Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 LAccepted-AOC AT GANDHI CHOWK BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L1 | Accepted-AOC On being L1 | |
| 2 | L2₹1.3 L+₹23,978.94 (21.9%)Rejected-Finance AT RAJRAPPA PROJECT PS RAJRAPPA DIST RAMGARGH JHARKHAND 825101 | RAMGARH | RAMGARH | JHARKHAND | 825101 | L2 | Rejected-Finance On being L2 | |
| 3 | L3₹1.5 L+₹42,066.83 (38.5%)Rejected-Finance AT BUDHIJAM COLONY ORIENT COLLIERY BRAJRAJNAGAR JHARSUGUDA ODISHA 768216 | JHARSUGUDA | ODISHA | 768216 | L3 | Rejected-Finance On being L3 | |
| 4 | L4₹1.8 L+₹75,674.78 (69.3%)Rejected-Finance KAMALA BIHAR BAGHUABOL PO HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | L4 | Rejected-Finance On being L4 |
Tender Value
₹2.5 L
EMD Value
₹3,100
Closing Date
7 Oct 2024, 5:00 pmClosed
Pramod Swarnkar, Sr Manager (EnM)
Office of the Project Engineer (EnM), ILBL OCP, Lakhanpur Area
Repair of wiring arrangements of siding In-charge room, sampling room and control room of Y-curve siding, ILBL OCP, Lakhanpur Area, MCL
2024_MCL_318106_1
MCL/LKPA/ILBL/ePC-EM/24-25/16
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
EnM Department, ILBL OCP, Lakhanpur Area, MCL
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,100
16 Nov 2024
25 Sept 2024
9 Oct 2024
25 Sept 2024
7 Oct 2024
25 Sept 2024
25 Sept 2024 - 30 Sept 2024
Amount
Wiring with 1.5 sqmm, FRLS PVC insulated single core (multistrand) copper conductor (ISI marked) for light point/fan point/exthust fan point/call bell point cable in surface/recessed medium class PVC conduit,with 5Amp, 250 V one way modular switch (ISI marked), modular plate, suitable unit G.I. box and earthing the point with 1.5 sq. mm, FRLS PVC insulated copper conductor single core (multistrand) cable etc as required (Group A) (Brand like Havells, Legrand, V-Guard, Finolex, L&T, Anchor, Polycab, Schneider, V-Guard, Finolex & equivalent)
Wiring with 2.5 sqmm FRLS PVC insulated double core multistrand copper conductor for circuit / sub main wiring [ISI Marked], along with earth wire of 2.5 sqmm, single core, multistrand cable in surface/recessed medium class PVC conduit as required (2 x 2.5 sq mm+1 X 2.5 sqmm) (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider, V-Guard, Finolex & equivalent)
Wiring with 4 sqmm, double core multistrand, FRLS PVC insulated copper conductor for circuit / sub main wiring [ISI Marked] along with earth wire with 4 sqmm, single core cable in surface/recessed medium class PVC conduit as required (2 x 4 sq mm+1 X 4 sqmm) (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider, V-Guard, Finolex & equivalent)
S/F 5 amps. to 32 amps rating, 240/415 V, 10KA, 50/60 HZ "C" curve, ISI marked MCB/SPMCB suitable for inductive load of following poles in the existing MCB DB Complete with connections, testing & commissioning etc. as required.(Single Pole) (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider & equivalent)
S/F 5 amps. to 32 amps rating, 240/415 V, 10KA "C" curve, ISI Marked MCB/SPNMCB suitable for inductive load of following poles in the existing MCB DB Complete with connections, testing & commissioning etc as required.(Single Pole & Neutral) (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider, V-Guard, Seimens & equivalent)
S&F 3 pin,5 amps ceiling rose [ISI Marked] on the existing junction box / wooden block including connectin etc as required (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider, V-Guard, Seimens & equivalent)
Supplying & fixing following 5/6 Amp, 250 V modular switch/socket (ISI marked) on the existing modular plate and switch box including connections but excluding modular plate etc as reqd. (5/6 amp. switch) (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider & equivalent)
Supplying & fixing following modular switch/ socket [ISI Marked] on the existing modular plate and switch box including connections but excluding modular plate etc as reqd. (3 pin, 5/6 amp.socket outlet), 250 V (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider & equivalent)
S/F suitable size G.I. Box with modular plate and cover in front on surface or recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc, as required. (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider, Seimens & equivalent)
Supplying & fixing two module stepped type, Nos. of step = 5, electronic fan regulator [ISI Marked] on the existing or other modular plate switch box including connections but excluding modular plate etc. as required. (Amp/V rating) (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider & equivalent)
S&F following size/modules, GI box along with modular base & cover plate for modular switches in recess et as required. (6 Module) , (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider & equivalent)
S&F following size/modules, GI box along with modular base & cover plate for modular switches in recess et as required. (8 Module), (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider & equivalent)
Supply & fixing of 18 watt LED complete tube light fittings wall mounted 220V , Voltage: 220-240V, Lumens: 1600-1800 , PF=0.9 (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider, Crompton, Philips & equivalent)
Installation, testing & commissioning of Pre-wired,Fluorescent fitting Compact fluroscent of all type, complete with all accessories and tube/lamp etc directly on ceiling/wall including connections with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required. (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider & equivalent)
P/F 100 amp TP & N Disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling Holes in cubicle panel, making connection,etc as required. Voltgage- cable entry sizes short circuit Rating Mounting (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider & equivalent)
P/F 200 amp TP & N Disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling Holes in cubicle panel, making connection,etc as required. (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider & equivalent)
S&F following Way, single pole & Neutral, Sheet Steel, MCB distribution board, 240 V, on Surface/recess, complete with Tinned copper bus bar, Neutral bus bar, earth bar, Din bar, Interconnections, powder painted including earthing etc as required. (but without MCB/RCCB/Isolator). (06Way Double Door) (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider, V-Guard, Seimens & equivalent) .
Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required.
Supply, installation and commissioning of maintenance free earthing system earth resistance upto 01 ohm with test certificate: Specification: Earthing electrode - 50/3 MTPCB, 3M X 58mm, THK:50, 250 Micron copper coating on GI pipe, Terminal size-40/6, inner strip- 25 x 3, filling material BFC silica base bentonite powder 50kg, Earth pit digging by spiral machine, Pit cover- Poly Plastic (BIG) primary earthing electrode (outer pipe) of 99.9% pure copper coating (250 micron) on GI pipe (diameter 58mm) X 3 mtrs. The hollow space of the electrode is duly filled with a highly conductive and non-corrosive compound (graphite power) which safeguards the secondary electrode getting corrode over a long period of time under the soil. Also the compound ensures the easy distribution of leakage/fault current lands on the electrode, Both the end s of the electrode are permanenetly sealed and the top portion of the earth electrode is compressed to form and extended lead with 2 holes on the terminal for connecting to the load/equipment.
Providing and fixing following rating and breaking capacity and pole MCCB (ISI marked) with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (100 A, 16 KA,TPMCCB) (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider, V-Guard, Seimens & equivalent)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit [ISI Marked], as required.(4 X 16 sq. mm + 2 X 6 sq. mm earth wire ) (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider, Finolex, V-Guard, Seimens & equivalent)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit [ISI Marked], as required. (3 x 6 sq. mm ) (Brand like Havells, Legrand, L&T, Anchor, Polycab, Schneider, Finolex, V-Guard, Seimens & equivalent)
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/s Vaishnavi Engineering and Construction
M/s BIKASH ENTERPRISES
M/s. Sahida Electrical Works
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .