| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC PO VIKRAMKHAND ROAD LANE NO 05 HOUSE NO 16 ASSAM 788007 | CACHAR | ASSAM | 788007 | L1 | Accepted-AOC Being L1 bid | |
| 2 | L2₹25.8 L+₹28,634 (1.12%)Rejected-AOC | L2 | Rejected-AOC Being higher than L1 bid | |
| 3 | L3₹26.4 L+₹89,280 (3.50%)Rejected-AOC KALIBARI BAZAR TUPKHANA PART I PO ARUNACHAL P S SILCHAR DISTT CACHAR ASSAM 788 025 | SILCHAR | CACHAR | ASSAM | 788025 | L3 | Rejected-AOC Being higher than L1 bid | |
| 4 | L4₹26.8 L+₹1.3 L (5.16%)Rejected-AOC | L4 | Rejected-AOC Being higher than L1 bid | |
| 5 | L5₹26.9 L+₹1.4 L (5.64%)Rejected-AOC | L5 | Rejected-AOC Being higher than L1 bid |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Jan 2022, 6:00 pmClosed
GE SILCHAR
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
REPAIR AND MAINT OF EXTERNAL ELECTRIFICATION REPAIR TO FANS METERS GEYSERS AT VAIRENGTE AND LAILAPUR UNDER GE SILHCAR
2021_MES_490686_2
8668/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VVAIRENGTE AND LAILAPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹50,000
Yes
7 Feb 2022
4 Jan 2022
18 Jan 2022
4 Jan 2022
17 Jan 2022
12 Jan 2022
Amount
SCHEDULE 'A' PART- I Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out soft / loose soil complete all as specified and directed.
Returning, filling in, trenches including Spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of surplus soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed.
Material and labour for sub-class 'B' brick of size 230mm x 115mm x 75mm laid in trenches across the trench for cable protection complete all as specified and directed.
Supply and spread sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note : Thickness of sand cushion after punning down will be measured and paid.
Material and labour for providing plain cement concrete 1:2:4 type B1 using 20 mm graded crushed stone aggregates for fixing poles, stay assembly etc without chamfered angles and flat, sprayed, rounded or mitred tops including all necessary form work complete all as specified.
Material and labour for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (Over all length 9 metres long) confirming to IS-2713. Pole shall be painted with two coats of black bituminious paint throughout internally and externally up to planting depth, length from bottom and the remaining external protion shall be painted with two coats of aluminium paint over a coat of red oxide primer and numbering the pole with white paint alfa numaric letters on black patch fixed in repairs complete all as specified and directed. Note: Earthwork and PCC measured and paid separate Items.
Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint fixed in repairs complete all as specified and directed.
Supply and fix MCCBs 415V, 4 Pole adjustable type 63 Amps with breaking capacity 16KA fixed in repairs complete all as specified and directed.
All as per item No. 09 above but 100 Amps.
All as per item No. 09 above but 125 Amps.
Supply and fix MCCBs 415V, 4 Pole adjustable type 160 Amps with breaking capacity 36 KA fixed in repairs complete all as specified and directed.
All as per item No. 12 above but 200 Amps.
All as per item No. 12 above but 250 Amps.
Supply and fix on Load change over switch 100 Amps, 440 Volts, 4 Pole fixed in repairs complete all as specified and directed.
Supply and fix on Load change over switch 250 Amps, 440 Volts, 4 Pole fixed in repairs complete all as specified and directed.
Material and labour for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for LT, 20 cm x 15 cm size fixed in repairs complete all as specified and directed.
Material and labour for stay assembly complete with & including 20 mm dia stay rod, loop type insulator, stay clamps and all accessories as shown in electrical plate No. 1 of MES Schedule 2009, Part-I fixed in repairs complete all as specified and directed. Note: Excavation and concrete measured and paid separately.
Material and labour for aluminium conductor, steel reinforced stranded 7/1.6 mm as in repair complete all as specified and directed.
Supply and fix as in repairs LED security light 45 watts on existing pole complete all as specified and directed. Make: Havells Cat No. ENDURACITYLINERNEXGENSL45WLED757SASYBOPC or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
Supply and fix as in repairs LED security light 70 watts on existing pole complete all as specified and directed. Make: Havells Cat No. ENDURAPEARLPLUSSL70WLED757SASYTOPC or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
Supply and fix as in repairs LED flood light 50 watts on existing bracket complete all as specified and directed. Make: Havells Cat No. JETACOMPECTOFL50WLED757LTG or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
Supply and laying connecting and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional areaof size 10 sqmm 2 core, laid in trenches thorugh duct/pipeor along pole with suitable size of aluminium lugs complete all as specified and directed.
All as per item No. 23 above but 10 Sq mm, 4 core.
All as per item No. 23 above but 16 Sq mm, 4 core.
All as per item No. 23 above but 25 Sq mm, 3.5 core.
All as per item No. 23 above but 35 Sq mm, 3.5 core.
All as per item No. 23 above but 50 Sq mm, 3.5 core.
All as per item No. 23 above but 70 Sq mm, 3.5 core.
All as per item No. 23 above but 120 Sq mm, 3.5 core.
All as per item No. 23 above but 240 Sq mm, 3.5 core.
Cutting tree branches touching the overhead electic lines of lengths 2.5 mtr and girth not more than 0.015 mtr complete all as specified and directed.
Material and labour for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50 mm height, 65 mm dia for 550 volts grade fixed in repairs complete all as specified and directed.
Supply and fix electrical insulated synthetic rubber mat for laying infront of panels in sub station of size 2x1 mtr and thickness 25mm complete all as specified and directed.
Supply only aluminium lugs suitable for cable cross sectional area 10 Sqmm to 35 Sqmm complete all as specified and directed.
Supply only aluminium lugs suitable for cable cross sectional area 50 Sqmm to 150 Sqmm complete all as specified and directed.
Supply only aluminium lugs suitable for cable cross sectional area 185 Sqmm to 240 Sqmm complete all as specified and directed.
Material and labour for LED glow sign board made of 2 mm thick GI sheet on all sides, front side 10 ft x 2.5 ft shall be fixed with 4 mm PVC white colour sheet, rare side shall be openable for maintenance and arrangement for mounting drivers inside the box on which 35 LED letter board with ACP sheet box with all lighting arrangements, the size of box is 10x2.5x1.5 feet, the letter on board are "MES POWER HOUSE- 11KV MRS, AGE E/M VAIRENGTE" fixed in repairs complete all as specified and directed.
Material and labour for replacement of 6 mm dia steel wire rope ASIS 326 grade of high mast lighting system of height 15 mtr complete all as specified and directed.
Material and labour for oiling & greasing for servicing of motor, chain pully of 15 mtr high mast lighting system complete all as specified and directed.
Material and labour for oiling & greasing for servicing of motor, chain pully of 30 mtr high mast lighting system complete all as specified and directed.
Supply, installation, commissioning and testing LT feeder pillar boxes, outdoor type of size 0.60x0.60x0.45 mtr (approx) suitable size recommended by manufacturer cubical floor mounted type (IP-65 degree of protection) made out of 3.15 mm thick MS sheet duly powder coated on both sides, openable front & back door fitted with locking devices (with keys) including bus bar 200 Amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 Hz AC supply, cable entry boxes, cable gland including 50x50x6 mm angle iron frame 60 cm long duly painted with two coats at synthetic enamel paint over one coat of primer (bottom portion of the panel), grouted 30 cm in PCC foundation with & including earthwork in soft/loose soil 1:2:4 type C1 using 20 mm graded stone aggregates complete all as specified and directed.
Material and labour for replacement of earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than than 2.25 mtr deep below gound level with top edge of the plate not less than 1.5 mtr below normal ground level and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvanised iron or steel pipe medium grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh including all necessary excavation and earth and all shown in electrical plate No. 3 of MES Schedule Part-I of 2009 complete all as specified and directed.
All as per item No. 44 above but using galvanised iron strip 25 x 4 mm as earthing lead with 40 mm bore medium grade protection pipe.
Material and labour for applying one coat of aluminium paint on 9 mtr long steel tubular pole in position after preparation of surface of steel tubler pole including all fitted cross arms, clamp and nut, bolt etc including painting of black and yellow paint strips of 05 Nos of 30 cm wide strips or as ordered by Engr-in-Charge on pole up to 1.5 mtr high above coping level including numbering the pole of size 70 mm x 40mm by using stencil to the pole with black synthetic enamel paint (1st grade) 1.5 mtr above the ground level all as specified.
Supply& fix of First Aid box kit made out of MS sheet of approximate size 250 x 200 x150 mm comprising of all neceaary medicine amd marked with FIRST AID BOX , fixed to wall with suitable size of clamps & nuts-bolts complete all as specified and directed.
SCHEDULE 'A' PART- II Taking down carefully aluminium/copper point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixure such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Taking down Old sub main wiring including GI earth wire and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed by the Engr-in-Charge.
M&L for point wiring with single core PVC insulated cable of size 1.5Sqmm nominal area with multi-stranded copper conductor, 1100V grade FRLSH drawn through and including PVC non metatllic concealed conduit of appropriate size & 1.8mm wall thickness with all fitting and accessories including GI sunken box alongwith hylum sheet of required thickness for mounting switches/sockets etc of suitable size including 1.5Sqmm PVC insulated unsheathed single core copper conductor earth continuity wire connected to common earth dolly with proper colour coding for one light point/fan point/bell point complete all as specified and directed.
All as per item No. 49 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on Independent board.
All as per item No. 49 above but with stranded copper conductor 2.5 Sq mm (nominal area), two single core, PVC insulated and unsheathed cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.
Supply and fix switch piano flush type button single pole one way 5 Amps complete all as specified and directed.
Supply and fix switch socket combination 3/5 pin 5 Amps flush type complete all as specified and directed.
Supply and fix switch socket combination 5/6 pin 15 Amps 2 in 1 universal plate complete all as specified and directed.
Taking down carefully electric storage type water heater (Geysers) of any make and any capacity from its mounting place opening for inspection compete Including back plate heating element inner copper tank etc. De-scaling back plate and heating element by cleaning with Sulfuric acid/ de-scaling compound and re-assembling of Geysers after repairs carrying out and re-fixing in same position (Replaced items such as spares measured and paid separately)in relevent item including making good to walls with CM (1:3) or PCC (1:2:4) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc all as directed . Note :- Any type of rubber gasket , rubber washer, screws , insulator tape required in work deem to be included in the quoted rate.
All as per item No 56 herein before but for descaling / cleaning the inner tank including denting and brazing the leakage joints / points till the leakage stop including carrying out minor repair of outer body surface, bottom and top cover complete all as specified and as directed. Note :- Any damage if occured during the process of cleaning the geysers will be made good by contractor at no extra cost.
S & F stainless steel inner tank heavy duty in replacement of copper / steel inner tank housing pressure bearing capacity suitable to the existing 25 ltrs Cap Geysers.
All as per Srl Item No 57 herein above but 50 Ltrs geysers complete all as specified and directed.
S & F of top cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 25 Ltrs geysers complete all as specified and directed.
S & F of top cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 50 Ltrs geysers complete all as specified and directed.
S & F of Bottom cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 25 Ltrs geysers complete all as specified and directed.
S & F of Bottom cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 50 Ltrs geysers complete all as specified and directed.
Supply and fixing in replacement of outer body made fabricated of 1.6mm MS Sheet for geysers of 25 Ltrs capacity duly painted with spray point with clamps 02 Nos of with necessary nut bolts complete all as specified and as directed.
All as per Srl Item no 63 above but for geysers of 50 Ltrs Capacity.
Supply only 1.5 KW capacity Heating Element, Push/ Screw type with ‘O’ ring/ triangle cup type including making electrical connection complete all as directed by the Engineer-in-Charge.
All as per Srl item No 65 but of capacity 2.0 KW
Supply only 1.5 KW capacity Heating Element, Push/ Screw type suitable for BAJAJ/ Racold model Geyser including making electrical connection complete all as directed by the Engineer-in-Charge.
Material and Labour for Thermostat switches for geysers 25/ 50 Ltr capacities including making connection complete all as directed by the Engineer-in-Charge.
Supply and fix of geyser assembly suitable for 25 ltr capacity ISI marked including dismantiling of old unserviceable geyser assembly complete all as specified and directed.
All as per item No 69 but of capacity 50 Ltr.
Supply only glass wool for insulation of geyser 25/50 Ltrs capacity and any make all as directed by the Engineer-in-Charge at site.
Supply & Fixing in replacement non-return-valve 15 mm bore horizontal/vertical suitable for any make and any type geysers complete all as specified and directed at site.
Supply and fixing in replacement indicator lamp round /rectangular and making electric connections (Red/Green) 220 Volts AC as per site requirement suitable for geysers complete all as directed
Supply and fixing in replacement safety valve spring locked type in repair with inlet coupling all as specified and directed
Supply & fixing in replacement chromium plated copper pipe connection (Heavy Duty) with two numbers brass adopters of suitable length for fixing one end at geyser & other end at water outlet point for hot water complete all as approved and directed
Supply and fixing in replacement Bib taps cast copper alloy with capstan heads chromium plated screwed down high pressure with or without letered “Hot” or “Cold” with long screwed shank and fly nuts screwed for 15 mm bore GI pipe confirming to ISI and all as specified and directed
Supply & fixing in replacement GI pipe 15 mm dia medium grade laid alongwith wall/ (concealed/ ground/ trench) with all fittings fixed with clamps including breaking of existing walls/tiles etc, if required and making good to disturbed surfaces of wall same as existing position by fixing new tiles etc complete all as specified & directed by Engineer-in-Charge. (Note : Any minor work left over in this item is to be carried out and complete the work. The rates are deemed to be included in this item)
Supply and fix in replacement metal plug socket single pole and neutral enclosure with two pin earth plug with 1 No MCB SP 20 amps 'c' series complete all as specified and directed.
Supply and fixing PVC connection heavy duty with brass /PTMT nuts of reqd |ength not exceeding 300 mm with rubber & PVC washer suitable for 15 mm bore GI pipe complete for cold water complete all as specified and directed.
S & F of fusible plug for suitable capacity of geysers complete all as specified and directed.
S & F brass nipple chromium plated 1/2" of suitable size fitted in 25/50 Ltr capacityof geysers.complete all as specified and directed.
S& F PVC insulated un-sheathed multicore stranded copper wire of size 2.5 Sqmm 3 core complete all as specified and directed.
S&F in replacement plug top 15 Amps 240 Volts complete all as specified and directed.
Dismantling of exhaust fans AC single phase 230 volts of 450 mm Sweep AC single phase fan store ) any make / model except old vintage, dismantled its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish as aproved incl. cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required all as specified and directed by Engineer -In - charge for exhaust fans following sizes :
All as per Srl item No 84 above but 300mm sweep
All as per Srl item No 84 above but 300mm sweep
S & F in repair Exhaust fan plastic body 200 MM sweep 230 v 50 Hz complete internally prewired all as sepcified and directed.
S & F in repair Exhaust fan plastic body 250 MM sweep 230 v 50 Hz complete internally prewired all as sepcified and directed.
Taking down carefully unservicable ceiling fan/ wall mounted fan of any size from existing location and fixing back to its original location after servicing clenning,oiling & greseing and spray painting complete including writing of MES No. all as directed by Eng-in-charge. ( Note:- spares if any required are re-winding etc. shall be measured and paid separately)
Material and labour for re-winding of ceiling fan 1200 sweep and carrying out rewinding with proper grade/guage super enamelled copper winding wire ( approximate weight of winding wire 275 -325 gms /fan ) so as to achieve original specifications i.e current rating and RPM including all insulating materials,bushes etc re-assembling including testing for continious 2 hrs complete all as specified and directed Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
Material and labour for re-winding of wall mounted fan 400 sweep and carrying out rewinding with proper grade/guage super enamelled copper winding wire ( approximate weight of winding wire 250 -330 gms /fan ) so as to achieve original specifications i.e current rating and RPM including all insulating materials,bushes etc re-assembling including testing for continious 2 hrs complete all as specified and directed Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
Material and labour for re-winding of padestal fan 400 sweep and carrying out rewinding with proper grade/guage super enamelled copper winding wire ( approximate weight of winding wire 350-400 gms /fan ) so as to achieve original specifications i.e current rating and RPM including all insulating materials,bushes etc re-assembling including testing for continious 2 hrs complete all as specified and directed Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
S & F in repair wall mounted fan 400 MM sweep, 3 blade complete internally prewired all as sepcified and directed.
M&L for fan hook fabricated with MS flat 25x6mm 300 mm long 02 nos bend to shape drilled with holes and MS nuts ,bolts and washers of required side with one coat of primer and two coats of paints all as directed.
Supply only Fan capacitor 2.5 MFD. Make - Philips/Bajaj/CG
S & F fan regulator, electronic stepped type (ISI mark), 240 volts complete all as specified and directed.
S & F fan regulator, electronic dimmer (ISI mark), 240 volts complete all as specified and directed.
M & L for sub main wiring with two single core 4 Sqmm PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including PVC casing capping of suitable size with all fittings and fixing accessories on roof, walls, ceiling etc. including 1x 4.0 Sqmm PVC insulated unsheathed single core solid copper conductor earth wire including taking down existing unserviceable one and removing from site complete all as specified and directed (Note: Two run of single core cable and one run earth wire will be measured as one length)
M/S P K ROY AND SONS
M/S SANJIB DEB
M/S TAPAN KUMAR RAY
M/S M P Sharma
m/s builders and suppliers
NAGALAND AGENCIES CO
SURANA CORPORATION
M/S PIJUSH BHATTACHARJEE
M/S LUIT CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .