
S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections complete all as specified and directed.
Supply and fixing vitreous china squatting pan 'Orrisa pattern' size 580mmx440mm white with integral foot rests any pattern including provn of cement mortar bedding and making connection including PVC s Trap, etc complete all as specified and directed.
S & F in repair Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
S & F for Waste coupling in urinals of PTMT (half or full threaded) .(Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and as directed.
S & F in repairs PVC connection 15mm dia and 45 cm long with 2 Nos PTMT nuts, complete all as specified and directed.
S&F in repairs 15 mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe complete all as specified and directed.
S & F in repair 15 mm bore anlge cock, cast copper alloy chromium plated, screwed down, high pressure, with capstan screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repair 15 mm bore fancy type CP bib taps cast copper alloy chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
M &. L for cutting chases for concealed water tubing and making good in CM(1:3), cutting not exc 10 CM girth in brick wall complete all as specified and directed
S & F in repairs 110mm bore PVC (SWR) pipe single socket in any length with rubbepr ring joints fixed to walls with MS flat iron clamps of size 50 x 6mm and 16mm dia round bar stay of required shape and size inclduing drilling holes and embedding in CM (1:3) and surface finished smooth complete all as specified and directed.
S&F PVC (SWR) bends 110 mm bore complete all as specified and as directed.
Demolition and breaking up 75 to 110 mm dia PVC drain pipes set in cement mortar complete all as specified and directed.
Supplied and fixed 100 mm bore CI soil waste & vent sand cast pipe in any length with or without ears, with cement joints laid in floor/trenches complete all as specified & directed.
S & F 100 mm bore CI soil waste & vent sand cast pipe in any length with or without ears, with cement joints laid on walls with MS flat iron clamps of size 50mmx6mm and 16mm dia round bar stay of required shape and size inclduing drilling holes and embedded in CM (1:3) surface finished smooth complete all as specified & directed.
S & F 75 mm bore CI soil waste & vent sand cast pipe in any length with or without ears, with cement joints laid in floor/trenches complete all as specified & directed.
Supplied and fixed CI soil waste & vent sand cast pipe in any length with or without ears, with cement joints 75 mm bore laid on walls with MS flat iron clamps with 50x6mm and 16mm dia round bar stay of required shape and size inclduing drilling holes and embedded in CM (1:3) surface finished smooth complete all as specified & directed.
S & F CI bend 100 mm bore ( any radius ) diminishing pieces or tapers ( larger bore measured) complete all as specified and direced.
S & F CI bend 75 mm bore ( any radius ) diminishing pieces or tapers ( larger bore measured all as specified and direced.
S & F cast iron Floor trap 75 mm dia with CP grating including jointing to waste pipe fixed in PCC (1:2:4) type B1 using 20 mm graded stone aggregate complete all as specified and directed.
S & F CI vent cowl of size 75 mm dia complete all as specified and as directed.
S & F aluminium frame/shutter for doors/ windows/ ventilators/partition, aluminium section of any colour, including necessary joining cleat, glazing clips, rubber reoprene packing, handles 2 Nos in each doors/windows/vent, hinges 150 mm size for door and 100 mm size for window/vent , anodized aluminium snap boarding screws etc complete all as specified and directed.
S & F 12 mm thick pre-laminated particle board, 12mm thick interior grade, prelaminated both sides with decorative choice laminations fixed with screws in any position complete, all as specified and directed.
S & F rubber beading 75mm wide fixing with nail/screw, complete all as specified and directed.
S & F for Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed.
S & F for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters, walk ways, railings, framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for 3 mm thick Sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5sq. m in each pane complete all as specified and as directed.
M & L for 3 mm thick sheet glass ordinary quality and glazing with oil putty insquare but exceeding 0.5sq. m in each pane complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exceeding 1.5 sq. m each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) exceeding 1.5 & not exceeding 4 sq. m each, complete all as specified and directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. Square tube, fixing in opening as per specification & drawing complete all as specified and as directed.
S & F 30 mm thick Factory made solid panel PVC door shutter consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed.
S & F Butt hinges of size 75 mm cold rolled mild steel medium weight complete all as specified and directed
S & F aluminium anodised barrel tower bolts of extruded section, length of bolt in 150mm complete all as specified and directed.
S & F 150 mm size aluminium alloy, anodised, 150mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F in repairs galvanised mild steel wire cloth 0.56 mm in nominal dia of wire average width of aperture 1.18 mm and fixed with wooden beads to wooden joinery complete all as specified and directed.
S & F extruded anodised aluminium alloy handles fabricated type 100mm complete all as specified and directed.
Taking down carefully aluminium point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket etc and making good to disturbed surface of wall/floor etc complete all as specified and directed.
M & L for point wiring with 1.5 sqmm FRLS grade PVC insulated cable 1100 volts grade as per IS-694 stranded copper conductor cable drawn into and including PVC Conduit (not less than 20 mm wide) complete for concealled wiring with all fittings and acessories including MS sunk box of thickness 1.6mm and hylem sheet cover of 3 mm thick for mounting of switches, sockets, regulators, etc and 1.5 sq mm stranded copper conductor cable FR grade PVC insulated for earth continuity all as specified and directed for one light Point controlled by one Switch complete all as specified and directed.
Ditto all as per Ser item No 71 above but on Ceiling / Exhaust Fan point.
Ditto all as per Ser item No 71 above but for 5 Amps socket point on independent board.
Ditto all as per Ser item No 71 above but for 5 Amps socket point on same board controlled by another switch.
Ditto all as per Ser item No 71 above but with 2.5 sqmm cable for 15 amps socket outlet on independent board complete all as specified and directed.
Ditto all as per Ser item No 71 above but with 4 sqmm cable for 20/25 amps Power Unit on independent board complete all as specified and directed.
S & F ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body complete all as specified and directed.
S & F switch piano flush type, 6 Amps 240 volts single pole one way complete all as specified and directed.
S & F socket outlet, 5 pin 6 Amps, flush type.
S & F socket outlet 6/16 Amps, 6 in 1, flush type.
Supply and fix switch piano flush type,15/16 Amps 240 volts single pole one way.
Supply and fix fan regulator electronic type, rotary step, Socket type 240 Volt.
S & F in replacement Metal clad single pole and nutral enclosure with a two pin and earth plug and socket with one single pole MCB SP 20 Amp,240V complete all as specified and directed.
S & F in replacement Metal clad triple pole and earth enclosure with a three pin and earth plug and socket with one triple pole MCB TP 32 Amp,240V complete all as specified and directed.
S & F in replacement fluorescent tube light fitting complete energy efficient T-8 LED batten and integrated type signle tube 20 Watt, 4 ft long white complete with LED rod, LED driver and LED batten etc with all accessories pre wire and connecting up with copper three core flexible cord of min 1 mm size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting arrangement complete all as specified and directed.
M & L for replacement of lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
M & L for sub main wiring with three runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn into and including 25 mm dia PVC conduit concealled with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable multi stranded with copper conductor of size 4 Sqmm as continuous nuetral and earth wire (green in colour ) respectively, and connected to the terminal and common earth dolly complete all as specified and directed. (Note. Three run of cable and one run of PVC conduit concealled and one run of earth continuity wire shall be measured as one run unit)
M & L for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC conduit conciled with all necessary fittings and accessories and 01xrun of PVC insulated and unsheathed single core cable multi stranded with copper conductor of size 4 Sqmm as continuous nuetral and earth wire (green in colour ) respectively, run through PVC casing N capping and connected to the terminal and common earth dolly all as specified and directed. (Note. two run of cable and one run of PVC conduit concelled and one run of earth continuity wire shall be measured as one run complete all as specified.)
S & F VTPN DBs, double door, 440 volt, 4 way including incomming 125 Amp MCCB complete all as specified and directed.
S & F SPN DBs, double door, 240 volt, 8 way complete all as specified and directed. Make:- Legrand cat No. 607711/ Havells Cat No. DHDPSHODRC008/C&S Cat No. CSDBSPNDDA2+08/ Indo Asian Cat No. NSPN0008.
S & F in replacement Isolator TPN , 63 Amp 4 pole Isolator, 415 Volt complete all as specified and directed.
S & F in replacement Isolator TPN ,40 Amp , 415 Volt complete all as specified and directed.
S & F in replacement Isolator SPN , 63 Amp , 240 Volt complete all as specified and directed.
S & F in replacement MCB SP upto 30 Amp ,240 Volt complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode of size 600 mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip of size 25 mm x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to ear thing test point complete all as specified and directed including testing on completion including PCC type C-2 pit of (1:3:6) using 40 mm graded stone aggregate, RCC (1:2:4) Mix type B reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 40mm dia light grade GI pipe for earth strip of size 32 mm x 6 mm protection etc (Earthing result not more than 2 ohm and test result duly signed) complete all as specified and directed. ( Note : Earth strip having length 7.5 Mtr per earthing shall deemed to be included in unit quoted rates)
S & F 300 mm sweep Exhaust fan AC single phase 230/240V metallic body complete with all accessories including making connection by using three core flexible wire of size 0.50 sqmm and making holes, groting nut bolts in wall for exhaust fan complete all as specified and as directed.
S & F XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade cross sectional 70 Sqmm 3.5 core laid in trenches/ducts/encased in GI pipe/fixed to pole including taking out of existing unserviceable cable/OH conductor complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of UG cable including getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and directed.
M & L for spreading & leveling dry clean Ganga sand in trenches for cushioning of UG cable complete all as specified and directed.
M & L for sub class old size bricks in trenches for cable protection of LT cables complete all as specified and directed. (Note : Bricks must be layed across the cable)
supply, laying and testing cable XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 Sq mm 3.5 core laid in wall/floor and inside the GI pipe as required at site all as specified and directed.
M& L for earthing complete with galvanized steel earth plate electrode of size 600 mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip of size 25 mm x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to ear thing test point complete all as specified and directed including testing on completion including PCC type C-2 pit of (1:3:6) using 40 mm graded stone aggregate, RCC (1:2:4) Mix type B reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 40mm dia light grade GI pipe for earth strip of size 32 mm x 6 mm protection etc (Earthing result not more than 2 ohm and test result duly signed) complete all as specified and directed. ( Note : Earth strip having length 7.5 Mtr per earthing shall deemed to be included in unit quoted rates)
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of size 25mmx4 mm galvanised iron sttrip complete all as specified and directed.
M.M.V. CONSTRUCTIONS
M/s DKS Engineering Works
SAXENA BANDHU
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .